Regency E33 Sunrise Gas Insert
Model E33S-NG1 E33S-LP1
Fuel Type Natural Gas Propane
Manifold Pressure - High 3.8” W.C. (0.95 kPa) 11” W.C. (2.74 kPa)
Manifold Pressure - Low 1.1” W.C. (0.27 kPa) 2.9” W.C. (0.72 kPa)
Orifice Size -
Minimum Input
Altitude 0-4500 ft. (0-1372m)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
Vent Sizing
Altitude 0-4500 ft. #42 DMS #54 DMS
13,500 BTU/h
(3.95 kW)
26,000 BTU/h
(7.61 kW)
3” Co-linear 3” Co-linear
Approved Venting Systems
Flex Vent Systems: FPI AstroCap™ Flex Vent
12,000 BTU/h
(3.51 kW)
23,000 BTU/h
(6.74 kW)
E33S Sunrise Gas Insert
Minimum Fireplace Dimensions
The minimum fireplace dimensions for the FPI gas fireplace insert are shown in the following diagrams:
Dimension Description E33S
A Faceplate Width 46-3/4” (1187mm)
B Faceplate Height 30-5/8” (778mm)
C Unit Width 32-1/8” (816mm)
D Unit Height 23-3/4” (603mm)
E Unit Depth 16-1/2” (419mm)
F Faceplate to Vent Centerline 11-3/8” (290mm)
G Faceplate Depth 1-1/8” (28mm)
H Height to Vent Collar 22-7/8” (581mm)
I Faceplate Depth 2-7/8” (72mm)
This manual is intended to be a Sales Reference Guide only. Do NOT use for actual framing and installation of any unit. Some specifications may change without notice. You must use the actual manual for exact installation specifications.
Dimension Description E33S
J Height 24-3/16” (614mm)
K Width 32-1/4” (819mm)
L Depth 16-3/4” (426mm)
M Max. Lintel Bar Depth 8” (203mm)
N Rear Width 25” (635mm)
WARNING
Failure to maintain required clearances is a major cause of chimney related fires. Installation of this fireplace must comply with these clearances
Please note: Due to ongoing product development, product appearance and specifications
are subject to change without notice.
E33S Sunrise Gas Insert
Regency E33 Sunrise Gas Insert
Clearances
Unless otherwise stated the clearances listed below are Minimum distances to combustible materials. Please Note: A major cause
of chimney related fires is due to a failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions.
Clearances to Combustibles
Dimension Description E33S
A* From Unit to Side Walls 8” (203mm)
B From Unit to Ceiling 47” (1194mm)
C Minimum Mantel Height 15” (381mm)
D Maximum Mantel Depth 3-1/2” (89mm)
E Alcove Width 76” (1930mm)
F Alcove Depth 36” (914mm)
* Alcove side wall must have a minimum of 8” (203mm) clearance on one side.
Combustible Mantels
Because of the extreme heat this fireplace emits, the mantel clearances are critical. Mantel may be installed anywhere in the
shaded area or higher.
Note: A non-combustible mantel may be installed at a lower
height.
Note: Ensure the paint that is used on the mantel and the facing
is “heat resistant” or the paint may discolour.