Failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
919-788c FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H408.14.18
Page 2
2
|
CONGRATULATIONS!
You are the owner of a state-of-the-art Gas Insert by:
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.
The Regency® Gas Fireplace Series has been designed to provide you with all the warmth and charm
of a fireplace, at the flick of a switch. The models E18E-NG and E18E-LP of this series have been
approved by Intertek/Warnock Hersey for safety. As it also bears our own mark, it promises to provide
you with economy, comfort and security for many trouble free years to follow. Please take a moment
now to acquaint yourself with these instructions and the many features of your Regency® Fireplace.
2 | Regency
®
E18E Gas Fireplace Insert
Page 3
UNIT DIMENSIONS
13 3/4"
349mm
23 15/16"
608mm
14 9/16"
370mm
34 7/16"
875mm
3 15/16"
100mm
11"
280mm
16 5/8"
423mm
23 9/16"
598mm
29 3/8"
747mm
7 1/4"
184mm
1 15/16"
50mm
installation
|
3
Diagram 1.1
Overall Faceplate Dimensions:
616-920 - Low Profile Faceplate (Firesong FS220N) 35 5/8" wide x 29 5/8" High
616-921 - Low Profile Faceplate (Montigo 28F/28F-2/28F-3) 34 1/4" Wide x 28 1/2" High
616-924 - Low Profile Faceplate (Montigo EP28-4/EP28-5/EconoPlus 28C) 34 7/16" wide X 29 3/8" High
616-926 - Low Profile Faceplate (Montigo 36SR) 34 3/8" Wide X 27 1/4" High
616-928 - Low Profile Faceplate (Firesong FS120N) 32 5/8" Wide X 28 1/4" High
617-948 - Low Profile Faceplate Zero Clearance Applications 34 7/8" Wide X 29 3/8" High
NOTE: also includes a perimeter finishing trim 37 3/8" Wide X 32 1/4" High
616-924 -- Low Prole Faceplate shown
Regency
®
E18E Gas Fireplace Insert | 3
Page 4
4
|
table of contents
Unit dimensions .............................................................3
WARNING: If you do not follow these instructions exactly, a fire orexplosion may result causing property damage, personal injury or loss oflife. Improper installation,adjustment, alteration,service or maintenancecan cause injury or property damage. Refer to the owner’s informationmanual provided with this appliance. For assistance or additionalinformation consult a qualified installer, service agency or gas supplier.AVERTISSEMENT. Quiconque ne respecte pas scrupuleusement lesinstructions de la présente notice risque de déclencher un incendie ou une explosion pouvant entraîner des dégâts matériels ou des blessures pouvant être mortelles. Tout défaut d'installation, de réglage, de modication, de service ou d'entretien peut entraîner des blessures ou des dommages matériels. Reportez-vous au manuel d'utilisation fourni avec cet équipement.Pour obtenir de l'aide ou des informations complémentaires, consulter un
installateur ou un service d'entretien qualié, ou le fournisseur de gaz.
1) Turn on ON/OFF switch
2) After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner.
3) The unit will turn on.
Note: The rst attempt to ignition will last approximately 60 seconds. If there is no ame ignition (rectication) the board will stop sparking for approximately 35 sec-
onds. After this wait time, the board will start a second try for ignition by sparking for approximately 60 seconds. If there is still no positive ignition after the second attempt the board will go into lock out.
The system will need to be reset as follows (after going into lock out mode):a) Wait 5 minutes - turn the system o using ON/OFF switch.
b) After approximately 2 seconds turn on ON/OFF switch or press ON/
OFF button if using optional remote.
c) Unit will repeat step 2.
1) Appuyer sur la touche ON / OFF de l'interrupteur.
2) Attendre 4 secondes. Le système d’allumage produira des étincelles pendant 60
secondes an d’amorcer le brûleur principal.
3) L'appareil s’allume.
Remarque : Au premier allumage, le système tente d’allumer les ammes pendant
60 secondes. Si l’essai est infructueux, le système fait une pause de 35 secondes.
C’est ce qu'on appelle l'étape de rectication. Ce délai écoulé, le système tente à nouveau d'allumer les ammes en produisant des étincelles pendant 60 secondes. Si les ammes ne s’allument toujours pas, le système se met en mode verrouillage.
Il faut alors le réinitialiser en suivant les étapes ci-dessous (pour le déverrouiller) :
a) Attendre 5 minutes et éteindre l’appareil en utilisant l’interrupteur ON/
OFF;
b) Attendre environ 2 secondes et rallumer le système à l’aide de
l’interrupteur ou de la télécommande en option.
c) L'appareil répétera l'étape 2.
1) Turn o ON/OFF switch
FOR YOUR SAFETY READ BEFORE LIGHTING
LIGHTING INSTRUCTIONS
printed a copy of the contents here for your review. The safety label is located on the
front inside base of the unit visible when the bottom louver is open.
Note: Regency® units are constantly being improved. Check the label on the
unit and if there is a difference, the label on the unit is the correct one.
Please note that with the addition of thermostat control and outside
combustion air supply, this unit is approved for bedroom installations.
safety decal
|
5
For the State of Massachusetts, installation and repair must be done by a plumber
or gasfitter licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, flexible connectors shall not exceed 36 inches
in length.
For the State of Massachusetts, the appliances individual manual shut-off must
be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm
in accordance with NFPA 720 and a CO alarm with battery back up in the same
room where the gas appliance is installed.
Regency
®
E18E Gas Fireplace Insert | 5
c
Page 6
6
|
requirements
MA Code - CO Detector
(for the State of Massachusetts only)
5.08: Modifications to NFPA-54, Chapter 10
(2) Revise 10.8.3 by adding the following additional requirements:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for
residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than
seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall
be satisfied:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled
equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is
installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery
operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure
served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of
qualified licensed professionals for the installation of hard wired carbon monoxide detectors
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon
monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of
thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon
monoxide detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions
shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.
3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight
(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The
sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL
OBSTRUCTIONS".
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation
unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR
5.08(2)(a)1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by
the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or
structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product
Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the
instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a
Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies
"special venting systems", the following requirements shall be satisfied by the manufacturer:
1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and
2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and
detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions,
all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of
the installation.
6 | Regency
®
E18E Gas Fireplace Insert
Page 7
installation
|
7
BEFORE YOU START
Safe installation and operation of this appliance
requires common sense, however, we are required
by the Canadian Safety Standards and ANSI
Standards to make you aware of the following:
INSTALLATION AND REPAIR SHOULD
BE DONE BY AN AUTHORIZED
SERVICE PERSON. THE APPLIANCE
SHOULD BE INSPECTED BEFORE
USE AND AT LEAST ANNUALLY BY A
PROFESSIONAL SERVICE PERSON.
MORE FREQUENT CLEANING MAY
BE REQUIRED DUE TO EXCESSIVE
LINT FROM CARPETING, BEDDING
MATERIAL, ETC. IT IS IMPERATIVE THAT
CONTROL COMPARTMENTS, BURNERS
AND CIRCULATING AIR PASSAGEWAYS
OF THE APPLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES, THE
APPLIANCE SHOULD BE LOCATED
OUT OF TRAFFIC AND AWAY FROM
FURNITURE AND DRAPERIES.
WARNING: FAILURE TO INSTALL THIS
APPLIANCE CORRECTLY WILL VOID
YOUR WARRANTY AND MAY CAUSE A
SERIOUS HOUSE FIRE.
CHILDREN AND ADULTS SHOULD BE
ALERTED TO THE HAZARDS OF HIGH
SURFACE TEMPERATURES, ESPECIALLY THE FIREPLACE GLASS, AND
SHOULD STAY AWAY TO AVOID BURNS
OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE
IN THE SAME AREA AS THE APPLIANCE. TODDLERS, YOUNG CHILDREN
AND OTHERS MAY BE SUSCEPTIBLE
TO ACCIDENTAL CONTACT BURNS. A
PHYSICAL BARRIERS IS RECOMMENDED IF THERE ARE AT RISK INDIVIDUAL
IN THE HOUSE. TO RESTRICT ACCESS
TO A FIREPLACE OR STOVE, INSTALL
AN ADJUSTABLE SAFETY GATE TO
KEEP TODDLERS, YOUNG CHILDREN
AND OTHER AT RISK INDIVIDUALS OUT
OF THE ROOM AND AWAY FROM HOT
SURFACES.
CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NOT BE PLACED
ON OR NEAR THE APPLIANCE.
A BARRIER DESIGNED TO REDUCE
THE RISK OF BURNS FROM THE HOT
VIEWING GLASS IS PROVIDED WITH
THIS APPLIANCE AND SHALL BE
INSTALLED FOR THE PROTECTION
OF CHILDREN AND OTHER AT-RISK
INDIVIDUALS
IF THE BARRIER BECOMES DAMAGED,
THE BARRIER SHALL BE REPLACED
WITH THE MANUFACTURER'S BARRIER
FOR THIS APPLIANCE.
ANY SAFETY SCREEN, GUARD, OR
BARRIER REMOVED FOR SERVICING
AN APPLIANCE MUST BE REPLACED
PRIOR TO OPERATING THE APPLIANCE.
IMPORTANT MESSAGE
SAVE THESE INSTRUCTIONS
The Regency® Gas Fireplace must be installed in
accordance with these instructions. Carefully read
all the instructions in this manual first. Consult the
"authority having jurisdiction" to determine the need
for a permit prior to starting the installation. It is the
responsibility of the installer to ensure this fireplace
is installed in compliance with the manufacturer's
instructions and all applicable codes.
GENERAL SAFETY
INFORMATION
The condition of the appliance, that the E18E is
to be installed into, shall be in accordance with
reasonable concepts of safety, substantiality and
durability. Component parts shall be well fitted and
not show signs of becoming warped, bent, broken
or otherwise damaged during the installation. Every
part of the appliance shall be secured against
displacement and constructed to maintain a fixed
relationship between essential parts under normal
and reasonable conditions of handling and usage.
1. The appliance installation must conform with
local codes or, in the absence of local codes,
with the current Canadian or National Gas
Codes, CAN1-B149 or ANSI Z223.1 Installation
Codes.
2. The appliance when installed, must be electrically grounded in accordance with local codes,
or in the absence of local codes with the current
National Electrical Code, ANSI/NFPA 70 or CSA
C22.1 Canadian Electrical Code.
3. See general construction and assembly instructions. The appliance and vent should be
enclosed.
4. This appliance must be connected to the specified vent and termination cap to the outside of
the building envelope. Never vent to another
room or inside a building. Make sure that the
vent is installed as per Venting instructions.
5. This appliance may only be installed in an approved zero clearance gas appliances listed in
this manual, or as a zero clearance appliance.
6. This appliance is Listed for bedroom installations
when used with a Listed Millivolt Thermostat.
Outside combustion air supply is also required.
Some areas may have further requirements,
check local codes before installation.
7. This appliance is Listed for Alcove installations,
maintain minimum Alcove clearances as follows,
minimum ceiling height of 37-7/8" from the top
of the glass door, minimum width of 49" and a
maximum depth of 29".
8. Inspect the venting system annually for blockage
and any signs of deterioration.
9. Any safety glass removed for servicing must be
replaced prior to operating the appliance.
10. To prevent injury, do not allow anyone who is
unfamiliar with the operation to use the fireplace
insert.
11. Wear gloves and safety glasses for protection
while doing required maintenance.
12. Ensure adequate combustion and ventilation
air.
13. Under no circumstances should this appliance
be modified. Parts that have to be removed for
servicing should be replaced prior to operating
this appliance.
14. Installation and any repairs to this appliance
should be done by a qualified service person. A
professional service person should be called to
inspect this appliance annually. Make it a practice to have all of your gas appliances checked
annually.
15. Unit is not designed to be installed with a
powervent system.
16. Do not slam shut or strike the glass door.
Regency
®
E18E Gas Fireplace Insert | 7
Page 8
8
|
installation
17. Under no circumstances should any solid fuels
(wood, paper, cardboard, coal, etc.) be used in
this appliance.
18. The appliance area must be kept clear and
free of combustible materials, (gases and other
flammable vapours and liquids).
19. Do not use this appliance if any part has been
under water. Immediately call a qualified service technician to inspect the appliance and to
replace any part of the electrical control system
and any gas control which has been under water.
WARNING: Failure to position the
20.
parts in accordance with the diagrams
in this manual or failure to use only
parts specifically approved with this
appliance may result in property
damage or personal injury.
21.WARNING: Operation of this appliance
when not connected to a properly
installed and maintained venting
system or tampering with the blocked
vent shut-off system can result in
carbon monoxide (CO) poisoning and
possible death.
INSTALLATION
CHECKLIST
1. Locate your appliance. Refer to the "Clearances
to Combustibles" and "Minimum Fireplace
Clearances" sections.
2. Make gas and electrical connections. Refer to
the "Gas Connection" section.
Test the pilot. Refer to the "Pilot Adjustment"
section.
3. Install Flue Connector. Refer to the section on
installation specifications.
4. Install vent. Refer to the "Venting" section.
5. Test Gas pressure. Refer to the "Gas Pipe
Pressure Testing" section.
Check aeration. Refer to the "Gas Insert Aera-
tion System" section.
6. Test for flue spillage. Refer to the "Drafthood
Check" section.
7. Install standard and optional features. Refer
to the following sections where applicable:
a. Brick or Enamel Panels
b. Faceplate & Trim
c. Circulation Fan
d. Remote Control
e. Wall Switch
f. Wall Thermostat
8. Final check. Refer to the "Final Check" section.
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly and operation fully explained to customer.
This includes:
1. Clocking the appliance to ensure the correct
firing rate (rate noted on label) after burning
appliance for 15 minutes.
Specifications
For Altitude: Natural Gas 0-4500 ft.
Propane: 0-4500 ft.
Burner Orifice Sizes:
Natural Gas Propane
Burner #44 #55
Max. Input Rating
- Natural Gas 21,600 Btu/h
- Propane 20,500 Btu/h
Min. Input Rating
- Natural Gas +/-5% 15,000 Btu/h
-Propane +/-5% 17,000 Btu/h
Supply Pressure
Natural Gas min. 5.0" w.c.
Propane min. 12.0" w.c.
Manifold Pressure (High)
Natural Gas 3.5" +/- 0.2" w.c.
Propane 10" +/- 0.2" w.c.
Circulation Fan: 120 VAC, 60 Hz
Variable Speed: 127 CFM, thermally
actived
GAS CONNECTION
Only persons licensed to work with gas piping
may make the necessary gas connections to this
appliance.
The gas connection is a 1/2" NPT accessible on the
left side of the unit. The gas line connection may
be made of rigid pipe, copper pipe or an approved
flex connector. (If you are using rigid pipe, ensure
that the valve can be removed for servicing.) Since
some municipalities have additional local codes it
is always best to consult with your local authorities
and the CAN/CGA B149 installation code.
For USA installations follow local codes and/or the
current National Fuel Gas Code, ANSI Z223.1.
8 | Regency
®
E18E Gas Fireplace Insert
2. If required, adjusting the primary air to ensure
that the flame does not carbon. First allow the
unit to burn for 15-20 min. to stabilize.
3. Ensure that the appliance is venting correctly.
CAUTION: Any alteration to the product that
causes sooting or carboning that results in damage is not the responsibility of the manufacturer.
When using copper or flex connectors use only
approved fittings. Always provide a union so that
gas lines can be easily disconnected for burner or
fan servicing. Flare nuts for copper lines and flex
connectors are usually considered to meet this
requirement.
Important: Always check for gas leaks
with a soap and water solution or gas
leak detector. Do not use open flame for
leak testing.
Page 9
installation
6
|
9
PILOT ADJUSTMENT
Periodically check the pilot flames. Correct
flame pattern has two strong blue flames:
1 flowing around the flame sensor and 1
flowing across the burner (it does not have
to be touching the burner).
Burner
Flame Sensor
Pilot
Note: Ifyouhaveanincorrectamepattern,
contact your Regency® dealer for
further instructions.
Incorrect flame pattern will have small,
probably yellow flames, not coming into
proper contact with the rear burner or flame
sensor.
Ignitor
GAS PIPE PRESSURE
TESTING
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut-off valve during any pressure
testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig.
(3.45 kPa). Disconnect piping from valve at
pressures over 1/2 psig.
The manifold pressure is controlled by a regulator
built into the gas control, and should be checked
at the pressure test point.
Note: To properly check gas pressure, both
inlet and manifold pressures should
be checked using the valve pressure
ports on the valve.
1. Make sure the switch is in the "OFF" position.
2. Loosen the "IN" and/or "OUT" pressure
tap(s), turning counterclockwise with a
1/8" wide flat screwdriver.
3. Attach manometer to "IN" and/or "OUT"
pressure tap(s) using a 5/16" ID hose.
4. Light the pilot by turning the switch to "ON"
position.
HIGH ELEVATION
This unit is approved in Canada for altitude to
4500 ft. (CAN/CGA-2.17-M91). For Natural Gas
installations above 4500 ft. follow current CAN/
CGA-B149.1.
886 S.I.T. VALVE DESCRIPTION
1) Manual high/low adjustment
2) Pilot adjustment
3) Outlet Pressure Tap
4) Inlet Pressure Tap
5) Pilot Outlet
6) Main Gas Outlet
7) Main Gas Inlet
5. The pressure check should be carried out
with the unit burning and the setting should
be within the limits specified on the safety
label.
6. When finished reading manometer, turn
off the gas valve, disconnect the hose and
tighten the screw (clockwise) with a 1/8" flat
screwdriver. Note: Screw should be snug,
but do not over tighten.
4
3
7
Regency
1
2
5
®
E18E Gas Fireplace Insert | 9
Page 10
10
|
installation
INSTALLATION CHECKLIST
1. Verify the model of the existing appliance you
are installing into is one of the following approved units:
2. Verify all clearances are at least the specified
clearances.
3. Inspect existing venting and appliance for signs
of wear and durability.
4. Determine the route for the electrical for the
circulation fan. The circulation fan is not optional.
5. Determine the route for the gas supply. The valve
has a 1/2" Male Flare on the left side of the E18E.
Some modification may need to be made to a
hard lined gas supply to connect to the E18E.
6. Clean out the existing appliance of all dust and
debris.
7. Make the appropriate modifications to the existing
appliance specified in the "Existing Appliance
Modification" section of the manual. Make sure
when done there are no sharp edges exposed
to a person during operation of the unit.
8. Unpack the E18E from the box and disassemble.
9. Install the E18E into the existing unit as per
instructions.
10. Connect Gas Supply.
11. Connect Circulation Fan Power Cord.
12. Test Fire the E18E and check gas pressures
and confirm Circulation Fan begins operation
with 10 minutes of firing the unit.
13. Check draft hood for spillage as per instructions.
14. Install Trim Kit as per instructions.
MATERIALS REQUIRED
Electrical power supply is required for the circulation
fan A 120 Volt AC power cord is hooked up to the
fan. Plug the 3 wire cord into a suitable receptacle. Do not cut the ground terminal off under any
circumstances. When connected with 120 volts,
the appliance must be electrically grounded in accordance with local codes, or in the absence of local
codes, with the current Canadian Electrical Code
CSA C22.1 (in Canada) or with the current National
Electrical Code ANSI/NFPA 70-1987 (in U.S.A.).
NOTE: This unit is equipped with a heat sensor
thermodisc which will prevent the blower
from operating until the unit reaches the
correct temperature.
VENTING
THE APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE
SERVING A SEPARATE SOLID FUEL
BURNING APPLIANCE.
This appliance is designed to attach to a 4" diameter
type B-Vent or double thickness approved aluminium
flex liner.
VENTING CONFIGURATIONS
The E18E is approved to be attached to any of
the approved appliances listed in the Installation
Checklist. The existing unit must be connected to
B-Vent Pipe having at least 8 feet of vertical venting
and can have a maximum of 6 feet horizontal venting with two 90 degree elbows. The venting must
terminate vertically with an approved B-Vent Cap.
All horizontal runs must maintain a 1/4" of rise for
every foot of horizontal run.
The flue collar of the appliance will fit inside a
standard vent and may be fastened directly to the
vent using a minimum of 3 sheet metal screws or
a B-Vent, single wall vent connector.
B-Vent chimneys require a 1" clearance to combustibles.
The Regency
draft hood, so no additional external draft hood is
required. Check periodically that the vent is unrestricted and an adequate draft is present when the
unit is in operation.
Before installing the vent system ensure that the
damper plate is locked into the open position and
secure to prevent the damper plate from falling
down and crushing the liner.
The appliance is equipped with a vent safety shutoff
system and a safety control system designed to
protect against improper venting of combustion
products. The appliance will not function without
being connected to a proper system.
®
Insert incorporates its own internal
WARNING: Operation of this heater when
not connected to a properly installed and
maintained venting system or tampering
withtheventshut-osystemcan result
in carbon monoxide (CO) poisoning and
possible death.
This appliance must not be connected to a chimney
flue serving a separate solid fuel burning appliance.
For best venting performance, we recommend the
following venting rules:
1. Use only certified Type B gas vent or approved
flex liner.
2. Follow the vent manufacturer's instructions and
clearance requirements.
3. Observe any local code restrictions, if any,
regarding the installation of gas inserts.
4. Use as few elbows as possible.
5. Keep horizontal lengths as short as possible
and maintain at least an upward slope of 1/4 in.
(6.4mm) for every 12 in. (305mm) of horizontal
run.
6. Terminate the vent with a suitable certified
vent cap.
10 | Regency
®
E18E Gas Fireplace Insert
Page 11
installation
MINIMUM FIREPLACE CLEARANCES TO COMBUSTIBLES
Diagram shows the minimum clearances to any combustible material. Installer must check that all installs maintain at least these clearances..
|
11
The minimum clearance from the side of the appliance to a combustible
side wall is 9" (229mm). The minimum clearance from the bottom edge
of the front trim above the window to a combustible mantel is 17- 7/8 "
(454 mm). The minimum height from bottom edge of the front trim above
the window to the ceiling is 37-7/8"(962 mm).
37 1/2"
953mm
21"
3 3/4"
95mm
11 1/4"
286mm
7 1/16"
180mm
533mm
Note: A non-combustible mantel and framing may be installed
at a closer tolerance if the framing is made of metal studs
covered with a non-combustible board.
Electrical connection: 110v required
Fan must be on at all times to operate this unit.
All framing may
DescriptionE18E
A
B
C
12 | Regency
®
E18E Gas Fireplace Insert
Page 13
ZERO CLEARANCE FRAMING
installation
|
13
1. When installing the E18E as a zero clearance, you will use the framing
clearances in the following diagrams. Mantel and inside corner clearances
can be found in Minimum Clearances to Combustibles.
2. Install the Surround to the framing as per manual.
1. Shut down existing unit and allow to cool to room temperature.
2. Turn off gas supply and disconnect electrical.
3. Remove all accessories from existing unit, ie. glass doors, louvers, etc.
4. Remove any tiles, hearth or surround from existing unit (if required).
5. Disconnect gas supply from existing unit.
6. Cut away a perimeter of drywall around the existing unit to expose the framing. See example below.
7. Uninstall existing unit from framing.
Remove unit from framing
8. Disconnect venting from existing unit - remove carefully to avoid damage.
9. Remove existing unit from framed opening.
Cut drywall
Regency
10. Measure framed opening and compare to dimension requirements.
Additional adjustments to framed opening may be required.
®
E18E Gas Fireplace Insert | 13
Page 14
14
|
installation
12. When framing is complete, ensure wiring is installed by an electrician
prior to installing the unit.
13. Assemble ZC surround with 8 (904-897) screws provided in locations
shown below.
Assemble the ZC
surround with 4
screws on each
side.
14. Secure surround to the stud on each side with screws.
15. ZC surround installed into framed opening.
16. Separate E18E inner and outer fireboxes - see installation into existing unit section in the manual for details.
17. Set E18E outside firebox legs as shown below.
Set to this
hole
Use 4 screws on each side to secure
14 | Regency
surround to studs.
®
E18E Gas Fireplace Insert
Right side shown
Outside rebox shown in position - refer to
measurements (Step 18) before securing to surround.
Page 15
installation
DETAIL A
SCALE 1 : 4
Legheight setting
EP28 Installation Specifications
|
15
18. Follow instructions in the manual for installation into a EP28-2 for exact
measurements for installation of the outside firebox to the surround.
EP28 Firebox
8 7/16"
215mm
1 7/16"
5 5/8"
143mm
19. The top panel of the ZC surround may be removed to ease the installation
of the venting - reinstall top panel after venting is installed.
* Extra venting may be required.
A
37mm
21. Install lower trim piece with 2 (904-897) screws to the bottom of the
ZC surround before installing faceplate.
20. Follow instructions in the installation into existing unit section in the
manual to complete the install of inner firebox.
Follow Step 21 before installing faceplate.
Regency
®
E18E Gas Fireplace Insert | 15
Page 16
16
|
installation
REQUIRED STEPS AND PROCEDURES FOR E18E INSTALLATION
1. Locate model on existing ZC box - locate corresponding section in this manual.
2. Make necessary alteration to the ZC firebox as per manual.
3. Separate inner and outer fire box (see procedure in manual).
4. Remove flue adaptor for outer firebox.
5. Make necessary adjustment to flue adapter mounting plate as per manual.
6. Cut flex to required length and secure to top plate using 3 screws and washers.
7. Secure top plate flue adapter to ZC box.
8. Secure flue adapter to flex using 3 screws/washers.
9. Slide outer firebox into place, be sure flue adapter mounting screw doesn't hold unit up on installation.
10. Adjust left and right side legs on outer shell (depends on ZC box it is being intalled in) - See details in manual.
11. Measure and align outer firebox as per manual, secure each corner using self tapping screws.
12. Install inner firebox into outer firebox, ensure draft hood bottom fits on top of draft hood slides, left side, right side and rear.
13. Secure inner firebox - 2 screws on top left and right side - using existing holes.
14. Secure inner firebox on bottom inside - 2 screws on each side. Be sure to re install panel brackets, and line up with existing holes.
15. Reinstall burner.
16. Make gas connection - check for leaks.
17. Install enamel panels.
18. Install Faceplate
19. Install Glass Crystals on burner.
20. Light pilot.
21. Install glass door.
22. Install thermostat.
TOOLS REQUIRED (SUGGESTED)
• Nibbler
• Oscillating tool / metal blades
• Tin snips
• Uni Bit/Step Drill
• Black high temp paint
• Drill/ ¼” bit – Phillips bit
• Measuring tape
• Level
• Sharpie
• Shop vacuum
Optional:
• Plasma cutter
• Fibre drop sheet
• Fire extinguisher
Nibbler
16 | Regency
®
E18E Gas Fireplace Insert
Oscillating tool
Page 17
E18E
SEPARATING THE OUTER FIREBOX SHELL FROM INNER FIREBOX
1. Lay fireplace insert on flat surface (use a drop sheet to protect surface).
2. Remove Glass Door by removing 2 x Phillips screws at the bottom of Glass Door Frame.
3. Remove burner by removing 2 x Phillips screws, take note of how aeration adjustment rod is routed.
Burner
4. Remove 2 Phillips screws from top left and right side (Thermodisc bracket).
Remove 2 x 1/4" Hex head screws from top left side and right side of inner firebox.
Phillips
Screws
Hex Head
Screws
installation
Aeration adjustment Rod
|
17
Remove screws from these locations
5. Remove 4 Phillips screws - 2 per side, located on the bottom base of the firebox. Place
screws and panel brackets aside for reinstallation.
6. Carefully lift out the inner firebox and set aside until required. Use caution with sleeved
wires on the left side, place inner firebox aside.
7. Outer firebox shell is ready for installation.
Refer to particular approved appliance in which the E18E is being installed into for the
following:
Existing unit modifications
Adaptor setting
Required flex length
Leg setting / outer shell position both need to be exact as measurements indicated.
Regency
Outer shell
Before separating Outer Shell and
Unit—Clear wire harness
®
E18E Gas Fireplace Insert | 17
Page 18
18
|
installation
MODIFICATION OF MONTIGO EP28-2, EP28-4
OR EP28-5
*Units could have any of the following Log Sets Installed: 2LB (2 Log Set),
MB (2 Log Set), 4LB (4 Log Set)
1. Turn off unit, disconnect Gas and Power.
2. Remove Upper and Lower Louvers.
3. Remove Optional Doors or Screen Mesh.
4. Remove Logs.
5. Remove Bottom Door Rail (See Diagram 5.1).
6. Remove Burner Assembly (See Diagram 5.1).
8. Remove hood and inner baffle (See Diagram 5.3).
Diagram 5.3
9. Bend down the three flanges at the bottom of the firebox or cut them off
(See Diagram 5.4).
Diagram 5.1
7. Cut the front bar out on the left and right sides of the firebox. (See
Diagram 5.2). Grind the corners smooth on the left side - to reduce the
risk of wires being cut. Alternate method is to cut front bar in the center
and break off each side spot weld completely.
Grind corners
Diagram 5.2
Diagram 5.4
Modied edges must be ush to allow proper seating of the E18E
outer shell.
18 | Regency
®
E18E Gas Fireplace Insert
Page 19
E18E INSTALLATION SPECIFICATIONS
DETAIL A
SCALE 1 : 4
Leg height setting
EP28 Installation Specifications
5 5/8"
143mm
8 7/16"
215mm
1 7/16"
37mm
A
EP28 Firebox
DETAIL A
SCALE 1 : 4
Leg height setting
EP28 Installation Specifications
Leg Setting / Outer Shell Position
See Installation of E18E into Existing Units for General Installation Guidance - for vent connection configuration.
installation
|
19
This install of the E18E uses
Vent Connection Type A.
The length of 4" Flex needed is 4 -1/8" semi-expanded.
Secure flue adapter top plate to under side of existing firebox using 4 self tapping screws.
The height of the unit installed is shown below.
EP28-4 / EP28-5 INSTALLATION SPECIFICATIONS
E18 Insert
Secure top plate to rebox w/4 screws.
4 1/8"
105mm
EP28 Firebox
Flex Adaptor Length
Adaptor Plate
Set to this
fastener setting
1/4"
6mm
B
DETAIL B
SCALE 1 : 4
hole
Secure vent slide plate to ex pipe with 4
screws
Collar Plate Setting / Vent position
EP28 Firebox
8 7/16"
215mm
1 7/16"
37mm
5 5/8"
143mm
A
Right side shown
1. Loosen 2 x Phillips screws on both right and left legs.
2. See above diagram below for required leg setting.
3 Install with supplied Phillips screws to pre-punched holes and tighten previous screws that were loosened in Step 1.
4. Keep left side leg loose until outer firebox is in position in ZC box - to allow adjustment of gas line.
Set to this
hole
Regency
®
E18E Gas Fireplace Insert | 19
Page 20
20
|
installation
MODIFICATION OF MONTIGO EP28-S2
*S2 comes with a 6 piece Log Set.
1. Turn off unit and Disconnect Gas.
2. Remove Top and Bottom Louvers.
3. Remove Glass Door (See Diagram 6.1).
5. Remove Front Bar (See Diagram 6.3).
Diagram 6.3
6. Remove Primary and Secondary Limit Switches (See Diagram 6.4).
Diagram 6.1
4. Remove Side Filler Plates and Front Hood (See Diagram 6.2).
Diagram 6.4
7. Remove Insert (See Diagram 6.5).
Diagram 6.2
20 | Regency
®
E18E Gas Fireplace Insert
Diagram 6.5
Page 21
installation
|
21
8. Remove Efficiency Collar (See Diagram 6.6).
Diagram 6.6
9. Remove Fan (See Diagram 6.7).
11. Bend Down the Three Flanges at the Bottom of the Firebox or Cut them
Off (see Diagram 6.9).
Diagram 6.9
Edges must be ush to allow proper seating of the
E18E outerbox.
E18E INSTALL SPECIFICATIONS
Diagram 6.7
10. Remove the leftover ends of the front bar on the Left and Right sides so
that they are flush with the sides of the firebox. (See Diagram 6.8)
See Installation of E18E into Existing Units for General Installation
Guidance.
This install of the E18E uses Vent Connection Type A.
The Length of 4" Flex needed is approximately 4-1/8" semi-expanded.
From this point installation is the same as the EP28-5.
Diagram 6.8
Regency
®
E18E Gas Fireplace Insert | 21
Page 22
22
|
installation
MODIFICATION OF MONTIGO
ECONO PLUS 28C
1. Turn off unit and Disconnect Gas.
2. Remove Top Louver Bars.
3. Remove Mesh Door Frame by removing 7 screws (See Diagram below).
Remove 7 screws - remove Mesh Door Frame (if installed).
4. Remove Upper Bracket by removing 2 screws.
6. Remove heat deflector by removing 3 bolts and nuts.
Remove 3 bolts and nuts to remove heat deector.
7. Remove the rear baffle.
Remove 2 screws - remove Top Bracket
5. Remove Bracket and Thermodisc by removing 2 screws.
Remove 2 screws - remove Thermodisc Bracket
Remove rear bae.
8. Remove 2 bolts from underneath, to remove valve, log tray, etc.
9. Lift entire assembly out.
Remove 2 bolts
22 | Regency
®
E18E Gas Fireplace Insert
Page 23
installation
|
23
10. Remove Serial No. Decal attached to valve assembly and affix to wall of
28C firebox.
Montigo Serial Decal
11. Flatten left and right louver brackets.
13. Cut to remove left and right cross piece at front of firebox.
Cut out front cross piece to remove
14 Cut out back cross bar to complete modification. Fold back any excess
metal after removing the cross piece.
Flatten louver brackets
12. Flatten flange (left ,right and rear) in locations shown below.
Regency
Cut out back cross bar
®
E18E Gas Fireplace Insert | 23
Page 24
24
|
15. Prior to installing faceplate - use a #30 drill bit to remove upper trim /
16. Install outer faceplate to use as a template for measurements - ensure
installation
Completed modication
heat shield from outer faceplate.
outer Faceplate is centered, mark and drill 2 holes per side. The pre
drilled holes should line up with the outer shell holes. Remove outer
faceplate and continue with E18E installation.
Install outer faceplate
24 | Regency
®
E18E Gas Fireplace Insert
Page 25
installation
5 5/8"
143mm
8 7/16"
215mm
1 7/16"
37mm
A
EP28 Firebox
DETAIL A
SCALE 1 : 4
Leg height setting
EP28 Installation Specifications
Leg Setting / Outer Shell Position
8- 1/8"
206mm
5- 1/4"
133mm
1 1/2"
39mm
A
Montigo 28C Firebox
DETAIL A
SCALE 1 : 4
Leg height setting
28-F & 28F-2 Installation Specications
|
MONTIGO ECONO PLUS 28C INSTALLATION SPECIFICATIONS
E18E INSTALL SPECIFICATIONS
See Installation of E18E into Existing Units for General Installation Guidance for Vent Configuration.
This install of the E18E uses Vent Connection Type A.
The Length of 4" Flex needed is 4-1/8" semi-expanded. Secure flue adapter top plate to under side of existing firebox using 4 self taping
screws.
4 1/8"
105mm
25
Secure top plate to rebox w/4 screws.
Secure vent slide plate to ex pipe with 4
screws
E18 Insert
Montigo Econo Plus 28C
Firebox
B
EP28 Firebox
Collar Plate Setting / Vent position
1/4"
6mm
Set to this
hole
Flex Adaptor Length
Set to this
hole
Adaptor Plate fastener setting
DETAIL B
SCALE 1 : 4
Right side shown
1. Loosen 2 x Phillips screws on both right and left legs.
2. See above diagram below for required leg setting.
3. Install with supplied Phillips screws to prepunched holes and tighten previous screws that were loosened in
Step 1.
4. Keep left side leg loose until outer firebox is in position in ZC box - to allow adjustment of gas line.
Regency
®
E18E Gas Fireplace Insert | 25
Page 26
26
|
installation
MODIFICATION OF MONTIGO 28F-2 OR 28-F
1. Turn off unit, disconnect gas and power.
2. Remove Top and Bottom Louvers.
3. Remove Screen Mesh (See Diagram 7.1) or Bifold Doors.
6. Disconnect Pilot Gas Line and Pilot Thermopile from the Valve.
Disconnect Thermostat wires from valve.
Diagram 7.3
7. Disconnect Valve from the Main Burner Line (See Diagram 7.4).
Diagram 7.1
4. Remove Logs and Sand from Sand Pan.
5. Remove Front Bar. (See Diagram 7.2).
Diagram 7.2
Diagram 7.4
8. Unscrew left and right side nuts, under the firebox, holding down
the Sand Pan. (see Diagram 7.5)
26 | Regency
®
E18E Gas Fireplace Insert
Diagram 7.5
Page 27
installation
|
27
9. Remove Sand Pan and Pilot Assembly.
Diagram 7.6
10. Cut out the Bottom of the Firebox (See Diagram 7.7)
Cut must be clean - with Max. 1/4" of material left.
12. Bend Top Face Down (See Diagram 7.9).
Diagram 7.9
13. Measure and draw a line 1" below the bottom of the exhaust
collar (See Diagram 7.10).
Diagram 7.10
Diagram 7.7
11. Cut the Sides of the Top Face (See Diagram 7.8).
14. Cut the Sides of the Top of the Firebox Flush with the Sides of
the Firebox and Cut the Top of the Firebox 1” below the bottom
of the Exhaust Collar (See Diagram 7.11 and 7.12).
Diagram 7.11
Diagram 7.8
Regency
Diagram 7.12
®
E18E Gas Fireplace Insert | 27
Page 28
28
|
installation
14. Bend the Louver Mounts Flat. (See Diagram 7.13)
Diagram 7.13
15. Final Firebox Should Look Like Diagram 7.14.
Diagram 7.14
Modied edges must be ush to allow proper seating of the E18E
outerbox.
28 | Regency
®
E18E Gas Fireplace Insert
Page 29
installation
7 3/16"
183mm
6 1/16"
155mm
1 1/2"
39mm
A
DETAIL A
SCALE 1 : 4
Leg height setting
fastener setting
28-F & 28F-2 Installation Specifications
Leg Setting / Outer Shell Position
7 3/16"
183mm
6 1/16"
155mm
1 1/2"
39mm
A
28-F / 28F-2 Firebox
DETAIL A
SCALE 1 : 4
Leg height setting
28-F & 28F-2 Installation Specifications
|
28 F / 28 F2 INSTALLATION SPECIFICATIONS
E18E INSTALL SPECIFICATIONS
See Installation of E18E into Existing Units for General Installation Guidance for Vent Configuration.
This install of the E18E uses Vent Connection Type A.
The Length of 4" Flex needed is 2-5/8" semi-expanded. Secure flue adapter top plate to under side of existing firebox using 4 self taping
screws.
2 5/8"
66mm
29
Secure top plate to rebox w/4 screws.
Secure vent slide plate to ex pipe with 4
screws
E18 Insert
28-F / 28F-2 Firebox
B
Collar Plate Setting / Vent position
Set to this
hole
Flex Adaptor Length
Set to this
Adaptor Plate
hole
DETAIL B
SCALE 1 : 4
1. Loosen 2 x Phillips screws on both right and left legs.
2. See above diagram below for required leg setting.
3. Install with supplied Phillips screws to prepunched holes and tighten previous screws that were loosened in Step 1.
4. Keep left side leg loose until outer firebox is in position in ZC box - to allow adjustment of gas line.
Regency
Right side shown
®
E18E Gas Fireplace Insert | 29
Page 30
30
|
installation
MODIFICATION OF MONTIGO 28F-3
1. Turn off unit, disconnect gas and power.
2. Remove Top and Bottom Louvers.
3. Remove Screen Mesh (See Diagram below) or Bifold Doors.
Diagram 1
6. Disconnect valve from main burner Line (See Diagram 3).
Diagram 3
7. Unscrew left and right side nuts, under the firebox, holding down
the Sand Pan. (see Diagram 4)
4. Remove Logs and Sand from Sand Pan.
5. Disconnect Pilot Gas Line and Pilot Thermopile from the Valve.
Disconnect Thermostat wires from valve.
Diagram 2
Diagram 4
30 | Regency
®
E18E Gas Fireplace Insert
Page 31
8. Remove sand pan and pilot assembly.
installation
Diagram 8
|
31
Diagram 5
9. Cut the plate located at the bottom of the firebox, as shown below.
Diagram 6
Cut here to remove bar
10. Cut out the bottom of the Firebox (See Diagram 7)
Cut must be clean - with Max. 1/4" of material left.
Cut here to remove
11. Unscrew the top bar shown below.
Diagram 9
12. Unscrew the top bar from location shown below.
Diagram 7
Regency
Diagram 10
®
E18E Gas Fireplace Insert | 31
Page 32
32
|
13. Unscrew the plate located between the 2 fixed bars, as shown
14. Unscrew the plate locating underneath, as shown below.
installation
below.
Diagram 11
Diagram 14
16. Remove the inside plate located at the rear of the cut plate.
Diagram 12
15. Unscrew the side* and back plates located in the firebox, as
shown below.
*Not all unit have side plates
Diagram 13
Diagram 15
17. Cut the sides of the top face, as shown below.
Diagram 16
32 | Regency
®
E18E Gas Fireplace Insert
Page 33
installation
|
33
18. Bend top face down (See Diagrams 17 & 18).
Diagram 17
20. Bend the Louver mounts until they lay flush. (See below)
Diagram 20
21. Final modified firebox should look similar to Diagram 21 below.
Diagram 18
19. Cut the sides of the top of the firebox flush with the sides of the
firebox and cut the top of the firebox 1” below the bottom of the
exhaust collar (See Diagram 19 below).
Diagram 19
Diagram 21
Regency
®
E18E Gas Fireplace Insert | 33
Page 34
34
7 3/16"
183mm
6 1/16"
155mm
1 1/2"
39mm
A
DETAIL A
SCALE 1 : 4
Leg height setting
fastener setting
2 5/8"
66mm
28-F & 28F-2 Installation Specifications
Leg Setting / Outer Shell Position
7 3/16"
183mm
6 1/16"
155mm
1 1/2"
39mm
A
28-F-3 Firebox
DETAIL A
SCALE 1 : 4
Leg height setting
28-F-3 Installation Specications
|
installation
28F-3 INSTALLATION SPECIFICATIONS
E18E INSTALL SPECIFICATIONS
See Installation of E18E into Existing Units for General Installation Guidance for Vent Configuration.
This install of the E18E uses Vent Connection Type A.
E18 Insert
28-F / 28F-2 Firebox
B
Flex Adaptor Length
Collar Plate Setting / Vent position
Adaptor Plate
DETAIL B
SCALE 1 : 4
Set to this
hole
Set to this
hole
1. Loosen 2 x Phillips screws on both right and left legs.
2. See above diagram below for required leg setting.
3. Install with supplied Phillips screws to prepunched holes and tighten previous screws that were loos-
ened in Step 1.
4. Keep left side leg loose until outer firebox is in position in ZC box - to allow adjustment of gas line.
34 | Regency
®
E18E Gas Fireplace Insert
Right side shown
Page 35
installation
|
35
MODIFICATION OF MONTIGO 36SR
*MUST USE FULL LENGTH LINER 4"
1. Turn off the unit and Disconnect Gas and Power.
2. Remove Top and Bottom Louvers.
Diagram 8.1
6. Remove Air Inlet Strip (See Diagram 8.3).
Diagram 8.3
3. Remove Glass Doors and Screen Mesh (See Diagram 8.1).
4. Remove Logs and Sand from Sand Pan.
5. Remove Top Rail securing the Bifold Doors (See Diagram 8.2).
Diagram 8.4
7. Remove Brick Liner Panels (See Diagram 8.4).
Diagram 8.2
Regency
Diagram 8.5
®
E18E Gas Fireplace Insert | 35
Page 36
36
|
installation
8. Unscrew and Remove Trim Around Sand Pan (See Diagram
8.5).
9. Disconnect Pilot Gas Line and Pilot Thermopile from Valve.
10. Disconnect Valve from Main Burner Gas Line.
11. Remove Plate On the Bottom of the Firebox where Pilot Enters.
(See Diagram 8.6)
Diagram 8.6
12. Unscrew Left and Right Nuts Underneath the Firebox Holding
Down the Sand Pan. (See Diagram 8.7)
14. Unscrew the Bottom of the Firebox. (See Diagram 8.8)
Diagram 8.8
15. Unscrew the Firebox Top Front Flange, making sure to place the
Top Left and right corner screws back in (See Diagram 8.9 and
8.10).
13. Remove Sand Pan and Pilot Assembly.
Diagram 8.7
Diagram 8.9
36 | Regency
®
E18E Gas Fireplace Insert
Diagram 8.10
Page 37
installation
|
37
16. Remove Louver Supports in all 4 corners of the Appliance (See
Diagram 8.11).
Diagram 8.11
17. Final firebox should look like Diagram 8.12.
Diagram 8.12
Modied edges must be ush to allow proper seating of the E18E
outerbox.
Regency
®
E18E Gas Fireplace Insert | 37
Page 38
38
6 15/16"176mm
6 3/8"
162mm
1 9/16"
40mm
A
36SR Firebox
DETAIL A
SCALE 1 : 4
Leg height setting
Montigo 36SR Installation Specifications
DETAIL A
SCALE 1 : 4
Leg height setting
Montigo 36SR Installation Specifications
|
installation
E18E INSTALL SPECIFICATIONS
See Installation of E18E into Existing Units for General Installation Guidance.
This install of the E18E uses a full length 4" liner.
The Length of 4" Flex needed depends on the height of the B vent chimney.
Leg Setting / Outer Shell Position
76mm
3"
Secure top plate to rebox w/4 screws.
Secure vent slide plate to ex pipe with 4
36SR Firebox
screws
E18 Insert
36SR Firebox
B
Flex Adaptor Length
1 1/2"
37mm
Adaptor Plate fastener setting
DETAIL B
SCALE 1 : 4
Set to this
hole
Collar Plate Setting / Vent position
6 3/8"
162mm
Set to this
hole
6 15/16"
176mm
1. Loosen 2 x Phillips screws on both right and left legs.
2. See above diagram below for required leg setting.
3. Install with supplied Phillips screws to prepunched holes and tighten previous screws that were loosened in Step 1.
4. Keep left side leg loose until outer firebox is in position in ZC box - to allow adjustment of gas line.
38 | Regency
®
E18E Gas Fireplace Insert
A
1 9/16"
40mm
Right side shown
Page 39
installation
|
39
MODIFICATION OF FIRESONG 220N
1. Turn off and Disconnect Gas and Power.
2. Remove Valve Cover (See Diagram 9.1).
4. Unscrew and Remove Front Inner Baffle (See Diagram 9.3).
Diagram 9.3
5. Cut the Sides of the Rear Inner Baffle at the Back of the Firebox
(See Diagram 9.4).
Diagram 9.1
3. Remove the Bottom of the Firebox and Sand Pan in one assembly (See Diagram 9.2).
Diagram 9.4
6. Bend the Inner Rear Baffle up so it is flush with the back of the
Firebox or cut off the Baffle if it will not bend flat with the back of
the Firebox.
Diagram 9.2
Regency
®
E18E Gas Fireplace Insert | 39
Page 40
40
|
installation
7. Cut The Top Front Flange of the Firebox (See Diagram 9.5).
Diagram 9.5
8. Cut off support tab at the top of the firebox and final firebox
should look like Diagram 9.6.
Diagram 9.6
Modied edges must be ush to allow proper seating of the
E18E outerbox.
40 | Regency
®
E18E Gas Fireplace Insert
Page 41
installation
DETAIL C
SCALE 1 : 4
Leg height setting
1 15/16"
Firesong 220N Installation Specifications
5 1/4"
133mm
8 3/16"
208mm
2 1/8"
54mm
C
E18 Insert
DETAIL C
SCALE 1 : 4
Leg height setting
D
E18 Insert
Firesong 220N Firebox
Vents on center
DETAIL D
SCALE 1 : 4
Adaptor PlateFastener Setting
1 15/16"
49mm
Firesong 220N Installation Specifications
Leg Setting / Outer Shell Position
Flex Adaptor Length
Collar Plate Setting / Vent position
|
E18E Install Specifications
See Installation of E18E into Existing Units for General Installation Guidance.
This install of the E18E uses Vent Connection Type A.
The Length of 4" Flex needed is 1-15/16" semi-expanded. Secure flue adapter top plate to under side of existing firebox using 4 self tap-
ing screws.
41
Secure top plate to rebox w/4 screws.
Secure vent slide plate to ex pipe with 4
Firesong 220N Firebox
5 - 3/16"
[132mm]
screws
2 1/8"
54mm
Leg Setting / Outer Shell Position
5 1/4"
133mm
E18 Insert
C
8 3/16"
208mm
Set to this
hole
Set to this
hole
Firesong 220N faceplate is an outside fit, if the front metal face
of the 220N is covered with stone or tile - a custom faceplate
will be required.
The following measurements of the 220N metal face will be
visible if no stone or tile is covering it. If this metal face is visible, the standard Faceplate (616-920) will fit.
1"
(25mm)
Front Facing measurements
Firesong 220N
3"
(76mm)
3"
(76mm)
Note: this measurement
is above lower area
1. Loosen 2 x Phillips screws on both right and left legs.
2. See above diagram below for required leg setting.
3. Install with supplied Phillips screws to prepunched holes and tighten previous
screws that were loosened in Step 1.
4. Keep left side leg loose until outer firebox is in position in ZC box - to allow
adjustment of gas line.
Regency
Right side shown
®
E18E Gas Fireplace Insert | 41
Page 42
42
|
installation
MODIFICATION OF FIRESONG 120N
1. Turn off gas supply, if unit has a fan - turn off and disconnect power.
2. Remove Top Trim Pieces and Glass Doors- if installed (See
Diagram 10.1).
Diagram 10.1
3. Remove Lower Trim piece and Bottom Panel. (See Diagram
10.2).
6. Unscrew and Remove Trim Around Sand Pan (See Diagram
10.4).
Diagram 10.4
7. Remove Logs (See Diagram 10.5).
Diagram 10.2
4. Remove Top Rail securing Mesh. (See Diagram 10.3).
5. Shut off and disconnect gas line from valve.
Diagram 10.5
8. Remove screw on right side to remove sand pan and base.
(See Diagram 10.6).
Diagram 10.6
9. Remove Valve.
10. Make 2 vertical cuts on Top Facing. (See Diagram 10.7).
Diagram 10.3
42 | Regency
®
E18E Gas Fireplace Insert
Diagram 10.7
Page 43
11. Remove Top Front Flange of Firesong firebox. (See Diagram
10.8).Remove tabs on right and left side of firebox.
Diagram 10.8
12. Cut out mid section of Firesong firebox . (See Diagram 10.9).
Cut off bar at back of firebox.
installation
14. Cut out right side of existing Firesong firebox. (See
Diagrams 10.11,10.12 and 10.13). Left and right cutout begins
on front face - see Diagram 10.12
IMPORTANT: Cut out Firesong firebox and install support one side
at a time.
Diagram 10.11
|
43
Back bar
Diagram 1.9
Diagram 10.9
13. Remove 6 screws, one at a time, and replace with pan head
(wafer screws) - in locations shown below.
Diagram 10.12
Diagram 10.10
Regency
Diagram 10.13
®
E18E Gas Fireplace Insert | 43
Page 44
44
|
15. Install supplied support section with 8 screws to reinforce
installation
Firesong firebox. (See Diagram 10.14).
Diagram 10.14
18. Final modified firebox should look like Diagram 10.16
NOTE: Shown with flue collar and 6" length of flex installed.
Firesong decal axed
Diagram 10.16
IMPORTANT NOTE:
Separate inner and outer firebox on E18E (see instructions in this
manual) Before installing outer firebox - lay on a flat surface and
trim off 1-1/4" of each firebox fastening flange as shown below.
16. Repeat Steps 14 & 15 on left side.
17. Remove existing Firesong rating plate from cut out firebox.
This rating plate must be retained and affixed to the unit. (See
Diagram 10.15 and 10.16).
Diagram 10.15
44 | Regency
®
E18E Gas Fireplace Insert
Page 45
installation
2 1/8"
DETAIL C
SCALE 1 : 4
Leg height setting
Firesong 220N Installation Specifications
5 5/8"
143mm
8 7/16"
215mm
1 7/16"
37mm
A
EP28 Firebox
DETAIL A
SCALE 1 : 4
Leg height setting
EP28 Installation Specifications
Leg Setting / Outer Shell Position
|
E18E INSTALLATION SPECIFICATIONS
See Installation of E18E into Existing Units for General Installation Guidance - for vent connection configuration.
The length of 4" Flex needed is 6" semi-expanded.
Remove top flue adaptor from unit by removing 1 Philips screw and slide backward. Adjust flue adaptor length by resetting screw from Set 4 to Set 8 - see
Diagram below. Attach 4" flex to flue adaptor and insert into existing 5" vent - shown below.
Procedure to adjust the height of the outer firebox installed is shown below.
FIRESONG 120N INSTALLATION SPECIFICATIONS
4 1/8"
6"
105mm
(152mm)
Firesong 120 rebox
E18 Insert
EP28 Firebox
Flex Adaptor Length
45
Secure vent slide plate to ex pipe with 4
screws
Firesong 120 Firebox
Firesong 220N Firebox
4-5/8"
5 - 3/16"
[132mm]
[117mm]
5 1/4"
133mm
B
Collar Plate Setting / Vent position
E18 Insert
8 3/16"
6-1/8"
208mm
[156mm]
C
1/4"
6mm
Adaptor Plate
Set to this
fastener setting
DETAIL B
SCALE 1 : 4
hole
Flue adaptor
setting
Set to this
hole
1/2"
[13mm]
1. Loosen 2 x Phillips screws on both right and left legs.
2. See above diagram below for required leg setting.
3 Install with supplied Phillips screws to pre-punched holes and tighten previous screws that were loosened in Step 1.
4. Keep left side leg loose until outer firebox is in position in ZC box - to allow adjustment of gas line.
See Step #2: Outer Shell installation for procedure.
Regency
Right side shown
®
E18E Gas Fireplace Insert | 45
Page 46
46
Adaptor Plate Gasket
|
installation
INSTALLATION OF THE E18E INTO EXISTING UNITS
STEP #1: VENT CONNECTION TYPE A
1. Attach the Flex Vent Section to the Adaptor Plate using 3
self drilling sheet metal screws.
2. Using 4 Sheet Metal Screws, attach the Adaptor Plate,
Vent Section and Adaptor Plate Gasket to the top of the
existing Fire Box.
See specific instructions to your installation to determine what
position the Adaptor Plate should be located.
3. Attach the Slide Plate Retainer to the Vent Slide Plate using the
setting outlined in your unit specific installation guide.
4. Using the 3 self drilling sheet metal screws,
attach the Vent Slide Plate to the Flex Vent Section
THE APPLIANCE MUST
NOT BE CONNECTED TO A
CHIMNEY FLUE SERVING
A SEPARATE SOLID FUEL
BURNING APPLIANCE.
Adaptor Plate
Sheet Metal
Screws
Flex Vent Section
Vent Slide Plate
Slide Plate Retainer
STEP #1: VENT CONNECTION
(FIRESONG 120N)
1. Attach the Flex Vent Section to the Adaptor Plate using 3
self drilling sheet metal screws.
Diagram 11.1
Diagram 11.2
46 | Regency
®
E18E Gas Fireplace Insert
Page 47
Vent Slide Plate
Vent Slide Plate
Step #2: Outer Shell Installation
The E18 was designed to be installed in a modular fashion, making it easier for the installer to locate and install the various components without having to support the weight of the entire appliance. The Wire Harness comes installed from factory in order that no connections need to be made in the field.
1) Slide the Outer Shell rearward and into the existing firebox being carefull to make sure that the Vent Slide Plate is properly engaged in the slide provisions of the Outer Shell. Move the Outer Shell rearward until the left and right flanges are up against the existing firebox.
2) Adjust the Outer Shell Legs down to the setting noted for your specific installation. If these settings are not correct, the Surround Panels will not fit correctly in your particular installation.
STEP #2: OUTER SHELL INSTALLATION
1. Slide outer shell back into the existing firebox, ensure the vent slide
plate is properly engaged with the outer shell.
Move the outer shell back until the left and right flanges contact
the existing firebox.
2. Adjust the outer shell legs to the setting noted for your specific
installation. If these settings are not adhered to, the surround will not fit
correctly.
3. Attach the vent slide plate to the outer shell with one sheet metal
screw as shown in Figure 12.1. Refer to the applicable existing appli-
ance for correct measurements before securing outer shell in position.
Existing Firebox
Leg Height
installation
attachement screw
|
47
4. Ensure the unit is set at the correct height and the outer shell is square
and centered, fasten the outer shell to the existing firebox using self
tapping screws.
STEP #3: FIREBOX INSTALLATION
1. Ensure thermodiscs and thermodisc brackets are in
place.
2. Install the firebox into the outer shell by sliding the
drafthood bottom onto the drafthood slide until you are
able to install 4 screws to secure the firebox. Use care
to avoid damaging the wire harness.
Note: 2 of the screws along with panel brackets to be
installed on the lower inside of the firebox.
3. Unit is installed correctly when the flanges that se-
cure the firebox to the outer shell contact. Ensure the
unit is centered within the existing firebox, attach the
outer shell to the existing firebox using 4 x sheet metal
screws.
4. Install 2 self tapping screws at the front edge corners of
the drafthood bottom to secure the drafthood.
5. Install 1 x Phillips screw to fasten drafthood. Install 2 x
Phillips screws to secure left and right side of thermo-
disc bracket.
Regency
Outer Shell Screws (x4)
Outer Shell Legs (x2)
Fastening Screws
Diagram 12.1
Drafthood Slide
Upper Drafthood
Baffle
Wire Harness
Surround
Mounting
Bracket
Left
Control Box
Surround Mounting
Diagram 12.2
ZC box existing UnitMeasured from
Top of ZC box
EP288-7/16" (215mm)1-7/16" (37mm)
28F - 28F27-3/16" (183mm)1-1/2" (39mm)
Montigo 36SR6-3/8" (162mm)1-9/16" (40mm)
Firesong 220N8-3/16" (208mm)2-1/8" (54mm)
®
Bracket Right
Measured from side of
E18E Gas Fireplace Insert | 47
ZC box
Drafthood
Bottom
Page 48
48
E18
SURROUND INSTALLATION
|
installation
STEP #4: SURROUND INSTALLATION
ONLY TRIM KIT SUPPLIED BY THE MANUFACTURER SHALL BE
USED IN THE INSTALLATION OF THIS APPLIANCE.
1. Remove glass door and screen from unit by removing 2 screws.
See below.
Retainer ScrewsDiagram 13.1
2. Remove control box from rear surround by removing 2 screws.
Disassemble control box, insert both fan control switch, fan
control knob and on/off switch. Attach yellow and red wires to
on/off switch as shown below and connect 2 female wires from
fan speed control to 2 male wire connectors from wiring harness
at appliance. Reassemble control box.
NOTE: The fan speed control is secured using a lock nut. The on/
off switch is simply snapped into position and control knob slides
over the fan control switch. Note the orientation of the on/off switch
wires. See diagrams below.
3. Run wire harness from unit through notch in mounting bracket
and then to control box as shown below.
Notch in
mounting
bracket
Diagram 13.3
4. Attach control box to left mounting bracket with 2 screws.
NOTE: The screws are only a guide and do not fasten the bracket.
The backing plate keeps the control box in place for ease of
service.
5. Tu ck wire harness on left top groove and secure with wire
clips.
6. Feed power cord through left grommet. (If power outlet is
on the right side of the unit, feed power cord through right
grommet and use wire grommets to secure power cord inside
the unit). See diagram 13.4.
7. Secure backing plate with mounting brackets to outer box
by screwing 4 self tapping screws on fl anges.
2 female wires
Yellow wire
48 | Regency
Red wire
Diagram 13.2
®
E18E Gas Fireplace Insert
Power cord
(911-245) through
supplied grommet
Diagram 13.4
Page 49
E18
8. Attach front faceplate with 4 screws (2 on each mounting
bracket). (Touch up screws with black paint, after install.)
Diagram 13.5
9. Reinstall glass door and screen removed from step 1.
10. Locate the 'DC supply' wire on the wiring harness, the wire
will be clearly marked. Attach the AC adaptor to the DC
supply wire as shown. Do not plug into a 120V circuit until
the install is complete.
installation
MONTIGO 28 F3 ONLY
12. To install fi ller piece, slide under faceplate and secure to
backside of faceplate with magnets.
13. Completed install of fi ller piece.
|
49
AC adaptor
11. Install control cover, adjust horizontal alignment by sliding
control cover to ensure even spacing on both sides. Ensure
control cover is seated down all the way.
Diagram 13.7
DC supply wire from wiring harness
Diagram 13.6
Regency
®
E18E Gas Fireplace Insert | 49
Page 50
50
ZERO CLEARANCE FACEPLATE INSTALLATION
E18E
|
installation
ZERO CLEARANCE FACEPLATE INSTALLATION
1. Shut down existing unit and allow to cool to room temperature.
2. Turn off gas supply and disconnect electrical.
3. Remove all accessories from existing unit, ie. glass doors, louvers,
etc.
4. Remove any tiles, hearth or surround from existing unit (if required).
5. Disconnect gas supply from existing unit.
6. Cut away a perimeter of drywall around the existing unit to expose
the framing. See example below.
Electrical connection: 110v required
Fan must be on at all times to operate this unit.
1RWH$OOIUDPLQJPD\
EHRIZRRGFRQVWUXFWLRQ
DescriptionE18E
Cut drywall
7. Uninstall existing unit from framing.
Remove unit from framing
8. Disconnect venting from existing unit - remove carefully to avoid damage.
9. Remove existing unit from framed opening.
$
%
&
)LQLVKHG)ORRU
10. Measure framed opening and compare to dimension requirements.
Additional adjustments to framed opening may be required.
50 | Regency
®
E18E Gas Fireplace Insert
Page 51
installation
,QQHUER[
2XWHUER[
1. When framing is complete, ensure wiring is installed by an electrician
prior to installing the unit.
2. Assemble ZC surround with 8 (904-897) screws provided in locations
shown below.
3. Secure surround to the stud on each side with wood screws (not supplied).
Assemble the ZC
surround with 4
screws on each
side.
Use 4 screws on each side to secure
surround to studs.
E18E
|
51
ZERO CLEARANCE FRAMING
When installing the E18E as a zero clearance, you will use the
framing clearances in the following diagrams. Mantel and inside corner
clearances can be found in Minimum Clearances to Combustibles.
ZERO CLEARANCE INSTALLATION
Regency
®
E18E Gas Fireplace Insert | 51
Page 52
52
K
E18E
|
installation
4. ZC surround installed into framed opening.
5. Separate E18E inner and outer fi reboxes - see installation into existing
unit section in the manual for details.
6. Set E18E outside fi rebox legs as shown below.
Set to this
hole
7. Follow instructions in the manual for installation into a EP28-2 for
exact measurements for installation of the outside fi rebox to the surround.
Secure outer fi rebox to the ZC faceplate
using 2 (904-897 )screws per side
(3)LUHER[
Secure with
2 screws
per side
8. The top panel of the ZC surround may be removed to ease the installa-
tion of the venting - reinstall top panel after venting is installed.
* Extra venting may be required--which is not included.
PP
$
PP
PP
/HJ
measurements (Step 7) before securing to surround.
52 | Regency
Right side shown
Outside fi rebox shown in position - refer to
®
E18E Gas Fireplace Insert
9. Follow instructions in the installation into existing unit section in the
manual to complete the install of inner fi rebox.
Follow Step 10 before installing faceplate.
10. Install lower trim piece with 2 (904-897) screws to the bottom of
the ZC surround before installing faceplate.
Page 53
installation
E18E
|
53
FACEPLATE INSTALLATION
ONLY TRIM KIT SUPPLIED BY THE MANUFACTURER SHALL BE
USED IN THE INSTALLATION OF THIS APPLIANCE.
1. Remove glass door and screen from unit by removing 2 screws.
See below.
Retainer ScrewsDiagram 13.1
2. Remove control box from rear surround by removing 2 screws.
Disassemble control box, insert both fan control switch, fan
control knob and on/off switch. Attach yellow and red wires to
on/off switch as shown below and connect 2 female wires from
fan speed control to 2 male wire connectors from wiring harness
at appliance. Reassemble control box.
NOTE: The fan speed control is secured using a lock nut. The on/
off switch is simply snapped into position and control knob slides
over the fan control switch. Note the orientation of the on/off switch
wires. See diagrams below.
3. Run wire harness from unit through notch in mounting bracket
and then to control box as shown below.
Notch in
mounting
bracket
Diagram 13.3
4. Attach control box to left mounting bracket with 2 screws.
NOTE: The screws are only a guide and do not fasten the bracket.
The backing plate keeps the control box in place for ease of
service.
5. Tu ck wire harness on left top groove and secure with wire
clips.
6. Feed power cord through left grommet. (If power outlet is
on the right side of the unit, feed power cord through right
grommet and use wire grommets to secure power cord inside
the unit). See diagram 13.4.
7. Secure backing plate with mounting brackets to outer box
by screwing 4 self tapping screws on fl anges.
2 female wires
Yellow wire
Red wire
Diagram 13.2
Regency
Power cord
(911-245) through
supplied grommet
Diagram 13.4
®
E18E Gas Fireplace Insert | 53
Page 54
54
E18E
|
installation
8. Attach front faceplate with 4 screws (2 on each mounting
bracket). (Touch up screws with black paint, after install.)
Diagram 13.5
9. Reinstall glass door and screen removed from step 1.
10. Locate the 'DC supply' wire on the wiring harness, the wire
will be clearly marked. Attach the AC adaptor to the DC
supply wire as shown. Do not plug into a 120V circuit until
the install is complete.
MONTIGO 28 F3 ONLY
12. To install fi ller piece, slide under faceplate and secure to
backside of faceplate with magnets.
13. Completed install of fi ller piece.
AC adaptor
11. Install control cover, adjust horizontal alignment by sliding
control cover to ensure even spacing on both sides. Ensure
control cover is seated down all the way.
Diagram 13.7
DRAFT RELIEF OPENINGS MUST NOT BE COVERED OR BLOCKED.
54 | Regency
®
E18E Gas Fireplace Insert
DC supply wire from wiring harness
Diagram 13.6
Page 55
installation
|
55
Optional
WALL THERMOSTAT
A wall thermostat may be installed if desired,
connect the wires as per the wiring diagram.
Use table below to determine the maximum
wire length.
Note: Preferable if the thermostat is
installed on an interior wall.
Regency® offers an optional programmable
thermostat but any 250-750 millivolt rated nonanticipator type thermostat that is CSA, ULC or
UL approved may be used.
CAUTION
Do not wire millivolt
wall thermostat wires
to 120V wire.
Thermostat Wire Table
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire SizeMax. Length
14 GA.50 Ft.
16 GA.32 Ft.
18 GA.20 Ft.
20 GA.12 Ft.
22 GA.9 Ft.
Optional
REMOTE CONTROL
Use the Regency® Remote Control Kit approved
for this unit. Use of other systems may void your
warranty.
The remote control kit comes with a hand held
transmitter and receiver.
See Wiring Diagram for
Remote installation
Receiver cannot be wall mounted, receiver to be
installed in the fireplace.
1 Install 3 AAA alkaline batteries in transmitter
and 4 AA alkaline batteries in the receiver.
Switch the remote receiver to "remote" mode.
The remote control is now ready for operation.
2. Receiver to be mounted in the fireplace--can
not be wall mounted.
CAUTION
Do not wire millivolt
remote control wires
to 120V wire.
Optional
WALL SWITCH
1. Run up to 10' of wire through the right or
left side gas inlet opening. Be careful not
to damage wire.
Note: We recommend a maximum of 10'
of wire but if you wish to go with a
longer run, use the Thermostat Wire
Table.
See Wiring Diagram for
Wall Switch installation
CAUTION
Do not wire millivolt
wall switch wire
to 120V wire.
Regency
®
E18E Gas Fireplace Insert | 55
Page 56
56
|
installation
AC POWER ADAPTOR INSTALLATION (FOR SUREFIRE SYSTEMS)
An AC power adaptor MUST be installed as a constant power source for the SureFire system.
IMPORTANT: Do not use the 4-AA batteries in the SureFire receiver.
INSTALL AC ADAPTOR WITH SUREFIRE WALL SWITCH/WALL THERMOSTAT ONLY - (WITHOUT REMOTE)
1. Locate “DC Supply” tag on wire harness (located in the unit).
2. Connect the male end from AC adaptor to the female end
tagged “DC Supply” on wiring harness in unit.
3. Plug AC adaptor into 120V power cord located inside the gas fireplace
firebox).
INSTALL AC ADAPTOR WITH SUREFIRE PROFLAME REMOTE
1. Connect the male end of the AC adaptor (from unit) to the female end
of the wire adaptor (supplied with optional remote) together as shown.
Wire adaptor
2. Locate FCM - COM connector labeled on the Remote wire harness.
AC adaptor
4. Neatly tuck any loose AC Power Adaptor wires underneath / inside
the appliance.
Note: Ensure that wires do not touch the underside of the firebox
(keep wires away from the heat as much as possible).
3. Attach female end of DC supply wire (red/black) from valve wiring
harness located on unit to the male FCM-COM supply wire (red/black)
from remote control wiring harness - be careful not to damage ends.
This only fits one way. Do Not Force in wrong way.
FCM - COMAC adaptor
wire adaptor
4. Plug AC adaptor into 120V wall outlet (or into 120V power cord located
inside the gas fireplace firebox).
FCM - COM
56 | Regency
®
E18E Gas Fireplace Insert
5. Neatly tuck any loose AC Power Adaptor wires underneath / inside
the appliance.
Note: This should only be plugged in when unit is fully installed and
ready for use.
Note: Ensure that wires do not touch the underside of the firebox (keep
wires away from the heat as much as possible).
Page 57
GTM REMOTE INSTALLATION
GTMREMOTEINSTALLATION
E18E
installation
|
57
1. Shut off the gas supply and disconnect all power to the unit.
2. Remove the control cover.
3. Identify short (3” long) brown wire that is attached to the white wire
coming from the DFC. Remove the 3” brown wire and discard.
4. Connect the Green wire from the GTM wire harness to the brown,
connect the white wire from the same harness to white.
Discard
3” brown
wire
Brown to
Green
6. Remove the hi/lo knob if installed by removing 2 screws as
shown below.
7. Install the stepper motor in the same location the hi/lo knob was
removed from - with 2 screws as shown below.
5. See AC adaptor install instructions in this manual.
8. Plug wiring harness into back of receiver as shown below.
White
to
White
9. Plug the stepper motor into the ‘motor wire as shown below.
Motor Wire
Regency
®
E18E Gas Fireplace Insert | 57
Page 58
58
E18E
|
installation
10. To unattach these wires - un-clip from the wires on the stepper
motor side as shown below.
Press down this tab
11. Bundle all wires together and clip with supplied wire clip - as
shown below.
12. Attach the receiver to the fl oor of the unit with a velcro pad - also
peel off paper on back side of wire clip and place wires conveniently
in appliance.
13. Switch on left side of faceplate must be in <ON> position.
14. Match the remote control to the receiver - see remote control
instructions.
15. Reverse steps 2 and 1.
58 | Regency
®
E18E Gas Fireplace Insert
Page 59
installation
ConversionfromNGtoLPG
forE18EusingSIT886NOVAGasValve
E18E
CONVERSION KIT 617-969 - NATURAL GAS TO PROPANE USING SIT 886 GAS VALVE
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION !!
|
59
Each Kit contains one LPG
Conversion Kit
LPG Conversion Kit Contains:
1. Turn the unit off and allow it to cool to
room temperature.
2. Unplug or disconnect power source to
stove.
3. Remove glass front (see manual).
4. Remove Log or Glass Burner (see
manual).
5. Unscrew NG burner orifice and replace
with LP orifice.
6. Remove burner orifice with a 1/2" wrench.
Use another wrench to hold on to the elbow
behind the orifice. Discard orifice.
7. Remove pilot retainer clip with pliers and
pull off the pilot cap to expose the pilot
orifice.
Pilot retainer clip
8. Pull off the pilot cap to expose the pilot
orifice.
10. Reinstall new burner orifice LPG stamped
#55 and tighten
11. Remove Hi/Lo pressure regulator by
removing 2 screws as shown below.
Reverse steps to install LP pressure
regulator.
12. Attach the label “This unit has been
converted to LPG” near or on top of the
serial # decal.
13. Replace yellow “NG” label with red “LPG”
label.
14. Reverse steps 3 - 1.
15. Check for gas leaks.
16. Check inlet and outlet pressures.
17. Check operation of flame control.
18. Adjust the burner aeration setting to Fully
Open and adjust as required for the best
flame picture.
Burner Orifice
Burner Orifice
Regency
9. Unscrew the pilot orifice with the allen key;
then replace with the LPG pilot orifice and
the pilot cap, provided in the kit.
19. See manual for Gas Pressure Testing
instructions
Installer Notice:
These instructions must be left with the
appliance.
®
E18E Gas Fireplace Insert | 59
Page 60
60
|
installation
GLASS BURNER INSTALLATION / REMOVAL
1. Angle the Glass Burner up on left side and slide the mixing tube
over the orifice.
Diagram 14.1
2. Make sure to feed the Air Shutter Bar through the lower hole
in the valve tray, just above the ignitor as you place the Glass
Burner in.
3. Screw down the Glass Burner with two screws.
Diagram 14.3
4. Hang the Front Burner Cover on the front edge.
Diagram 14.2
60 | Regency
®
E18E Gas Fireplace Insert
Diagram 14.4
5. To remove--reverse Steps 4-1
Page 61
installation
E18
ENAMEL PANEL INSTALLATION
ENAMEL PANEL INSTALLATION
Black Enamel Panels
• Black Enamel panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time.
Claims for damage after installation will not receive consideration.
• Black Enamel panels will discolor a little during normal operation. This is normal and should not be considered a defect.
All hand and nger marks MUST be cleaned off with a soft cloth. Use an ammonia based cleaner (ie. glass cleaner) to remove any n-
*
gerprints before applying heat to the unit.
Failure to do this will result in burn stains on panels which you will be unable to remove. Not protected by product warranty.
|
61
1. Centre back panel on the back wall of the fi rebox.
2. Slide in side panel into place in lower track.
3. Secure panel in position with panel clip - secure panel clip
with one screw (provided).
Panel Clip
4. Repeat steps 2 & 3 on other side.
Regency
Final Install
®
E18E Gas Fireplace Insert | 61
Page 62
62
|
installation
GLASS CRYSTALS AND OPTIONAL CERAMIC SPA OR VOLCANIC
STONES INSTALLATION ON BURNER AND FIREBOX FLOOR
Evenly spread the Glass Crystals or optional Ceramic Spa Stones over the burner.
Ensure the crystals (or stones) do not overlap too much as this will effect the flame pattern.
IMPORTANT NOTE:
Only the supplied approved Glass Crystals and Ceramic Spa Stones are to be used with these fireplaces. Use of any other type of glass crystals or stones
can alter the unit's performance, any damage caused by the use of any unapproved glass or stones will not be covered under warranty.
When using Ceramic Spa Stones DO NOT cover burner ports or pilot light that lead to pilot flame. Ensure the crystals or stones do not overlap excessively
as this will effect the flame pattern.
NOTE: * Glass Crystals are available in 1lb and 5lb bags.
** Ceramic Spa stone package contains 70 stones
Diagram 15.1
1. Start installing Crystals on back of
3. Spread Crystals evenly over the
NOTE: Correct nal glass installation of Crystals shown in step 3 and 4. The Burner and Firebox Floor should not be visible when the ame is out.
Diagram 15.4
burner and rebox base
4. Ensure Crystals DO NOT block the
front of the pilot hood and ame to
Diagram 15.2
Burner and Firebox Floor
Diagram 15.5
light the burner
2. Distribute Crystals evenly towards
front of Burner and Firebox Floor
Glass Crystals shown on Burner and Firebox Floor
Diagram 15.3
Diagram 15.6
OPTIONAL SPA OR VOLCANIC STONES INSTALLATION (AROUND BURNER)
Diagram 15.7
NOTE: Spa or Volcanic Stones are NOT to be placed anywhere on the burner tube or Pilot assembly area.
62 | Regency
®
E18E Gas Fireplace Insert
Diagram 15.8
Page 63
installation
E18
BRICK PANEL INSTALLATION
|
63
BRICK PANEL INSTALLATION
1. Position back brick panel on the back wall of the fi rebox.
2. Slide in side panel.
5. Repeat steps 2-4 on other side.
Final Install
3. Position panel so that grout line in the panel lines up
with screw in the baffle.
4. If required, lower screw to secure panel in position.
Regency
Line up screw and grout line.
®
E18E Gas Fireplace Insert | 63
Page 64
64
E18
LOG TRAY INSTALLATION
LOG SET INSTALLATION
logs
can
can
|
installation
LOG TRAY INSTALLATION
1. Remove the Log Burner Tray from the box. Hang the front
burner cover on the front edge of the burner tray. Place the Log
Burner Tray on the Glass Burner Tray.
2. Screw the Log Burner Tray to the Glass Burner Tray.
LOG SET INSTALLATION
Installation of Panels must be completed before
installing the log set.
* Log instructions shown with Black Enamel Panels
Read the instructions below carefully and refer to the images. If the
are broken do not use the unit until they are replaced. Broken logs
interfere with pilot operation.
Improper positioning of the logs may create carbon build-up and
alter the unit's performance which is not covered under warranty.
Log Kit #619-935 contains the following pieces:
ARear Log
BFront Left Log
CFront Right Log
DLeft Side Log
ERight Side Log
946-6752lb Fireglass
946-669Platinum Embers
946-708Embaglow Embers
1C Ember Lava
616-515Log Tray Assembly
Screws x 2
3. Install the Log Burner the same way as the Glass Burner (see
installation manual for instructions).
4. Fill the Log Burner with 2lbs of black glass crystals.
1. Place Log A over the two posts at the back of the log burner.
A
2. Place Log B at the front left of the Log Tray.
A
B
64 | Regency
®
E18E Gas Fireplace Insert
Page 65
installation
E18
5.
|
65
Place Log C at the front right of the log tray.
C
Place ember lava, platinum embers, and embaglow on the
burner, being careful not to cover the pilot or the gas ports.
6. Place Log E on the right pin on Log A and on top of Log C.
E
A
C
A
E
D
B
Ember Lava, Embaglow, Platinum Embers
Final Install
Place Log D on the left pin of Log A and the groove in Log B.
D
A
C
B
Regency
®
E18E Gas Fireplace Insert | 65
Page 66
66
E18
E18 - LOG INSTALLATION
|
installation
OPTIONAL LOG SET INSTALLATION
Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken
logs can interfere with pilot operation.
Improper positioning of the logs may create carbon build-up and can alter the unit's performance which is not covered under warranty.
*Satin dark brown paint is included if touch ups are required.
1 Rear Log
2 Left Log
3Right Log
4Front Center Log Piece
5Front Left Log Piece
Log Brackets x 2
6. Install Rear Log (1), center log and rest on both left and right log
brackets with pins facing up.
1
1
Rear log in position
7. Install Log 2 by matching pin locator on Log 2 with left pin on Log 1
as shown below.
2
3
45
1
2
1. S hut off gas and electrical supply, allow unit to cool to room temperature.
2. Remove fl ush glass door (see unit manual).
3. Carefully remove the logs from the packaging and unwrap them.
The logs are fragile, handle with care -never force into position.
4. Ensure glass crystals are installed on the burner.
E18 = 5lbs
5. Install log brackets by clipping brackets to back of burner tray - measure
4" from outside edge of the burner tray to outside edge of bracket.
4"
Brackets installed 4" from outside edge of burner
66 | Regency
®
E18E Gas Fireplace Insert
tray
Log 2 pin locator match
with Log 1 pin
8. Log 2 in position, Log 2 should touch lip of burner approximately 4-1/2"
from the left outside edge of burner tray.
1
2
4-1/2"
Log 2 in position
Page 67
installation
10
E18
|
67
9. Place Log piece (4 ) on the glass crystals in the location shown below.
1
2
4
10"
Right Log piece(4) positioned on glass
. Install Log 3 by matching pin locator on Log 3 with right pin on Log
1 as shown below.
1
2
3
4
12. Position Log 5, rest on pilot hood as shown below.
1
5
2
Log 5 in position
13. Place lava embers/rocks on glass - ensure rocks do not block pilot.
Do not place lava rocks/embers too close to logs as this may cause
carboning.
14. Adjust aeration, see unit manual for setting.
15. Reverse Steps 2 and 1.
Installing Log 3
11. Installed Log 3 should touch burner position in the location shown below.
* Measurement taken from left edge of burner tray - approximately 18".
1
2
3
4
18"
Installed position of Log 3
E18 fi nal install
Regency
®
E18E Gas Fireplace Insert | 67
Page 68
68
|
installation
GLASS DOOR / SCREEN
INSTALLATION/ REMOVAL
1. Remove control cover to access door
retainer screws.
2. Remove 2 door retainer screws. (Diagram
16.1)
3. Pull door out, then lift up and out to remove. (Diagram 16.2)
4. Reverse Steps 3-1 to reinstall.
Do not operate appliance with the glass
WARNING:
front removed, cracked or broken.
Replacement of the glass should be done
by a licensed or qualified service person.
Diagram 16.1Retainer Screws
Door Frame Tab
Door Frame
Diagram 16.2
SAFETY SCREEN
REPLACEMENT
PART # 616-929
1. Remove Door as per E18E Installation sec-
tion of the manual.
2. Remove the 4 screws to remove Safety
Screen from Door.
3. Reverse order to reattach.
4. Install control cover supplied with screen.
68 | Regency
®
E18E Gas Fireplace Insert
Safety Screen
Window Frame
Fasteners, 4 places
Diagram 16.3
Page 69
installation
|
69
DRAFTHOOD CHECK
A "spillage" test must be made before the installed unit is left with the customer. Follow the
procedure below:
1. Star t all exhaust fans in the home and then close
all external doors and windows in the house.
Remove the Front Trim from the E18E to gain
better access to the Drafthood Opening. Make
sure the Glass Door is on properly.
2. Light the unit and set controls to maximum.
3. After five minutes, test that there is a “pull” on
the flue by placing a smoke match, cigarette or
similar device which gives off smoke, in front of
the spill tube. See diagram 17.1.
Check for proper draft by placing a match close
to the drafthood opening. This should be checked
after the unit has been operating for 15 min.
The smoke should be drawn into the Drafthood. If
the smoke is still not drawn into the Drafthood turn
the unit off and check for the cause of the lack of
draft. If necessary, seek expert advice.
For wind turbulent sites, a wind cap may remedy
the problem.
Note: The thermally activated safety switch will
sense the change in temperature and shut down
the gas valve in the event of a severe downdraft
or a blocked or disconnected vent. The switch
acts as a safety shut-off to prevent a build-up
of carbon monoxide. If the flue is blocked or
has no "draw", the switch will automatically
shut off the supply of gas within 5 - 10 minutes.
Tampering with the switch can result in carbon
monoxide (CO) poisoning and possible death.
If the heater turns off because of lack of draft
during the spillage test, check for the cause and
if necessary, seek expert advice.
Drafthood Opening
The thermally actuated safety switch will automatically reset after it has cooled off. The switch
will continue to cycle until the draft problem is
corrected. DO NOT BYPASS OR DISCONNECT
THIS SWITCH.
E18 Shown with front faceplate removed
Proper Draft
Diagram 17.1
Regency
Improper Draft
®
E18E Gas Fireplace Insert | 69
Page 70
70
Access Panel
On / Off Switch
Fan Speed Control
Fireplace Controls
The E18 has 3 controls for controlling flame height, fan speed and flame on/off. The fan on the E18 is designed to come on once the fireplace has reached a pre-determined temperature, and to go off once the temperature has dropper following use.
The speed of the fan can be varied by adjusting the Fan Speed Control dial up or down. These controls are located to the left side of the Surround Panels.
Providing that the pilot system is in standing mode, the main burner can be turned on or off by way of a switch located just below the Fan Speed Control dial. See the Lighting Instruction section in this manual for information on lighting the pilot.
The flame height can be adjusted from minimum to maximum by way of an adjustment knob on the Control Valve, located behind the
A)This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.
B) BEFORE OPERATINGsmell all around the appliance area for gas. Be sure to smell next
.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electric switch, do not use any phone in your building.
- Immediately call your gas supplier from a neighbours phone. Follow the gas supplier’s instructions.
-
C)
service
technician to inspect the appliance and replace any part of the control system and any gas control which has been underwater.
A) Cet appareil est muni d’un dispositif d’allumage qui allume automatiquement la veilleuse. Ne tentez pas d’allumer la veilleuse manuellement.
B) AVANT LAMISE EN MARCHE
peuvent s’accumuler au niveau du sol.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne tentez pas d’allumer l’appareil
• Ne touchez à aucun interrupteur; n'utilisez pas de téléphones se trouvant dans le bâtiment.
• Appelez immédiatement votre fournisseur de gaz depuis un téléphone extérieur. Suivez les instructions du fournisseur.
• Si vous ne pouvez pas rejoindre le fournisseur, appelez le service incendie.
C) N’utilisez pas cet appareil s’il a été plongé dans l’eau, même partiellement. Faites
contrôle ou de commande qui a été plongé dans l’eau.
DO NOT REMOVE THIS INSTRUCTION PLATE
TO TURN OFF GAS APPLIANCE
This appliance must be installed in accordance with local codes, if any;
if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or
Natural Gas and Propane Installation Codes, CSA B149.1.
WARNING:Ifyoudonotfollowtheseinstructionsexactly,afireor explosionmayresultcausingpropertydamage,personalinjuryorlossof life.Improperinstallation,adjustment,alteration,serviceormaintenance cancauseinjuryorpropertydamage.Refertotheowner’sinformation manualprovidedwiththisappliance.Forassistanceoradditional informationconsultaqualifiedinstaller,serviceagencyorgassupplier.AVERTISSEMENT.Quiconquenerespectepasscrupuleusementles instructions de la présente notice risque de déclencher un incendie ou une explosion pouvant entraîner des dégâts matériels ou des blessures pouvant
service ou d'entretien peut entraîner des blessures ou des dommages matériels.Reportez-vousaumanueld'utilisationfourniaveccetéquipement. Pour obtenir de l'aide ou des informations complémentaires, consulter un
1) Turn on ON/OFF switch
2) After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner.
3) The unit will turn on.
-onds. After this wait time, the board will start a second try for ignition by sparking for approximately 60 seconds. If there is still no positive ignition after the second attempt the board will go into lock out.The system will need to be reset as follows (after going into lock out mode):a) b) After approximately 2 seconds turn on ON/OFF switch or press ON/
OFF button if using optional remote.
c) Unit will repeat step 2.
1) Appuyer sur la touche ON / OFF de l'interrupteur.
2) Attendre 4 secondes. Le système d’allumage produira des étincelles pendant 60
3) L'appareil s’allume.
60 secondes. Si l’essai est infructueux, le système fait une pause de 35 secondes.
Il faut alors le réinitialiser en suivant les étapes ci-dessous (pour le déverrouiller) :a) Attendre 5 minutes et éteindre l’appareil en utilisant l’interrupteur ON/
OFF;
b) Attendre environ 2 secondes et rallumer le système à l’aide de l’inter-
rupteur ou de la télécommande en option.
c) L'appareil répétera l'étape 2.
1)
2) If service is to be performed - you must disconnect power to the unit.
1)
Appuyer sur la touche ON / OFF de l'interrupteur.
2) Lors de l'entretien de l'appareil, vous devez débrancher l'alimentation électri- que et couper le gaz alimentant l'appareil.
FOR YOUR SAFETY READ BEFORE LIGHTING
LIGHTING INSTRUCTIONS
919-791
|
installation
SAFETY SWITCHES
The E18E uses two safety switches to maintain proper operation.
The first is a Spill Switch which will shut off the appliance if continuous spilling of exhaust gas from the drafthood occurs. The spill switch will shut off the Main
Burner but not the Pilot. This switch resets automatically, if the problem persists the appliance will cycle on and off. If this occurs, shut the unit off and contact
a technician.
The second is a Primary Limit Switch. This switch confirms that the circulation fan is operating normally. If for any reason the circulation fan fails, the Primary
Limit Switch will turn off the Main Burner but not the Pilot before the appliance becomes too hot. This switch is automatic resetting, so if the problem persists
you will see your appliance cycling on and off. If this occurs shut the unit off and contact a technician.
OPERATION CONTROLS
FIREPLACE CONTROLS
The E18E has 3 controls for controlling flame height, fan
The speed of the fan can be varied by adjusting the Fan
Providing that the pilot system is in standing mode, the
switch located just below the Fan Speed Control dial.
See the Lighting Instruction section in this manual
for information on lighting the pilot.
The flame height can be adjusted from minimum to maxi-
The Access Panel is held in place by magnets and can
Note: Supplied white cord channel
Use cord channel to obscure cord and keep tidy. The
speed and flame on/off. The fan on the E18E is designed
to come on once the fireplace has reached a pre-determined temperature, and to go off once the temperature
has dropper following use.
Speed Control dial up or down. These controls are located
to the left side of the Surround Panels.
main burner can be turned on or off by way of a
mum by way of an adjustment knob on the Control Valve,
located behind the Access Panel.
simply be lifted away from the unit and set aside.
cord is located on the left hand side of the appliance.
1. Open channel and feed cord through.
2. Peel off backing of cord channel and adhere to hearth.
70 | Regency
®
E18E Gas Fireplace Insert
Diagram 18.1Flame control
Page 71
COPY OF THE LIGHTING PLATE INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
This appliance must be installed in accordance with local codes, if any;
if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or
WARNING: If you do not follow these instructions exactly, a fire or
explosion may result causing property d amage, personal injury or loss of
life. Improper installation, adjustment, alteration, service or maintenance
can cause injury or property damage . Refer to t he owner ’s information
manual p rovided with t his applian ce. For assistance o r additiona l
information consult a qualified installer, service agency or gas supplier.
AVERTISSEMENT. Quiconque ne respecte pas scrupuleusement les
instructions de la présente notice risque de déclencher un incendie ou une
explosion pouvant entraîner des dégâts matériels ou des blessures pouvant
service ou d'entretien peut entraîner des blessures ou des dommages
matériels. Reportez-vous au manuel d'utilisation fourni avec cet équipement.
Pour obtenir de l'aide ou des informations complémentaires, consulter un
A) This appliance is equipped with an ignition device which automatically lights the pilot.
Do not try to light the pilot by hand.
B) BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next
WHAT TO DO IF YOU SMELL GAS
C)
technician to inspect the appliance and replace any part of the control system and any
gas control which has been underwater.
A) Cet appareil est muni d’un dispositif d’allumage qui allume automatiquement la veilleuse.
Ne tentez pas d’allumer la veilleuse manuellement.
B) AVANT LA MISE EN MARCHE
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne tentez pas d’allumer l’appareil
• Ne touchez à aucun interrupteur; n'utilisez pas de téléphones se trouvant dans le
bâtiment.
• Appelez immédiatement votre fournisseur de gaz depuis un téléphone extérieur.
Suivez les instructions du fournisseur.
• Si vous ne pouvez pas rejoindre le fournisseur, appelez le service incendie.
C) N’utilisez pas cet appareil s’il a été plongé dans l’eau, même partiellement. Faites
CAUTION: Hot while in operation. Do not touch. Severe Burns may result.
Due to high surface temperatures keep children, clothing and furniture,
and control compartment clean. See installation and operating instructions
accompanying appliance.
1) Turn on ON/OFF switch
2) After approximately 4 seconds the spark ignition system will spark for 60
3) The unit will turn on.
onds. After this wait time, the board will start a second try for ignition by sparking
for approximately 60 seconds. If there is still no positive ignition after the second
attempt the board will go into lock out.
The system will need to be reset as follows (after going into lock out mode):
a)
b) After approximately 2 seconds turn on ON/OFF switch or press ON/
c) Unit will repeat step 2.
1) Appuyer sur la touche ON / OFF de l'interrupteur.
2) Attendre 4 secondes. Le système d’allumage produira des étincelles pendant 60
3) L'appareil s’allume.
60 secondes. Si l’essai est infructueux, le système fait une pause de 35 secondes.
Natural Gas and Propane Installation Codes, CSA B149.1.
.
- Do not try to light any appliance.
- Do not touch any electric switch, do not use any phone in your building.
- Immediately call your gas supplier from a neighbours phone. Follow the gas supplier’s
instructions.
-
service
peuvent s’accumuler au niveau du sol.
contrôle ou de commande qui a été plongé dans l’eau.
LIGHTING INSTRUCTIONS
seconds to light the main burner.
-
OFF button if using optional remote.
operating instructions
|
71
Il faut alors le réinitialiser en suivant les étapes ci-dessous (pour le déverrouiller) :
a) Attendre 5 minutes et éteindre l’appareil en utilisant l’interrupteur ON/
b) Attendre environ 2 secondes et rallumer le système à l’aide de l’inter-
c) L'appareil répétera l'étape 2.
OFF;
rupteur ou de la télécommande en option.
TO TURN OFF GAS APPLIANCE
1)
2) If service is to be performed - you must disconnect power to the unit.
Appuyer sur la touche ON / OFF de l'interrupteur.
1)
2) Lors de l'entretien de l'appareil, vous devez débrancher l'alimentation électri que et couper le gaz alimentant l'appareil.
DO NOT REMOVE THIS INSTRUCTION PLATE
Regency
919-791
®
E18E Gas Fireplace Insert | 71
Page 72
72
|
operating instructions
OPERATING
INSTRUCTIONS
1) Read and understand these instructions
before operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the glass in the door frame is
properly positioned. Never operate the
appliance with the glass removed.
5) Verify that the venting and cap are
unobstructed.
6) Ensure that the brick panels are installed.
7) Verify log placement. If the pilot cannot be
seen when lighting the unit, the logs have
been incorrectly positioned.
8) The unit should never be turned off, and on
again without a minimum of a 60 second
wait.
LIGHTING
PROCEDURE
IMPORTANT
To ignite or reignite the pilot, you
must first remove the glass door.
1) Press and release on ON/OFF button once
on the remote control or ON/OFF switch.
2) After approximately 4 seconds the spark
ignition system will spark for 60 seconds to
light the main burner.
3) The unit will turn on.
Note: The first try for ignition will last approxi-
mately 60 seconds. If there is no flame ignition
(rectification) the board will stop sparking for
approximately 35 seconds. After wait time
, the board will start second try for ignition
by sparking for approximately 60 seconds.
If there is still no positive ignition the board
will go into lock out.
The system will need to be reset as follows:
AERATION
ADJUSTMENT
The air shutter can be adjusted by moving the
adjusting wire up or down. The wire is accessed
through the bottom louver opening. Open the air
shutter for a blue flame or close for a yellower
flame. The burner aeration is factory set but
may need adjusting due to either the local gas
supply or altitude.
Minimum Air Shutter Opening:
3/16" Natural Gas
Fully open Propane
CAUTION: Carbon will be produced if air shutter
is closed too much.
Note: Any damage due to carboning resulting
from improperly setting the aeration
controls is NOT covered under warranty.
Note: Aeration Adjustment should only be
performed by an authorized FPI Installer
at the time of installation or service.
FIRST FIRE
The first fire in your fireplace is part of the
paint curing process. To ensure that the paint
is properly cured, it is recommended that you
burn your fireplace for at least four (4) hours the
first time you use it with the fan on.
When first operated, the unit will release an odour
caused by the curing of the paint, the burning
off of any oils remaining from manufacturing.
Smoke detectors in the house may go off at
this time. Open a few windows to ventilate the
room for a couple of hours.
The glass panel may require cleaning after the
unit has cooled down.
DO NOT ATTEMPT TO CLEAN THE
GLASS WHILE IT IS HOT.
Note: When the glass is cold and the
appliance is lit, it may cause
condensation and fog the glass.
This condensation is normal and will
disappear in a few minutes as the glass
heats up.
DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.
a) Turn the system off using ON/OFF switch
or press ON/OFF button - if using optional
remote.
b) After approximately 2 seconds turn on ON/
OFF switch or press ON/OFF button if using
optional remote.
c) Repeat step 2.
SHUTDOWN
PROCEDURE
1) Turn the wall mounted switch or remote to
the "OFF" position.
2) Press "OFF" on the remote control.
3) Turn the gas control knob to the "OFF" posi-
tion to turn off the pilot.
Adjustment wire: Push to close or
pull to open aeration cap.
Closed - Tall yellow
Open - Short Blue
During the first few fires, a white film
may develop on the glass front as part
of the curing process. The glass should
be cleaned or the film will bake on and
become very difficult to remove. Use a
non-abrasive cleaner and NEVER clean
the glass while it is hot.
72 | Regency
®
E18E Gas Fireplace Insert
Page 73
maintenance
|
73
FIRST FIRE
The first fire in your stove is part of the paint curing
process. To ensure that the paint is properly cured,
it is recommended that you burn your fireplace
for at least four (4) hours the first time you use
it with the fan on. When first operated, the unit
will release an odour caused by the curing of the
paint, the burning off of any oils remaining from
manufacturing. Smoke detectors in the house may
go off at this time. Open a few windows to ventilate
the room for a couple of hours.
The glass panel may require cleaning after the
unit has cooled down.
DO NOT ATTEMPT TO CLEAN THE
GLASS WHILE IT IS HOT.
Do not use abrasive cleaners on the
glass.
Note: When the glass is cold and the appliance
is lit, it may cause condensation and fog
the glass. This condensation is normal
and will disappear in a few minutes as
the glass heats up.
DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE.
OPERATION
The fan operates automatically, turn the knob on
the side of the faceplate to adjust to the desired
speed. The fan will turn on as the stove comes up
to operating temperature. After the unit has been
turned off and the unit cooled to below a useful heat
output range the fan will shut off automatically. This
fan is required for normal operation. If the fan stops
working at anytime the unit will automatically turn
off after a delay of approximately 15-30 minutes.
Burner Tray:
The burner tray is positioned directly under the
burner tube(s) and logs and is made of a different
gauge material from the rest of the firebox and
body. Therefore, the varying thicknesses of steel
will expand and contract at slightly different rates
which can cause "ticking" and "cracking" sounds. You
should also be aware that as there are temperature
changes within the unit these sounds will likely
re-occur. Again, this is normal for steel fireboxes.
Blower Thermodisc:
When this thermally activated switch turns ON it will
create a small "clicking" sound. This is the switch
contacts closing and is normal.
Pilot Flame:
While the pilot flame is on it can make a very slight
"whisper" sound.
Gas Control Valve:
As the gas control valve turns ON and OFF, a dull
clicking sound may be audible, this is normal operation of a gas regulator or valve.
Unit Body/Firebox:
Different types and thicknesses of steel will expand and contract at different rates resulting in
some "cracking" and "ticking" sounds will be heard
throughout the cycling process.
MAINTENANCE INSTRUCTIONS
1. Always turn the gas valve to off before cleaning.
For relighting, refer to lighting instructions. Keep
the burner and control compartment clean by
brushing and vacuuming at least once a year.
When cleaning the logs, use a clean soft paint
brush as the logs are fragile and easily damaged.
2. Clean (never when unit is hot) appliance, door
and louvers with a damp cloth. Never use an
abrasive cleaner. The gold louvers (and optional
gold door) may be scratched if abrasives are
used to clean them.
The heater is finished in a heat resistant paint
and should only be refinished with heat resistant paint (not with wall paint). Regency
StoveBrite Paint - Metallic Black #6309.
3. Make a periodic check of burner for proper position and condition. Visually check the flame of
the burner periodically, making sure the flames
are steady; not lifting or floating. If there is a
problem, call a qualified service person.
4. The appliance and venting system must be
inspected before use, and at least annually,
by a qualified field service person, to ensure
that the flow of combustion and ventilation air
is not obstructed.
During the annual service call, the burners
should be removed from the burner tray and
cleaned. Replace the embers but do not block
the pilot.
5. Keep the area near the appliance clear and
free from combustible materials, gasoline and
other flammable vapours and liquids.
6. Each time the appliance is lit, it may cause
condensation and fog the glass. This condensation and fog is normal and will disappear in
a few minutes as the glass heats up.
®
uses
NORMAL OPERATING SOUNDS
OF GAS APPLIANCES
It is possible that you will hear some sounds from
your gas appliance. This is perfectly normal due to
the fact that there are various gauges and types
of steel used within your appliance. Listed below
are some examples. All are normal operating sounds and should not be considered as defects
in your appliance.
Blower:
Regency® gas appliances use high tech blowers
to push heated air farther into the room. It is not
unusual for the fan to make a "whirring" sound
when ON. This sound will increase or decrease
in volume depending on the speed setting of your
fan speed control.
Regency
Never operate the appliance without
the glass properly secured in place or
with the door open.
7. Verify proper operation after servicing.
8. Periodically check the pilot flames, see the
diagrams in the "Valve Description" section.
If you have an incorrect flame pattern, contact
your Regency
WARNING: CHILDREN AND
ADULTS SHOULD BE ALERTED TO
THE HAZARDS OF HIGH SURFACE
TEMPERATURE AND SHOULD STAY
AWAY TO AVOID BURNS OR CLOTHING
IGNITION. YOUNG CHILDREN SHOULD
BE CAREFULLY SUPERVISED WHEN
THEY ARE IN THE SAME ROOM AS
THE APPLIANCE.
®
dealer for further instructions.
®
E18E Gas Fireplace Insert | 73
Page 74
74
|
maintenance
CAUTION: ANY SAFETY SCREEN OR
GUARD REMOVED FOR SERVICING AN
APPLIANCE MUST BE REPLACED PRIOR
TO OPERATING THE APPLIANCE.
CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NOT BE PLACED
ON OR NEAR THE APPLIANCE.
LOG REPLACEMENT
The unit should never be used with broken logs. Turn
off the gas valve and allow the unit to cool before
opening door to carefully remove the logs. The pilot
light generates enough heat to burn someone. If
for any reason a log should need replacement, you
must use the proper replacement log. The position
of these logs must be as shown in the diagram
under Log Installation.
NOTE: Improper positioning of logs may create
carbon build-up and will alter the unit’s
performance which is not covered under
warranty.
GLASS GASKET
If the glass gasket requires replacement use Part
# 936-155 to order new gasket.
DOOR GLASS
Your Regency® fireplace is supplied with high
temperature 5mm-Ceramic glass. If your glass
requires cleaning, we recommend using an
approved glass cleaner available at all authorized
dealers. Do not use abrasive materials.
CAUTION & WARNINGS:
* Do not clean when the glass is hot.
* The use of substitute glass will void all
product warranties.
* Care must be taken to avoid breakage of
the glass.
* Do not strike or abuse the glass.
* Do not operate this fireplace without the
glass front or with a cracked or broken
glass front.
* Wear gloves when removing damaged or
broken glass.
* Replacement of the glass panels should be
done by a licensed or qualified service per
son.
GLASS REPLACEMENT
In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency dealer only. Replacement glass (Part
#616-518/P) is shipped already installed into the
door frame. Reinstall as per Glass Door Installation
in the "Glass Door Removal" section.
74 | Regency
®
E18E Gas Fireplace Insert
Page 75
maintenance
|
75
VALVE REPLACEMENT
1. Shut off the gas and electrical supply.
2. Remove Faceplate Control Cover (see instructions in manual).
3. Remove Glass Door (see instructions in manual).
4. Remove Log Set and Embers or crystals and stones (if installed).
5. Remove Burner and Panels (see instructions in this manual).
6. Unplug the Orange, Green, and Ground wires on the front of the Valve.
Green
Orange
Ground
Diagram 19.1
INSTALLING VALVE
1. Place new valve tray and gasket into position.
2. Reverse Steps 9-1.
3. Check for gas leaks.
7. Unscrew the 8 screws holding down the Valve Tray.
Diagram 19.2
8. Slide the Valve Tray out about half way giving easier access to the gas
connection at the valve.
Diagram 19.3
9. Disconnect the gas line and remove the valve tray.
Regency
®
E18E Gas Fireplace Insert | 75
Page 76
76
|
maintenance
REMOVING THE FAN
IMPORTANT
Disconnect power supply
before servicing.
1. Shut off the gas and electrical supply.
2. Remove Control Cover. (see instructions in manual)
3. Remove Glass Door.(see instructions in manual)
4. Remove Log Set and Embers or crystals and stones (if installed).
5. Remove Burner and Panels (see instructions in manual)
6. Remove Valve Tray - see previous page.
7. Disconnect Ground Wires and unclip Safety Circuit Wires and remove
through Grommet .
Diagram 20.1
8. Loosen 4 screws holding in Air Inlet Baffle and remove it.
9. Loosen 3 screws holding in the Circulation Fan.
10. Disconnect Power Leads on Fan Motor
Diagram 20.2
11. Reverse Steps to reinstall.
76 | Regency
®
E18E Gas Fireplace Insert
Page 77
WIRING DIAGRAMS
maintenance
|
77
This heater requires a 120V A.C. supply for
operation of the circulation fan which is required
for operation of the fireplace. In case of a power
failure, the fireplace can be turned on but a
thermal safety switch will cut out the appliance
before it gets too hot. The unit will cycle on
and off as required to stay within temperature
specifications.
Caution: Ensure that the wires do
not touch any hot surfaces and are
away from sharp edges.
When connected with 120 volts, the appliance
must be electrically grounded in accordance
with local codes or, in the absence of local
codes the current CSA C22.1 (in Canada) or
with the National Electrical Code ANSI/NFPA
70-1987 (in USA).
NOTE: This unit is equipped with a heat
sensor thermodisc which will
prevent the blower from operating
until the unit reaches the correct
temperature.
CAUTION: Label all wires prior
to disconnection when servicing
controls. Wiring errors can
cause improper and dangerous
operation.
Diagram 21.1
WARNING: Electrical Grounding Instructions
This appliance is equipped with a three pronged
(grounding) plug for your protection against shock
hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut
or remove the grounding prong from this plug.
Regency
®
E18E Gas Fireplace Insert | 77
Page 78
78
|
maintenance
WIRING DIAGRAMS
(Do not cut the ground terminal off under any circumstances.)
Fan must always operate with this unit.
1. Remove wire labelled 911-240 in diagram above for GTM Remote and thermostat installation.
2. Remote and thermostat must be wired in series.
Diagram 21.2
78 | Regency
®
E18E Gas Fireplace Insert
Page 79
MAIN ASSEMBLY
parts list
|
79
1617-574/PValve Assembly - NG
1617-576/PValve Assembly - LP
3911-004Valve Only - NG 886 SIT IPI High/Low 0.886.002
3911-005Valve Only - LP 886 SIT IPI High/Low 0.886.003
5911-006Pilot Assembly IPI NG 2 Flame 0.199.050
5911-007Pilot Assembly IPI LP 2 Flame
6910-100Pilot Orifice NG #62 977.166
6910-101Pilot Orifice LP #35 977.168
9904-943Bracket Dormont Orifice Mount 10-BZ001-19.5
10904-974Burner Orifice #44 NG (PO512)
10904-977Burner Orifice #55 LP (PO512)
11911-038Spark Electrode Cable Black End 0.915.020
12911-037Sense Electrode & Cable Red End 0.915.905
13911-039Pilot Hood 2 Flame Sit SureFire0.975.005
14911-008Novasit Regulator NG For 886 SIT 907.014
14911-009Novasit Regulator LP For 886 SIT 907.014
15911-012Ignition Board (DFC) SIT IPI 0.584.302
17911-118High Limit Switch 36T21 22583
18911-119Spill Switch 60T11 610021
19W241050Fan Thermodisc 60T12-610049
20616-517/PFan Assembly Complete
21910-331/PBlower Motor only - Includes Squirrel Cage
22616-518/PFlush Door Glass Assembly Complete
23616-529Safety Screen
24617-006Spill Switch Bracket
25616-515Log Tray Assembly
N/S904-978Inlet Flex Line Gas SS Steel 18" Black
N/S904-165Fitting 3/8 Male Flarex Mpt Strt Adaptor
N/S904-599Fitting Elbow 90 Degree
N/S911-138Thermostat Digital Non-Programmable
N/S910-246Switch 2 Way Gold Contact
N/S616-525Burner Assembly NG/LP
N/S910-432Pilot Tube 1/8 x 24 w/ Steel Fittings
N/S904-529Allen Key 5/32 Long
N/S911-013Wire Harness Inc. Grn IP/CP Swth 584.912
N/S910-610Black Wire FanTerminal Block To Switch
N/S910-749White Wire Fan
N/S910-805White Wire Thermodisc To Swtich
N/S911-116Speed Control Fan w/ Connectors E18
N/S911-170Blue Wire To Spill Switch to High Limit
N/S911-172Yellow Wire Thermodisc To Switch
N/S911-245Extension Cord
N/S911-238Red Wire Switch To Harness
N/S911-239Brown Wire Coupling to High Limit
N/S911-240Brown Wire Coupling
N/S910-592Hand Held Remote Control GTMF SIT 0.584.023
FPI Fireplace Products International Ltd. (for Canadian customers) and Fireplace Products U.S., Inc. (for U.S.
customers) (collectively referred to herein as “FPI”) extends this Limited Lifetime Warranty to the original
purchaser of this appliance provided the product remains in the original place of installation. The items covered by
this limited warranty and the period of such coverage is set forth in the table below.
Some conditions apply (see below).
The policy is not transferable, amendable or negotiable under any circumstances.
Part
Lifetime 5 years 2 years 1 year Warranty (Years)
3
|
89
components, (Pilot assembly,
flame sensors, Spark Electrode,
Pilot Tubing, Orifices,
components,(Ignition Control
Boards, Wiring, Switches, Blowers,
Blower Control Module, Battery
Firebeads, Volcanic,
Conditions:
Warranty protects against defect in manufacture or FPI factory assembled components only, unless herein
specified otherwise.
Any part(s) found to be defective during the warranty period as outlined above will be repaired or replaced at FPI’s
option through an accredited distributor, dealer or pre-approved and assigned agent provided that the defective
part is returned to the distributor, dealer or agent for inspection if requested by FPI. Alternatively, FPI may at its
own discretion fully discharge all of its obligations under the warranty by refunding the verified purchase price of
the product to the original purchaser. The purchase price must be confirmed by the original Bill of Sale.
The authorized selling dealer, or an alternative authorized FPI dealer if pre-approved by FPI, is responsible for all
in-field diagnosis and service work related to all warranty claims. FPI is not responsible for results or costs of
workmanship of unauthorized FPI dealers or agents in the negligence of their service work.
Regency
2
2
1
®
E18E Gas Fireplace Insert | 89
Page 90
90
|
warranty
At all times FPI reserves the right to inspect reported complaints on location in the field claimed to be defective
prior to processing or authorizing of any claim. Failure to allow this upon request will void the warranty.
All warranty claims must be submitted by the dealer servicing the claim, including a copy of the Bill of Sale (proof
of purchase by you). All claims must be complete and provide full details as requested by FPI to receive
consideration for evaluation. Incomplete claims may be rejected.
Unit must be installed according to all manufacturers’ instructions as per the manual.
All Local and National required codes must be met.
The installer is responsible to ensure the unit is operating as designed at the time of installation.
The original purchaser is responsible for annual maintenance of the unit, as outlined in the owner’s manual. As
outlined below, the warranty may be voided due to problems caused by lack of maintenance.
Repair/replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit
will carry a 90 day warranty, valid with a receipt only. Any item shown to be defective will be repaired or replaced
at our discretion. No labor coverage is included with these parts
Exclusions:
This Limited Lifetime Warranty does not extend to paint, rust or corrosion of any kind due to a lack of maintenance
or improper venting, combustion air provision, corrosive chemicals (i.e. chlorine, salt, air, etc.), door or glass
gasketing.
Malfunction, damage or performance based issues as a result of environmental conditions, location, chemical
damages, downdrafts, installation error, installation by an unqualified installer, incorrect chimney components
(including but not limited to cap size or type), operator error, abuse, misuse, use of improper fuels , lack of regular
maintenance and upkeep, acts of God, weather related problems from hurricanes, tornados, earthquakes, floods,
lightning strikes/bolts or acts of terrorism or war, which result in malfunction of the appliance are not covered
under the terms of this Limited Lifetime Warranty.
FPI has no obligation to enhance or modify any unit once manufactured (i.e. as products evolve, field modifications
or upgrades will not be performed on existing appliances).
This warranty does not cover dealer travel costs for diagnostic or service work. All labor rates paid to authorized
dealers are subsidized, pre-determined rates. Dealers may charge homeowner for travel and additional time
beyond their subsidy.
Any unit showing signs of neglect or misuse will not be covered under the terms of this warranty policy and may
void this warranty. This includes units with rusted or corroded fireboxes which have not been reported as rusted or
corroded within three (3) months of installation/purchase.
Units which show evidence of being operated while damaged, or with problems known to the purchaser and
causing further damages will void this warranty.
Units where the serial no. has been altered, deleted, removed or made illegible will void this warranty.
Minor movement, expansion and contraction of the steel is normal and is not covered under the terms of this
warranty.
Freight damages for products or parts are not covered under the terms of the warranty.
Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior
authorization from FPI may void this warranty.
90 | Regency
®
E18E Gas Fireplace Insert
Page 91
warranty
Canadian Warrantor:
Canada, V4G 1H4
U.S. Warrantor:
United States, 98231
Limitations of Liability:
The original purchaser’s exclusive remedy under this warranty, and FPI’s sole obligation under this warranty,
express or implied, in contract or in tort, shall be limited to replacement, repair, or refund, as outlined above. IN
NO EVENT WILL FPI BE LIABLE UNDER THIS WARRANTY FOR ANY INCIDENTAL OR CONSEQUENTIAL COMMERCIAL
DAMAGES OR DAMAGES TO PROPERTY. TO THE EXTENT PERMITTED BY APPLICABLE LAW, FPI MAKES NO EXPRESS
WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS
LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. IF IMPLIED WARRANTIES CANNOT BE
DISCLAIMED, THEN SUCH WARRANTIES ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY.
Some U.S. states do not allow limitations on how long an implied warranty lasts, or allow exclusion or limitation of
incidental or consequential damages, so the above limitations or exclusions may not apply to you.
Customers located outside the U.S. should consult their local, provincial or national legal codes for additional
terms which may be applicable to this warranty.
How to Obtain Warranty Service:
Customers should contact the authorized selling dealer to obtain warranty service. In the event the authorized
selling dealer is unable to provide warranty service, please contact FPI by mail at the address listed below. Please
include a brief description of the problem and your address, email and telephone contact information. A
representative will contact you to make arrangements for an inspection and/or warranty service.
|
91
FPI Fireplace Products International Ltd.
6988 Venture St.
Delta, British Columbia
Fireplace Products U.S., Inc.
PO Box 2189 PMB 125
Blaine, WA
Or contact the Regency Customer Care Centre at 1-800-442-7432 (phone) / 604-946-4349 (fax)
Product Registration and Customer Support:
Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and
marketing of hearth products. To provide the best support for your product, we request that you complete a
product registration form at http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspxwithin
ninety (90) days of purchase.
Regency
®
E18E Gas Fireplace Insert | 91
Page 92
92
Warranty Details
Serial Number (required):
Purchase Date (required) (mm/dd/yyyy):
Product Details
Product Model (required):
Dealer Details
Dealer Name (required):
Dealer Address:
Dealer Phone #:
Installer:
Date Installed (mm/dd/yyyy):
Your Contact Details (required)
Name:
Address:
Phone:
Email:
For purchases made in CANADA:
Canada, V4G 1H4
For purchases made in the UNITED STATES:
Fax: 604-946-4349
Fax: 604-946-4349
|
warranty
Product Registration and Customer Support:
Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and
marketing of hearth products. To provide the best support for your product, we request that you complete a product
registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
For purchases made in CANADA or the UNITED STATES:
You may also complete the warranty registration form below to register your Regency Fireplace Product and mail and/or
fax it back to us, and we will register the warranty for you. It is important you provide us with all the information below in
order for us to serve you better.
Warranty Registration Form (or Register online immediately at the above Web Site):
FPI Fireplace Products
International Ltd.
6988 Venture St.
Delta, British Columbia
Phone: 604-946-5155
For fireplace care and tips and answers to most common questions please visit our Customer Care section on our Web Site.
Please feel free to contact your selling dealer if you have any questions about your Regency product.
92 | Regency
®
E18E Gas Fireplace Insert
Fireplace Products U.S., Inc.
PO Box 2189 PMB 125
Blaine, WA
United States, 98231
Phone: 604-946-5155
For purchases made in AUSTRALIA:
Fireplace Products Australia Pty
Ltd
1- 3 Conquest Way
Hallam, VIC
Australia, 3803
Phone: +61 3 9799 7277
Fax: +61 3 9799 7822
Page 93
warranty
|
93
Regency
®
E18E Gas Fireplace Insert | 93
Page 94
94
|
notes
94 | Regency
®
E18E Gas Fireplace Insert
Page 95
|
95
Regency
®
E18E Gas Fireplace Insert | 95
Page 96
Installer: Please complete the following information
Dealer Name & Address: ______________________________________________