WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach you gas supplier, call the re department.
Installation and service must be performed by a qualied installer, service agency or the gas supplier.
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
919-377
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
09.30.14
2
|
To the New Owner:
Congratulations!
You are the owner of a state-of-the-art Gas Fireplace by REGENCY
B41XTE has been designed to provide you with all the warmth and charm of a wood replace
at the ick of a switch. The Bellavista™ B41XTE has been approved by Warnock Hersey/
Intertek for both safety and efciency. As it also bears our own mark, it promises to provide
you with economy, comfort and security for many trouble free years to follow. Please take
a moment now to acquaint yourself with these instructions and the many features of your
Regency
®
Fireplace.
®
. The Bellavista™
2 | Regency Bellavista™ B41XTE -10 Gas Fireplace
|
MANUFACTURED MOBILE HOME REQUIREMENTS
INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE
This Regency® product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to the following standards:
VENTED GAS FIREPLACE HEATERS ANSI Z21.88-2014 / CSA 2.33-2014 and GAS-FIRED APPLIANCES FOR USE AT HIGH
ALTITUDES CAN / CGA 2.17-M91.
This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured
Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada.
This appliance installation must comply with the manufacturer's installation instructions and local codes, if any. In the absence of local
codes follow the current National Fuel Gas Code, ANSI Z223.1 and the current National Electrical Code ANSI/NFPA 70 in the U.S.A.,
and the current CAN/CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22.1 in Canada.
This appliance comes equipped with a dedicated #8 Ground Lug for attachment of the ground wire to the steel chassis as applicable
to local codes.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
This appliance may only be installed in an aftermarket permanently located, manufactured (U.S.A only) or mobile home, where not
prohibited by local codes.
3
This appliance can only be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other
gases.
Ensure that structural members are not cut or weakened during installation.
Regency Bellavista™ B41XTE -10 Gas Fireplace | 3
4
|
table of contents
MA Code - CO Detector.................................................6
Unit Dimensions ............................................................7
Important Message ......................................................8
Before You Start ............................................................8
General Safety Information............................................8
The Warranty: Limited Lifetime ...................................63
4 | Regency Bellavista™ B41XTE -10 Gas Fireplace
|
This is a copy of the label that accompanies each
Bellavista™ B41XTE Direct Vent Gas Fireplace.
We have printed a copy of the contents here
for your review.
®
NOTE: Regency
improved. Check the label on the unit and if
there is a difference, the label on the unit is
the correct one.
units are constantly being
safety decal
5
For the State of Massachusetts, installation
and repair must be done by a plumber or
gas tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, exible
connectors shall not exceed 36 inches in
length.
For the State of Massachusetts, the appliances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
Regency Bellavista™ B41XTE -10 Gas Fireplace | 5
6
the installation.
|
requirements
MA Code - CO Detector
(for the State of Massachusetts only)
5.08: Modifications to NFPA-54, Chapter 10
(2) Revise 10.8.3 by adding the following additional requirements:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for
residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than
seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall
be satisfied:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled
equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is
installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery
operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure
served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of
qualified licensed professionals for the installation of hard wired carbon monoxide detectors
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon
monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of
thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon
monoxide detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions
shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.
3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight
(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The
sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL
OBSTRUCTIONS".
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation
unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR
5.08(2)(a)1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by
the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or
structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product
Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the
instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a
Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies
"special venting systems", the following requirements shall be satisfied by the manufacturer:
1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and
2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and
detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions,
all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of
6 | Regency Bellavista™ B41XTE -10 Gas Fireplace
|
UNIT DIMENSIONS
568mm
22 3/8"
19 1/2"-
495mm
46 9/16"1183mm
41 11/16"-
1059mm
38 3/8"974mm
43 7/16"1103mm
35"
[mm]889
WINDOW
13 3/16"-
335mm
2 7/16"-
61mm
1 15/16"-
49mm
dimensions
7
958mm
886mm
34 7/8"-
37 11/16"-
SCREEN FRAME
39 7/8"-
1012mm
SCREEN FRAME
27mm
1 1/16"-
Regency Bellavista™ B41XTE -10 Gas Fireplace | 7
24"
610mm
WINDOW
36 3/8"-
924mm
8
|
installation
IMPORTANT MESSAGE
SAVE THESE
INSTRUCTIONS
The B41XTE Gas Fireplace must be installed in
accordance with these instructions. Carefully read
all the instructions in this manual rst. Consult the
"authority having jurisdiction" to determine the need
for a permit prior to starting the installation. It is the
responsibility of the installer to ensure this replace
is installed in compliance with manufacturers
instructions and all applicable codes.
BEFORE YOU START
Safe installation and operation of this appliance
requires common sense, however, we are required
by the Canadian Safety Standards and ANSI
Standards to make you aware of the following:
INSTALLATION AND REPAIR SHOULD
BE DONE BY AN AUTHORIZED
SERVICE PERSON. THE APPLIANCE
SHOULD BE INSPECTED BEFORE
USE AND AT LEAST ANNUALLY BY A
PROFESSIONAL SERVICE PERSON.
MORE FREQUENT CLEANING MAY
BE REQUIRED DUE TO EXCESSIVE
LINT FROM CARPETING, BEDDING
MATERIAL, ETC. IT IS IMPERATIVE THAT
CONTROL COMPARTMENTS, BURNERS
AND CIRCULATING AIR PASSAGEWAYS
OF THE APPLIANCE BE KEPT CLEAN.
YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE
IN THE SAME AREA AS THE APPLIANCE. TODDLERS, YOUNG CHILDREN
AND OTHERS MAY BE SUSCEPTIBLE
TO ACCIDENTAL CONTACT BURNS. A
PHYSICAL BARRIERS IS RECOMMENDED IF THERE ARE AT RISK INDIVIDUAL
IN THE HOUSE. TO RESTRICT ACCESS
TO A FIREPLACE OR STOVE, INSTALL
AN ADJUSTABLE SAFETY GATE TO
KEEP TODDLERS, YOUNG CHILDREN
AND OTHER AT RISK INDIVIDUALS OUT
OF THE ROOM AND AWAY FROM HOT
SURFACES.
CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NOT BE PLACED
ON OR NEAR THE APPLIANCE.
A BARRIER DESIGNED TO REDUCE
THE RISK OF BURNS FROM THE HOT
VIEWING GLASS IS PROVIDED WITH
THIS APPLIANCE AND SHALL BE
INSTALLED FOR THE PROTECTION
OF CHILDREN AND OTHER AT-RISK
INDIVIDUALS
IF THE BARRIER BECOMES DAMAGED,
THE BARRIER SHALL BE REPLACED
WITH THE MANUFACTURER'S BARRIER
FOR THIS APPLIANCE.
4) This appliance must be connected to the
specied vent and termination cap to the outside
of the building envelope. Never vent to another
room or inside a building. Make sure that the
vent is tted as per Venting instructions.
5) Inspect the venting system annually for blockage
and any signs of deterioration.
6) Venting terminals shall not be recessed into a
wall or siding.
7) Any safety glass removed for servicing must be
replaced prior to operating the appliance.
8) To prevent injury, do not allow anyone who is
unfamiliar with the operation to use the replace.
9) Wear gloves and safety glasses for protection
while doing required maintenance.
10) Be aware of electrical wiring locations in walls
and ceilings when cutting holes for termination.
11) Under no circumstances should this appliance
be modied. Parts that have to be removed for
servicing should be replaced prior to operating
this appliance.
12) Installation and any repairs to this appliance
should be done by a qualied service person.
A professional service person should be called
to inspect this appliance annually. Make it a
practice to have all of your gas appliances
checked annually.
13) Do not slam shut or strike the glass door.
14) Under no circumstances should any solid fuels
(wood, paper, cardboard, coal, etc.) be used in
this appliance.
DUE TO HIGH TEMPERATURES, THE
APPLIANCE SHOULD BE LOCATED
OUT OF TRAFFIC AND AWAY FROM
FURNITURE AND DRAPERIES.
ANY SAFETY SCREEN, GUARD, OR
BARRIER REMOVED FOR SERVICING
AN APPLIANCE MUST BE REPLACED
PRIOR TO OPERATING THE APPLIANCE.
WARNING: FAILURE TO INSTALL THIS
APPLIANCE CORRECTLY WILL VOID
YOUR WARRANTY AND MAY CAUSE A
SERIOUS HOUSE FIRE.
GENERAL SAFETY
INFORMATION
1) The appliance installation must conform
CHILDREN AND ADULTS SHOULD BE
ALERTED TO THE HAZARDS OF HIGH
SURFACE TEMPERATURES, ESPECIALLY THE FIREPLACE GLASS, AND
SHOULD STAY AWAY TO AVOID BURNS
OR CLOTHING IGNITION.
2) The appliance when installed, must be
3) See general construction and assembly
8 | Regency Bellavista™ B41XTE -10 Gas Fireplace
15) The appliance area must be kept clear and
free of combustible materials, (gases and other
ammable vapours and liquids).
Emissions from burning wood or gas could
contain chemicals known to the State of
California to cause cancer, birth defects or
other reproductive harm.
with local codes or, in the absence of local
codes, with the current Canadian or National
Gas Codes, CAN1-B149 or ANSI Z223.1
Installation Codes.
electrically grounded in accordance with local
codes, or in the absence of local codes with
the current National Electrical Code, ANSI/
NFPA 70 or CSA C22.1 Canadian Electrical
Code.
instructions. The appliance and vent should
be enclosed.
|
installation
9
INSTALLATION
CHECKLIST
1) Locate appliance
a) Room location (Refer to "Locating Your
Gas replace" section)
b) Clearances to Combustibles (Refer to
"Clearances" section)
c) Mantle Clearances (Refer to "Combustible
Mantel Clearances" section)
d) Framing & Finishing Requirements (Refer
to "Framing & Finishing" section)
e) Venting Requirements (Refer to "Venting"
section)
2) Assemble Top Standoffs and Top Facing
Support and Side Nailing Strips (Refer to
"Unit Assembly Prior to Installation" Section).
Note: Must be done before installing unit into
place.
3) Install vent (Refer to "Venting" sections).
4) Make gas connections. Test the pilot. Must be
as per diagram (Refer to "Pilot Adjustment"
section).
5) Make electrical connections to receptacle
supplied with unit (recommended).
6) Install standard and optional features. Refer
to the following sections:
a. Install 4AA batteries into remote receiver
/ hookup AC power adaptor
b. Inner Panels or Brick Panels (Required)
c. Log Set Installation
d. Standard Flush Door
e. Fan Installation (Optional)
f. Light Installation (Optional)
g. Finishing Trim (Optional)
This includes:
1) Clocking the appliance to ensure the correct
ring rate (rate noted on label), after burning
appliance for 15 minutes.
2) If required, adjusting the primary air to ensure
that the ame does not carbon. First allow
the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.
LOCATING YOUR
GAS FIREPLACE
1) When selecting a location for your replace,
ensure that the clearances are met.
2) The appliance must be installed on a at,
solid, continuous surface For example a
wood, metal or concrete oor or in a raised (on
the wall) application. The appliance must be
installed on a metal or wood panel extending
the full width and depth of the appliance.
3) The B41XTE Gas Fireplace can be installed
in a recessed position or framed out into the
room as in A, B, C and D. See Diagram 1.
A) Flat on Wall
4) This appliance is Listed for bedroom
installations using the standard Remote
(millivolt thermostat system). Some areas
may have further requirements, check local
codes before installation.
5) The B41XTE Gas Fireplace are approved
for alcove installations, see "Clearances"
section for details.
6) We recommend that you plan your installation
on paper using exact measurements for
clearances and floor protection before
actually installing this appliance. Have an
authorized inspector, dealer, or installer
review your plans before installation.
Note: For vent terminations refer to
"Exterior Vent Termination Locations"
section.
7) Final check.
Diagram 1
B) Flat on Wall Corner
C) Recessed into Wall/Alcove
D) Corner
Regency Bellavista™ B41XTE -10 Gas Fireplace | 9
10
A
|
CLEARANCES
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest
importance that this replace and vent system be installed only in accordance with these instructions.
installation
The top, back and sides of the replace are dened by
Caution Requirements
standoffs. The metal ends of the standoff may NOT
be recessed into combustible construction.
B41XTE Clearance Requirements
Clearance:DimensionMeasured From:
A: Mantel Height (min.)15" (381mm)Top of Fireplace Opening
B: Sidewall9" (229mm)Side of Fireplace Opening
C: Ceiling33-3/4" (933mm)Top of Fireplace Opening
D: Mantel Depth (max.)12" (304mm)23-1/4" (591mm)
E: Alcove Width60" (1524mm)Wall to Wall (Minimum)
F: Alcove Depth36" (914mm)Front to Back Wall (Maximum)
Notes:0"No Hearth Required
NOTE: A 16" deep non-combustible hearth pad is
recommended for hardwood ooring and carpet.
Fire hazard is an extreme risk
WARNING
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this replace and vent
system be installed only in accordance with these instructions.
from Top of Fireplace Opening
D
C
10 | Regency Bellavista™ B41XTE -10 Gas Fireplace
E
F
Alcove
F
B
Minimum Vent Clearances
to Combustibles
Horizontal Top3" (76mm)
Horizontal Side2 " (51mm)
Horizontal Bottom2" (51mm)
E
Vertical Vent2" (51mm)
|
installation
MANTEL CLEARANCES
Due to the extreme heat this replace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are
shown in the diagram on the right.
Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible
board.
Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour.
11
Mantel Clearances
B41XT
From Top of
Fireplace Opening
Regency Bellavista™ B41XTE -10 Gas Fireplace | 11
ABCD
35-1/4"
(895mm)
23-1/4"
(591mm)
19-1/2"
(495mm)
15"
(381mm)
12
|
MANTEL LEG CLEARANCES
installation
9” Side Wall
(Measured from side of
Fireplace Opening)
Mantel leg
1-1/2"
4”
7”
Allowable mantel leg
projection.
Mantel leg
3"
NON-COMBUSTIBLE REQUIREMENTS
Non-combustible
Non-combustible
Non-combustible
(1276mm)
Non-combustible
50-1/4"
41-3/4"
(1060mm)
48-3/4"
(1238mm)
Material
36-3/4"
(933mm)
Non-combustible
Header
(steel stud)
on edge
(343mm)
Min. 13-1/2"
Non-combustible
Min. 3-1/2”
(89mm)
12 | Regency Bellavista™ B41XTE -10 Gas Fireplace
47-1/4" (1200mm)
Framing
Min. 3-1/2”
(89mm)
|
installation
FRAMING
Framing DimensionsDescriptionB41XTE
MFraming Width47-1/4"(1200mm)
NFraming Height49-1/2" (1257mm)
O (Rear Vent)Framing Depth - Rear Vent23-1/4" (591mm)
O (Top Vent)Framing Depth - Top Vent22-5/8" (575mm)
P Corner Facing Wall Width60-1/4" (1530mm)
Q Corner Facing Wall Width85-3/16" (2163mm)
R (Rear Vent)Framed Chase Ceiling - Rear49-1/2" (1257mm)
R (Top Vent)Framed Chase Ceiling - Top54-1/2" (1384mm)
S (Rear Vent)Vent Centerline Height - Rear28-1/2" (724mm)
** Important: Framing height requires consideration of the hearth depth. Dimension N = N + the thickness of the installed hearth.
13
Non-Combustible
Header
(steel stud)
on edge
N
M
R
Drywall, Wood
(orother facing)
Non-Combustible
Header
(steel stud) on edge
W
Non-Combustible Facing
11" (279mm)
dia. Hole through
wall Vent.
O
S
S
P
Rear Vent
TopVent
Regency Bellavista™ B41XTE -10 Gas Fireplace | 13
Q
T
U
Opening for gas
connection
V
14
|
installation
WALL MOUNT ON / OFF SWITCH AND REMOTE RECEIVER INSTALLATION
REQUIRED FOR ALL INSTALLATIONS - INCLUDING PROFLAME REMOTE CONTROLS
IMPORTANT INSTALLATION NOTE:
The Receiver must be placed inside the supplied (Low Voltage)
junction type wall box and installed into the wall only.
DO NOT INSTALL WITHIN THE CONFINES OF THE FIREPLACE.
Remote Receiver Installation
1. Install the low voltage junction box to the framing, at desired location within 10 ft. from fi replace.
2. Feed the 12 pin connector through the opening at back of junction box.
3. Connect the 12 pin connector to the back of the receiver.
4. Install the Receiver in the Low Voltage Junction box.
5. Insert the 4 AA type batteries in the battery compartment with the correct polarity.
6. Place the slider into the cover plate.
7. Put the Receiver switch in the “OFF” position, to allow correct lineup for slider switch.
8. Make sure the Receiver and cover plate words “ON” and “UP” are on the same side.
9. Align the slider with the switch on the Receiver and couple the switch into the slider.
10. Align the screw holes.
11. Using the two (2) screws provided secure the cover plate to the Receiver.
Profl ame Receiver
Slider Switch
Low Voltage Junction Box
J-Box
Receiver
Wall Plate
14 | Regency Bellavista™ B41XTE -10 Gas Fireplace
10 ft. wire harness with
12 pin connector
Diagram 1
|
Non-combustible
Material
J-style Trim
or metal corner bead
maybe used to finish these
edges
Non-combustible
Material
Non-combustible
Material
FINISHING
IMPORTANT FINISHING DETAIL NOTE:
Before placing unit into nal position - it is important to know the total
thickness / height of nished hearth (tile, carpet, etc.) The base of the
replace should be level or higher than the nished hearth height.
Diagram 1
Note:
All non-combustible facing material should butt up cleanly to the anges
around the rebox opening.
Rough edges will be visible from the front view with the ush louvers or
ush panels - if not using the optional nishing trim.
To maintain a clean nished edge - it is recommended to install the noncombustible facing material with the nished edge against the replace
/ nailing strips.
installation
15
Alternatively, you can use J Style Trim or Metal Corner Bead to cover
cut edges of the non-combustible facing material.
Diagram 2
3
"
43
8
"
5
8
37
Diagram 3: Shown with optional Finishing Trim
Regency Bellavista™ B41XTE -10 Gas Fireplace | 15
16
Nail4.eps
Nail5.eps
A
A
B
C
B
C
TopFacingSupport
isreversed
for“C”holeposition
A
A
B
C
B
C
Support
Screwholes
forSide
NailingStrip
Top Facing Support
A
B
C
Screw holes for
Top Facing
Support
TopFacingSupport
A
A
B
C
B
C
Screwholesfor
TopFacing
Support
Screwholes
forSide
NailingStrip
Top Facing Support
is reversed
for “C” hole position
A
B
C
TopFacingSupport
Nail4.eps
Nail5.eps
A
A
B
C
B
C
TopFacingSupport
isreversed
for“C”holeposition
A
A
B
C
B
C
Screwholesfor
TopFacing
Support
Screwholes
forSide
NailingStrip
TopFacingSupport
isreversed
for“C”holeposition
A
B
C
Top Facing
Support
|
installation
UNIT ASSEMBLY PRIOR TO INSTALLATION
BEFORE YOU START
The Top Facing Support, the Side Nailing Strips, the 2 Top Standoffs and the Flue Collar must be correctly positioned and attached before the replace
is moved into position.
TOP STANDOFF ASSEMBLY
The top standoffs are shipped in a at position and must be folded into shape and attached.
1) Remove the standoffs from the replace top.
2) Take each standoff and bend into the correct shape. Bend up at the bend lines until
the screw holes in the standoff and the pre-punched screw holes on the replace
top line up.
3) Attach the standoff securely to the top with 2 screws per standoff (on opposite
corners).
TOP FACING SUPPORT
Determine the total thickness of facing material (e.g. drywall or wood plus ceramic tiles) to
allow the nished surface to be ush with the front of the unit. Total facing thickness can vary
from 1/2" (13mm) to 1-1/4" (32mm) thick.
The Top Facing Support can be mounted in
3 different positions depending on the
thickness of the facing material.
1) Mount Top Facing Support using the 3 supplied screws into the three pre-punched screw
holes on the top front of the unit. Use hole positions A, B, or C depending on your facing depth.
Screw Facing Material
Position Depth
A 1/2" / 13mm
B 7/8" / 22mm
C* 1-1/4" / 32mm
* For "C" screw position the top facing
support is reversed.
SIDE NAILING STRIPS
The side nailing strips come attached to the unit.
There are 2 plates, one on the top and bottom
that can be folded out as required depending on
the facing depth as per chart shown.
16 | Regency Bellavista™ B41XTE -10 Gas Fireplace
"C" Screw Position:
For a facing material depth of 1-1/4" (32mm),
the top facing support must be reversed.
Facing Material
Depth
1/2" / 13mm
7/8" / 22mm
1-1/4" / 32mm
|
Flush
Swing door out
from
CONVERSION TO TOP VENT
installation
17
The unit comes equipped as a rear vent unit. These instructions are to be used, only if the unit is going to be top vented.
Top Collar Assembly Kit Includes:
1Intake Collar Assembly with Gasket
1Intake Cover Plate with Gasket
1Top/Rear Exhaust Assembly with Gasket
1Bafe Plate
291/4" x 1/2" Screws (4 spares)
1Restrictor
1Intake Collar Gasket (spare)
1Exhaust Assembly Gasket (spare)
1Insulation Plate Cover
1Insulation Filling
1) Remove the door by releasing the spring hooks at the bottom and lifting
the door up off the door frame.
Note: This conversion must be done prior to the unit being placed in position.
the bottom
and lift up off
of door frame
Door
4) From the outside rear of the rebox, remove the intake collar assembly.
Remove the 4 - 1/4" x 1/2" screws.
Exhaust
Assembly
Intake Collar
Assembly
5) From the outside top of the rebox - remove top insulation cover plate
- by removing 2 screws as shown and discard.
2) From inside the rebox, remove the bafe plate by removing 4 screws
- remove top front screw rst.
Bafe Plate
3) From the inside of the rebox, remove the exhaust assembly by remov-
ing the 10 screws.
6) From the outside top of the rebox - slide the square piece of insulation
out and discard.
7) From the outside top of the rebox - remove the intake cover plate by
removing the 4 - 1/4" x 1/2 " screws.
Before proceeding to Step 8, inspect condition of all gaskets.
DO NOT install parts with damaged gaskets. Replace if necessary with
spare gaskets supplied.
Regency Bellavista™ B41XTE -10 Gas Fireplace | 17
18
|
installation
8) From the outside top of the rebox - completely remove the insulation
under the cover plate as shown and discard.
9) From the outside back of the rebox - locate the insulation deector
and bend completely upwards at against the back of rebox.
IMPORTANT: If the insulation deector is not bent at against the back of
the rebox this will block air intake which will affect the unit's performance.
Insulation Deector
11)From the outside top of the rebox, install the intake collar assembly.
Secure with 4 - 1/4" x 1/2" screws. Ensure all screws are tight, but do not
over tighten. All 4 screws must be used.
Exhaust
Assembly
Intake Collar
Assembly
12)From the outside rear of the rebox, install the intake cover plate with
4 - 1/4" x 1/2" screws. Ensure all screws are tight, but do not over tighten.
All 4 screws must be used.
View Front of Firebox
10) From the inside of the rebox, place the exhaust assembly into position
as shown in Diagram 1 and secure with 10 - 1/4" x 1/2" screws (Diagram
2). Ensure all screws are tight, but do not over tighten.
All 10 screws must be used.
Diagram 1
Diagram 2
13) Set vent restrictor accordingly - see next page.
14) From inside the rebox, re-install the bafe plate from step 2.
15) From inside the rebox, reinstall the top heat deector by placing 2 screws.
Heat Deector
16) From inside the rebox, reinstall the bafe plate by placing 4 screws -
replace top front screw rst. Leave loose - until rear screws installed.
See Diagram 3.
Bafe Plate
Note: Reuse existing screw holes - do not make new holes. Tighten screws.
Diagram 3
Diagram 2
18 | Regency Bellavista™ B41XTE -10 Gas Fireplace
|
installation
19
VENTING INTRODUCTION
The B41XTE uses the "balanced ue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer
liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing
warm room air up the chimney.
946-604/PSimpson Direct Vent -Vent Guard (Optional)946-623/PAstroCap XL Horizontal Cap
770-994Rigid Pipe Adaptor (Must use with all rigid piping)946-506/PVent Guard (Optional)
946-606Starter collar reducer 5” x 8” to 4” x 6-5/8”946-625Vinyl Siding Standoff - AstroCap XL
Note: When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (4DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).
Offset Pipe Selection: Use this table to determine offset pipe lengths.
Pipe Length
(L)
0” (0mm)5-11/16” (144mm)15-5/16” (389mm)Simpson Direct Vent Pro: www.duravent.com
24” (610mm)21-7/16” (697mm)31-1/16” (789mm)Note: Horizontal runs of vent must be level, or have a 1/4”
36” (914mm)29-13/16” (757mm)39-7/16” (1002mm)
48” (1219mm)38-1/4” (972mm)47-7/8” (1216mm)
5” x 8” VentingFor specifi c instructions on venting components - visit the
Run (X)Rise (Y)
manufacturers website listed below.
rise for every 1 foot of run towards the termination.
Never allow the vent to run downward - this could cause high
temperatures and may present a possible fi re hazard.
22 | Regency Bellavista™ B41XTE -10 Gas Fireplace
|
47-1/2"
Horizontal (Feet)
Vertical Height (Feet)
1/2"(0.7m)
Horizontal (Feet)
Rear Venting
installation
23
VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS
FLEX VENT OR RIGID PIPE 5" X 8"
The diagrams show all allowable combinations of vent runs with 5" x 8" venting using the Regency direct vent system or rigid vent system.
A vent guard should be used whenever the termination is lower than the specied minimum or as per local codes.
For horizontal terminations the Regency Direct Vent Flex System may be used for installations upto a maximum continuous vent length of 10ft (3.0m).
Note: Must use optional rigid pipe adaptor (Part # 770-994) when using Rigid Pipe vent systems.
• Maintain clearance to combustibles.
• Horizontal vent must be supported every 3 feet.
• Firestops are required at each oor level and whenever passing through a wall.
12
10
8
6
4
Vertical Height (Feet)
2
0
0
2
Vent Restrictor - Set 1
6
4
Max. 36”(0.9m)
8
(1.2m)
Rigid or Flex
REAR VENTING DEFLECTOR INSTALLATION
FOR REAR VENTED HORIZONTAL TERMINATIONS
0
2
4
6
8
8
6
Max. 36"(0.9m)
4
2
0
Factory Setting - No Restrictor Required
IMPORTANT
Must use Rear Venting Deector packaged with unit in
rear vent horizontal termination applications.
28 -
The Rear Vent Deector comes with the unit. When the unit is shipped
the deector is slightly tucked underneath the top nailing strips located
at the top of the rebox.
NOTE: The Rear Venting Deector must be installed before the unit is
put in place.
1) Secure the rear venting
deector to the wall thimble
using 2 screws as shown.
Ensure to use the same screw
holes as the wall thimble.
Regency Bellavista™ B41XTE -10 Gas Fireplace | 23
Deflector
Rear Venting Deector
24
|
HORIZONTAL TERMINATIONS
FLEX VENT 5" X 8"
These venting systems, in combination with the B41XTE Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by
Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent
Termination Locations" section.
Regency
(Part# 946-616) includes all the parts needed to install the B41XTE with a either a top or rear vent.
installation
®
Direct Vent (Flex) System 4 foot Termination Kit (Part# 946-615), 6 foot Termination Kit (Part# 946-618) or 10 foot Termination Kit
FPI Kit # Length Contains:
#946-6154 Feet1) 8” exible liner (Kit length)
2) 5” exible liner (Kit length)
3) spring spacers
#946-6186 Feet
#946-61610 Feet
4) thimble
5) AstroCapXL termination cap
6) screws
7) tube of Mill Pac
8) plated screws
9) S.S. screws #8 x 1-1/2” drill point
10) vinyl siding standoff
Notes:
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from Regency may be used for Flex installations.
3) Regency® Direct Vent System (Flex) is only approved for horizontal terminations.
NOTE: If longer runs are required the FPI Direct Vent system (Flex) #946-616 includes
all parts needed to install the B41XTE with a maximum 10' run.
24 | Regency Bellavista™ B41XTE -10 Gas Fireplace
Must use Rear Venting Deector
IMPORTANT
packaged with unit in rear vent
horizontal termination applications.
|
ermination
Vinyl Siding
Vi
HORIZONTAL TERMINATIONS
RIGID PIPE 5" X 8"
Horizontal Termination
ATop Vent - No Vertical Rise
• When venting with a 90° elbow directly off the unit
Flex vent or approved Rigid Vent System
• Max. 3 ft. horizontal run
BRear Vent w/ Horizontal Termination
• Max. 3ft. horizontal run
Standoff (Optional)
A
Horizontal
T
Cap
installation
25
Wall Thimble
Pipe Length
o
90 Elbow
Rigid Pipe Adaptor
IMPORTANT
Must use Rear Venting Deector packaged with unit in
rear vent horizontal termination applications.
B
Pipe Length
Rigid Pipe Adaptor
nyl Siding
Standoff (Optional)
Horizontal
Termination
Cap
Wall Thimble
Regency Bellavista™ B41XTE -10 Gas Fireplace | 25
26
A
|
installation
HORIZONTAL TERMINATIONS
ASTROCAP XL & RIGID REAR VENT KIT
FOR CORNER INSTALLATIONS
RIGID PIPE 5" X 8"
Designed for a minimum vent conguration when using a rear vent
application with a horizontal termination in a corner installation.
Kit# 946-612 Includes:
1AstroCap XL946-623/P
1Rigid Pipe Adaptor770-994
1Vinyl Siding Standoff (Optional)946-625
1Wall Thimble58DVA-WT
16" Galvanized Rigid Pipe58DVA-06
18-1/2" Galvanized Pipe Extension58DVA-08A
145º Galvanized Elbow58DVA-E45
190ml MillPac948-128
Vinyl Siding
Standoff
(Optional)
Astrocap
Wall Thimble
XL
Placement of the Unit into the Corner
Back Top Corner of Unit to Wall3"
Inside Corner out along the Wall60-1/4"
Across the Face of the Unit, Wall to Wall85-3/16"
A - Clearance to Outside Corner13"
B - Clearance to Inside Corner5-1/2"
B
3”
60-1/4”
85-3/16”
0
45 elbow
Rigid Pipe Adaptor
Pipe Length
IMPORTANT
Must use Rear Venting Deector packaged with unit in
rear vent horizontal termination applications.
28-1/2” (724mm)
26 | Regency Bellavista™ B41XTE -10 Gas Fireplace
|
Vertical Height (Feet)
installation
VENTING ARRANGEMENTS
FOR HORIZONTAL TERMINATIONS
The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90o (two 45o elbows equal one 90o elbow).
• Maintain clearances to combustibles as listed in "Clearances" section
• Horizontal vent must be supported every 3 feet.
• Firestops are required at each oor level and whenever passing through a wall.
• A wall thimble is mandatory for all horizontal terminations due to high temperatures.
Horizontal (Feet)
4
6
8
101416
12
1820
18
16
0
2
27
14
12
10
Restrictor 1-1/2” Open
Restrictor 2-1/2” Open
Set 2
8
6
4
Set 3
Restrictor 3-1/2” Open
Set 1
47-1/2"
2
(1207mm)
Minimum
Height
Requirement
0
Regency Bellavista™ B41XTE -10 Gas Fireplace | 27
28
Alternate Snorkel
Termination Cap
HOT
Ceiling
|
installation
RIGID PIPE VENTING SYSTEMS
BASIC HORIZONTAL & VERTICAL TERMINATIONS
Rigid Pipe Vent Systems offer a complete line of
component parts for installation of both horizontal
and vertical installations. Many items are offered
in decorative black, as well as galvanized nish.
The minimum components required for a basic
Horizontal Termination are:
1 AstroCap XL Termination Cap
1 90
1 Rigid Pipe Adaptor
1 Wall Thimble
1 Length of rigid pipe to suit wall thickness
The minimum components required for a basic
Vertical Termination are:
1 Vertical Termination Cap
1 Rigid Pipe Adaptor
1 Lengths of pipe to adequately
penetrate roof
1 Ceiling Firestop
1 Flashing
1 Storm Collar
o
Elbow
Vertical Terminal
Storm Collar
Flashing
Firestop
Pipe Length
Pipe
Length
o
90 Elbow
Vinyl Siding
Standoff (Optional)
Pipe Length
AstroCap XL
Termination Cap
(Part #946-623/P)
Wall Thimble
(Mandatory in all
Horizontal Terminations)
Vent Guard-if required*
(Part #946-506/P)
Wall thickness is measured from the back
standoffs to the inside mounting surface of
termination cap. For siding other than vinyl, furring
strips may be used, instead of a vinyl siding
standoff, to create a level surface to mount the
vent terminal. The Terminal must not be recessed
into siding. Measure the wall thickness including
furring strips.
If a Vinyl Siding Standoff is required (it must be
used with vinyl siding), measure to outside surface
of wall without siding and add 2 inches.
WARNING:
Do not combine venting components from
different venting systems.
Exception: However, use of the the AstroCap
XLTM is acceptable with all systems.
This product has been evaluated by Intertek for
using a Rigid Pipe Adaptor in conjunction with
Simpson DV Pro, Metal-Fab Sure-Seal, ICC
Excel and Selkirk Direct-Temp systems. Use
of these systems with the Rigid Pipe adaptor
is deemed acceptable and does not affect the
Warnock Hersey/Intertek listing of components.
Rigid Pipe
Adaptor (770-994)
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
Alternate
Horizontal Termination
Caps
The FPI AstroCap XL
Direct-Temp. AstroCap XLTM is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or
proprietary trademarks of Simpson Dura-Vent Co. Inc.
28 | Regency Bellavista™ B41XTE -10 Gas Fireplace
TM
is certied for installations using FPI venting systems as well as Simpson Dura-Vent® Direct Vent Pro, ICC Excel and Selkirk
|
HORIZONTAL TERMINATIONS
TWO (2) 90O ELBOWS (RIGID PIPE 5" X 8")
One 90oelbow=Two45oelbows.
OptionV H + H1
A)0' Min.2' Max.
B)1' Min.3' Max.
C)2' Min.4' Max.
D)3' Min.5' Max.
E)4' Min.6' Max.
F)5' Min.7' Max.
G)6' Min.8' Max.
No Vent Restrictor Installed
Lengths do not include elbow indicated.
Must use rigid pipe adaptor #770-994.
With these options,
maximum total pipe
length is 30 feet with
minimum of 6 feet total
total pipe length
is 30 feet with
minimum of 6 feet
total vertical and
maximum 8 feet
total horizontal.
Pleasenoteminimum 1 foot be-
tween 90o
elbowsis
required.
30
Horizontal (Feet)
|
installation
VENTING ARRANGEMENTS FOR VERTICAL TERMINATIONS
The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90o elbows, with
Rigid Pipe Venting Systems for Propane and Natural Gas. Two 45
0
2
40
38
36
34
32
30
28
26
Restrictor 1-1/2” Open
24
22
o
elbows equal to one 90o elbow. Maximum of four 45o elbows allowed.
6
410
Set 3
8
12
20
18
Vertical Height (Feet)
16
14
12
10
8
6
4
2
0
Restrictor 2-1/2” Open
Set 2
Restrictor 3-1/2” Open
Set 1
Maximum 10’ Centerline to Centerline
(1.2m)
Min. 47-1/2”
Maximum 8’ Centerline to Centerline
8’ (2.4m)
Minimum
• Vent must be supported at offsets.
• Firestops are required at each oor level and whenever passing through a wall.
• Maintain clearances to combustibles as listed in the "Clearances" section.
• Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting
to 3-1/2" opening, 2-1/2"opening and to 1-1/2" opening.
Note: Must use optional ue adapter when using Rigid Pipe (Part # 770-994).
30 | Regency Bellavista™ B41XTE -10 Gas Fireplace
|
VERTICAL TERMINATIONS
THREE (3) 90O ELBOWS (RIGID PIPE 5" X 8")
One 90oelbow=Two45oelbows.
OptionV V + V1 H + H1
A)0' Min.2' Min.2' Max.
B)1' Min.3' Min.2' Max.
C)2' Min.4' Min.3' Max.
D)3' Min.6' Min.4' Max.
E)4' Min.7' Min.5' Max.
F)5' Min.8' Min.6' Max.
G)6' Min.9' Min.7' Max.
H) 7' Min
No Vent Restrictor Installed
Lengths do not include elbow indicated.
Must use rigid pipe adaptor #770-994
10' Min. 8' Max.
With these options,
maximum total pipe length
is 30 feet with minimum
of 6 feet total vertical
* Clearances noted below must be maintained;
except when passing through a wall, ceiling or at the
termination where the use of a restop or wall thimble
reduces clearance to 1-1/2" (38mm).
Horizontal Top*3" (76mm)*
Horizontal Side2 " (51mm)
Horizontal Bottom2" (51mm)
Vertical Vent2" (51mm)
Below are the recommended framing dimen-
sions (inside measurements) for the 5" x 8"
rigid vent terminations - for use with a restop
or wall thimble.
Install the vent system according to the
manufacturer's instructions included with the
components.
1) Set the unit in its desired location. Check to
determine if wall studs or roof rafters are in
the way when the venting system is attached.
If this is the case, you may want to adjust
the location of the unit. Rough in the gas
preferably on the right side of the unit and
the electrical (junction block is on the left
side) on the left.
2) Direct Vent pipe and ttings are designed with
special twist-lock connections to connect the
venting system to the appliance ue outlet.
A twist-lock appliance adaptor is required.
3) In conjunction with the Approved Vent system,
install the adaptor after the unit is set in its
desired location. Slip the adapter over the
existing inner and outer ue collar. Fasten
to the outer collar only with the 3 supplied
screws (drilling pilot holes will make this
easier).
4) Level the replace and fasten it to the framing
using nails or screws through the top and
side nailing strips.
5) Assemble the desired combination of pipe
and elbows to the appliance adaptor and
twist-lock for a solid connection.
Note: For best results and optimum
performance with each approved
venting system, it is highly
recommended to apply “Mill-Pac”
sealant (supplied) to every inner pipe
connection. Failure to do so may result
in drafting or performance issues not
covered under warranty.
Horizontal runs of vent must be supported
every 3 feet (0.9meter). Wall straps are
available for this purpose.
6) Mark the wall for a square hole.-see chart to
left for size. The center of the square hole
should line up with the center-line of the
horizontal pipe. Cut and frame the square
hole in the exterior wall where the vent will
be terminated. See diagram 2 for center line
requirements.
If the wall being penetrated is constructed of
non-combustible material, i.e. masonry block
or concrete, an 8" (203mm) diameter hole
is acceptable.
Note:
a) The horizontal run of vent must be level,
or have a 1/4 inch rise for every 1 foot
of run towards the termination. Never
allow the vent to run downward. This
could cause high temperatures and may
present the possibility of a re.
b) The location of the horizontal vent
termination on an exterior wall must meet
all local and national building codes, and
must not be blocked or obstructed. See
"Exterior Vent Termination Locations"
section for more details.
of hole
C
L
C
L
” x 8 ”)
7) Ensure that the pipe clearances to
combustible materials are maintained
(Diagram 5). Install the termination cap.
Note: If installing termination on a vinyl
siding covered wall, a vinyl siding
standoff or furring strips must be used
to ensure that the termination is not
recessed into the siding.
Diagram 5
The four wood screws provided should be re-
placed with appropriate fasteners for stucco,
brick, concrete, or other types of sidings.
8) Before connecting the horizontal run of vent
pipe to the vent termination, slide the Wall
Thimble over the vent pipe. The wall thimble
is required for all horizontal terminations.
9) Slide the appliance and vent assembly
towards the wall carefully inserting the vent
pipe into the vent cap assembly. It is important
that the vent pipe extends into the vent cap
sufcient distance so as to result in a minimum
pipe overlap of 1-1/4 inches (32mm). Secure
the connection between the vent pipe and
the vent cap.
10) Install wall thimble in the center of the framed
hole and attach with wood screws (Diagram
7).
Diagram 1
32 | Regency Bellavista™ B41XTE -10 Gas Fireplace
” (1207mm)
(724mm)
Rear Vent
Diagram 2
Must use Rear Venting Deector packaged with unit
in rear vent horizontal termination applications.
IMPORTANT
47-1/2
Min. height (5
Diagram 7
|
p
28-1/2”
center
installation
33
UNIT INSTALLATION WITH
HORIZONTAL TERMINATION
5" X 8" VENTING
(FlexVentSystems)
Minimum Vent Clearances
to Combustibles
* Clearances noted below must be maintained;
except when passing through a wall, ceiling or at the
termination where the use of a restop or wall thimble
reduces clearance to 1-1/2" (38mm).
Horizontal Top3" (76mm)
Horizontal Side2 " (51mm)
Horizontal Bottom2" (51mm)
Vertical Vent2" (51mm)
Below are the recommended framing
dimensions (inside measurements) for the
5" x 8" rigid vent terminations - for use with a
restop or wall thimble.
Recommended Framed
Opening Size
Vent SizeFraming Size
5" x 8"11" x 11"
1) Locate the unit in the framing, rough in the
gas (preferably on the right side of the unit).
Locate the centerline of the termination and
mark wall accordingly. Cut an square hole in
the wall - see chart (inside dimension).
Note: If installing termination on a siding
covered wall, a vinyl siding standoff
or vinyl furring strips must be used
to ensure that the termination is not
recessed into the siding.
NOTE: Horizontal sections must be sup-
ported at intervals not exceeding 3
feet (0.9 meter). (Flame picture and
performance will be affected by sags
in the liner).
4) Separate the 2 halves of the wall thimble and
securely fasten the one with the tabs to the
outside wall making sure that the tabs are
on top and bottom. Fasten the other thimble
half to the inside wall. The thimble halves
slip inside each other and can be adjusted
for 2 x 4 or 2 x 6 walls.
5) Slip the assembled liner and termination
assembly through the thimble making sure
the termination cap faces up (there are
markings on the cap that show which wayis
up). This will position the termination cap
with proper down slope for draining water.
Fasten the cap to the outer wall with the 4
supplied screws.
6) Pull the centre inner and outer ex liner out
enough to slip over the ue collars of the
replace. (You may wish to cut the liner
shorter to make it more workable.) Do not
bend liner more than 90
slipoverthecollarsaminimumof1-3/8".
7) Apply Mill Pac over the replace inner ue
collar and slip the inner ex liner down over
it and attach with 3 supplied screws.
8) Do the same with the outer ue collar and
outer ex liner.
9) Apply a bead of silicone between the thimble
and termination and around the outer edge
of the terminal at the wall in order to keep
the water out.
o
. Thelinersmust
IMPORTANT: Do not locate termination
hood where excessive snow or ice
buildup may occur. Be sure to check vent
termination area after snow falls, and clear
to prevent accidental blockage of venting
system. When using snow blowers, make
sure snow is not directed towards vent
termination area.
ASTROCAP XL
DIMENSIONS (946-623/P)
of hole
C
L
(724mm)
Rear Vent
Must use Rear Venting Deector
packaged with unit in rear vent
horizontal termination applications.
IMPORTANT
C
L
” x 8”)
” (1207mm)
47-1/2
Min. height (5
2) Level the replace and fasten it to the fram-
ing using nails or screws through the nailing
strips.
3) Assemble the vent assembly by applying
Mill Pac to the inner ue collar of the termination and slipping the inner ex liner over
it at least 1-3/8" (35mm). Fasten with the
3 screws (drilling pilot holes will make this
easier). Apply Mill Pac or high temperature
silicone to the outer ex pipe and slip it over
the outer ue collar of the vent terminal at
least 1-3/8"(35mm) and fasten with the 3
screws.
Regency Bellavista™ B41XTE -10 Gas Fireplace | 33
2” x4”or2”x6”
5” dia. flue pipe
with spring spacer
AstroCap XL
Termination Ca
8" dia.
air intake
Screws
Vinyl Siding
Screws
Wall Thimble
34
framing
|
installation
UNIT INSTALLATION WITH
VERTICAL TERMINATION
5" X 8" VENTING
(RigidVentSystems)
MUST USE RIGID PIPE
ADAPTOR #770-994
* Clearances noted below must be maintained;
except when passing through a wall, ceiling or at the
termination where the use of a restop or wall thimble
reduces clearance to 1-1/2" (38mm).
1) Maintain the 2" clearances (air
spaces) to combustibles when
passing through ceilings, walls,
roofs, enclosures, attic rafter,
or other nearby combustible
surfaces. Do not pack air spaces
with insulation. Check "Venting"
Sections for the maximum
vertical rise of the venting
system and the maximum
horizontal offset limitations.
2) Set the gas appliance in
its desired location. Drop
a plumb bob down from
the ceiling to the position
of the appliance ue exit,
and mark the location where the vent will
penetrate the ceiling. Drill a small hole at
this point. Next, drop a plumb bob from
the roof to the hole previously drilled in the
ceiling, and mark the spot where the vent
will penetrate the roof.
Diagram 1
4) Assemble the desired lengths of pipe and
elbows. Ensure that all pipes and elbow con-
nections are in the fully twist-locked position
and sealed.
NOTE: For best results and optimum
performance with each approved venting
system, it is highly recommended to apply
“Mill-Pac” sealant (supplied) to every inner
pipe connection. Failure to do so may result
in drafting or performance issues not covered
under warranty.
5) Cut a hole in the roof centered on the small
drilled hole placed in the roof in Step 2. The
hole should be of sufcient size to meet
the minimum requirements for clearance to
combustibles of 2". Slip the ashing under
the shingles (shingles should overlap half
the ashing) as per Diagram 3.
Diagram4
Roof Pitch Minimum Vent Height
Feet Meters
at to 7/12 2 0.61
over 7/12 to 8/12 2 0.61
over 8/12 to 9/12 2 0.61
over 9/12 to 10/12 2.5 0.76
over 10/12 to 11/12 3.25 0.99
over 11/12 to 12/12 4 1.22
over 12/12 to 14/12 5 1.52
over 14/12 to 16/12 6 1.83
over 16/12 to 18/12 7 2.13
over 18/12 to 20/12 7.5 2.29
over 20/12 to 21/12 8 2.44
7) Ensure vent is vertical and secure the base
of the ashing to the roof with roong rails,
slide storm collar over the pipe section and
seal with a mastic.
8) Install the vertical termination cap by twist-
locking it.
Note: Any closets or storage spaces, which the
vent passes through must be enclosed.
GAS LINE
INSTALLATION
3) A Firestop spacer must be installed in the
oor or ceiling of every level. To install the
Firestop spacer in a at ceiling or wall, cut
a 11 inch square hole. Frame the hole as
shown in Diagram 2 and install the restop.
Note: All vertical terminations are vented using 5" x 8" venting and rigid pipe
adaptor #770-994.
11“(279mm)
square hole
11”
11”
firestop
spacer
Diagram 2
34 | Regency Bellavista™ B41XTE -10 Gas Fireplace
Diagram 3: The upper half of the ashing is
installed under the roong material and not
nailed down until the chimney is installed. This
allows for small adjustments.
6) Continue to assemble pipe lengths.
Note: If an offset is necessary in the attic to
avoid obstructions, it is important to
support the vent pipe every 3 feet, to
avoid excessive stress on the elbows,
and possible separation. Wall straps
are available for this purpose.
Galvanized pipe is desirable above the rooine
due to its higher corrosion resistance. Continue
to add pipe sections through the ashing until
the height of the vent cap meets the minimum
height requirements specied in Dia. 4 or local
codes. Note that for steep roof pitches, the
vertical height must be increased. A poor
draft, or down drafting can result from high
wind conditions near big trees or adjoining
roof lines, in these cases, increasing the
vent height may solve the problem.
The gas line is brought through the right side of
the appliance. The gas valve is situated on the
right hand side of the unit and the gas inlet is
on the right hand side of the valve.
The gas line connection may be made of rigid
pipe, copper pipe or an approved ex connector.
(If you are using rigid pipe, ensure that the valve
can be removed for servicing.) Since some
municipalities have additional local codes it is
always best to consult with your local authorities
and the CAN/CGA B149 installation code.
For USA installations follow local codes and/
or the current National Fuel Gas Code, ANSI
Z223.1.
When using copper or ex connectors use only
approved ttings. Always provide a union so
that gas lines can be easily disconnected for
servicing. Flare nuts for copper lines and ex
connectors are usually considered to meet this
requirement.
Important: Always check for gas leaks with a
soap and water solution or gas leak detector.
Do not use open ame for leak testing.
|
1
2
3
4
1
2
3
4
6
5
7
installation
35
PILOT ADJUSTMENT
Periodically check the pilot ames. Correct
ame pattern has two strong blue ames:
1 owing around the ame sensor and 1
owing across the burner (it does not have
to be touching the burner).
Burner
Flame Sensor
Pilot
Note: If you have an incorrect ame pattern,
contact your Regency
further instructions.
Incorrect ame pattern will have small,
probably yellow ames, not coming into
proper contact with the rear burner or ame
sensor.
Ignitor
®
dealer for
HIGH ELEVATION
This unit is approved in Canada for altitude to
4500 ft. (CAN/CGA-2.17-M91). For Natural Gas
installations above 4500 ft. follow current CAN/
CGA-B149.1.
B41XTE -NG10 System Data
For 0 to 4500 feet altitude
Burner Inlet Orice Sizes: #30
Max. Input Rating 42,500 Btu/h
Min. Input Rating 30,000 Btu/h
Supply Pressure min.5.0" w.c.
Manifold Pressure
(High) 3.5"+/- 0.2" w.c.
Manifold Pressure
(Low) 1.6"+/- 0.2" w.c.
B41XTE - LP10 System Data
For 0 to 4500 feet altitude
Burner Inlet Orice Sizes: #49
Max. Input Rating 37,500 Btu/h
Min. Input Rating 29,500 Btu/h
Supply Pressure min.11.0" w.c.
Manifold Pressure
(High) 10"+/- 0.2"w.c.
Manifold Pressure
(Low) 6.4"+/- 0.2"w.c.
GAS PIPE
PRESSURE TESTING
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut-off valve during any pressure
testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig.
(3.45 kPa). Disconnect piping from valve at
pressures over 1/2 psig.
The manifold pressure is controlled by a regulator
Must install one of the following: Brick Panels, Stainless Steel or Black Enamel Panels.
Dangerous operating conditions may occur if the panels are not installed or if installed with broken panels.
1) Unwrap the Brick Panels from the protective wrapping.
Left Panel
2) Ensure that the logs are not in the unit.
3) Prior to installation of the brick panels, remove the top panel bracket
currently fi tted into the baffl e opening on the inside top of the fi rebox.
See diagram below.
Top Panel
Handle with care. DO NOT FORCE INTO POSITION.
Right PanelBack Panel
6) Slide the top brick panel under the left or right side panel (which ever
is installed fi rst - right side panel shown here) and back brick panel,
use care not to damage panel.
7) Install the remaining side panel (left or right), following the same
instructions as step 5.
Top Panel Bracket
4) Install the back brick panel fi rst - use caution when clearing the
burner assembly and rear log tray so that the panel does not get
damaged.
Note: Ensure that the back panel is centered.
Back Panel Installed
5) Install either the left or right side brick panel by removing the screw
and brick clip on the upper side of the fi rebox wall (left side shown).
Position the left brick panel in place and secure with the brick panel
clip and screw removed from the fi rebox as shown below.
8) Carefully position and fi t the top bracket in place by ensuring the tabs
of the bracket fi t into the baffl e openings as shown in the diagram 1
below. Push downwards to secure the bracket to the top panel.
36 | Regency Bellavista™ B41XTE -10 Gas Fireplace
|
B41XT
OPTIONAL BLACK ENAMEL
PANEL INSTALLATION
installation
37
OPTIONAL BLACK ENAMEL PANEL INSTALLATION
• Black Enamel panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time.
Claims for damage after installation will not receive consideration.
• Black Enamel panels will discolor a little during normal operation. This is normal and should not be considered a defect.
All hand and fi nger marks MUST be cleaned off with a soft cloth. Use an ammonia based cleaner (ie. glass cleaner) to remove any
*
fi ngerprints before applying heat to the unit.
Failure to do this will result in burn stains on panels which you will be unable to remove. Not protected by product warranty.
Note: Panels must be installed prior to the installation of the log set and vermiculite.
LEFT
Black Enamel Panels
TOP
BACK
RIGHT
1) Prior to installation of the refl ective panels, remove the top panel
bracket currently fi tted into the baffl e opening on the inside top of
the fi rebox. See diagram below.
Top Panel Bracket
2) Install the back stainless panel fi rst - be careful not to scratch the
panel on the burner or log tray when installing. Ensure the back
panel is centered when installed.
3) Install the right side panel - secure with panel clip and 1 screw.
See step 3.
Back Panel
Right Side Panel
Regency Bellavista™ B41XTE -10 Gas Fireplace | 37
38
B41XT
|
installation
4) Remove 1 screw (see inset A), position right side panel in fi rebox -
position panel clip in place and secure with 1 screw (see inset B).
Tighten the screw.
Location of hex
head screw
A
B
5) Slide top panel under the top of the back and right side panels as
shown below.
7) Carefully position and fi t the top bracket in place by ensuring the
tabs of the bracket fi t into the baffl e openings as shown below. Push
downwards to secure the bracket to the top panel.
Top panel bracket shown installed
with Stainless Steel Panels
6) Install left side panel - repeat step 4.
38 | Regency Bellavista™ B41XTE -10 Gas Fireplace
|
B41XT
LOG SET INSTALLATION
installation
39
LOG SET INSTALLATION
Installation of Brick or Black Enamel Panels must be completed before installing the log set.
Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replac ed. Broken
logs can interfere with pilot operation.
Improper positioning of the logs may create carbon build-up and can alter the unit's performance which is not covered under warranty.
Log Kit# 506-930 contains the following pieces:
ARear Bottom Right Log
BRear Top Left Log
CRight Top Cross Log
DFront Log Piece
ELeft Top Cross Log
FCenter Right Log
GFront Bottom Left Log
HFront Bottom Right Log
ICenter Left Log
902-156Lava Rocks
902-179Vermiculite
946-669Platinum Embers
(supplied w/packaged manual)
I
B
E
G
F
A
C
H
1) Carefully remove the logs from the packaging and unwrap them. The
logs are fragile, handle with care - do not force into position.
2) Spread vermiculite along the base of the fi rebox.
Diagram 2
Vermiculite
D
Diagram 1
3) Place Log A on the rear log support pins with the fl at side to the back.
A
Diagram 3–Log A
4) Place Log F on the right side of the burner, directly in front of Log A.
Position Log F so it fi ts into the pin on the burner as shown below.
F
Regency Bellavista™ B41XTE -10 Gas Fireplace | 39
40
B41XT
|
installation
5) Place Log I on the left side of the burner, directly in front of Log A.
6) When Log F and I are in position - make sure they positioned all the
way back and touch the tabs on the burner as shown below.
Position Log I so it fi ts into the pin on the burner as shown below.
I
Diagram 4–Log I
8) Slide the left side of Log G back until it touches the tab on the burner
shown below.
Tab on Burner
Back of Log G
Diagram 7–Back of Log G
9) Place Log H on the right front side of the burner in front of log F.
Position Log G so it fi ts into the pin on the burner as shown below.
There is a notch on the bottom of log H - position the log so the notch
fi ts over the 5th burner grate tab as shown below.
I
Diagram 5– location of back
tabs on Burner
7) Place Log G on the left front side of the burner in front of log I.
Position Log G so it fi ts into the pin on the burner as shown below.
F
G
Diagram 6–Log G
H
Notch - Log HBurner Grate Tab
Diagram 8
10) Slide the right side of Log H back until it touches the tab on the burner
shown below.
Tab on Burner
H
Back of Log H
Diagram 9
40 | Regency Bellavista™ B41XTE -10 Gas Fireplace
|
B41XT
H.
the
installation
41
11) Position Log E on top of Log G - fi t Log E into the pin on Log G as
shown below.
E
G
Diagram 10
12) With Log E in position on Log G - ensure that Log E touches the
back corner of Log A as shown below.
B
E
Diagram 13
14) Position Log C on top of Log H. Log C fi ts into the pin in Log
as shown below.
C
A
E
Diagram 11
13) Position Log B on top of Log A. Log B fi ts into the pin in Log A.
Ensure Log B sits upright 90 degrees with the left side of the log
resting on the notch in Log E. See next 2 diagrams.
B
A
Diagram 14
15) With Log C in position on Log H - assure that Log C contacts
back corner of Log A as shown below.
A
C
Diagram 15
Diagram 12
Regency Bellavista™ B41XTE -10 Gas Fireplace | 41
42
B41XT
|
installation
16) Place the lava rocks on the burner in front of the logs as shown below.
Be careful not to overlap the lava rock and ensure the burner ports
are left exposed in front of Logs E and H as shown below.
Diagram 16
IMPORTANT:
Do not cover burner ports
with lava rocks as this will
change the fl ame pattern.
17) Separate platinum embers and place on the front burner on and
around the lava rocks. Avoid stacking platinum embers.
Platinum embers may be placed over burner ports.
Diagram 18– Platinum Embers
18) Place Log D on the base of the fi rebox in between burner grate posts
3 and 4.
Note: Extra lava rocks can be placed on the vermiculite on the fl oor
of the fi rebox - see below.
Diagram 17– Extra Lava Rocks
D
Burner Grate Post 3Burner Grate Post 4
Diagram 19
19) Test fi re to ensure proper lighting (make sure fl ame fl ows
smoothly from one end of the burner to the other).
If there is any fl ame hesitation, check that area for any blockage of
the burner ports.
42 | Regency Bellavista™ B41XTE -10 Gas Fireplace
|
installation
43
WIRING DIAGRAM
This heater does not require a 120V A.C. supply for operation but it is highly recommended to install the supplied AC adaptor to eliminate the need for
batteries. In case of a power failure, the burner switch and the optional remote control will continue to operate if batteries are installed in the receiver..
However, a 120V A.C. power supply is needed for the fan/blower operation.
(Do not cut the ground terminal off under any circumstances.)
NOTE: Even if the fan is not purchased with the unit, it is still a good idea to bring power to the receptacle box (provided with the unit) in case
the fan is installed at a later date.
Proflame System
Configuration
885
886 GTMF
Wire Diagram
SureFire™ Switch
AC Adaptor
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.
Regency Bellavista™ B41XTE -10 Gas Fireplace | 43
44
AC POWER ADAPTOR INSTALLATION (FOR SUREFIRE SYSTEMS)
|
installation
AC ADAPTOR INSTALLATION
An AC power adaptor is supplied with this appliance and may be installed as a constant power source for the SureFire system.
NOTE: AC power adaptor is not required when using GTMF Remote with fan control module and must be disconnected.
IMPORTANT: Recommend removing the 4-AA batteries in the SureFire receiver.
This will avoid battery leakage and power drainage. 4-AA Battery pack may be re-installed into receiver during power outages.
1. Plug AC adaptor into a 120V wall outlet or into the 120V
receptacle if installed inside the gas replace.
2. Tuck any loose wires neatly underneath the rebox–inside
the replace.
Note: Ensure that wires do not touch the underside of the re
box (Keep wires away from heat as much as possible).
Wire adaptor
AC adaptor
44 | Regency Bellavista™ B41XTE -10 Gas Fireplace
|
9) Slide the thermodisc/cover assembly onto the bracket clip on the
left underside of the fi rebox. Ensure that no wires will touch hot
surfaces.
B41XTE
OPTIONAL FAN INSTALLATION
Important: 120 Volt AC power is needed for the fan switch and blower.
The receptacle box will be installed on the left hand side of the unit
and must be wired by a qualifi ed electrician prior to fan
assembly being installed. The neutral(wider) slot of the polarized
receptacle should be at the top.
Ground terminal must not be removed.
Unit must be grounded at all times.
1) Turn the power off, unplug accent lights if installed.
2) Remove the mesh barrier and the standard fl ush door.
3) Remove fan assembly from box, locate green ground wire and pull
out of fan assembly - taking care not to damage or cut wire casing.
4) Position the fan base with the motor end towards the rear of the
fi rebox and then slide the fan in towards the rear of the unit. Turn
the fan housing slightly to the left and make the fan assembly parallel to the rear wall.
5) Lift the fan housing upwards and slip it over the two mounting
studs. (use of dish soap will help the rubber grommets slide down
over the pins)
NOTE: If optional accent lights are installed,take care when sliding the
fan into position. Fan must be maneuvered around the right
side of the light.
8) Plug fan power cord into the Fan Control Module (FCM) then plug
in the FCM. The switch is on when pushed to the left. (Shown in OFF
position above)
7) Connect and secure fan ground cable to ground lug.
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.
Regency Bellavista™ B41XTE -10 Gas Fireplace | 47
48
B41XT
OPTIONALACCENT LIGHT INSTALLATION
|
installation
OPTIONAL ACCENT LIGHT INSTALLATION
Accent Light Assembly Kit
1910-814Plug wiring + gasket
2910-997Halogen Bulb
2940-363Amber Glass
1Light AssemblyIncludes gaskets (x 2)
1918-864Instruction Sheet
Important: 120 Volt AC power is required for the optional light.
The receptacle box will be installed on the lower left corner of
the unit and will need to be wired by a qualifi ed electrician prior
to the optional light installation. The neutral (wider) slot of the
polarized receptacle should be at the top. A wall mounted switch
should be installed to turn the accent lighting on/off.
See wiring diagram in the instruction manual.
1) Shut off electrical supply.
2) Remove Full Screen Door and bottom Louver if installed.
3) Remove the glass door - see instructions in manual.
4) Remove the logs, lava rock and vermiculite if installed.
5) Remove the brick or inner panels if installed - see instructions in manual.
9) Remove the 2 screws securing the base tray - lift base tray up and
out. Diagram 4a and 4b.
Diagram 4a
Diagram 4b
10) Remove the 2 cover plates from the fl oor of the fi rebox by removing
2 screws from each plate.
Base Tray
6) Remove the burner and rear log tray - see below.
Diagram 1: Remove the left and right screws.
7) Slide the burner assembly to the right to release it from the orifi ce,
then lift it out.
Diagram 2: Slide burner assembly to the right
and then remove.
8) Remove the 2 screws securing the rear log tray and lift out. Diagram 3
11) Remove the cover plate and gasket from the underside of the fl oor of
thru the underside of the fi rebox base. Left side shown, repeat for
right side.
Diagram 3
48 | Regency Bellavista™ B41XTE -10 Gas Fireplace
|
B41XT
installation
49
13) Install each light assembly from the underside of the fl oor of the
fi rebox. Secure with 2 screws as shown below.
15) Install two light diffusers on to the base tray.
16) Secure diffusers onto base tray from the backside of the tray
with 2 screws.
NOTE: The ground wire will need to be pulled back out of the protective
casing to be able to reach the ground lug. Gently pull the end
of the green wire backwards exposing enough wire to reach
ground lug.
14) Install a bulb into each light assembly.
Note: Oils from hands will shorten the life of the bulbs,
do not handle bulbs with bare hands.
17) Reinstall base tray with light diffusers - use caution when installing
do not damage the bulb.
18) Install amber glass on to light diffusers.
Note: Glass is longer than diffuser for ease of removal.
Regency Bellavista™ B41XTE -10 Gas Fireplace | 49
19) Reverse steps 9 - 1.
50
B41XT
ELECTRICAL WORK MUST BE
PERFORMED BY A QUALIFIED
ELECTRICIAN
LINE VOLTA GE WIRING TO RECEPTACLE IN UNIT
TO MAKE OUTLETS INDEPENDENT OF EACH OTHER
AC Adaptor
|
installation
50 | Regency Bellavista™ B41XTE -10 Gas Fireplace
|
B36XTe / B41XTe
Finishing
Trim Top
Finishing
Trim Side
OPTIONAL fINIshINg TrIm INsTALLATION
1)
Install the Finishing Trim sides as shown in the diagram; line up the holes in the
side trim with the holes in the rebox side.
2) Secure with 2 screws per side.
3) Loosen the 3 screws in the top inside edge of the rebox.
4) Slide the Finishing Trim Top over the Side Trim pieces and t the
bottom bracket slots over the screws. Tighten the 2 screws to
secure in place.
Finishing Trim
Edge of Unit
B41XTE B36XTE
W
43-3/8"40-1/2"
H
37-5/8"35-3/4"
FLUSH GLASS DOOR INSTALLATION
installation
51
The standard ush door comes with a black frame. To install the frame,
simply hook the top door ange onto the top of the unit and swing the
door towards the unit, see Diagram 1.
Diagram 1
Be careful that the glass gasket does not roll up; there must be a gap
between the gasket and the door lip to ensure that the door sits securely
on the unit, see Diagram 2.
Diagram 2
Use the hook to pull the spring out until you can put the hook into the
slot on the bottom door bracket. Repeat for 2nd spring. See Diagram 3.
OPTIONAL FINISHING TRIM INSTALLATION
Diagram 3
To remove the ush door, reverse the above steps.
Regency Bellavista™ B41XTE -10 Gas Fireplace | 51
52
B41XTE
VIGNETTE AND SAFETY SCREEN INSTALLATION
Note: If using the optional 3 Sided Finishing Trim you must install it prior to installation of the Vignette Frame and Screen.
1. Remove glass front and carefully set to the side. (Refer to instructions
in the manual)
2. Loosen the top screws slightly (approximately 3/16") as shown on
both the right and left sides.
(Left side shown)
3. Reinstall glass front removed in Step 1.
4. Line up Vignette Frame to unit and hook the frame on to the appliance.
Slide the top of the frame (See Detail AA above) on to the screws.
(See Detail A shown above)
AA
A
5. Lower bottom end of frame (Detail BB) gently into bottom of bracket.
(Detail B)
BB
B
6. Line up the tabs on the screen assembly with the slots in the outer frame
and lower gently into place. Bring bottom of the screen assembly toward
the front of the appliance until it comes into contact with the magnets
7. Reverse the steps to remove.
Black Chrome Handling Instructions
*
All hand and nger marks MUST be cleaned off with a soft cloth. Use an ammonia based cleaner (ie. glass cleaner) to remove any
nger prints before applying heat to the unit. Use supplied gloves when installing Black Chrome Faceplates.
Failure to do this will result in burn stains on panels which you will be unable to remove. Not protected by product warranty.
|
installation
VIGNETTE FRAME AND SAFETY SCREEN INSTALLATION
52 | Regency Bellavista™ B41XTE -10 Gas Fireplace
|
operating instructions
53
OPERATING
INSTRUCTIONS
1) Read and understand these instructions
before operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the glass in the door frame is
properly positioned. Never operate the
appliance with the glass removed.
5) Verify that the venting and cap are
unobstructed.
6) Ensure that the brick panels are installed.
7) Verify log placement. If the pilot cannot be
seen when lighting the unit, the logs have
been incorrectly positioned.
8) The unit should never be turned off, and on
again without a minimum of a 60 second
wait.
FIRST FIRE
The rst re in your replace is part of the
paint curing process. To ensure that the paint
is properly cured, it is recommended that you
burn your replace for at least four (4) hours the
rst time you use it with the fan on.
When rst operated, the unit will release an odour
caused by the curing of the paint, the burning
off of any oils remaining from manufacturing.
Smoke detectors in the house may go off at
this time. Open a few windows to ventilate the
room for a couple of hours.
The glass panel may require cleaning after the
unit has cooled down.
NORMAL OPERATING
SOUNDS OF
GAS APPLIANCES
It is possible that you will hear some sounds
from your gas appliance. This is perfectly
normal due to the fact that there are various
gauges and types of steel used within your
appliance. Listed below are some examples.
All are normal operating sounds and should
not be considered as defects in your appliance.
Burner Tray:
The burner tray is positioned directly under the
burner and is made of a different gauge material
from the rest of the rebox and body. Therefore,
the varying thicknesses of steel will expand and
contract at slightly different rates which can cause
"ticking" and "cracking" sounds. You should also
be aware that as there are temperature changes
within the unit these sounds will likely re-occur.
Again, this is normal for steel reboxes.
Pilot Flame:
While the pilot ame is on it can make a very
slight "whisper" sound.
Gas Control Valve:
As the gas control valve turns ON and OFF, a
dull clicking sound may be audible, this is normal
operation of a gas regulator or valve.
Unit Body/Firebox:
Different types and thicknesses of steel will
expand and contract at different rates resulting
in some "cracking" and "ticking" sounds will be
heard throughout the cycling process.
Blower Thermodisc:
When this thermally activated switch turns ON
it will create a small "clicking" sound. This is the
switch contacts closing and is normal.
AERATION ADJUSTMENT
The burner aeration is factory set but may need
adjusting due to either the local gas supply or
altitude. Open the air shutter for a blue ame or
close for a more yellow ame.
Minimum Air Shutter Opening:
NG: 1/4" LP: 1/2"
CAUTION: Carbon will be produced if air shutter
is tightly closed.
Note: Any damage due to carboning
resulting from improperly setting
the aeration controls is NOT covered
under warranty.
Air shutter rod: located to the left
of the valve assembly.
DO NOT ATTEMPT TO CLEAN THE
GLASS WHILE IT IS HOT.
Note: When the glass is cold and the
appliance is lit, it may cause
condensation and fog the glass.
This condensation is normal and will
disappear in a few minutes as the glass
heats up.
DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.
During the rst few res, a white lm
may develop on the glass front as part
of the curing process. The glass should
be cleaned or the lm will bake on and
become very difcult to remove. Use a
non-abrasive cleaner and NEVER clean
the glass while it is hot.
Regency Bellavista™ B41XTE -10 Gas Fireplace | 53
54
|
operating instructions
LIGHTING PROCEDURE
IMPORTANT: The remote control system supplied with this appliance has
several options for starting/operating the appliance using the power button
and ON/OFF key on the hand held transmitter.
Prior to operating this appliance, please read the remote control operating
instructions (packaged with remote control) to understand how to operate
this remote control system. Option to download remote functions video
with QR code below.
Proame
video
3. After approximately 4 seconds the spark ignition system will spark for 60
seconds to light the main burner.
4. The unit will turn on.
Note: The rst try for ignition will last approximately 60 seconds. If there is no
ame ignition (rectication) the board will stop sparking for approximately
35 seconds. After wait time , the board will start second try for ignition by
sparking for approximately 60 seconds . If there is still no positive ignition
the board will go into lock out.
1. Ensure the wall switch/receiver is in the remote position. (see Diagram 1).
Set Switch to
Remote
Diagram 1
2. Press and release the ON/OFF button on the remote handheld transmit-
ter (see Diagram 2). An audible beep should be heard from the receiver.
The system will need to be reset as follows:
a) Turn the system off using ON/OFF switch or press ON/OFF button - if
using optional remote.
b) After approximately 2 seconds turn on ON/OFF switch or press ON/OFF
button if using optional remote.
c) Repeat step 2.
SHUTDOWN PROCEDURE
1. Turn the wall mounted switch or remote to the "OFF" position.
2. Press "OFF" on the remote control.
3. Turn the gas control knob to the "OFF" position to turn off the pilot.
ON/OFF
Button
Remote shown in Manual Mode on Hi
Diagram 2
54 | Regency Bellavista™ B41XTE -10 Gas Fireplace
|
COPY OF LIGHTING PLATE INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
This appliance must be installed in accordance with local codes, if any;
if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or
WARNING: If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury or loss of life. Improper installation, adjustment,
alteration, service or maintenance can cause injury or property damage. Refer to the owner’s
information manual provided with this appliance. For assistance or additional information
consult a qualified installer, service agency or gas supplier.
AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice
risquede déclencher un incendie ou une explosion entraînant des dommages, des blessures ou
la mort.
Une installation, d'ajustement, de modifi cation, de service ou d'entretien peut provoquer
des blessures ou des dommages matériels. Reportez-vous au manuel du propriétaire de
l'information fournie avec cet appareil. Pour obtenir de l'aide ou des informations supplémentaires consulter un installateur qualifi é, une agence de service ou fournisseur de gaz.
A) This appliance is equipped with an ignition device which automatically lights the pilot.
Do not try to light the pilot by hand.
B) BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the fl oor
because some gas is heavier than air and will settle on the fl oor.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electric switch, do not use any phone in your building.
- Immediately call your gas supplier from a neighbours phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fi re department.
C) Do not use this appliance if any part has been under water. Immediately call a qualifi ed service
technician to inspect the appliance and replace any part of the control system and any
gas control which has been underwater.
A) Cet appareil est muni d’un dispositif d’allumage qui allume automatiquement la veilleuse.
Ne tentez pas d’allumer la veilleuse manuellement.
B) AVANT DE FAIRE FONCTIONNER, renifl ez tout autour de l’appareil pour déceler une odeur
de gaz. Renifl ez près du plancher, car certains gaz sont pluslourds que l’air et peuvent
s’accumuler au niveau du sol.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d’allumer d’appareil
• Ne touchez à aucun interrupteur; ne pas vous servir des téléphones se trouvant dans le
bâtiment.
• Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les
instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur, appelez le service des incendies
C) N’utilisez pas cet appareil s’il a été plongé dansl’eau, même partiellement. Faites inspecter l’appareil par un tech-
nicien qualifi é et remplacez toute partie du système de contrôle et toute commande qui ont été plongés dans l’eau.
CAUTION: Hot while in operation. Do not touch. Severe Burns may result. Due to high surface
temperatures keep children, clothing and furniture, gasoline and other liquids having fl ammable
vapors away. Keep burner and control compartment clean. See installation and operating
instructions accompanying appliance.
1) Ensure the wall switch/receiver is in the remote position.
2) Press and release the ON/OFF button on the remote handheld transmitter. An audible beep should be
heard from the receiver.
3) After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner.
4) The unit will turn on.
Note: The fi rst attempt to ignition will last approximately 60 seconds. If there is no fl ame ignition (rectifi cation) the board will stop sparking for approximately 35 seconds. After this wait time, the board will start a
second try for ignition by sparking for approximately 60 seconds. If there is still no positive ignition after the
second attempt the board will go into lock out.
The system will need to be reset as follows (after going into lock out mode):
a) Wa it 5 minutes - turn the system off using ON/OFF switch or press ON/OFF button if using
b) After approximately 2 seconds turn on ON/OFF switch or press ON/OFF button if using remote.
c) Unit will repeat step 2.
1) S’assurer que l’interrupteur mural/récepteur soit en position télécommande.
2) Appuyer sur la touche ON/OFF de la télécommande et relâcher. Un bip sonore se fera entendre depuis le
récepteur
3) Après environ 4 secondes, le système d'allumage des étincelles pendant 60 secondes pour allumer le
brûleur principal.
4) Les fl ammes s’allumeront.
Remarque : Au premier allumage, le système tente d’allumer les fl ammes pendant 60 secondes. Si l’essai
est infructueux, le système fait une pause de 35 secondes. C’est ce qu'on appelle l'étape de rectifi cation.
Ce délai écoulé, le système tente à nouveau d'allumer les fl ammes en produisant des étincelles pendant 60
secondes. Si les fl ammes ne s’allument toujours pas, le système se met en mode verrouillage.
Il faut alors le réinitialiser en suivant les étapes ci-dessous (pour le déverrouiller) :
a) Attendre 5 minutes et éteindre l’appareil en réglant l’interrupteur à la position « OFF »;
b) Attendre 2 secondes et rallumer le système à l’aide de l’interrupteur ou de la télécommande.
c) L'unité répétera l'étape 2.
1) Turn the wall mounted switch or remote to the "OFF" position.
2) If service is to be performed–you must disconnect power and shut off gas to the unit.
Utilisez l'interrupteur murale ON/OFF du Brûleur ou du contrôle à distance pour éteindre le brûleur.
1)
2) Si le service est effectuée–vous devez débrancher l'alimentation et coupez le gaz à l'unité.
remote
DO NOT REMOVE THIS INSTRUCTION PLATE
Natural Gas and Propane Installation Codes, CSA B149.1.
LIGHTING INSTRUCTIONS
TO TURN OFF GAS APPLIANCE
919-401a
operating instructions
55
Regency Bellavista™ B41XTE -10 Gas Fireplace | 55
56
|
maintenance
MAINTENANCE
INSTRUCTIONS
1) Always turn off the gas valve before cleaning.
For relighting, refer to lighting instructions.
Keep the burner and control compartment
clean by brushing and vacuuming at least
once a year. When cleaning the logs, use a
soft clean paint brush as the logs are fragile
and easily damaged.
position and condition. Visually check the
ame of the burner periodically, making sure
the ames are steady; not lifting or oating.
If there is a problem, call a qualied service
person.
5) The appliance and venting system must be
inspected before use, and at least annually,
by a qualied eld service person, to ensure
that the ow of combustion and ventilation
air is not obstructed.
Note: Never operate the appliance without
the glass properly secured in place.
6) Do not use this appliance if any part has been
under water. Immediately call a qualied
service technician to inspect the appliance
and to replace any part of the control system
and any gas control which has been under
water.
®
uses StoveBright
3) Check for evidences of excessive
condensation, such as water droplets forming
in the inner liner, and subsequently dripping
out the joints, Continuous condensation can
cause corrosion of caps, pipe, and ttings.
It may be caused by having excessive
lateral runs, too many elbows, and exterior
portions of the system being exposed to
cold weather.
4) Inspect joints, to verify that no pipe
sections or ttings have been disturbed,
and consequently loosened. Also check
mechanical supports such as Wall Straps,
or plumbers' tape for rigidity.
LOG REPLACEMENT
The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door and carefully remove the
logs. (The pilot light generates enough heat to
burn someone.) If for any reason a log should
need replacement, you must use the proper
replacement log. The position of these logs
must be as shown in the diagrams under Log
Installation.
Note: Improper positioning of logs may
create carbon build-up and will
severely alter the unit's performance
which is not covered under
warranty.
GLASS GASKET
If the glass gasket requires replacement use a
tadpole glass gasket (Part # 936-155).
DOOR GLASS
Your Regency® replace is supplied with high
temperature 5mm-Ceramic glass. If your glass
requires cleaning, we recommend using an
approved glass cleaner available at all authorized
dealers. Do not use abrasive materials.
CAUTION & WARNINGS:
* Do not clean when the glass is hot.
* The use of substitute glass will void all
product warranties.
* Care must be taken to avoid breakage of
the glass.
* Do not strike or abuse the glass.
* Do not operate this replace without the
glass front or with a cracked or broken
glass front.
* Wear gloves when removing damaged or
broken glass.
* Replacement of the glass panels should be
done by a licensed or qualied service per
son.
GLASS REPLACEMENT
In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency dealer only. Replacement glass (Part
#940-362/P) is shipped already installed into
the door frame. Reinstall as per Glass Door
Installation in the "Glass Door Removal" section.
7) In the event this appliance has been serviced
check that the vent-air system has been
properly resealed & reinstalled in accordance
with the manufacturer's instructions.
8) Verify operation after servicing.
General Vent Maintenance
Conduct an inspection of the venting system
semi-annually. Recommended areas to inspect
as follows:
1) Check the Venting System for corrosion in
areas that are exposed to the elements. These
will appear as rust spots or streaks, and in
extreme cases, holes. These components
should be replaced immediately.
2) Remove the Cap, and shine a ashlight down
the Vent. Remove any bird nests, or other
foreign material.
56 | Regency Bellavista™ B41XTE -10 Gas Fireplace
|
B41XT
BULB REPLACEMENT
ACCENT LIGHT BULB REPLACEMENT
maintenance
57
1) Shut off electrical supply.
2) Remove Full Screen Door and bottom Louver if installed.
3) Remove the glass door - see instructions in manual.
4) Remove the logs, lava rock and vermiculite if installed.
5) Remove the brick or inner panels if installed - see instructions in manual.
6) Remove the burner and rear log tray - see below.
Diagram 1: Remove the left and right screws.
7) Slide the burner assembly to the right to release it from the orifi ce,
then lift it out.
9) Remove the 2 screws securing the base tray - lift base tray up and
out. Diagram 4a and 4b.
Diagram 4a
Diagram 4b
10) Replace the bulbs as necessary.
Note: Oils from hands will shorten the life of the bulbs,
do not handle bulbs with bare hands.
Base Tray
Diagram 2: Slide burner assembly to the right
and then remove.
8) Remove the 2 screws securing the rear log tray and lift out. Diagram 3
Diagram 3
Regency Bellavista™ B41XTE -10 Gas Fireplace | 57
11) Reverse steps 9 - 1.
58
|
maintenance
VALVE REPLACEMENT
1) Shut off the gas and electrical supply.
2) Remove the mesh barrier.
3) Open the ush door and remove the door.
4) Remove the logs.
5) Remove the burner/grate assembly by
removing the 2 screws.
Diagram 1: Remove the left and right screws.
6) Slide the burner assembly to the right to
release it from the orice, then lift it out.
8) Remove the 2 screws securing the burner
tray - lift burner tray up and out. Diagram
4a and 4b.
Diagram 4a
Diagram 4b
9) Disconnect the inlet gas line. See Diagram
5.
INSTALLING VALVE
1) Place new valve tray and gasket into position.
2) Reinstall the 14 hold down screws.
3) Connect the EV1, EV2 and ground wires to
the appropriate connections on the valve.
4) Reinstall the rear log tray.
5) Install burner/grate assembly
6) Hook up the gas line and check for gas leaks
with a soap and water solution or a gas leak
detector. (Do not use open ame for leak
testing.)
7) Fire up the unit temporarily
8) Check the manifold pressure.
9) Reinstall the logs and brick panels as
needed.
10) Reinstall the door and replace the louvers.
11) Fire up the unit again and check for proper
ame appearance and glow on logs.
Diagram 2: Slide burner assembly to the right
and then remove.
7) Remove the 2 screws securing the rear log
tray and lift out. Diagram 3
Diagram 3
Diagram 5
10) Disconnect the EV1, EV2, and ground wires
from the valve - as shown below.
Ground
EV1EV2
11) Remove the 14 screws securing the
valve tray assembly in place (Diagram
7) and then lift the entire assembly out
Also remove the valve gasket.
506-003 Valve Assembly Gasket
911-012 Ignition Board (DBC)
911-013 Wiring Harness -Switch
911-127 Battery Compartment Door (Receiver)
911-018 Battery Holder
911-038 Flame Electrode
911-039 Pilot Hood
910-432 Pilot Tube
910-572 Remote Recevier
911-032 Wiring Harness (Remote)
910-592 Remote Control GTMF hand held
911-030 Fan Control Module
910-100 Pilot Orice - NG
910-101 Pilot Orice - LP
946-721 AC Adaptor
578-972 Conversion Kit LP
15) 506-062 Base Tray
506-930 Log Set
15
1
4
10
12
9
7
11
8
6
60 | Regency Bellavista™ B41XTE -10 Gas Fireplace
|
1
5
4
ACCESSORIES
Part # Description
1) 509-946 3-Sided Finishing Trim
4) 506-901 Brick Panels - Standard Brown
506-902 Brick Panels - Standard Red
506-905 Brick Panels - Standard Charcoal Gray
5) 506-908 Inner Panels - Black Enamel
parts list
61
Regency Bellavista™ B41XTE -10 Gas Fireplace | 61
62
|
notes
62 | Regency Bellavista™ B41XTE -10 Gas Fireplace
|
Regency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly
before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency® Product.
This warranty is not transferable.
The Warranty: Limited Lifetime
The combustion chamber, heat exchanger, burner tubes/pans, logs, brick panels and gold plating (against defective manufacture only) are covered under the Limited Lifetime
Warranty for ve (5) years for parts and subsidized labour* and parts only thereafter.
Glass is covered for lifetime against thermal breakage only, parts and subsidized labour* for ve (5) years and parts only thereafter from date of purchase.
External casting, surrounds and grills are covered against cracks and warps resulting from manufacturer defects, parts and subsidized labour* for three (3) years from the date of
purchase and parts only thereafter.
Special Finishes - One year on brushed nickel and antique copper full screens and doors. You can expect some changes in color as the product "ages" with constant heating and
cooling. FPI warranties the product for any manufacturing defects on the original product. However, the manufacturers warranty does not cover changing colors and marks, ie.
nger prints, etc applied after the purchase of the product. Damage from the use of abrasive cleaners is not covered by warranty.
Electrical and mechanical components such as blowers, switches, wiring, thermodiscs, FPI remote controls, spill switches, thermopiles, thermocouples, pilot assembly components,
and gas valves are covered for two years parts and one year subsidized labour* from the date of purchase. Blowers and valves replaced under warranty are considered repairs and
continue as if new with appliance. ie. twelve (12) months from original purchase date of appliance with a minimum of three (3) months coverage from date of replacement.
FPI venting components are covered parts and subsidized labour* for three (3) years from date of purchase.
Simpson Dura-Vent venting components (Direct Vent units) are covered by Simpson Dura-Vent Inc. warranty.
Repair/replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit will carry a 90 day warranty, valid with a receipt only. Any item
shown to be defective will be repaired or replaced at our discretion. No labor coverage is included with these parts.
Conditions:
Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI's option, through an accredited distributor or agent provided
that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.
Porcelain/Enamel - Absolute perfection is either guaranteed nor commercially possible. Any chips must be reported and inspected by an authorized dealer within three days of
installation. Reported damage after this time will be subject to rejection.
It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for
manufacturer defect.
®
The authorized selling dealer is responsible for all in-eld service work carried out on your Regency
unauthorized service persons or dealers.
At all times FPI reserves the right to inspect product in the eld which is claimed to be defective.
All claims must be submitted to FPI by authorized selling dealers. It is essential that all submitted claims provide all of the necessary information including customer name, purchase
date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.
Exclusions:
This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim.
At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufactured.
ie. as products evolve, eld modications or upgrades will not be performed.
FPI will not be liable for travel costs for service work.
Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the terms of this warranty policy.
Embers, rockwool, gaskets, door handles and paint are not covered under the terms of this warranty policy.
Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.
The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject to misuse, improper installation, negligence
or accident, spillage or downdrafts caused by environmental or geographical conditions, inadequate ventilation, excessive offsets, negative air pressure caused by mechanical
systems such as furnaces, fans, clothes dryer, etc.
Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.
FPI will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.
Performance problems due to operator error will not be covered by this warranty policy.
Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from FPI, may nullify your warranty on
this product.
Any alteration to the unit which causes sooting or carboning that results in damage to the interior / exterior facia is not the responsibility of FPI.
* Subsidy according to job scale as predetermined by FPI.
product. FPI will not be liable for results or costs of workmanship from
warranty
63
Regency Bellavista™ B41XTE -10 Gas Fireplace | 63