Redring Professional SB Installation & Operating Instructions Manual

12
(A3 Leaflet No. 571-2287-01c)
Morley Way, Peterborough, PE2 9JJ, UK
Telephone: +44 (0) 844 372 7761 / Fax: +44 (0) 84 372 7762
Website: www.applied-energy.com
Technical Advisory Service Hotline: +44 (0) 844 372 7766
THE
BOILING WATER DISPENSER
INSTALLATION & OPERATING INSTRUCTIONS
IMPORTANT:
This booklet should be left with the user after
installation and demonstration
2
Contents
Installation Instructions Page
Important notes - installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
What the installer will need . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Where to locate the unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installing the water supply and steam vent pipes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installing the mains supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Removing the front cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Model range and unit performance details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Unit schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Fixing the unit on the wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Connecting the water supply and steam vent pipes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Connecting the mains cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Replacing the front cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Operating Instructions
General product description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
How to operate the unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
How to maintain and descale your unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Trouble shooting guidance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
After Sales Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Important notes – PAT testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Guarantee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Thank you for choosing a quality Redring product from Applied Energy Products Limited, Peterborough, U.K
General Product Description
The “SB Professional Range” are wall mounted, self-calibrating and self-filling boiling wa
ter heaters.
They can be used for making cups of tea or coffee and even soups and hot snacks.
A special condenser traps steam and returns droplets to the tank, minimising waste and saving energy.
The water temperature is set at approximately 95°C (dependent on unit volume) and automatically maintained by the unit.
Pulling the front lever forward dispenses hot water.
11
Important Notes
The heater level detection system uses two protective resistors to earth, this results in an insulation resistance (IR) of 0.5M, and as a consequence the equipment would appear to fail a routine Portable Appliance Test (PAT).
This is only relevant if the unit is fitted with a standard 13A plug, however, this product is not to be classed as a portable appliance, and as detailed on page 3, it is instructed that the unit is to be wired
to a means for disconnecting the fixed wiring in all poles in accordance with the wiring rules
(eg. 13A fused double pole isolating switch). In the unlikely event that the unit is fitted incorrectly, the recommendation is if test is carried out with
water in the tank the IR reading will be 0.5M Ω. If this becomes an issue to the PAT engineer, switch off the power and drain the tank through the tap prior to connection test.
PAT test is not a case of pass/fail. If PAT records negative then this is not a failure. It highlights the possibility of a failure and then the unit should undergo further investigation.
With regards to BS EN 60335-1 Clause 16 earth leakage (not IR) can be 0.7A per kW = 1.8mA. Test at 254V (6% above nominal) / 1.8Ma = 141k so reading of 0.5M is acceptable.
After Sales Service
We offer a technical advisory service on the telephone to contractors and other customers with problems in the field.
RING 0844 372 7766
Spare parts can be supplied against Credit or Debit cards.
RING 0844 372 7750
Remember to quote the exact model of unit, as written on the front of the unit and on this leaflet. It may also be of use to have a note of the model and serial number as stated on the underside of the unit.
This appliance is not intended for use by persons (including children and the infirm) with
reduced physical,
sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Loading...