Redring 1070800E, 1070820E, 1070830E, 1070815E, 1070810E User Manual

...
Page 1 of 8
Trouble Shooting
All Models
Redring SB
Redring SB Professional
On Wall Boiling Water Heater
Models:
Contents
Subject Page
General Product Operation......................................................................2
Spares Diagram and List.........................................................................3
Unit Dimensions.......................................................................................3
Problem Solving......................................................................................4
Tank Access............................................................................................5
Parts Replacement Guide.......................................................................5 - 6
Intentionally Blank..................................................................................7
AEP Address............................................................................................8
Page 2 of 8
Redring SB
The General Operational Process
1. After fixing to wall and checking all connections, turn on power and water together.
2.The solenoid valve will now open and fill the tank until it reaches the low water level sensor.
3. When the low water level sensor is contacted, the filling process stops and the heating cycle starts, the heating will continue until the water reaches approximately 98-99ºC.
4. Once this temperature is reached the heating stops and filling restarts, this process of heat/fill/heat/fill continues until the top water level sensor is reached. When water makes contact with the high water level sensor, the PCB isolates the filling cycle from this function, and the element controlled by the PCB remains in circuit to monitor for any heat top up’s that may be required.
5. If any subsequent water is used and the unit drops away from the high level water sensor, the heat/fill/heat /fill process restarts until water is back at the high level water sensor and at maximum temperature.
Page 3 of 8
OVERSINK BOILING
Ref Part No Description
1 1311010 Water Solenoid Valve 2 1311044 Condenser Assembly 3 Cold Water Inlet To Tank 4 1311043 Thermistor Steam Sensor 5a Element & Tank Assembly 5b 1311032 Element Assembly 5 to 25 Litre
6 1311006 Manual Rest Thermostat (boil dry protection)
7 Steam Vent Outlet (half inch BSP)
8 1311022 Auto Reset Thermostat (steam vent overflow)
9a Water Outlet Fitting (half inch BSP)
2
5a
1
9a
7
13
1
3
6
8
10
12
14
17
16
18
30mm
85mm
65mm
45mm
15a & 15b
11
7
4
5b
Teflon Tape
Reducer 1/2” BSP (Olive Compression Union)
FRONT VIEW
SIDE VIEW
55mm
9b
Spare Parts
9b 1311056 Tap Assembly
10 1311082 Sensor (minimum water level)
11 1311048 Probe (maximum water level)
12 Steam Vent Outlet
13 Maximum Water Level
14 1310842 Power Cord & Plug Assembly
15a 1311045 Control Board Assembly (2.5 Litre)
15b 1311042 Control Board Assembly (5 to 25 Litre)
16 1311058 Tap Cup Seal
17 1311060 Tap Insert
18 1310732 Tap Spring
399.0
621.8
609.45
42.45
41.4
41.4
481.8
143.4
199.50
199.50
41.4
278.0
41.4
360.8
500.8
488.45
42.45
143.4
2.5L 5-75L 10-15L 20-25L
A 56.4 41.4 41.4 41.4
B 198.0 278.0 335.0 399.0
C 418.45 488.45 545.45 609.45 D 42.45 42.45 42.45 42.45
E 143.4 143.4 143.4 143.4
F 200
H 430.8 500.8 557.8 621.8
W 310.8 360.8 417.8 481.8
Wall Mounting Dimmensions (mm)
2.5- 15L
20-25L
Spare parts and diagrams for location and installation dimensions.
Redring SB
AA
41.441.4
42.4542.45
DD
EE
143.4143.4
WW
360.8360.8
BB
278.0278.0
AA
41.441.4
AA
41.441.4
WW
481.8481.8
BB
399.0399.0
FF FF
199.50199.50
199.50199.50
AA
41.441.4
500.8500.8
HH
CC
488.45488.45
621.8621.8
HH
CC
609.45609.45
42.4542.45
DD
EE
143.4143.4
Loading...