Red Lion XCRS User Manual

Bulletin No. XCRS- A Drawing No. LP0669 Released 01/10
Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net
MODEL XCRS - RS232/485 OPTION CARD FOR DATA STATION PLUS AND MODULAR CONTROLLER
CONFIGURED USING CRIMSON SOFTWARE
(VERSION 2.0 OR LATER)
ISOLATED RS232 AND RS485 MULTIPLEXED PORTS CAPABLE
OF COMMUNICATING WITH RS232, RS422, RS485 AND DH485 DEVICES AT UP TO 115,200 BAUD
EASY INSTALLATION
GENERAL DESCRIPTION
The XCRS option card adds an additional RS232 and RS422/485 port to the series. This isolated card protects user equipment from potentially harmful ground loops while providing high-speed RS232, RS422, RS485, and DH485 communication options to the end user.
The XCRS communication card is easily installed by removing the blank expansion port cover of your Modular Controller or Data Station Plus, and plugging the XCRS card into the expansion port. Configuration is simple using Red Lion's free Crimson 2.0 software.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the literature or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
Do not use the controller to directly command motors, valves, or other actuators not equipped with safeguards. To do so can be potentially harmful to persons or equipment in the event of a fault to the controller.
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
CONTENTS OF PACKAGE
- XCRS option card
- This hardware bulletin
ORDERING INFORMATION
MODEL NO. DESCRIPTION PART NUMBER
XCRS
CBL
DR SFCRM2 Crimson 2.0 with G3/Data Station Manual SFCRM2 Crimson 2.0 with Modular Controller Manual 3SFCRM2MC
1
Contact your Red Lion distributor or visit www.redlion.net for complete
selection.
2
Red Lion offers RJ modular jack adapters. Refer to DR literature for
complete details.
3
Use these part numbers to purchase Crimson 2.0 on CD with a printed
RS232/485 option card for Modular Controller or Data Station Plus
Communication Cables DIN Rail Mountable Adapter Products
1
2
3
XCRS0000
CBLxxxxx DRxxxxxx
SFCRM200
manual, USB cable and RS-232 cable. Otherwise, download free of charge from www.redlion.net.
SPECIFICATIONS
1. POWER REQUIREMENTS: 24 V @ 50 mA max. Power is supplied to the
option card from the main board of the Modular Controller Master or Data Station Plus.
2. COMMUNICATIONS: Serial Ports: Format and Baud Rates for each port are individually software programmable up to 115,200 baud and are isolated to help prevent ground loops. The RS422/485 and DH485 port via RJ45 and the RS232 port via RJ12 share the same hardware. The XCRS option card multiplexes the ports to communicate via two protocols. These ports may be used to configure different master protocols, but only one port may be used if configuring a slave protocol or AB DH485.
DH485 TXEN: Transmit enable; open collector , VOH = 15 VDC, VOL = 0.5 VDC Isolation from XCRS Communication ports to the Modular Controller Master or Data Station Plus: 1000 VDC for 1 minute.
3. CERTIFICA TIONS AND COMPLIANCES: Refer to main unit manual or “Agency Approvals” section of Red Lion’s
website for agency certifications.
ELECTROMAGNETIC COMPATIBILITY
Emissions and Immunity to EN 61326: Electrical Equipment for Measurement,
Control and Laboratory use.
Reference Modular Controller Master or Data Station Plus unit for EMC
specifications
1
4. ENVIRONMENTAL CONDITIONS:
+
-
ISOLATING
DC : DC
A
RS422
PORT
PORT
RS232
B
B
RS485/
Refer to the specifications of the Modular Controller Master or Data Station
Plus you are installing this card in.
5. CONSTRUCTION: For indoor use only. Installation Category II, Pollution
Degree 2.
6. INSTALLATION REQUIREMENTS: See “Installing the XCRS Option
card” for more details.
7. WEIGHT: 1.9 oz (53.9 g)
BLOCK DIAGRAM
INSTALLING THE XCRS OPTION CARD
1. Remove power from the unit
2. Insert a flat-bladed screwdriver into the slot at the top of the expansion port cover. Gently apply pressure on the screwdriver in an upward direction until the expansion port cover disengages from the unit as shown in Figure 1.
3. Verify that the option card knobs are in the “unlocked” position as shown in Figure 2.
4. Carefully insert the option card into the expansion port opening while aligning the card-edge connector on the option card with the main board's header, as shown in Figure 3. Once aligned, gently press on the front of the card until it is flush with the front of the case.
5. Turn the option card knobs to the locked position as shown in Figure 4.
Figure 1
Caution: The expansion and main circuit boards contain static
sensitive components. Before handling the cards, discharge static charges from your body by touching a grounded bare metal object. Ideally, handle the cards at a static controlled clean workstation. Also, handle the cards by the edges only. Dirt, oil, or other contaminants that may contact the cards can adversely affect circuit operation.
Warning: Risk of Danger: Be sure to remove all power before
removing the expansion port cover.
XCRS
RX
TX
RS485
RS232
Figure 2
XCRS
RX
TX
RS485
RS232
XCRS
Figure 3
RX
TX
RS485
RS232
Figure 4
2