Red Lion PSC User Manual

Tel +1 (717) 767-6511
C
US LISTED
U
L
R
51EB
IND. CONT. EQ.
Fax +1 (717) 764-0839
www.redlion.net
MODEL PSC - PROCESS SETPOINT CONTROLLER
AUTOMATIC PROGRAM DELAY FOR PROFILE CONFORMITY,
PLUS PROGRAM LINKING, REPEATING AND AUTO POWER-ON FUNCTIONS FOR ENHANCED CAPABILITY
DUAL EVENT OUTPUTS FOR TIMED ACTIVATION OF PROCESS
EQUIPMENT SUCH AS STIRRERS, FANS, HEATERS, ETC. (Uses Alarm Output Channels)
FOUR SETPOINT & PID PARAMETER SETS FOR QUICK RECALL
OF SETPOINTS AND/OR GAIN VALUES DURING BATCH OR PROCESS CHANGEOVER
PROGRAMMABLE USER INPUT FOR CONTROLLER AND
SETPOINT PROGRAM CONTROL
100 MSEC SAMPLING PERIOD WITH 0.15% ACCURACY
ON DEMAND AUTO-TUNING OF PID CONTROL SETTINGS
DUAL LED DISPLAYS FOR SIMULTANEOUS INDICATION OF
PROCESS AND SETPOINT OR PROCESS AND PROFILE STATUS
ACCEPTS EITHER 0 to 10 VDC OR 4 to 20 mA DC INPUT SIGNAL
FIELD REPLACEABLE AND INTERCHANGEABLE OUTPUT
MODULES (Relay, Logic/SSR drive, and Triac)
SETPOINT PROGRAM CONTROLLER FOR TIME VS. PROCESS
(RAMP/SOAK) AND SPECIAL BATCH/RECIPE APPLICATIONS
ADVANCED PROGRAM PROFILING IN A 1/8 DIN PACKAGE
ON-LINE MONITORING AND CONTROL OF PROGRAM STATUS,
TIME, AND SETPOINT VALUE (Profile Run, Pause, Stop, Advance, Modify Time, & Setpoint Value)
OPTIONAL DUAL ALARM OUTPUTS (Uses Output Modules)
OPTIONAL SECONDARY OUTPUT (Uses Output Module)
OPTIONAL LINEAR 4 to 20 mA OR 0 to 10 VDC OUTPUT FOR
CONTROL OR PROCESS RE-TRANSMISSION
OPTIONAL RS485 SERIAL COMMUNICATIONS INTERFACE
OPTIONAL TYPE 4X/IP65 SEALED FRONT BEZEL
Bulletin No. PSC-C
Drawing No. LP0315
Released 08/13
DESCRIPTION
The PSC is a setpoint controller suitable for time vs. process control applications. The PSC Controller accepts either a 0 to 10 VDC or a 4 to 20 mA DC input signal, precisely scales the process signal, according to programmable scaling points, and provides an accurate output control signal (time proportional or linear) to maintain a process at the desired control point. A comprehensive set of easy to use steps allows the controller to satisfy various applications. The user input can be programmed to perform a variety of controller functions.
Dual 4-digit displays allow viewing of the measured process value and setpoint or the process and profile status simultaneously. Front panel indicators inform the operator of controller status and output states. Replaceable output modules (Relay, logic/SSR drive or Triac) can be fitted to the main control output, alarm output(s) or timed event output(s), and secondary output.
The PSC has been designed to simplify the set-up and operation of a controlled setpoint profile program. The setpoint program is easily entered and controlled through the front panel. Full display capabilities keep the operator informed of the process value, profile status, output states, and setpoint value.
DIMENSIONS In inches (mm)
Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 5.5" (140) H x 2.1" (53.4) W.
(137.4)
%PW
MAN
AL1
PGM
OP1
DSP
PAR
AL2
(96.5)
The controller can operate in the standard PID control mode for both Output 1 and Output 2 with on-demand auto-tune which establishes the PID gain set. The PID gain set can be fine tuned by the operator at any time or may be locked from further modification. The unit can be transferred to the manual control mode providing the operator with direct control of the output.
The PSC features four programs or profile recipes, each with up to eight ramp/soak segments, which can be easily stored and executed at any time. Longer profiles can be achieved by linking one or more profiles together, creating a single profile of up to 32 ramp/soak segments. Process profile conformity is assured during either soak (hold) phases or both ramp and hold phases by an adjustable error band parameter. The program repeat function cycles the profile either continuously or a set number of times. Power-on options automatically re-start, stop, or resume a running profile. The profile can be controlled via the front panel buttons, the user input, or the optional serial communications port.
PANEL CUT-OUT
+.02
-.00
+.6
(45 )
-.0
+.03
(91.4)
-.00
+.8
-.0
(49.5)
.40
(10.2)
(134.4)
(44.4)
1
DESCRIPTION (Cont’d)
Four control points, each having a setpoint and PID parameter set, are available for instant front panel implementation during batch changeover, or other process conditions. A control point may have its PID gain set values disabled when implementing the control point.
The optional RS485 multidrop serial communications interface provides the capability of two-way communication between a PSC unit and other compatible equipment such as a printer, a programmable controller, or a host computer. In multipoint applications the address number of each unit on the line can be programmed from 0 to 99. Up to thirty-two units can be installed on a single pair of wires. The Setpoint value, % Output Power, Setpoint Ramp Rate, etc. can be interrogated or changed by sending the proper command code via serial communications. Alarm output(s) may also be reset via the serial communications interface option.
Optional alarm output(s) may be configured to operate as a timed event output or as a standard alarm output. As an alarm output it may be configured to activate according to a variety of actions (Absolute HI or LO, Deviation HI or LO, or Band IN or OUT) with adjustable hysteresis. Also, a standby feature suppresses the output(s) on power-up until the process stabilizes outside the alarm region. Timed event output(s) allow the controller to activate other equipment while a programmed profile is running. Each profile can define up to 16 event states (phases), for each output(s).
An optional secondary output is available for processes that require cooling which provides increased control accuracy and response.
The optional linear 4 to 20 mA or 0 to 10 VDC output signal is available to interface with final actuators, chart recorders, indicators, or other controllers. The output signal can be digitally scaled and selected to transmit one of the following:
% Output Power Measurement Value Measurement Value Deviation Setpoint Value
An optional Type 4X/IP65 rated bezel is available for washdown and/or dirty environments, when properly installed. Modern surface-mount technology, extensive testing, plus high immunity to noise interference, makes the controller extremely reliable in industrial environments.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
Do not use the PSC to directly command motors, valves, or other actuators not equipped with safeguards. To do so, can be potentially harmful to persons or equipment in the event of a fault to the unit. An independent and redundant process limit indicator with alarm outputs is strongly recommended. The indicators should have input sensors and AC power feeds independent from other equipment.
SPECIFICATIONS
1. DISPLAY: Dual 4-digit
Upper Process Display: 0.4" (10.2 mm) Red LED
Lower Auxiliary Display: 0.3" (7.6 mm) Green LED
Display Messages:
“OLOL” - Appears when measurement exceeds +105% of input range. “ULUL” - Appears when measurement exceeds -5% of input range. “SENS” - Appears when measurement exceeds “OLOL” & “ULUL” range.
“....” - Appears when display value exceeds + display range.
“-...” - Appears when display value exceeds - display range.
2. POWER: Switch selectable 115/230 VAC (+10%, -15%) no observable line
variation effect, 48 to 62 Hz, 10 VA.
3. ANNUNCIATORS:
6 LED Backlight Status Indicators:
%PW - Lower auxiliary display shows power output in (%). PGM - Lower auxiliary display shows profile status or profile time remaining. MAN - Controller is in manual mode. OP1 - Main control output is active. AL1 - Alarm #1 is active. AL2 - Alarm #2 is active (for Dual Alarm Option). OP2 - Secondary output is active (for Secondary Option).
4. CONTROLS: Four front panel push buttons for modifying and setup of
controller functions and one external input.
5. SETPOINT PROFILE:
Profiles: 4
Segments Per Profile: 8 ramp/hold segments (linkable to 32 segments).
Ramp Rate: 0.1 to 999.9 units/minute or no ramp.
Hold Time: Off or from 0.1 to 999.9 minutes, can be extended to 500 hours
by linking.
Error Band Conformity: Off or from 1 to 9999 units deviation, + value for
hold phases, - value for both ramp and hold phases.
Power-On Modes: Stop, auto-start, or profile resume. Start Mode: Ramps from process value. Program Auto Cycle: 1 to 249, or continuous. Event Outputs: 2, time activated with profile [uses Alarm output(s)]. Control: Front panel buttons, user input, or RS485 communications.
6. CONTROL POINTS: Setpoints: 4 PID gain sets: 4 Control: Front panel buttons or user input.
7. SIGNAL INPUT: Sample Period: 100 msec Response Time: 300 msec (to within 99% of final value w/step input). Signal Overdrive Threshold:
10 V Range: 13 V 20 mA Range: 26 mA
Signal Overdrive Response:
Main Control Output: Programmable preset output. Display: “SENS” DC Linear: Programmable preset output. Normal Mode Rejection: 40 db @ 50/60 Hz (improves with increased
digital filtering).
Common Mode Rejection: 100 db, DC to 50/60 Hz.
8. RANGE AND ACCURACY:
Signal Range
0 to 10 VDC ±(0.15% + 3 mV) 300 VDC 1M 10 mV
0 to 20 mADC ±(0.15% + 6 µA) 200 mADC 10 10 µA
Accuracy (% of
Unscaled Reading)
Max. Input
Input
Impedance
Resolution
9. OUTPUT MODULES (For All Output Channels): (Optional - Must be ordered separately)
Relay:
Type: Form-C (Form-A with RS485 option) Rating: 5 Amps @ 120/240 VAC or 28 VDC (resistive load), 1/8 HP @
120 VAC (inductive load).
Life Expectancy: 100,000 cycles at max. rating. (Decreasing load and/or
increasing cycle time, increases life expectancy).
Logic/SSR Drive: Can drive multiple SSR Power Units.
Type: Non-isolated switched DC, 12 VDC typical Drive: 45 mA max.
Triac:
Type: Isolated, Zero Crossing Detection. Ratings: Voltage: 120/240 VAC
Max Load Current: 1 AMP @ 35°C
0.75 AMP @ 50°C
Min Load Current: 10 mA Off State Leakage Current: 7 mA max. @ 60 Hz Operating Frequency: 20 to 500 Hz Protection: Internal Transient Snubber, Fused.
10. MAIN CONTROL OUTPUT: Control: PID or ON/OFF. Output: Time proportioning or linear DC. Hardware: Plug-in, replaceable output modules. Cycle time: Programmable. Auto-tune: When performed, sets proportional band, integral time, and
derivative time values.
Probe Break Action: Programmable.
11. SECONDARY OUTPUT (Optional):
Control: PID or ON/OFF. Output: Time proportioning or linear DC Hardware: Plug-in, replaceable output modules. Cycle time: Programmable. Proportional Gain Adjust: Programmable. DeadBand Overlap: Programmable.
12. LINEAR DC DRIVE (Optional): With digital scale and offset, programmable deadband and update time.
4 to 20 mA:
Resolution: 1 part in 3500 typ. Accuracy: ±(0.1% of reading + 25 µA). Compliance: 10 V (500 max. loop impedance).
0 to 10 VDC:
Resolution: 1 part in 3500 typ. Accuracy: ±(0.1% of reading + 35 mV). Min. Load Resistance: 10 K (1 mA max.)
Source: % output power, setpoint, deviation, or process value.
(Available for OP1 or OP2, but not both.)
2
SPECIFICATIONS (Cont’d)
13. ALARMS (Optional): Hardware: Plug-in, replaceable output module. Modes: Absolute high acting
Absolute low acting Deviation high acting Deviation low acting Inside band acting Outside band acting Timed event output(s)
Reset Action: Programmable; automatic or latched. Delay: Programmable; enable or disable. Hysteresis: Programmable. Annunciator: LED backlight for “AL1”, “AL2”, (Alarm #2 not available
with secondary output).
14. SERIAL COMMUNICATIONS (Optional):
Type: RS485 Multi-point, Balanced Interface. Communication Format:
Baud Rate: Programmable from 300 to 9600. Parity: Programmable for odd, even, or no parity. Frame: 1 start bit, 7 data bits, 1 or no parity bit, 1 stop bit.
Unit Address: Programmable from 0-99, max. of 32 units per line. Transmit Delay: 100 msec min., 200 msec max. RS485 Common: Isolated from signal input common. Auto Print Time: Off to 9999 seconds between print-outs.
15. USER INPUT: VIN Response time: 100 msec max. Functions:
Program Lock Print Request Integral Action Lock Load Control Point Auto/Manual Transfer Run/Hold Profile 1 Setpoint Ramp Select Run/Stop Profile 1 Reset Alarms
16. ENVIRONMENTAL CONDITIONS: Operating Temperature Range: 0° to 50°C Storage Temperature Range: -40° to 80°C Vibration to IEC 68-2-6: Operational 5-150 Hz, 1 g Shock to IEC 68-2-27: Operational 5 g Span Drift: 90 ppm/°C Zero Drift: 0 to 10 VDC Range - 0.2 mV/°C
4 to 20 mA DC Range - 0.5 µA/°C
Relative Humidity: Less than 85% RH (non-condensing) Altitude: Up to 2000 meters
17. CERTIFICATIONS AND COMPLIANCES: CE Approved
EN 61326-1 Immunity to Industrial Locations Emission CISPR 11 Class A EN 61010-1
RoHS Compliant UL Recognized Component: File #E156876 UL Listed: File #E137808 Type 2 Enclosure rating (Face only) for PSC0 Type 4X/IP65 Enclosure rating (Face only) for PSC1
Refer to EMC Installation Guidelines section of the manual for additional
information.
18. CONNECTION: Jaw-type terminal block.
19. CONSTRUCTION:
Front Panel: Flame and scratch resistant tinted plastic. Case: High impact black plastic. (Mounting collar included). Type 4X/IP65 model only: Sealed bezel utilizing 2 captive mounting screws
(panel gasket included). This unit is rated for Type 4X/IP65 indoor use. Installation Category II, Pollution Degree 2.
20. WEIGHT: 1.3 lbs. (0.6 kgs)
= 5.25 VDC, VIL = 0.85 V
MAX
; VIH = 2.0 V
MAX
MIN
BASIC OPERATION
The PSC controls the process profile of a system by measuring the input signal, comparing it to the setpoint value of the profile in progress, and calculates the new output power value by use of a modified PID control algorithm. The unit controls the system with the new output power value so the process value conforms to the profile. The PID control algorithm incorporates features which provide high control accuracy and low disturbance overshoot.
FRONT PANEL FEATURES
In the normal display mode, the unit will display the scaled process value in the upper display. One of five other parameters may be selected for viewing in the lower display:
Target setpoint % Output Power Profile Status Profile phase time remaining Blank the lower display.
The profile status display indicates the active program number with the current ramp or hold phase of the program. The profile can be started, stopped, advanced, etc., from the front panel when the profile status display is viewed, if not locked from access.
The phase time remaining display, shows the time remaining in a ramp or hold phase and, if not locked from access, may be changed on-line to effect temporary changes to the profile. Additionally, the target setpoint and % output power (manual mode only) may also be changed on-line or locked from operator access.
From the normal operating mode, parameters are selected by use of the PAR button and modified by use of the UP and DOWN buttons. Parameters are then entered by the PAR button, which advances the user to the next parameter. Pressing the DSP button immediately returns the controller to the normal operating mode from any parameter module. The controller configuration and parameter settings are stored in an internal E2PROM device.
HARDWARE FEATURES
The fast 100 msec input sampling rate provides quick controller response to a process disturbance for excellent process control. Measurement accuracy of
0.15% provides closer process control conforming to the desired control setpoint value.
The unit will accept either a 0 to 10 VDC or a 4 to 20 mADC input signal. The A.C. input power is switch selectable, allowing the unit to operate from either 115 VAC or 230 VAC. Since the controller is serviceable from the front of the panel, the output modules may be easily changed or replaced without disturbing the wiring behind the panel and NO re-programming is required. The standard model simply requires pressing a latch to remove the unit. The Type 4X/IP65 rated model utilizes two panel securing screws and a neoprene gasket to guarantee a water tight seal, when properly installed.
Low-drift, highly stable circuit design ensures years of reliable and accurate process control. The recommended two year re-calibration interval is easily accomplished via the programming menu.
Type 4X/IP65 BEZEL
%PW
MAN
OP1
AL1
AL2
PGM
DSP
PAR
3