Red Lion PFM User Manual

Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net
MODEL PFM - PLANT FLOOR MARQUEE
Bulletin No. PFM-A Drawing No. LP0776 Released 05/09
TRI-COLOR DISPLAY PROVIDES INSTANT NOTICE OF
IMPORTANT INFORMATION
DISPLAYS INFORMATION FROM ANY G3 HMI, AND SX/GT
MODELS OF THE DATA STATION AND MODULAR CONTROLLER
GRAPHICAL DESIGN ALLOWS BARGRAPHS, CUSTOM
SYMBOLS AND GRAPHICS
FOUR SIZES FOR A WIDE RANGE OF APPLICATIONS RS-485 PORT SUPPORTS MULTIDROP AC POWERED (110 or 220 VAC, 50 / 60 HZ)
GENERAL DESCRIPTION
The PFM - Plant Floor Marquee series are multi-color LED displays designed to provide vital process and production information to personnel at a glance. The PFM must be used in tandem with Red Lion's G3 series of HMIs, Data Station Plus or Modular Controller series. This affords the PFM the unique ability to display information gathered by its host. The aforementioned host devices can collect information from virtually any device equipped with a serial or Ethernet port.
Four different sizes are available - The smallest is suitable to provide data at the machine level, while the largest can be used to communicate information across an entire factory floor at distances up to 600 feet (182 meters) away.
The PFM displays are controlled via the RS-485 port of a G3 HMI, or Data Station Plus SX/GT models or Modular Controller Master modules. Acting as a slave to these products allows the PFM to display data from multiple industrial devices including PLCs, motor drives, barcode scanners, etc. The RS-485 connection allows the displays to be multi-dropped for applications requiring more than one display.
The PFMs are graphic-based (versus text-based), which allows the series to display items such as bargraphs and custom symbols and graphics. The 7.62 mm (0.3 inch) pitch LED design allows the use of a wide range of font styles and sizes to suit any application. The display is housed in an extruded aluminum and plastic housing designed for indoor use. Brackets are provided to allow the PFM to be mounted from an overhead support.
The PFM is powered by 110 or 220 VAC source. The RS-485 signal connects to the display via an RJ modular plug.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
CONTENTS OF PACKAGE
- PFM display.
- Hardware kit including mounting brackets
- IEC 320 C22 power cable.
- Hex key wrench (models that require it) .
ORDERING INFORMATION
MODEL NO. DESCRIPTION PART NUMBER
Tricolor display 16x80, 110V Tricolor display 16x80, 220V Tricolor display 24x120, 110V Tricolor display 24x120, 220V
PFM
Tricolor display 32x120, 110V Tricolor display 32x120, 220V Tricolor display 64x120, 110V Tricolor display 64x120, 220V PFM6412B
CBL CBL G3/DSP/MC TO PFM CBLPFM00
PFM1608A PFM1608B PFM2412A PFM2412B
PFM3212A PFM3212B PFM6412A
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
CAUTION: Risk of electric shock.
1
SPECIFICATIONS
1. POWER:
PFM1608A: 105-115 VAC, 50/60 Hz @ 75 W max. PFM2412A: 105-115 VAC, 50/60 Hz @ 155 W max. PFM3212A: 105-115 VAC, 50/60 Hz @ 185 W max. PFM6412A: 105-115 VAC, 50/60 Hz @ 267 W max. PFM1608B: 210-230 VAC, 50/60 Hz @ 75 W max. PFM2412B: 210-230 VAC, 50/60 Hz @ 155 W max. PFM3212B: 210-230 VAC, 50/60 Hz @ 185 W max. PFM6412B: 210-230 VAC, 50/60 Hz @ 267 W max.
2. DISPLAY: 7.62 mm (0.3 inch) pitch LED (red/amber/green)
Resolutions: PFM1608x: 16H x 80W PFM2412x: 24H x 120W PFM3212x: 32H x 120W PFM6412x: 64H x 120W Maximum Viewing Distance: PFM1608x: 150 ft (45.72 m) PFM2412x: 200 ft (60.96 m) PFM3212x: 450 ft (137.16 m) PFM6412x: 600 ft (182.88 m)
3. COMMUNICATIONS: Connects to the host G3, Data Station or Modular
Controller (SX or GT models only) via RS-485.
INSTALLING THE PFM
MOUNTING INSRTUCTIONS
PFM1608x, PFM2412x, & PFM3212x
The PFM16, PFM24, & PFM32 displays are designed to be mounted directly to a wall, the ceiling or other suitable structure capable of supporting the PFM. Extreme caution should be exercised when hanging the PFM6412x display to provide for the safety of personnel.
The hardware kit includes mounting brackets, washers, & screws. These are installed into the threaded inserts that are on the sides of the PFM.
4. ENVIRONMENTAL CONDITIONS:
Operating Temperature: 0 to 70 °C. Storage Temperature: -10 to 70 °C. Operating and Storage Humidity: 80% maximum relative humidity (non
condensing) from 0 to 70 °C.
5. CERTIFICA TIONS AND COMPLIANCES:
Contact your Red Lion Controls distributor for more information.
6. CONNECTOR: IEC 320 C22 style; 5 ft. power cord included (US connector)
7. CONSTRUCTION: Extruded aluminum enclosure with ABS endcaps.
8. MOUNTING REQUIREMENTS: Suspend from overhead truss or other
suitable structure. See “Mounting Instructions” for more info. Refer to local safety codes for additional requirements.
9. DIMENSIONS:
PFM1608x: 26" x 6.6" x 2.4" (660 x 168 x 61 mm) PFM2412x: 38.5" x 8.8" x 3.4" (978 x 224 x 86 mm) PFM3212x: 38.8" x 10.9" x 3.4" (986 x 277 x 86 mm) PFM6412x: 39.3" x 22.6" x 3.4" (998 x 572 x 86 mm)
10. WEIGHT:
PFM1608x: 6.8 lbs. (3.1 Kg) PFM2412x: 14.1 lbs. (6.4 Kg) PFM3212x: 17.0 lbs. (7.7 Kg) PFM6412x: 28.7 lbs. (13.0 Kg)
PFM6412x
The PFM64 display is designed to be mounted directly to the wall, suspended from a ceiling truss or other suitable structure capable of supporting it. Extreme caution should be exercised when hanging the PFM6412x display to provide for the safety of personnel.
MOUNTING BRACKET
SCREW
RAIL
Installing bracket:
1. Remove one of the screws in the top of the PFM.
2. Slide both of the mounting brackets into the rail.
3. Reinstall screw removed in step 1.
13
SCREW
2
2
CEILING
MOUNTING BRACKET
WALL
RAIL
POWERING THE PFM
The PFM is fitted with an IEC 320 C22 connector. A five foot long, grounded three-prong connector cable is included with each unit. The PFM is powered by 110 VAC, 50/60 Hz or 220 VAC, 50/60 Hz depending on the model chosen.
CHAIN
COMMUNICATING WITH THE PFM
The PFM requires a host product in the form of a G3, Data Station Plus or Modular Controller. Further, only models that have a User Interface may be used as a host. This excludes products such as the DSPLE and CSMSTRLE. See the relevant product bulletins for more information.
The CBLPFM00 may be used to connect the RS-485 port of the host product to the RS-485 port of the PFM.
RS485
5' POWER CABLE
PFM1608X PFM3212X
CBLPFM00
RJ11
PFM2412X PFM6412X
RS485
3
CBLPFM00
RJ11
The Company warrants the products it manufactures against defects in materials and workmanship
LIMITED WARRANTY
for a period limited to two years from the date of shipment, provided the products have been stored, handled, installed, and used under proper conditions. The Company’s liability under this limited warranty shall extend only to the repair or replacement of a defective product, at The Company’s option. The Company disclaims all liability for any affirmation, promise or representation with respect to the products.
The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries, deaths, property damage, lost profits, and other matters which Buyer, its employees, or sub-contractors are or may be to any extent liable, including without limitation penalties imposed by the Consumer Product Safety Act (P.L. 92-573) and liability imposed upon any person pursuant to the Magnuson-Moss Warranty Act (P.L. 93-637), as now in effect or as amended hereafter.
No warranties expressed or implied are created with respect to The Company’s products except those expressly contained herein. The Customer acknowledges the disclaimers and limitations contained herein and relies on no other warranties or affirmations.
Red Lion Controls Headquarters 20 Willow Springs Circle York PA 17406 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839
Red Lion Controls
Europe
Printerweg 10
NL - 3821 AD Amersfoort
Tel +31 (0) 334 723 225
Fax +31 (0) 334 893 793
Red Lion Controls
India
54, Vishvas Tenement
GST Road, New Ranip,
Ahmedabad-382480 Gujarat, India
Tel +91 987 954 0503
Fax +91 79 275 31 350
Red Lion Controls
China
Unit 101, XinAn Plaza
Building 13, No.99 Tianzhou Road
ShangHai, P.R. China 200223
Tel +86 21 6113-3688
Fax +86 21 6113-3683
Loading...