Raytek CI1A, CI2A, CI3A, CI1B, CI2B Data sheet

...
CI
RAYTEK COMPACT™ SERIES
Noncontact Temperature Measurement for Industrial Applications
Datasheet
Spectral Response 7 to 18 microns
System Repeatability ±1% of measured value or ±1°C (2°F), whichever is
greater
Temperature Resolution <0.5°C or 1°F
Emissivity Fixed at 0.95
Measurement Specifications
Nominal Optical Specifications
Type J or K, or 0-5 V output
Two models cover temperature ranges from 0°C to 500°C (32°F to 932°F)
IP 65 (NEMA-4) stainless steel electronics housing
4:1 optics at 90% energy
350 mSec (95%) response time
Powered by 12–24 VDC at 20 mA
Accessories for cooling and air purging
The Raytek CI model provides the advan­tages of infrared temperature measure­ment in a compact, low cost, integrated sensor. Designed for easy integration into a standard 4-wire system, the CI sensor can easily replace traditional contact probes with a J-type or K-type thermo­couple output, or with a 0-5 volt output if your application is susceptible to noise or requires a longer cable run.
The CI sensor is designed to measure target temperatures ranging from 0°C to 500°C (32°F to 932°F). The CI unit's onboard electronics are protected by a rugged IP 65 (NEMA-4) stainless steel housing, allowing the sensor to function in ambient temperatures to 70°C (160°F) without cooling. With water cooling, the CI sensor can withstand ambient temperatures to 260°C (500°F).
Because the CI unit has the same 50 Ohm output impedance as a thermocouple, it functions accurately— without offset errors—when used in conjunction with the thermocouple break protection circuitry in most controllers, displays, and transmitters.
Compact. Easy to install. Affordable. The Raytek CI sensor is ideal for both OEM and end-user applications.
D:S is the optical resolution expressed as a ratio of the distance to the resolu­tion spot divided by the diameter of the spot.
Optical resolution for the CI sensor is 4:1. Nominal spot size based on 90% energy.
CI Highlights
Model
Output Overall Temp.
Range
30 to 500ºC
(86 to 932ºF)
0 to 115ºC (32 to 240ºF)
±3º C (±6º F)
116 to 225º C (241 to 440ºF)
larger of ±5% or ±6º C (±10º F)
226 to 350º C (441 to 662º F)
>±5%
Accuracy
100 to 500ºC (212 to 932ºF)
larger of ±2% or ±3º C (±6º F)
30 to 99º C (86 to 211º F)
±6º C (±10º F)
0 to 350ºC
(32 to 662ºF)
CI3A
CI2A
CI1A
CI3B
CI2B
CI1B
Voltage
K Thermocouple
J Thermocouple
Voltage
K Thermocouple
J Thermocouple
Outputs User-selectable thermocouple out-
put (model specific, either J or K) or voltage output 10 mV/°C
Cable Length 1 m (3.2 ft) standard, longer
cables optional
Output Impedance 50 ohms
Minimum Load Impedance 50K ohms
Power Supply 12–24 VDC (2.5% ripple) @ 20 mA
Environmental Rating IP 65 (NEMA-4)
Ambient Temperature Range 0 to 70°C (32 to 160°F)
With air cooling 0 to 90°C (32 to 200°F) With water cooling 0 to 260°C (32 to 500°F)
Storage Temperature -30 to 85°C (-22 to 185°F)
Relative Humidity 10 to 95%, non-condensing
Shock IEC 68-2-27 (MIL STD 810D)
50 g’s, 11 mSec, any axis
Vibration IEC 68-2-27 (MIL STD 810D)
3 g’s, any axis, 11–200 Hz
Weight 130 g (4.5 oz)
Sensor Specifications
Electrical Specifications
Sensor Dimensions
Each CI sensor includes two mounting nuts, 1 m (3.2 ft.) of cable, and an operator’s manual. Longer cables up to 15 m (50 ft.) maxi­mum are available and must be specified at the time of order.
Accessories Options
Adjustable or fixed
mounting bracket for
sensing head (XXXCIADJB or
XXXCIACFB)
Right angle mirror to ease
installation into tight locations
(XXXCIACRA)
Air purge jacket to keep lens or right angle mirror clean (XXXCIAP or XXXCIACAPM for metric version)
Optional water/air cooling/purging system for high temperature environments up to 260°C (500°F)
Optional cooling jacket must be specified at the time of order.
© 2004 Raytek Corporation (2-1302 Rev. C) 8/2004
Raytek and the Raytek logo are registered trademarks and
Compact Series and CI are trademarks of Raytek Corporation.
Specifcations subject to change without notice.
A
Model Description
RAYCI Raytek infrared temperature sensor
Code A Response
1 Type J Thermocouple Output 2 Type K Thermocouple Output
Code B Temperature Range
A ±2% or ±3º C accuracy between 0º and 115º C (32 to 240º F) B
±2% or ±3º C accuracy between 100º and 500º C (212 to 932º F)
Code C
Options
M W
18Mx1 metric thread on sensor in place of standard thread Water cooled jacket with bulit-in air purging and 1m (3’) high temperature cable
3 Voltage Output (Linear 10 mV / ºC, scaled 0-5V)
Typical Model Number
RAYCI1AW
www.raytek.com
for up-to-the-minute features
Raytek Automation Products: Noncontact Temperature Measurement for Industrial Applications
Raytek Corporation Worldwide Headquarters
1201 Shaffer Rd. PO Box 1820 Santa Cruz, CA 95061-1820 USA Tel: 1 800 866 5478
1 831 458 1110
Fax: 1 831 425 4561
solutions@raytek.com
To find a Raytek office near you please visit www.raytek.com
Worldwide Service
Raytek offers services including emergency repairs and calibration. For more information, contact your local office or e-mail: support@raytek.com
B