Raytek 3i Specifications

Page 1
Handheld Infrared Thermometer
RAYTEK® RAYNGER® SERIES
3i
Specialized
Models for
Specialized
Applications
Advanced applications and processes need specialized
tools like the Raynger
®
3i IR (infrared) thermometer.
Page 2
Raynger 3i Series
vercome the limitations of contact thermometers in manufacturing plants with Raynger 3i series
O
accurate readings in hot environments, the 3i thermometer compensates for the energy
reflected by the background around the target.
Reflected background energy compensation
allows for accurate measurement even when the
area measured is reflecting energy from nearby objects
with higher temperatures; for example, inside a furnace. Varying spectral responses, laser-sighting systems, and distance-to­measurement spot ratios ensure the Raytek 3i temperature measurements are precise.
infrared thermometers. For the most
LT and LR
For maintenance and quality control applications, the Raytek 3i Low Temperature (LT) and Long Range (LR) models are available for various temperature range and optical requirements. The strong 105:1 distance-to-spot ratio of the 3i LRL2SC thermometer combined with a –30 to 1200°C (-20 to 2200°F) temperature range and scope permits easy temperature of elevated objects at great distances, electrical connectors in towers.
Useful in the following manufacturing situations:
Utilities
Electrical Connectors
Plant Maintenance
Paper Production
Fire Safety
measurements such as
Page 3
Laser Sighting Options
FOCUS POINT D:S = 75:1 @15 m (50 ft) FAR FIELD D:S = 68:1
15
10
20
305
40
3
6
91.5
12
50
0
0
1.3
2.0
5.0
3.5
8.0
33
51
124
6.5
86
165
203
DISTANCE (SENSOR TO OBJECT IN METERS)
DISTANCE (SENSOR TO OBJECT IN FEET)
IR Spot Diameter at Lens = 23 mm (0.9 in) Laser Diameter at Lens = 40 mm (1.6 in)
IR Beam Profile
Laser Profile
LTDL2 LTDL3
Spot Diameter (in)Spot Diameter (mm)
LRSCL2
FOCUS POINT D:S = 105:1 @ 15 m (50 ft) FAR FIELD D:S = 90:1
IR Spot Diameter at Lens = 23 mm (0.9 in)
2.8
1.9
3.8
4.8
119
95
47
5.7
71
143
15
10
20
30
40
3
6
9
12
50
0
0
DISTANCE (SENSOR TO OBJECT IN FEET)
DISTANCE (SENSOR TO OBJECT IN METERS)
Spot Diameter (in)Spot Diameter (mm)
LRL2 LRL3 LRSC
FOCUS POINT D:S = 120:1 @ 15 m (50 ft) FAR FIELD D:S = 100:1
IR Spot Diameter at Lens = 23 mm (0.9 in)
2.4
1.7
3.3
4.1
102
81
43
5.0
61
124
15
10
20
30
40
3
6
9
12
50
0
0
DISTANCE (SENSOR TO OBJECT IN FEET)
DISTANCE (SENSOR TO OBJECT IN METERS)
Spot Diameter (in)Spot Diameter (mm)
LTCL2 LTCL3
5000
300015001000
36
60
120
180
0
0
0.9
1.9
4.6
7.3
23
48
118
FOCUS POINT D:S = 75:1 FAR FIELD D:S = 20:1
0.3 IN @ 24 IN
8 mm @ 610 mm
Focus Point
IR Spot Diameter at Lens = 23 mm (0.9 in) Laser Diameter at Lens = 40 mm (1.6 in)
IR Beam Profile
Laser Profile
203
DISTANCE (SENSOR TO OBJECT IN INCHES)
DISTANCE: (SENSOR TO OBJECT IN MILLIMETERS)
Spot Diameter (in)Spot Diameter (mm)
LTSC
FOCUS POINT D:S = 75:1 FAR FIELD D:S = 40:1
IR Spot Diameter at Lens = 23 mm (0.9 in)
0.8
0.9
Focus Point
1.0 IN @ 75 IN
2.1
3.6
20
23
25 mm @ 1900 mm
53
97
5000
300015001000
36
60
120
180
0
0
DISTANCE (SENSOR TO OBJECT IN MILLIMETERS)
DISTANCE (SENSOR TO OBJECT IN INCHES)
Spot Diameter (in)Spot Diameter (mm)
Single Laser (L2, L3)
Single laser models are designed for accuracy over distances and pinpoint the center of the target area with a bright laser spot. The single laser L3 unit is equipped
Dual Laser (DL2, DL3)
The dual laser uses two laser spots to indicate the diameter of the target area measured.
Crossed Laser (CL2, CL3)
For precise measurement of smaller targets, minimum measurement spot is indicated at the point the two laser
beams meet. with a 4 milliwatt laser, providing the brightest laser guide.
Models ending with L2 meet FDA Class II and IEC Class 2 requirements. Models ending with L3 meet FDA Class IIIa requirements.
Optical Resolution D:S (distance to spot using 90% encircled energy at focal point)
Long Range
Low Temperature
Low Temperature
Scope Only (SC) or Scope with Laser (SCL2)
Measure temperature at a distance in bright daylight. At the focus point, 3i scopes are parallax-free and provide circular reticles for pinpoint accuracy. To enhance the sighting capabilities of the scope, combine the scope with a laser equipped model.
Long Range
3i Models
Single Laser (L2) Class II
Single Laser (L3) Class IIIa
Dual Laser (DL2) Class II
Dual Laser (DL3) Class IIIa
Crossed Laser (CL2) Class II
Crossed Laser (CL3) Class IIIa
Sighting Options
Scope (SC)
Scope with Laser (SCL2) Class II
Low Temperature
Low Temp (LT) Long Range (LR)
-
-
LTDL2
LTDL3
LTCL2
LTCL3
LTSC
-
LRL2
LRL3
-
-
-
-
LRSC
LRSCL2
Page 4
Model
LT LR LRSCL2
Temperature Range
Accuracy
Repeatability ±0.5% of reading or ±1ºC ( ± 1ºF), whichever is greater Response Time (95%) 700 mSec Spectral Response 8 to 14µm Adjustable Emissivity*
(from 0.1 to 1.0 by 0.01) Ambient Operating Temperature 0ºC to 50ºC (32ºF to 120ºF) Relative Humidity 10 to 90%, noncondensing @ up to 30ºC (86ºF) Storage Temperature -20ºC to 50ºC (-4ºF to 120ºF) without batteries
Dimensions/Weight
Power 4 AA batteries or 6 to 9 V, 200 mA DC power supply Battery Life (Alkaline) 21–25 hours Laser L2 models are IEC Class2/FDA Class II (<1mW), L3 models are FDA Class IIIa (<5mW) Reflected Energy Compensation Distance to Spot (D:S) 75:1 MAX, MIN, DIF, AVG Temperatures Display Hold Backlit LCD Temperature Display ºC or ºF (selectable), multifunction 4-digit backlit LCD Display Resolution Locking Trigger Tripod Mounting Audible/Visible Hi/Lo Alarms
Analog Output 1mV/ºC or 1mV/ºF
Digital Output RS232, 9600 baud, output interval adjustable from 1 to 9999 seconds
Specifications and Features
100 Point Data Logging
Laser Models: 208 H x 257 L x 71 W mm / 794 g (8.2 H x 10.1 L x 2.8 W in / 1.75 lb)
Scope Models: 244 H x 257 L x 71 W mm / 1000 g (9.6 H x 10.1 L x 2.8 W in / 2.21 lb)
-30ºC to 1200ºC (-20ºF to 2200ºF)
±1% of reading or ±1ºC (±1.5ºF)
whichever is greater at 23ºC ±5ºC
(73ºF ±9ºF) ambient operating temperature
120:1
7 Seconds
1ºC or 1ºF
105:1
Options/ Accessories
* For more details visit www.raytek.com/emissivity.htm
Raytek Corporation Worldwide Headquarters
Santa Cruz, CA USA Tel: 1 800 227 8074 (USA and Canada, only)
1 831 458 3900
solutions@raytek.com
European Headquarters
Berlin, Germany Tel: 49 30 4 78 00 80
raytek@raytek.de
China Headquarters
Beijing, China Tel: 8610 6438 4691
info@raytek.com.cn
To find a Raytek office near you, please visit www.raytek.com
Worldwide Service
Raytek offers services, including repair and calibration. For more information, contact your local office or e-mail support@raytek.com
The Worldwide Leader in Noncontact Temperature Measurement
Nylon carry case with shoulder strap • NIST Certification (Must be specified at time of order)
Variable brightness filters (scope only) • 110V/60Hz or 220V/50Hz voltage adapters
• Computer, analog, and printer cables • DataTemp
www.raytek.com
Raytek and the Raytek logo are registered trademarks of Raytek Corporation.
© 2015 Raytek Corporation (3111659 Rev. G) 2/2015
Windows is a registered trademark of Microsoft Corporation.
All other trademarks are the property of their respective owners.
®
2 software
Specifications subject to change without notice.
Loading...