Raytec VARIO2 w16, VARIO2 series, VARIO2 i16, VARIO2 w8, VARIO2 i6 Installation Manual

...
Page 1
1 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Installation Guide
Contents :
Page 2 Box Contents and Safety Information Page 3 Short Guide and Factory Defaults Page 6 LED Status Indicators – Feedback System Page 8 VARIO Remote Controller (VRC) Page 10 PIN Function Detail Page 12 Manual Control Buttons Page 17 Disabling Manual Buttons Page 18 Power Up Functionality ; Re-Set Options Page 19 Standard Bracketry Page 20 Specifications Table Page 21 Troubleshooting Page 24 Quick reference Tables for Manual Button Control and
Remote control for PIN Set and Manual Button Disable/ Enable
Page 2
2 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Box Contents :
VARIO2 Illuminator , 60° beam angles ILS (ILS: Interchangeable Lens System) Accessories (Optional) :VARIO Remote Control for additional Programming; 80˚ beam and 120˚ beam angle ILS; Bracketry
VARIO2 Enhancements
Increased Distance
Default time for illuminator to go into Operating Mode reduced
PIN function for enhanced security
Manual Control added – Push Buttons Accessible on the illuminator
Improved RESET Options
The 3 single colour feedback LED’s have been replaced with 2 tri-colour LED’s
Safety Information
Eye Safety : IR Variants (850nm and 940nm)
Caution – IR emitted from this product EN62471 Risk Group 2 Do not stare at the lamp. Avoid exposure or use appropriate shielding / eye protection. Risk Group 2 for cornea / lens infrared hazard. For VAR-i2, VAR-i4, VAR-i6 and VAR-i8 variants hazard distance is 1500mm. For VAR-i16 hazard distance is 1840mm. Max IR EHV (Exposure Hazard Value) : 69% of Risk Group 2 Limit at 200mm from the lamp.
Eye Safety : White Light Variants
Caution – EN62471 Risk Group 2 Classification - Possible hazardous optical radiation emitted from this product. May be harmful to eyes, do not stare at the lamp. For VAR-w2, VAR-w4, VAR-w8 Hazard distance is 1500mm. For VAR-w16 hazard distance is 1840mm. Max WL EHV (Exposure Hazard Value) : 68% of Risk Group 2 Limit at 200mm from the lamp.
Page 3
3 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Installation Steps – Short Guide :
1. VARIO2 is factory set and delivered with a 35˚
beam width. To alter to 10˚, simply remove interchangeable lens (ILS). See page 4 for detailed instructions To alter to 60˚, replace with other ILS lens supplied.
2. Mount Illuminator
3. Connect Illuminator to low voltage input 12-24V
AC/DC (For Vario 16 variants : 24V AC or DC only) 4-6. Complete configuration, wiring and final set-up using manual push buttons on the illuminator or VARIO Remote Controller (VRC)
- VRC is an optional accessory
Wiring – six core cable
White & Yellow wires = Photocell following contact, Volt free output, Non polarity sensitive
Orange and Purple Wires =
Telemetry input Volt free / dry contact or TTL input (see Page 5 and 6 for more detail)
DC AC Black Wire - ~
Red Wire + ~
Photocell
Cable
Breather
Gland
Page 4
4 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Factory Default Set-Up:
35˚ Beam Angle ; Max 100% Power Telemetry Input – closed ; Photocell sensitivity – MID Status LEDs – ON ; No PIN Set ; Manual Button Control Enabled Programming function will auto-disable after 7 Days
VARIO2 Complete Set up and Installation Step 1. Select different beam angle – if required
To alter to 10˚, simply remove interchangeable lens (ILS).
To alter to 60˚, replace with other ILS lens supplied.
Other angle ILS lenses are available to order: 80˚ and 120˚.
All ILS lenses will be clearly marked with the angle which they will produce when inserted into VARIO2.
Please handle ILS lenses with care – and do not touch optical film.
Only 1 ILS lens can be inserted into the product at anytime. The product cannot accommodate multiple ILS lenses at the same time.
We would recommend that power is turned off when replacing ILS lenses.
Remove base plate from VARIO2 unit using 2.5mm allen/hex key. Insert required ILS lens and re-attach base plate securely ensuring gasket is correctly located.
VARIO is factory set and delivered with a 35˚ beam width angle.
Important Note : Ensure base plate is securely located, the gasket is correctly located and the screws correctly fastened to ensure and maintain IP66 rating of the product
Page 5
5 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Step 2. Mounting Illuminator VARIO2 is delivered as standard with bracket at the bottom of the unit.
This can be moved to the top of the unit if required. See page 18 for optional brackets
Step 4. Telemetry Input (Orange & Purple) As default the telemetry input will be wired together so that the unit turns
on/off automatically via the photocell. If required to be activated by PIR or alarm system, connect to appropriate, volt-free or TTL input. Volt free input/dry contact: Non polarity sensitive, short circuit = light on
TTL input: Orange = TTL +ve, Purple = TTL –ve (GND) 0V = Light on, 3V = Light off
Page 6
6 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Step 5. Photocell following output (White & Yellow) Volt free output - normally open (day) to normally closed (night).
Connect direct to camera if required to control switchover of day/night cameras.
Step 6. Programme using optional VARIO Remote Control (VRC) or the manual control buttons.
Step 7. Set PIN (If Required) (Can only be done with the optional VARIO Remote Control(VRC)
LED Status Indicators- Feedback system :
There are two tri-coloured LEDs visible on the base of the VARIO2 illuminator. The two LEDs provide important operating and status information.
The status information provided by each of these LEDs differs depending on which of the two operating modes the VARIO2 illuminator is in: (A) Programming OR (B) Operating
The LED Indicators also give feedback if you are using the Remote, PIN Function or Manual Control Modes – Please see Pages 10 to 17 for detail on the LED status indicator feedback for these functions
(LHS) (RHS)
Page 7
7 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Programming Mode and Operating Mode
On powering up the illuminator, it automatically enters programming mode to allow the user to adjust set-up and operation. The programming mode automatically times out after 7 Days or until the user actively disables the programming mode and changes to Operating Mode
During Programming Mode and Operating Mode the two LED’s indicate the following status (unless detailed below):
LHS SOLID GREEN: Power Applied LHS FLASHING GREEN: Remote control IR receiver problem (Max
VRC distance is 8m (26ft)
RHS FLASHING AMBER: Indicates unit is in programming mode
(Programming Mode Only)
RHS SOLID AMBER: Indicates that a valid command is being
received from the remote (Programming
Mode Only) LHS FLASHING RED: Voltage supply problem detected LHS SOLID RED: Illuminator fault detected All functions of the remote control and buttons are available in
Programming Mode.
The only function of the Remote Control available during Operating Mode is LED Status Indicators Enable/Disable, entering a PIN or disabling manual buttons (if done at the same time as
disabling the remote – see P.17)
Factory Default: On initial power-up, Programming Mode.
Page 8
8 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
VARIO Remote Controller (VRC) :
Optional Accessory Full instructions provided with VRC when supplied
Note : Reset button will not remove a PIN if one is present Note : Unless detailed as part of the functionality, if an invalid or
blocked command is attempted, both LEDs will flash RED
Page 9
9 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Extra VRC Functionality :
- PIN Function
For extra security VARIO2 allows a PIN (Personal Identification Number) to be set for each lamp
The PIN is set by using the Vario Remote Control (VRC). There are five buttons / characters on the remote that can be used for this purpose. Please see PIN Function Detail (P. 10) for full details on how to use the PIN function.
Note : Unless detailed as part of the functionality, if an invalid or blocked command is attempted, both LEDs will flash RED
Page 10
10 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
PIN Function Detail :
The PIN is set by using the Vario Remote Control (VRC). There are five buttons / characters on the remote that can be used for this purpose. They are Power 5, Power 1, Min Photocell (Smallest moon), Max Timer (Full Red Circle) & Timer Disable ( Timer Circle image with a line through) . Note – invalid characters will not be recognised.
To create a PIN, press STATUS BUTTON for 4 seconds. LHS LED will flash RED/GREEN. This indication will always show that you are in PIN mode. RHS LED FLASHING RED shows there you are in PIN set mode. The number of flashes indicates how many characters are required to complete the PIN entry. There are four characters to be entered to successfully set up a PIN.
As you enter the characters, the number of flashes will decrease until all characters are entered. Note, illegal characters will not be recognised and will not reduce the number of flashes. When the PIN is set the illuminator will revert to Programming Mode.
When a PIN is Set : Using the remote you can access the illuminator settings from operating
mode by entering the PIN. You cannot access Programming Mode by power re-cycling only.
In operating mode, if you want to go back into programming mode simply enter your PIN. To do this, press STATUS BUTTON for 4 seconds. LHS LED will flash RED/GREEN to show you are in PIN mode. RHS LED FLASHING GREEN shows that a PIN has been previously set. As you input the four correct characters the number of flashes will reduce and you will be returned to programming mode.
If legal characters but not the correct sequence of characters is entered the number of flashes will still reduce and after 4 characters have been entered an error will be shown by both LED`s flashing RED.
Page 11
11 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
If an illegal character is used when entering a pin, it will be ignored and the PIN character count will not reduce. The process to enter a PIN will have to be repeated.
To delete a PIN you first need to be in Programming Mode. Press STATUS BUTTON for 4 seconds to go into PIN set mode. LHS LED will flash RED / GREEN. RHS LED FLASHING RED. Instead of entering one of the known legal characters press the RESET BUTTON four times. The illuminator will return to program mode. Note – if you delete the PIN and the illuminator goes into operating mode, you will not be able to go back to program mode without recycling the power.
*Note - If you forget your pin and need to make adjustments to the illuminator you need to do full Re-set. This requires power recycling whilst pressing the two manual control buttons at the same time. This will restore factory default settings AND remove the previously programmed PIN. Both LEDs will flash AMBER to signify that the process has been completed.
*Note – If you do not want to set a PIN, but want to prevent another person with a remote setting a PIN, then you need to Disable both the Remote and the Manual Buttons (See Manual Control Buttons section – Page 12) The only way another user can then access the illuminator is by performing a full re-set (see Page 18)
*Note – If you are trying to access a PIN in Operating Mode, hold the status button down for 4 seconds and both LEDs flash RED, this means there is no PIN present.
Page 12
12 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Manual Control – Buttons :
The two manual control buttons gives a wide selection of user control :
1. Power Control – 100%, 80%, 60%, 40%, 20% of maximum. (Factory
Default is 100%)
2. Photocell Control – 3 levels, 25 Lux on, 50 Lux off, 10 Lux on 30 Lux off, 5 Lux on 15 Lux off and photocell disable.
3. Turn LED indicators on & off
4. Illuminator Reset Options
5. Disable Remote Control and enter Operating Mode or Enable Remote Control and enter Programming Mode
6. Button Enable & Disable
Page 13
13 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Manual buttons can be accessed by removing the base cover of the illuminator
The buttons are active in both programming mode and operating mode regardless of whether a PIN is present or not unless you have previously disabled the manual buttons
As soon as manual button mode is entered by pressing the Left Hand Button, the standard LED indicators will be disabled and offer a new set of indicating modes, Standard LED indicators are enabled after exiting manual button modes.
Note : Unless detailed as part of the functionality, if an invalid or blocked button push is attempted, both LEDs will flash Red
Manual Mode Selection by using LHS Button : A momentary press of LHS button turn LHS LED solid RED and enters the
user into the Illuminator Setting Modes. In these modes you can change the following settings :
- Power Level
- Photocell sensitivity
- Indicator LED status (On or Off)
A continuous 4 second press of the LHS button turns LHS LED flashing RED and enters the user into the Illuminator Configuration Modes.
In these modes you can change the following Configurations :
- Illuminator Re-set
- Disable Remote Control and enter Operating Mode or Enable Remote Control and enter Programming Mode
- Manual Button Enable / Disable
*Note – If the status indicator LEDs are disabled and you use the manual buttons the indicator LEDs will still illuminate accordingly
Page 14
14 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Manual Setting / Level Indication using RHS Button : The RHS BUTTON will only have an effect if you have selected a mode
using LHS Button – pressing RHS Button without previously pressing LHS Button will have no effect on the Illuminator operation – it is used to control the setting for the mode chosen by LHS Button
When you select a mode using LHS BUTTON, the LHS LED will confirm which mode you are in and RHS LED will show the current setting / level of that mode for the Illuminator.
Sequential presses of RHS BUTTON will take you through the available options to get to the required setting you want within that mode. The Illuminator will stay at this setting / level providing you do not push the RHS BUTTON again. Once you have reached the required setting as shown in the following text, either press the LHS BUTTON to cycle through the modes until LHS LED extinguishes showing that you are at the end of the mode loop.
You can also wait 2 minutes for the illuminator to time out and the value shown by RHS LED will be stored into the illuminator memory.
The settings programmed will be retained on power recycling unless a reset has been performed, in which case the factory defaults will be applied
Page 15
15 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Illuminator Setting Modes Detail :
Enter this mode by a momentary press of LHS button to turn LHS LED solid RED.
Pressing the LHS button again will turn the LED solid GREEN and pressing a third time will turn the LED solid AMBER. Each of these colours indicates which setting mode you are in.
A further momentary press of LHS Button will exit from the mode entry, both LEDs will go out for 1 second and then return to the standard indication of either operating mode or programming mode (depending on which mode the Illuminator was in previously before selecting manual controls
The following modes are available :
Power Level Mode (LHS LED : Solid RED) RHS LED : 20% Power Setting: 1 Flash GREEN 40% Power Setting: 2 Flashes GREEN 60% Power Setting: 3 Flashes GREEN 80% Power Setting: 4 Flashes GREEN 100% Power Setting: 5 Flashes GREEN
Photocell Level Mode (LHS LED : Solid GREEN) RHS LED: Low sensitivity: 1 Flash GREEN Medium Sensitivity: 2 Flashes GREEN High Sensitivity: 3 Flashes GREEN Disabled photocell: Solid RED
Enable / Disable Status Indicator LEDs Mode (LHS LED: Solid AMBER) RHS LED: Enable LEDs: Solid GREEN Disable LEDS: Solid RED NOTE – If no buttons are pressed within 2 minutes the Illuminator times out
and returns to the previous mode it was in – either operating or programming mode.
Page 16
16 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Illuminator Configuration Modes Detail :
Enter this mode by a long 4 second press of LHS button to turn LHS LED Flashing RED.
Pressing the LHS button again momentarily will turn the LHS LED Flashing GREEN and pressing a third time momentarily will turn the LHS LED Flashing AMBER. Each of these colours indicates which setting mode you are in.
A further momentary press of LHS Button will exit from the mode entry, both LEDs will go blank for 1 second and then return to the standard indication of either operating mode or programming mode (depending on which mode the illuminator was in previously before selecting manual controls)
The following modes are available :
Illuminator Reset Mode (LHS LED : Flashing RED) RHS LED: Solid RED Keep RHS BUTTON depressed for 4 seconds. RHS LED stays solid RED and
then after 4 seconds both LEDs flash AMBER to show the illuminator has been reset. This operation is equivalent to the factory reset button on the remote control. It will not re-set a PIN if one is present.
Remote Control Disable and Enter Operating Mode or Remote Control Enable and enter Programming Mode (LHS LED : Flashing GREEN)
RHS LED: Enable Remote: Solid GREEN Disable Remote: Solid RED Note : If the a PIN is present and the Illuminator is in Operating mode you
cannot enable the Remote Control and enter Programming Mode
Enable & Disable of Manual Control Buttons (LED A : Flashing AMBER) RHS LED: Enable Manual Button Control – Solid GREEN Disable Manual Button Control – Solid RED Note : If the illuminator is in Operating Mode and the buttons are
currently disabled, you cannot re-enable.
Page 17
17 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
NOTE – If no buttons are pressed within 2 minutes the illuminator times out and returns to the previous mode it was in – either Programming Mode or Operating Mode.
Disabling the Manual Buttons :
If the Illuminator is in Operating Mode, once the disable manual buttons command is executed the buttons will be disabled after 30 minutes. This is to allow the user to re-enable manual buttons if required.
During this 30 minutes the button response will be the following
- LHS Button
o Illuminator Settings Modes cannot be accessed. A momentary
press of the button will not be recognised and the indicator LEDs will not change
o Illuminator Configuration Modes can be accessed in the normal
way by a continuous 4 second press
- RHS Button
o Pushing this button will cause both indicator LEDS to flash RED
Once the 30 minutes has expired any button push (LHS or RHS) will cause both indicator LEDs to flash RED and the manual buttons are fully disabled
Disabling the Manual Buttons Using the Remote :
The manual buttons can be disabled using the remote. Once the illuminator is put into Operating mode if the disable remote
control Set Up button (see diagram on Page 8) is pressed again and held for 4 seconds the manual buttons will be disabled. This is shown by both indicator LEDs flashing RED after 4 seconds.
Note : This command can only be used within 5 minutes of the illuminator being put into Operating Mode
(If the Manual Buttons are already Disabled , both LEDs will flash RED straight away)
Page 18
18 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Power Up Functionality :
After power is supplied to the unit : If no PIN is present the Illuminator will go into Programming Mode for 7
Days and then will default to Operating Mode
- During this time if the remote is used to change settings the illuminator
will still default into Operating Mode after 7 Days from the power up (unless the remote disable button is used to change the illuminator to Operating Mode)
- During this time if the manual buttons are used in either Illuminator
Settings Modes or Illuminator Configuration Modes the Illuminator will default into Operating Mode 30 minutes after the last button press
RESET Options :
There are Two Re-set options for resetting your VARIO2 illuminator
Settings Re-set : Pressing and holding the RESET BUTTON on the remote control or using
the manual buttons to complete a RESET will restore the factory settings to the illuminator. Note : If a PIN is present it will not be removed and the illuminator will return to the mode you were in (Programming or Operating) prior to the re-set command. Both indicator LEDs will flash AMBER when completed.
Full Re-Set : The other option to reset your illuminator is available by recycling the
power whilst holding down the two manual buttons. This is a FULL RESET and will restore factory settings AND remove the PIN if one has been set.
Both Indicator LEDs will flash AMBER when completed.
Page 19
19 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Standard Bracketry :
Supplied with the Product (Model Dependant)
(
not to scale, dimensions rounded to nearest mm)
Optional Bracketry (
not to scale - other Bracketry also available
)
VUB-Pole VUB-Wall VUB-Plate VUB-PSU Plate
Wall Mount PTZ Mount Dome Mount Pole Mount
Page 20
20 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
VARIO2 Specifications Table :
Infra-Red Series & White-Light Series
i16
w16
i8
w8
i6
i4
w4
i2
w2
10°
500m
(1640ft)
250m
(820ft)
350m
(1148ft)
180m
(591ft)
200m
(656ft)
144m
(472ft)
110m
(361ft)
78m
(256ft)
60m
(197ft)
35°
250m
(820ft)
125m
(410ft)
165m
(541ft)
95m
(312ft)
120m
(394ft)
78m
(256ft)
65m
(213ft)
54m
(177ft)
40m
(131ft)
60°
135m
(443ft)
70m
(230ft)
95m
(311ft)
50m
(164ft)
70m
(230ft)
54m
(177ft)
35m
(115ft)
36m
(118ft)
25m
(82ft)
80°
105m
(344ft)
48m
(157ft)
70m
(230ft)
35m
(115ft)
50m
(164ft)
36m
(118ft)
25m
(82ft)
24m
(79ft)
20m
(66ft)
120°
65m
(213ft)
35m
(115ft)
45m
(148ft)
25m
(82ft)
30m
(98ft)
24m
(79ft)
18m
(59ft)
18m
(59ft)
12m
(39ft)
Consumption
100W
max
84W max
46W max
42W max
25W max
13W max
24W max
10W max
11W max
Input
24V AC/DC
12-24V AC/DC
12-24V AC/DC
12-24V AC/DC
Weight
3.1kg (6.8lbs)
1.65kg (3.61lbs)
950g (2.1lbs)
600g (1.3lbs)
Number of
LED’s
48
24
12 9 12 6 6
Environment
IP66
IP66
IP66
IP66
Dimensions
180 x 277 x 75mm
7”x11”x2.9”
135 x 180 x 68mm
(5”x7”x3”)
100 x 135 x 66m
4”x5”x2.5”)
75 x 100 x 64mm
3”x4”x2.5”)
Cable Length
2.5m
2.5m
2.5m
2.5m
2.5m
2.5m
2.5m
2.5m
2.5m
For IR940nm Distances please contact Raytec
Standards:
CE (Covering EMC, Safety, IP rating)
FCC
IEC/EN 62471 (Photobiological Safety)
Page 21
21 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
VARIO2 Troubleshoot :
Ensure all tests are undertaken by a qualified, trained engineer. Ensure safe working practices are followed at all times.
Step 1: Basics
Check polarity of illuminator connection red=+ve, black=-ve
Ensure power is 12-24V AC or DC (For Vario 16 variants : 24V AC or DC
only)
Ensure telemetry wires are shorted out or valid telemetry input (zero volt or TTL) is applied and correctly wired
Check photocell is working. Cover photocell fully, light should turn on if valid telemetry input. It is sometimes difficult to see Infra-Red illuminators working in high brightness conditions.
Ensure power supply is suitably rated to product - check page 19 for specifications
If longer cables used, ensure sufficient voltage is provided to allow for drops across the cable
If OK…
Step 2: Illuminator Test
Check current is being drawn – amount of current will depend on
power setting of unit. Please note – use appropriate multimeter depending on how the unit is being powered (AC or DC)
To test this you must ensure photocell fully covered (or disabled using
optional VARIO remote controller or manual control buttons) and ensure telemetry wires are shorted out or valid telemetry input (zero volt or TTL) is applied and correctly wired
Page 22
22 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Step 3: Set up camera, lens, and illumination
Check model number to Raytec performance specification to ensure required distance is achievable;
- Check unit is set to max power
- Check orientation of unit and ensure it is pointing in correct direction
- Check angle of unit (Interchangeable lens) – Too narrow may cause hot spots and the aperture of the camera lens to close down. Too wide and there may be insufficient light on scene and light going where it is not needed.
Check the LED status indicators for the status of the illuminator. The LED indicators will display differently depending on which mode the illuminator is in (see below)
Programming mode (RHS LED flashes AMBER 1 second on/1 second off)
LHS SOLID GREEN: Power Applied LHS FLASHING GREEN: Remote control IR receiver problem RHS FLASHING AMBER: Indicates unit is in programming mode RHS SOLID AMBER: Indicates that a valid command is being received LHS FLASHING RED: Voltage supply problem detected LHS SOLID RED: Illuminator fault detected
Note: the if there is a voltage supply error, the LHS RED LED will FLASH RED but extinguish and revert to the standard SOLD GREEN when the correct voltage has been restored.
The fault indications are non latching
Page 23
23 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Normal operating mode
LHS SOLID GREEN: Power Applied LHS FLASHING GREEN: Remote control IR received problem (Max VRC
distance is 8m (26ft) LHS FLASHING RED: Voltage supply problem detected LHS SOLID RED: Illuminator LED fault detected
Check unit is responding to remote /Manual Control buttons. If not..
- Status indicators may be turned off. Turn on with remote or with manual
buttons. This can be done even if programming has been disabled
- In extreme sunlight conditions, distance between remote and unit may
need to be reduced
- Programming may be disabled. Enter PIN to retrieve control or RESET
illuminator using one of the two RESET modes.
- Battery failure. Check battery on remote (CR2025). Test 3 volt battery,
replace if necessary. Ensure battery has clean contacts.
- Remote failure. Test with new remote
Step 4: Call Raytec for further assistance Note down:
Model and serial number of illuminator
Camera make and model
Camera Lens make and model
If the Raytec illuminator or remote control is still not delivering the required performance, please contact us for further assistance:
UK / Europe Tel: +44 (0) 1670 520055 Americas Tel: +1 613 270 9990
Raytec Warranty
Please register your Raytec LED Illuminator(s) for its 5 year warranty by visiting www.rayteccctv.com/products/warranty-card
Page 24
24 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Quick Reference Table for Manual Button Operation :
Buttons are accessed by removing the base plate at the bottom of the unit (2 screws)
Action
Required
Step1 :
LHS Button
Step 2 :
RHS Button
LHS
LED
RHS
LED
Comment
Power Adjust
1 x Push
Each Push cycles through power levels
Solid Red
Green flashes indicate level. High power (5 flashes) to Low power (1 flash)
Photocell Adjust
2 x Push
Each Push cycles through photocell levels
Solid Green
Green flashes indicate setting. Low sensitivity to High sensitivity. Solid Red indicates Photocell disabled
Status Indicator LEDS On / Off
3 x Push
Each Push cycles between On and Off
Solid Amber
On – Green Off - Red
Factory Re­set (Does not Re-set PIN)
1 x Long Push (4 Seconds)
Push and Hold until both LEDs flash Amber
Flashing Red – After 4s Flashing Amber
Solid Red – After 4s Flashing Amber
Reverts to Programming Mode unless a PIN is present. If a PIN is present reverts to original mode before re-set
Disable Remote and Enter Operating Mode or Enable Remote and Enter Programming Mode
1 x Long Push (4s) and 1 x short Push
Push to cycle Disable / Enable
Flashing Green
Disable – Red Enable - Green
Reverts to the Mode requested unless a PIN is present. If a PIN is present and you are in Operating Mode you cannot change to Programming Mode
Page 25
25 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Action
Required
Step1 :
LHS Button
Step 2 :
RHS Button
LHS LED
RHS
LED
Comment
Disable / Enable Manual Buttons
1 x Long Push (4s) and 2 x short Push
Push to cycle Disable / Enable
Flashing Amber
Disable – Red Enable - Green
Buttons will be Disabled 30 minutes after this selection is made – This is to allow the user to re-enable manual buttons if required
Full Re-set (including PIN re-set)
Keep both buttons depressed during power up – LEDs will both flash Amber
Keep both buttons depressed during power up – LEDs will both flash Amber
Illuminator will revert to Programming Mode, Full factory default including No PIN
The illuminator has two modes; (1) Programming Mode when the remote control can be used and (2) Operating Mode when most of the remote control functions are disabled (see Remote Control Instructions for more details
Manual Buttons are always available in programming mode or if they have been disabled, they can be enabled in programming mode.
Manual Buttons are available in operating mode, provided they have not already been disabled.
The number of button pushes indicated above are based on the user starting with the illuminator in either programming or operating mode.
If the user has already started to program the units, then the number of button pushes on the left hand will take them to the next function as per the sequence in the table.
If no buttons are pressed within 2 minutes then the illuminator will automatically default back into the previous mode it was in – programming or operating mode.
Page 26
26 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Quick Reference Table for Remote Control Operation for PIN set and Manual Button Disable / Enable :
Most remote control features can only be used/accessed when the illuminator is in programming mode.
The only features of the remote that can be used during operating mode are:
Turn Status Indicator LEDs on/off using "STATUS" Button on remote Enter an existing PIN code Disable manual buttons - but this must be done at the same time as disabling the remote (going into programming mode)
Valid characters for PIN Numbers are: Power 5, Power 1, Min Photocell (Smallest Moon), Max Timer (Full Red Circle), Timer Disable
The unit will NOT accept any invalid characters - and the countdown will not reduce.
If valid characters are entered in the wrong order when entering a PIN , the unit will accept the input and reduce the countdown, but at the end of the countdown the illuminator will stay in operating mode, show an error and the procedure to enter a valid PIN will have to be repeated
Action
Required
Available
Mode
Step1 : LHS
Button
Step 2 : RHS
Button
LHS
LED
RHS
LED
Comment
Disable Remote
Prog Mode
Press <Disable Remote Control> for 4 seconds
N/A
Solid Green
Flashing Amber – Solid Amber
- Off
Right Hand flashing Amber LED will stop RHS LED will go Amber when the button is pressed and turn off when in Operating Mode
Page 27
27 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
Action
Required
Available
Mode
Step1 :LHS
Button
Step 2 : RHS
Button
LHS
LED
RHS
LED
Comment
Disable Manual Buttons
Operatin g Modes
Press <Disable Remote Control> for 4 seconds
N/A
Solid Green – After 4 seconds Flashing Red (Returns to Solid Green after button release)
Off – Solid Amber ­After 4 seconds Flashing Red (Returns to Solid Green after button release)
Must be done within 5 minutes of Disabling remote / entering Operating Mode. Change will take effect after 30 minutes
Create or Change PIN
Prog Mode
Press <Status Button> for 4 seconds
Enter valid PIN character x 4
Green – Intermitte nt Flashing Red / Green ­Green
Solid Amber – Flashing Red counts down the No. of valid characters required – Flashing Amber
Stays in Programming Mode after PIN created or changed
Enter existing PIN
Prog Mode
Press <Status Button> for 4 seconds
Enter valid PIN character x 4
Green – Intermitte nt Flashing Red / Green ­Green
Solid Amber – Flashing Green counts down the No. of characters required – Flashing Amber
Enters Programming Mode after valid PIN entered If invalid PIN entered both LEDs flash red and unit will stay in Operating Mode
Delete PIN
Prog Mode
Press <Status Button> for 4 seconds
Press <Re­Set> button 4 times
Green – Intermitte nt Flashing Red / Green ­Green
Solid Amber – Flashing Red counts down the No. of valid characters required – Flashing Amber
Stays in Programming Mode after PIN deleted
Page 28
28 www.rayteccctv.com Raytec Global Tel : +44(0) 1670 520055
Americas Tel : +1 613 270 9990
VA2/16/10.3