Please forward this information directly to all members of your service department!
Contact problems of edge connectors and bus connections
All thermocouple connections are explicitly excluded from his instruction!
Very often we are getting back pcb which are marked as defective. Quality control has found on some of them, that the contacts of the edge connectors show signs of abrasion and oxidation. This is related to minimal vibrations between the pcb itself and plugs connected to the wire harness.
Rational now offers a contact grease to avoid and correct such effects.
This grease is on
Note:
Repeat grease on the RJ45 connectors
In order to avoid unnecessary changing of electronic components like blower motor etc. we are asking you to use this grease before such major components are changed. Remove the plugs from the pcb and apply some grease (as shown below) before reconnecting them.
Should the error not show problem between plug and pcb. This grease (5
1 portion will be sent with each SCC main pcb, SCC I/O pcb, CM pcb, fan motor SCC line and ignition
With best regards Your RTS Service Team
ed „Service 34.xx“ errors (bus connection) have also been corrected in the past by using this
module SCC line
All Rational units SCC and CM
ly to be used on Rational products (pcb's).
(X51 etc).
the PCB, ignition mod., gas
NOTE: This grease
up again the problem was obviously associated to such a contact
tubes) are available as a service part using number 9003.0219.
is NOT be applied to thermocouple connectors.