Rane SSE 22 User Manual

Rane SSE 22
Stereo Equalizer
11 Bands of 1/3-Octave Graphic Equalization 80 Hz - 800 Hz
2 Bands of Parametric Equalization, sweepable 1 kHz - 10 kHz Center Frequency
Room Control. The SSE 22 provides exact equalization controls for use in correcting room response problems—a critical step in recreating the home theater listening experi­ence.
All rooms differ, and all rooms display acoustical problems of some sort. These anomalies distract from the enjoyment of the true home theater experience. Recording studios equalize their playback, and the same procedure at home yields an uncolored, transparent sound, as heard in the studio. The SSE 22 is also one of the quietest equalizers available at any price. After alignment, pressing the BYPASS switch reveals the before and after. The clarity is obvious.
Surround Equalization. The same combination of graphic and parametric equalization that is so successful in the THX 44 equalizer is duplicated in the SSE 22. Now all channels can deliver even room response, the goal in 5.1 digital systems.
In-Wall Speaker Equalization. In-wall speakers often carry a reputation for not sounding as good as free-standing ones. The SSE 22 can greatly improve the response of in-walls by removing the peaks causing that “boxy” sound. The SSE 22 can compensate for various wall construction techniques, allowing the different channels, free-standing or other in-walls, to match room response better for a more transparent sound.
Remote Speaker Equalization. Any­where in the home where remote speakers are used, regardless of brand or type, equalization makes a difference between sounding good and sounding great.
Graphic and Parametric. The left and right channels feature an 11-band 1/3-octave graphic section for low frequency corrections, plus a 2-band parametric equalizer for high frequencies. The SSE 22 delivers ±6 dB of correction where needed. The parametric bands can provide the broad frequency control occasionally needed in the top end, or notch out a problem frequency peak.
Setup and Alignment. The SSE 22 installs between the preamp/controller and the power amplifiers. Setting the rear channel controls to THX standards requires the temporary use of a 1/3 octave analyzer with averaging. As for the front channels, consult the “Home THX Audio System Room
Equalization Manual” available from the
Lucasfilm THX Division or Rane.
Once set-up, all controls are hidden away behind the power supply and attachable 19" rack mounting ears are also provided.
included
security panel. A low-noise
THX is a registered trademark of Lucasfilm Ltd. Dolby and the double-D symbol are trademarks of Dolby Laboratories Licensing Corporation
Parameter Specification Limit Units Conditions/Comments
Graphic Equalizer Sections: Left & Right
..........Bands (11) 1/3-Octave ISO Spacing From 80 Hz to 800 Hz
..........Type Interpolating Constant-Q Smooth Combining
..........Travel 20 mm Positive Grounded Center Detent
..........Range ±6 0.25 dB
Parametric Equalizer Sections: Left & Right
..........Frequency Range 1 kHz-10 kHz
..........Bandwidth Range 0.7-3.5 octaves (Q=2.0-0.33)
..........Amplitude Range ±6 0.25 dB
Inputs: Type Active Unbalanced RCA Phono Connectors
..........Impedance 10k 1% ohms
..........Maximum Level 34.5 1 dBr 11 Volts peak
Outputs: Type Active Unbalanced RCA Phono Connectors
..........Impedance 50 1% ohms
..........Maximum Level +34.5 > = 2k ohm 1 dBr 11 Volts peak
Frequency Response 20 Hz-20 kHz +0/-.2 dB Group Delay Linear (Minimum Phase) ±5° 20-20 kHz THD+Noise 0.001 .0005 % 1 kHz, +27.5 dBr (5 V peak) Signal-to-Noise 120 1 dB re 5 V pk; A-wtg; input short; flat
-92.5 1 dBr A-wtg; input short, flat
-90.5 1 dBr 20 kHz BW; input short, flat
-84.5 1 dBr A-wtg; input short, full boost
-87.5 1 dBr A-wtg; input short, full cut Dynamic Range 127 1 dB Max out/noise floor (+34.5dBr/-92.5dBr) Channel Separation 90 min dB 20-20 kHz Unit: Agency Listing
..........120 VAC model Class 2 Equipment National Electrical Code
UL 813 Exempt Class 2 CSA Exempt Class 2
..........230 VAC model VDE, SELV Safety Extra Low Voltage
CE-EMC EMC directive 89/336/EEC
CE-Safety Exempt Article 1 of LV Directive 73/23/EEC Power Supply: Agency Listing Class 2 Equipment
..........120 VAC model UL listed File no. E88261
CSA Certified File no. LR58948
..........230 VAC model CE-EMC Meets EMC Directive 89/336/EEC
CE-Safety LV Directive 73/23/EEC Power Supply: Input 18 VAC w/center tap 10% Vrms Model RS 1
..........Current 750 max mA RMS Current From Remote Supply
Unit: Size 1.75"H x 19"W x 8.5"D (2U) (4.4 cm x 48.3 cm x 21.6 cm)
17 3/8" wide w/o rack ears (44.2 cm wide without rack ears)
..........Weight 5 lb (2.3 kg)
Shipping: Size 4.25" x 20.3" x 13.75" (11 cm x 52 cm x 35 cm)
..........Weight 8 lb (3.6 kg)
Note: 0 dBr=150 mVrms=Home THX Equalizer Reference Level
©Rane Corporation 10802 47th Ave. W., Mukilteo WA 98275-5098 TEL (425)355-6000 FAX (425)347-7757 WEB http://www.rane.com
All features & specifications subject to change without notice. 08235 NOV97Printed in the U.S.A. on Recycled Paper