Rane RPM 2 User Manual

Page 1
HARDWARE MANUAL
PROGRAMMABLE
MULTIPROCESSOR
INPUT OUTPUT
1 2
1 2
VIP POWER
ETHERNET STATUS
RPM 2
PRESET
QUICK START
is section is intended to help you make the physical con­nections and software manipulations necessary to get up and running with your sleek new RPM 2. If you don’t read the entire Hardware Manual, at least read this section. It is also recom­mended that you read the Quick Start section of the Drag Net Software Manual. If the Drag Net software is not yet installed on your computer, please install it now.
To be safe, leave the audio connections until last. Begin by connecting the IEC power cord. Observe that the POWER LED on the front panel illuminates. After a few seconds, the STATUS LED should turn from red to yellow to green, and the PRESET display should have a number in it (00, if it’s the first time you’ve powered the device). If the POWER comes on, but the STATUS LED does not turn green, contact the factory.
Connect one end of the Ethernet crossover cable (supplied with the unit) to the 10Base-T jack on the rear panel. Connect the other end of the cable to an Ethernet port on your computer. e LINK LED on the rear panel should be lit. If it is not, verify that you are indeed using a crossover cable, not a stan­dard Ethernet cable. Only use a standard Ethernet cable if you are connecting the RPM 2 and a computer indirectly using an Ethernet switch. Launch the Drag Net application and follow the steps to create a new project and new RPM 2 device configu­ration. Click the Congure Hardware IP shortcut and follow the instructions to set the unit’s IP address to be compatible with your computer’s Network settings. Tip: If you aren't sure what IP
to use, try the address 192.168.69.69 and subnet 255.255.255.0. is finds the default factory address without manually setting it.
RPM 2
PROGRAM MABLE MULTIPROCESSOR
Now click the Poll button in the toolbar. A device name and
IP address should appear under the Live folder in the Project window. If a device does not appear, consult Drag Net’s online Help for instructions on configuring and verifying your comput­er’s Network settings.
e audio path within the RPM 2 is displayed in Drag Net’s
Device Conguration window as a collection of blocks wired together to form a Processing Map. ese maps are created offline as Storage configurations, which are then transferred to a Live unit. Drag blocks from the Palette onto the Process- ing Map and wire them together to create the audio path. Save this file frequently using the File > Save command. Transfer the selected Storage configuration to a Live unit using the Transfer Cong button in the Project window. A new, minty green Device Conguration window opens once the transfer is complete, indicating you are now online with a Live device. Double-click a processing block to display and adjust its Prop- erties (parameters) in real time on a Live device — there is no need to go offline to make parameter changes.
Once you have a useful configuration in the unit, connect balanced audio INPUTS and OUTPUTS to the Euroblocks on the rear panel, then turn on the amplifier. As a precautionary measure, all outputs are muted during and after a configuration transfer. Unmute each output individually, or use the handy Mute Outputs button in the toolbar. Once all outputs are unmuted, audio passes through the unit along the connections you defined.
WEAR PARTS: is product contains no wear parts.
Manual-1
Page 2
Front Panel Description
PROGRAMMABLE
MULTIPROCESSOR
INPUT OUTPUT
1 2
1 2
VIP POWER
ETHERNET STATUS
RPM 2
1 1 2 3 4 5 6
PRESET
RPM 2
ACN 001 345 482
DEFAULT
100-240V
20 WATTS 50/60 Hz
COMMERCIAL AUDIO
EQUIPMENT 24TJ
MADE IN U.S.A. RANE CORP.
10Base-T
LINK
OUTPUTS
+5V 100 mA
0-5V
VERSATILE INPUT PORT
REF
1 2 3 4 5 7 6 8
GND
REF
1 2 3 4 5 7 6 8
GND
– + + –
– + + –
– + + –
– + + –
THIS DEVICE COMPLIES WITH PART 15 OF THE
FCC RULES FOR A
CLASS 'B'
COMPUTING
DEVICE.
INPUTS
2 1 2 1
LAN
FOR CONTINUED GROUNDING PROTECTION DO NOT REMOVE SCREW
R
1 7 6 4 3 25
1 Signal/Overload LED meters indicate the presence of significant audio signal or overload for Inputs and Outputs. ese 3-color
meters indicate the available headroom once the analog signal has been converted to digital: -4 dBFS (red, near clipping), -12 dBFS (yellow, high normal level), and -48 dBFS (green, low level). e signal level in the RPM 2 depends on the input and output settings and is displayed in Drag Net’s Meter window when the Converters tab is selected.
2 PRESET LED displays the number of the most recently recalled Preset, numbered 0 through 24.
3 VIP LED flashes when a change is detected on the Versatile Input Port (VIP). is port is used for direct electrical connections to
potentiometers, switches or other logic ports. See page Manual-4 for details.
4 ETHERNET LED flashes when an Ethernet data packet for this device is received.
5 STATUS LED reflects the overall status of the unit:
Red - initializing (briefly) or possible internal error. Yellow - working, but not yet processing audio. Green - processing audio.
6 POWER LED lights solidly when the unit is powered on.
Rear Panel Description
1 POWER IEC jack connects to AC line voltage, 100-240 VAC ±10%.
2 Balanced analog audio INPUTS 1 and 2 on Euroblock connectors. See “Audio Connections” on the next page.
3 Balanced analog audio OUTPUTS 1 and 2 on Euroblock connectors.
4 VERSATILE INPUT PORT provides 8 logic or voltage inputs for remote level control and Preset recall on a Euroblock.
5 LAN and LINK reflect the state of the Ethernet connection. LINK lights solidly when a valid connection to another Ethernet
device (e.g., a PC) is detected. LAN flashes when communicating with another Ethernet device.
6 10Base-T jack accepts a standard Ethernet cable with a RJ-45 connector.
7 DEFAULT button recalls Preset 1 when pressed. Holding this button while applying power puts the unit into a special codeload
mode for updating firmware.
Manual-2
Page 3
Audio Connections
As a safety precaution, turn all devices (especially power amplifi­ers) OFF when making connections. Doing so gives you a chance to find and correct wiring mistakes and prevent damage to your amplifiers, speakers, ears, pets, etc.
Analog Inputs and Outputs
e RPM 2 has two balanced analog Inputs and two bal-
anced analog Outputs.
For each Input or Output Euroblock connector:
• Connect the (positive) audio line to the ‘+’ terminal.
• Connect the (negative) audio line to the ‘–’ terminal.
• Connect the cable shield to the shield terminal. For those installations where the RPM 2’s internal shield-
to-chassis connection causes interference, connect each shield directly to the chassis PEM nut located above each Euroblock connector, keeping the shield wrapped around the audio conduc­tors as much as possible.
For optimum Electromagnetic Interference (EMI) immunity,
connect the shields at both ends of the cable. See the RaneNote “Sound System Interconnection” for more information on system connections and proper grounding practices.
Analog Input Stage
Each analog input uses a fixed analog gain approach. A Digital Trim control is located immediately after the A/D converter. e RPM 2 takes the following approach to input clipping:
e analog input stage accepts a full level of +24 dBu. It
is not possible to clip the A/D converter with normal audio sources, since there is no additional gain between the initial input stage and the A/D converter. e Digital Trim control, located after the A/D converter, can be set to clip the signal to your heart’s content, so adjusting this trim to provide the hottest signal to the DSPs without clipping is the most important step when setting up gain structure. For this reason, a dedicated meter displaying the signal level being passed to the DSPs is provided in each Analog Input block.
If the DSPs are working with a clipped signal, the audio is (as
expected) distorted and none too pretty, but it is not a drastic, damaging sound. And while it’s technically possible to write a DSP algorithm to emulate the glorious clipping distortion of vacuum tubes, it’s not particularly useful for an installed sound system, where the DSP power could be put to better use remov­ing that annoying 500 Hz feedback from the podium mic. Plus, they don’t yet make DSP chips with gold-plated substrates for those celestial highs and that moist, supple midrange.
Analog Output Stage
Each analog output uses a similar approach. ere is a Digital Trim control located immediately before the D/A converter. It’s as simple as that.
Control Connections
Versatile Input Port (VIP)
Eight logic input pins are provided, each capable of accepting DC voltage between 0-5 VDC. VIP pins are used with contact closure switches for Preset recall, or with potentiometers for remote Level control. e functionality (Preset recall versus control) of each pin is assignable as part of the Device Configu­ration.
• e maximum allowable voltage on any VIP pin is 5.3 VDC.
• Use of twisted pair cable is recommended for lower noise.
• If an external device is used to generate a 0 to 5 volt signal, connect the ground of the external device to the VIP GND.
Preset Recall Using Contact Closure Switches
e minimum “low” voltage required to detect a contact closure and change Presets is 2.5 V. Since the internal pull up is 100 kΩ to +5 V, it is possible to calculate the maximum allowable cable length, provided the wire resistance per foot (or meter) is known.
Example:
To be safe, let’s allow a maximum of 80 kΩ worth of cable resistance. is value keeps the voltage divider formed by the 100 kΩ internal resistance and 80 kΩ cable resistance from dropping below 2.5 V.
(5 V * 100 kΩ) / (100 kΩ + 80 kΩ) = 2.777 V
If the cable resistance is 30 Ω per 1,000 feet (305 meters)
(1,000 ft / 30 Ω) * 80,000 Ω = 2,666,666 ft (813 km)
us, you can only use 2,666,666 feet (505 miles) of twisted pair cable before the Preset recall functionality becomes inter­mittent (assuming the cable is properly twisted and not run through excessive magnetic or electric fields).
Remote Level Control Using Potentiometers
e VIP inherently prefers linear taper 10 kΩ potentiometers, which provide a nice audio taper “feel” for the end user. When used with suitable twisted pair wiring, the 10 kΩ value also of­fers acceptable noise immunity and long cable lengths.
AMX and Crestron Control
ere are two ways to control a Drag Net device from an AMX or Crestron system. Use either Ethernet connectivity or use the rear panel Versatile Input Port (VIP). Each of the 8 VIP pins supports either switch closure Preset recall or zero-to-five volt control of Level.
Many AMX/Crestron applications require simple Level con­trol and/or Preset recall. is is most easily accomplished using the VIP (Versatile Input Port) found on all Drag Net devices. ere are always more Drag Net products coming — both hard­ware and software, so check our home page for the most recent.
VIP Preset Recall
Connect a switch closure or relay to a VIP pin and short it to the ground (GND) pin to recall the corresponding Preset. For example, shorting VIP pin 1 to the GND terminal recalls Preset 1; pin 2 recalls Preset 2, etc. ere are more details about this functionality in the Drag Net Help file and on our Drag Net Ap­plications page. Be certain to appropriately set the VIP Alloca­tion in Drag Net's Parameter Window.
Manual-3
Page 4
If GND contention of two or more pins simultaneously
pin 1
GND
Contact
Closure
20 kΩ (linear)
Level Control
Potentiometer
VIP CONNECTION
(examples for VIP pin 1)
GND
REF
pin 1
occurs, the highest-numbered VIP pin takes precedence. For example, if pin 3 is shorted to GND and pin 6 is then shorted to GND, Preset 6 is recalled. If pin 3 is closed and then pin 2, nothing happens -- Preset 2 is not recalled. is permits a hier­archy of Presets when using VIP pin closures for tiered priority paging. Since there are only eight VIP pins, you can only recall up to eight Presets using switch closures.
ere are two ways to recall more than eight presets. Either use the Drag Net software Recall button which is only intended for the system installer/designer, or use an Ethernet command from an AMX or Crestron Ethernet-equipped product.
[When using Drag Net's Auto Mixer/Ducker block, you have the ability to link a VIP pin closure to a push-to-talk switch in a paging or boardroom application. When using the Ducker block in these applications, the VIP pins act independently provided you Group the appropriate VIP pin with the Auto Mixer/Duck­er's Input in Drag Net's Remote Map. Again, see our Drag Net Applications for examples.]
VIP Level control
Connect a zero to five volt DC voltage to a VIP pin from an AMX or Crestron card to adjust any or all Level blocks placed in the Processing Map. Use Groups in Drag Net's Remote Map to link one or more Level blocks so they track each other when us­ing a VIP pin. Be certain to appropriately set the VIP Allocation in Drag Net's Parameter Window. When using VIP pins with Level blocks, set the minimum and maximum for each Level block by double-clicking it while it's in a Remote Map Group. is keeps the max and min burdens within the Drag Net device — but only when using the VIP pin to control Levels, not when adjusting Levels from Ethernet commands.
You can use up to eight voltage control inputs linked to Level(s) using the rear panel VIP pins. Combinations of Preset switches & voltage Level “pots” are possible as long as combined, they do not exceed the eight pins provided.
Since you can Group any or all Level blocks in Drag Net's Remote Map, it's much easier to implement a stereo level control since the Drag Net device is burdened with the task of tracking many Levels. You can use this to your advantage when using VIP pins to adjust multiple zones or levels. Since you can place the Level block anywhere within the Drag Net Processing Map, you can Group Level blocks at the input, at the output or anywhere in-between — just place the Level block where you want it.
Ethernet Port
e Ethernet port is used to configure, monitor, and control the RPM 2 via standard 10Base-T Ethernet communication. Use an Ethernet crossover cable (one is included with each unit) to connect the RPM 2 directly to a computer. Use a standard (non-crossover) Ethernet cable if the RPM 2 and computer are connected indirectly using an Ethernet switch.
All devices connected to the Ethernet port, including switches and the computer’s Network Interface Card (NIC) must support 10Base-T communication..
Ethernet control
To download the AMX or Crestron control code and documen­tation, visit these web pages:
For AMX NetLinx code:
www.rane.com/dnamx.html
For Crestron code:
www.rane.com/dncrestron.html
©Rane Corporation 10802 47th Ave. W., Mukilteo WA 98275-5098 USA TEL 425-355-6000 FAX 425-347-7757 WEB www.rane.com
Manual-4
107207
Loading...