RAIN BIRD Simple To Set Timer New installation Guide

What is an Automatic Sprinkler System?
G
1
What will you need?
2
Supplies not included with timer
• Valve Control wire; for new systems
18 gauge color coded, multi-strand, direct-burial wire for runs less than 800 feet; 14 gauge for runs greater than 800 feet
Mounting your Timer to the wall
3
Wiring with Conduit
4
Below is a typical outdoor hard wired installation using electrical conduit. Check with your local building department or a licensed electrical contractor for assistance.
W
A
T
E
W
A
T
E
R
I
N
G
T
I
M
E
S
P
E
R
D
A
Y
S
AM
Current Time
R
D
A
Y
Simple To Set Timer New Installation Guide
In the interest of product improvement, Rain Bird reserves the right to change product design or specifi cations without notifi cation.
®Trademark of Rain Bird Corporation. © 2008 Rain Bird Corporation.
Rain Bird Corporation Consumer Products Division Customer Service Center 6991 E. Southpoint Rd. Building #1 Tucson, AZ 85706
1-800-RAIN BIRD
Connecting the Valve Wires: Common
5a
Common Wire Connection
Connect one wire from each valve together with watertight
1
splice connectors; either valve wire will work.
2
Connect all wires to common terminals on timer.
The SST Series Timers can be used with most hydro-indexing valves. Please
STOP
contact the valve manufacturer for more information. DO NOT connect more than one valve wire to each terminal. Wiring more than one valve to each terminal will damage the timer. Also, if you are using more than one timer, do not share “common” wires between them.
USER TIP:
short circuits.
Use watertight splice connectors to prevent corrosion and avoid
1
2
3
4
STOP
637699-01, Rev 10/08
5b
1
2
Zone 1
4
Zone 2
4
Timer
Valve Control Wiring
Valves
Sprinkler Zone
(Number of Zones vary by Timer Model)
The SST Timer can be mounted INDOOR or OUTDOOR.
Connecting the Valve Wires: Control
Control Wire Connection
Connect the second wire on each valve to a wire on the control cable; connect only one valve to each wire.
Connect the other end of the wire to the desired zone on the Timer (1,2,3, etc.).
(Each numbered zone corresponds to the same number zone when programming timer)
• Water tight splice connectors (gel caps)
• Drywall anchors; optional
• ¾" or 1" PVC electrical conduit; optional
Tools you will need to install timer
• Phillips screwdriver
• Wire strippers
• Hammer
Connecting Rain Sensor
6
Included only on select models
1
Remove the jumper wire from the Rain Sensor terminals.
Connect both Rain Delay Sensor wires to the terminals marked
2
RAIN SENSOR.
RAIN & TEMP
MSTR
ZONE3ZONE
ZONE
ZONE5ZONE
ZONE
COMMON
SENSOR
VALVE
4
2
1
Do not remove
wire unless
installing
Rain Sensor
If you decide not to use a Rain Sensor with the timer, leave the wire jumper in place that connects the 2 terminals; timer will not work if
STOP
wire jumper is removed and sensor is not connected.
USER TIP:
A rain sensor measures rainfall and prevents unnecessary watering.
To save water and money, you can also install a rain sensor.
SYSTEM RESET
W
A
T
E
R
A
L
L
N
O
W
W
A
T
E
R
1
Z
O
N
E
N
O
W
L
C
T
A
U
T
O
R
U
N
L
C
T
Z
O
N
N
D
I
A
L
F
I
R
T
O
N
D
I
A
L
F
I
R
SERIAL NO.
DATE CODE
T
RAIN & TEMP
MSTR
ZONE
ZONE2ZONE
ZONE5ZONE
ZONE
COMMON
SENSOR
VALVE
4
3
6
1
Choosing Timer location
Locate a spot for your Timer.
Locate Timer so that it is convenient to run control wires.
A
Y
W
A
T
E
R
I
N
D
A
Y
S
Power connection using
included power cord
Plug into any Outdoor
Electrical Outlet
110 VAC
power wire
J-Box
Controller wire
DO NOT plug in until you have completed and checked all
STOP
wiring connections.
Master Valve or Pump Start Relay
8
Connect the color-coded “hot”
1
wire from the Master Valve or Pump Start Relay to the Timer terminal marked MASTER (MSTR) VALVE.
Connect the common wire
2
from the Master Valve or Pump Start Relay to the common wire coming from the station valves. This wire connects to the Timer terminal marked COMMON.
To avoid possible pump damage,
3
connect a short “jumper” wire from any unused station terminal(s) to the nearest terminal screw in use. For example, if you have a 6-station timer with only 4 stations in use, route stations 5–6 to the nearest active station (in this case, 4).
SST Timers allow a master valve or
STOP
pump start relay to operate whenever a valve is operating (pumps are used in some places to draw water from a well or other source).
If you are activating a pump from the Timer, you must also install a Pump Control Relay.
in conduit
This example shows what a Master
e
Valve connection would look like. A Pump Start Relay would connect differently at the water source
USER TIP:
total draw of the Master Valve or Pump Start Relay plus the draw of the valve does not exceed 0.650 Amps at 24 VAC, 60 Hz.
This Timer does not provide the main power for a pump.
Make sure that the
Water Source
If using attached power cord, locate timer within 5 feet of an AC
power outlet.
Locate Timer at least 15 feet away from major appliances
and air conditioners.
Mounting Timer to wall
Drive a screw into the wall,
1
leaving 1/8” gap between head and wall. (May also use supplied wall anchors if necessary)
2
Hang Timer on exposed screw.
3
Remove access cover at bottom of Timer and drive a screw through the center hole into wall.
System Check Out
7
Current Time
SYSTEM RESET
W
A
T
E
R
A
L
L
N
S
E
L
E
C
T
A
U
T
O O
N
D
I
A
SERIAL NO.
DATE CODE
L
RAIN & TEMP
SENSOR
W
A
T
E
R
W
A
T
E
R
I
N
G
T
I
M
E
S
P
E
R
D
D
A
Y
S
AM
O
W
W
A
T
E
R
1
Z
O
N
E
N
O
W
R
U
N
S
E
L
E
C
T
Z
O
N
E F
I
R
S
T
O
N
D
I
A
L
F
I
R
S
T
MSTR
ZONE
ZONE
ZONE
ZONE
ZONE
ZONE
COMMON
VALVE
3
4
2
5
6
1
To make sure each system is functioning properly, cycle through each ZONE using the WATER 1 ZONE NOW feature:
Turn the dial to the
1
6
ZONE you wish to test and press WATER 1 ZONE NOW.
2
The ZONE will start watering for a default 10 minutes.
3
Use the Up/Down arrows to adjust the time.
4
To stop watering before the time is up, turn dial Auto Run.
5
Repeat on next ZONE until all have been checked.
Start Time
WATER ALL NOW
S
E
L
E
C
T
A
U
T
O
R
U
N
O
N
D
IA
L
F
I
R
S
T
desired ZONE
ZONE NOW
W
AT
E
R
1 ZO
S
O
Set dial to
and press
WATER 1
N
E N
O
W
E
L
E
C
T
Z
O
N
E
N
D
I
A
L
F
I
R
S
T
Loading...