Rain Bird RAIN CLOCK PC-104, RAIN CLOCK PC-104-PS, RAIN CLOCK PC-106, RAIN CLOCK PC-106-PS Owner's Manual

RAIN CLOCK
OWNERS MANUAL
SPRINKLER SYSTEM CONTROLLER
PC-104 4 Station PC-106 6 Station
PC-104-PS 4 Station with Pump Relay
PC-106-PS 6 Station with Pump Relay
6991 E. Southpoint Rd., Bldg. #1, Tucson, AZ 85706
RAIN CLOCK MODELS
Circuit
Circuit
Customer Support Center
1
Special Upgrade Oer
Save an extra 15% o new sprinkler timers and
irrigation controllers at the Rain Bird Online Store.*
Still struggling with your old sprinkler timer? Having a hard time complying with local watering restrictions? Upgrading to a new Rain Bird sprinkler timer is easier than you might think.
New timers are easier to program than ever before, with powerful features to help save you time and water while keeping your yard healthy and vibrant.
There are lots of models to meet your needs, including indoor and outdoor versions, exible modular timers and even smart controllers that automatically adjust themselves based on the weather.
Shop Now at store.rainbird.com and enjoy exclusive upgrade savings!
UPGRADE15
at checkout to save an extra 15% o*
* Additional discount not valid on clearance items, bundles or store specials.
Discount applies to controller products only. Cannot be combined with
other store discount codes. Valid at the Rain Bird Online Store only.
Enter discount code:
Subject to change without notice.
® Registered trademark of Rain Bird Corporation.
PC-104/106 SPRINKLER SYSTEM CONTROLLER
INSTALLATION INSTRUCTIONS
Rain Bird Rain Clocks are designed for use with all standard residential 24 volt AC electric valves regardless of brand. However, some older brass elec­tric valves and commercial duty plastic valves may have power requirements higher than this series is designed for
STEP 1: MOUNT THE TIMER
Location: Select a location inside a building,
Lift
and within six feet of a grounded electrical outlet. This is not an outdoor timer. Do not mount it where it is exposed to any of na­tures elements. If it must be outside, be sure to use an outdoor enclosure and a weatherproof electrical connection.
Cover Removal: Remove the front cover of the timer by depressing the bottom tab and
Press Here
FIGURE 1
lifting as shown in Figure 1. Mounting: Mount the timer to a wall using two #10 screws installed at centers
3 13/16" apart at eye level. Use plastic anchors to secure screws if the wall is plastic or masonry. Leave the screw heads extended ¼ " and hang the Rain Clock using the keyhole slots on the back. Install a third screw through the mounting hole (located below the battery area) to secure the timer to the wall.
Mounting Holes
FUSE
1
/2A 250V 3AG
OR
FUSE
3
/4A 250V 3AG
AS INDICATED ON THE UNIT
Plug Transformer into 120 volt AC electrical outlet
YELLOW
RED
BLUE
Key Pad
Station
Output
Terminals
1
2
3
4
5
6
MV
ONLY ON SIX STATION MODELS
ONLY ON PUMP START MASTER VALVE MODELS
Mounting Hole
ATTENTION
Battery must be installed
!
to ensure proper operation.
9 Volt Battery
2
To
Control
Valves
FIGURE 2
STEP 2: CONNECTING THE WIRING
How to choose the ri ght type of sprinkler wire: Use 18-gauge “bell,” “thermostat” or “underground burial” wire for the sprinkling system. “Bell wire” is available in single strands or twisted in 2 or 3 wire sets and can only be used indoors. “Thermostat wire,” the most common sprinkling system wire, is typically available with up to 7 wires twisted inside a brown PVC jacket (about ¼” in diameter), and is suitable for most indoor and conduit installations. “Direct Burial” cable is similar to thermostat wire, except the jacket is made of a black Poly UV resistant material, and is suitable for any indoor or outdoor installation, including sunlight exposure. Each individual wire is color-coded.
Note: Some areas require by code the use of UL approved cable only. Most Direct Burial Cables have this approval. Most thermostat and bell wires do not. Important: 18 gauge wire or /larger is recommended for sprinkler system wire, allowing cable to be run up to 600’ without problems. Some thermostat wire that is referred to as “sprinkler wire” may actually be a smaller gauge (#19 or #20) and will not have the UL listing or the capacity to run long distances.
The number of wires needed is determined by the number of valves being wired, plus a common wire. For example, three valves in a grouping require a 4-wire cable since the 4th wire serves as the common wire. If a system had two valves in the front yard, and four in the back, the wiring could be run in one of two ways:
1) Use a single run or 18/7 (18 gauge, 7 wires) cable connected ‘in-series’ from the front valves to the back valves to the timer;
2) Use one run of 18/3 cable from the timer to the front valves, and one run of 18/5 cable from the timer to the back valves.
All wiring connections should be sealed with a water-tight connector. Cables that are run indoors should be properly secured with a staple or clip.
How to connect the valves: Each valve connects to the timer through two wires. One wire from each valve solenoid must connect to the output terminal of the timer. This is the “HOT” connection. The second wire of each solenoid must connect to the (COM.) common terminal of the timer. This is the “COMMON” connection. If the valves are grouped together, it is easier to join the common from all valves and just run one wire to the timer’s (COM.) com­mon terminal.
Note: Only one valve may be connected to each station output terminal.
3