The TitraMaster 85 is a Windows-based PC program dedicated for
use with any of the new range of workstations from Radiometer
Analytical.
TitraMaster 85 exists in 4 versions:
•TitraMaster 85 Data Collector,
•TitraMaster 85 Data Collector FDA21CFR/11,
•TitraMaster 85 Bi-directional,
•TitraMaster 85 Bi-directional FDA21CFR/11.
With the Data collector function, the analysis is edited and
started from the workstation. Measurements are collected,
displayed and saved by TitraMaster 85 . The Data Collector
version of TitraMaster 85 can be used with the following
workstations: ION450, ION570, TIM850, TIM854, TIM855,
TIM856, TIM860, TIM865, TIM870 and TIM880.
Concerning the ION450 and ION570, all methods except the EC/
pH Measurement method (pH and conductivity measurements
performed simultaneously) can be run and the curves collected by
TitraMaster 85.
With the Bi-directional function, the application is created,
edited and started from the PC and TitraMaster 85 . On starting
an application, this application is exported from the PC to the
workstation. Then, TitraMaster 85 works as the Data Collector
version: measurements are collected, displayed and saved by the
software. The Bi-directional version of TitraMaster 85 can be
used with the following workstations: TIM850, TIM854, TIM855,
TIM856, TIM860, TIM865, TIM870 and TIM880.
TitraMaster 85 automatically records all data obtained on up to 7
units interfaced via a single standard serial or USB PC com port.
TitraMaster 85 is a powerful data archiving tool, which enables
you to access your stored results and curves in a flash via userprogrammable requests. You can consult the dedicated analytical
database and filter and sort the archived results by date, method
type etc. providing the information you need at a glance.
oductionoduction
oduction
oductionoduction
3
The TitraMaster 85 FDA21CFR/11 version offers all the
necessary features to make your laboratory fulfil its obligations
regarding the FDA21CFR/11 standard requested by the Food and
Drug Administration. It means:
•An encrypted login and password of at least 6 characters
each saved in a secure database.
•3 hierarchical levels of user profiles.
•Fully traceable of results records.
•Totally secure result database for both archiving and restoring
operations.
•Password protection before validation of any changes.
•Electronic signature for record certification and application
certifications.
•Export of signed records in read-only format.
•Event viewer reporting all operations performed by operators
using the software.
This Getting started instructions are common to all TitraMaster 85
versions. If you are using a FDA21CFR/11 version, please read
the important chapter starting on the next page, otherwise skip to
chapter “Minimum configuration recommended”.
Take advantage of new features and product updates by visiting
the Radiometer Analytical
www.titration.com Resource Centre.
4
Notes to PCNotes to PC
Notes to PC
Notes to PCNotes to PC
AdministratorAdministrator
Administrator
AdministratorAdministrator
This chapter deals with the FDA21CFR/11 versions of TitraMaster 85.
Under Windows 2000 Pro or XP Pro, all the TitraMaster 85
application files are secured automatically when installing the
application and this for any user profiles apart from the PC
administrator or a user "With power". Therefore, it is required to
use one of these two recent operating systems.
The PC Administrator must follow some rules in order to totally
secure the TitraMaster 85 installation directory. If these rules are
fulfilled, the PC Administrator will be the only person able to
modify, handle or delete the TitraMaster 85 files.
1. The PC Administrator installs TitraMaster 85 on a local disk
with a NTFS file system.
2. The PC Administrator decides which users can use
TitraMaster 85 then creates a “User” account for each user in
Windows. The “User” level means a person that can only read
the files within the Windows Operating System.
3. Before starting TitraMaster 85, logon in Windows to one of
the users created in step 2.
To XP Pro Windows users:
Do not open more than one TitraMaster 85 application as 2
TitraMaster 85 applications cannot run simultaneously on the
same computer.
4. The directories or discs used for saving or exporting
TitraMaster 85 files must be configured as read-only
directories or discs (and must have an NTFS file system).
Note
TitraMaster 85 with network accesses (examples: database
archiving and analyse exportation to a network disk,...) must be
configurated by the PC Administrator.
Contact us at Radiometer Analytical SAS for more information.
5
Minimum configurationMinimum configuration
Minimum configuration
Minimum configurationMinimum configuration
rr
ecommendedecommended
r
ecommended
rr
ecommendedecommended
1 workstation only1 workstation only
1 workstation only
1 workstation only1 workstation only
Operating system: W2000 Pro (SP2) or XP Pro (SP2).
Internet Explorer version 6.0 or higher must be installed on your PC.
•Pentium 1 GHz processor or equivalent, 256 MB RAM,
•SVGA 1024 x 768 screen resolution, 17" colour screen display,
•1 available serial port or 1 available USB port with 1 USB to
serial converter,
•1 CD-ROM drive,
•1 PS2 or USB mouse type,
•1 Windows compatible printer (optional),
•Hard disk, 150 MB of free space for software installation.
1 GB required for proper use with your database.
2 to 7 workstations2 to 7 workstations
2 to 7 workstations
2 to 7 workstations2 to 7 workstations
Operating system: W2000 Pro (SP2) or XP Pro (SP2).
Internet Explorer version 6.0 or higher must be installed on your PC.
•Pentium 2 GHz processor or equivalent, 512 MB RAM,
•SVGA 1024 x 768 screen resolution, 19" colour screen display,
•1 available serial port or 1 available USB port with 1 USB to
serial converter,
•1 CD-ROM drive,
•1 PS2 or USB mouse type,
•1 Windows compatible printer,
•Hard disk, 150 MB of free space for software installation.
1 GB required for proper use with your database.
TitraMaster 85 FDA21CFR/11 versions, 1 to 7 workstationsTitraMaster 85 FDA21CFR/11 versions, 1 to 7 workstations
TitraMaster 85 FDA21CFR/11 versions, 1 to 7 workstations
TitraMaster 85 FDA21CFR/11 versions, 1 to 7 workstationsTitraMaster 85 FDA21CFR/11 versions, 1 to 7 workstations
Same configuration as for 2 to 7 workstations with:
If you want to install an update version of TitraMaster 85, first
backup your database, uninstall TitraMaster 85 and remove
manually the corresponding installation directory. Install the
TitraMaster 85 full version then restore the database.
Proceed as follows to backup your files:
1. In TitraMaster 85, select File > General setup.
2. Click the Database tab then click the Archive icon.
3. In the Save As window, select the backup file destination
folder and type a name for the backup file (DBZ file).
4. Click Save to close the Save As window.
5. Click OK to close the General setup window.
Quit TitraMaster 85.
To restore a database, consult the TitraMaster 85 help, topics
"Handling the result database/Restoring a database".
Update version frUpdate version fr
Update version fr
Update version frUpdate version fr
Use the TitraMaster 85 Upgrade CD-ROM or a file downloaded
from the TitraLab Resource Centre. It will automatically upgrade
your installed version.
We recommend you to backup your database before upgrading
TitraMaster 85.
om V1.x.xom V1.x.x
om V1.x.x
om V1.x.xom V1.x.x
om V2.x.xom V2.x.x
om V2.x.x
om V2.x.xom V2.x.x
7
BeforBefor
Befor
BeforBefor
Refer to system requirements and make sure that your PC
complies with the minimum configuration recommended (see
previous chapter).
Internet Explorer 6.0 or higher must be installed on your PC.
If you have a French or an English Internet Explorer, Internet
Explorer 6.0 can be installed from the TitraMaster 85 CD-ROM as
follows:
1. In Windows, click
2. Click the Add new Programs then CD or Floppy buttons.
3. Browse the CD-ROM to search for this file:
4. Close all application windows.
5. Run the ie6setup.exe file.
6. At end of installation, switch the computer Off then On.
For TitraMaster 85 FDA21CFR/11 users:
TitraMaster 85 is installed by the PC Administrator on a local disk
with NTFS file system.
TitraMaster 85 must be installed into a directory of the local disc
and not into the root directory. Select preferably the installation
directory proposed by default.
The TitraMaster 85 installation program creates in a Windows
user group, a user account called TM85USER having the “With
power” access rules. Do not modify the access rules of this user.
Do not delete this user: if you delete TM85USER, you will have to
uninstall then re-install TitraMaster 85.
TM85USER is using the TitraMaster 85 application to access disc
in Read/Write mode irrespective of the user’s rights of the
operator logged on Windows. If you (PC administrator) need to
give additional rights to TM85USER (example: access to a
network printer), please contact Radiometer Analytical SAS.
e stare star
e star
e stare star
Programs
/ie6setup.exe (Internet Explorer in English)
/ie6fr/ie6setup.exe (Internet Explorer in French)
ting installationting installation
ting installation
ting installationting installation
Start\Settings\Control panel\Add/Remove
.
8
Installation prInstallation pr
Installation pr
Installation prInstallation pr
1. Close all applications and disable your antivirus application.
2. Insert the CD-ROM into the CD-ROM drive. Installation starts
automatically (AUTORUN). If it does not, use your Windows
Explorer to locate Setup.exe and run it.
3. Select the language of the installation software.
4. Click OK (information message about languages) then Next.
Installation starts with the Welcome dialogue box. Click Next.
5. Accept the License agreement and click the Next button.
6. In the Customer information dialogue box, enter your name,
the name of your company and the TitraMaster 85 serial
number indicated on a label in the TitraMaster 85 CD-ROM
box (xxxVxxxNxxx). Enter this number correctly as you will be
asked for it, together with the serial number of the workstation
if you call us for servicing purposes. Click Next.
7. Enter the software access code (4 sets of 5 characters). This
code is found on a label in the TitraMaster 85 CD-ROM box.
Click Next then OK.
Important
Keep carefully your serial number and access code in a safe
place. If you loose them, you will be not able to re-install the
software!
ocedurocedur
ocedur
ocedurocedur
ee
e
ee
8. Review your installation settings. Accept the installation
directory proposed by default clicking Next or change it
clicking the Change button.
9. Click the Next button. The setup program creates the
destination directory, transfers the files into the directory and
to the C:\Windows\System directory and creates an icon for
starting the TitraMaster 85 in the Start folder.
10. Click the OK button (information message about the
embedded software of the workstation).
11. Click the Finish button at the end of installation.
TitraMaster 85 will be installed in French if Windows is French
and in English in all other cases.
9
Important:
Make sure that you have downloaded the latest version of the
workstation (and ABU52 burette if relevant) embedded software.
Use FlashLoader Light to download this software into the
workstation.
Flashloader Light and the workstation embedded software are
available on your TitraMaster85 CD-ROM.
If you change your Windows operating system on your PC, you
must uninstall then reinstall TitraMaster 85.
Getting helpGetting help
Getting help
Getting helpGetting help
Click to gain access to the TitraMaster 85 on line help.
You can also press F1 or select the command ? > Contents in
the TitraMaster 85 window to display the contents menu of the
help file. From here, select the item of interest or search for a
certain topic.
10
StarStar
PC serial or USB port
Star
StarStar
Connecting workstationsConnecting workstations
Connecting workstations
Connecting workstationsConnecting workstations
Connect the PC/PRINTER socket on the workstation to a
9-pin male serial port COM1 on the PC using cable part no.
A95X501.
You can also connect the PC/PRINTER socket on the workstation
to an USB port on the PC using cable part no. A95X501 and an
USB to serial port converter.
If necessary, connect the printer to a parallel or USB port on the
PC. Connect the workstation to the mains using the line cord part
no. A95S001 (230 V) or A95S002 (115 V). Switch on the
workstation (O/I switch).
NB: You can connect up to 7 workstations to a PC serial or USB
port. The workstations are interconnected as follows:
ting upting up
ting up
ting upting up
PC serial or USB port
Important: RS232 cable length
must not exceed 20 m (length
from the PC to the last
workstation connected).
11
StarStar
ting TitraMaster 85 for the first timeting TitraMaster 85 for the first time
Star
ting TitraMaster 85 for the first time
StarStar
ting TitraMaster 85 for the first timeting TitraMaster 85 for the first time
1.Select Start > TitraMaster 85 and select Supervisor.
2. Type "default" (use
lower case letters).
3. Type "password"
(use lower case letters).
4. Click the Change
password button.
Type a new login
(6 characters min.).
Type a new password
(6 characters min.).
Re-enter this password
and click OK (*).
(*) Concerning passwords
In TitraMaster 85, any user, irrespective of his profile, must
change password every at least 90 days. Passwords cannot be
reused.
(**) Note to portable PC users only.
At first start, uncheck this option (no “✓“ must be displayed) then
select the File > Scan USB -> RS232 ports command from the
TitraMaster 85 main window in the menu bar. Then refresh the
workstation list.
5. If you have connected on switched
on your workstation, check that this
option is selected (**).
6. TitraMaster 85 scans the PC's serial and USB ports and
detects the workstations connected and on-line.
12
Loading...
+ 28 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.