Quikserv CHF-25 Installation Manual

DISCHARGE AIR FLOW
Drawing Name: Scale:
Rev.
Drawn By:
Quikserv Corp.
Date:
CHF-25 INSTALLATION
10/16/2014
BC
N/A
CHF-25 HEATED AIR CURTAIN INSTALLATION
Job Name:
Actual Dimension:
9-1/8" (W) X 23-1/4" (L) X 11-3/4" (H)
NOTE:THIS DRAWING EMBODIES A CONFIDENTIAL PROPRIETY DESIGN ORIGINATED AND OWNED BY QUIKSERV CORP., AND IS SUBMITTED UNDER A CONFIDENTIAL
RELATIONSHIP. ALL PATENT, MANUFACTURING, SALE RIGHTS REGARDING THE SAME ARE RESERVED EXCEPT TO THE EXTENT RIGHTS ARE EXPRESSLY GRANTED TO
OTHERS. THE RECIPIENT AGREES BY ACCEPTING THESE DRAWINGS NOT TO SUPPLY OR DISCLOSE ANY INFORMATION REGARDING THEM TO ANY UNAUTHORIZED PERSON.
17-1/4"
1) QUIKSERV'S AIR CURTAINS MUST BE INSTALLED LEVEL AND SQUARE TO WORK PROPERLY.
2) ANCHOR SCREWS TO BE SUPPLIED BY OTHERS.
7) PULL POWER SUPPLY INTO LEFT OR RIGHT SIDE OF JUNCTION BOX.
TYPICAL CHF-25 HEATED
AIR CURTAIN INSTALLATION
3) USE THE 2 ANCHOR KEY HOLES PROVIDE TO ANCHOR THE AIR CURTAIN TO THE WALL.
4) MAXIMUM HEIGHTS UP TO 4' ABOVE BOTTOM OF WINDOW.
5) ELECTRICAL SPECIFICATIONS- 208/230 VOLT 20 AMP CIRCUIT.
ETL APPROVED FOR INTERIOR USE.
(SEEFIG. 1)
6) REMOVE 2 SCREWS ON ELECTRICAL BOX COVER & REMOVE COVER. (LOCATED ON TOP OF AIR CURTAIN)
11) ANY OTHER TYPE OF ANCHORING OR WIRING TO BE APPROVED BY CERTIFIED ENGINEER.
10) NOTE : ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN, USING COPPER WIRING.
SEE WIRING DIAGRAM.
8) CONNECT 208/230 POWER SUPPLY TO WIRES LOCATED IN ELECTRICAL BOX.
9) CONNECT GROUND WIRE TO GROUND SCREW IN ELECTRICAL BOX.
Loading...