Drawing Name: Scale:
Rev.
Drawn By:
Quikserv Corp.
1-800-388-8307
www.quikserv.com
Date:
CHF-25 INSTALLATION
10/16/2014
BC
N/A
CHF-25 HEATED AIR CURTAIN INSTALLATION
Job Name:
Actual Dimension:
9-1/8" (W) X 23-1/4" (L) X 11-3/4" (H)
NOTE:THIS DRAWING EMBODIES A CONFIDENTIAL PROPRIETY DESIGN ORIGINATED AND OWNED BY QUIKSERV CORP., AND IS SUBMITTED UNDER A CONFIDENTIAL
RELATIONSHIP. ALL PATENT, MANUFACTURING, SALE RIGHTS REGARDING THE SAME ARE RESERVED EXCEPT TO THE EXTENT RIGHTS ARE EXPRESSLY GRANTED TO
OTHERS. THE RECIPIENT AGREES BY ACCEPTING THESE DRAWINGS NOT TO SUPPLY OR DISCLOSE ANY INFORMATION REGARDING THEM TO ANY UNAUTHORIZED PERSON.
17-1/4"
1) QUIKSERV'S AIR CURTAINS MUST BE INSTALLED
LEVEL AND SQUARE TO WORK PROPERLY.
2) ANCHOR SCREWS TO BE SUPPLIED BY OTHERS.
7) PULL POWER SUPPLY INTO LEFT OR RIGHT SIDE OF
JUNCTION BOX.
TYPICAL CHF-25 HEATED
AIR CURTAIN INSTALLATION
3) USE THE 2 ANCHOR KEY HOLES PROVIDE TO
ANCHOR THE AIR CURTAIN TO THE WALL.
4) MAXIMUM HEIGHTS UP TO 4' ABOVE BOTTOM
OF WINDOW.
5) ELECTRICAL SPECIFICATIONS- 208/230 VOLT 20 AMP
CIRCUIT.
ETL APPROVED FOR INTERIOR USE.
(SEEFIG. 1)
6) REMOVE 2 SCREWS ON ELECTRICAL BOX COVER &
REMOVE COVER. (LOCATED ON TOP OF AIR CURTAIN)
11) ANY OTHER TYPE OF ANCHORING OR WIRING
TO BE APPROVED BY CERTIFIED ENGINEER.
10) NOTE : ALL WIRING SHOULD BE DONE BY A
QUALIFIED ELECTRICIAN, USING COPPER WIRING.
SEE WIRING DIAGRAM.
8) CONNECT 208/230 POWER SUPPLY TO WIRES
LOCATED IN ELECTRICAL BOX.
9) CONNECT GROUND WIRE TO GROUND SCREW
IN ELECTRICAL BOX.