Service Manual
Electric BP-7252E Dual Opening Window
ELECTRIC BP-7252E
DUAL OPENING
Service Manual
BP-7252E DUAL OPENING
Contents
Operation and Maintenance Procedures 2
Trouble Shooting 3-6
Limit Switch Adjustment 7
Component Rack Removal 8
Parts Description 9
Window hardware Detail 10
PC Board Components 11
Wiring Diagrams 12-13
Warranty Service Policy 14
• 1-800-388-8307 • Fax (713) 849-5708 Quikserv Corp. quikserv.com
1

Se
Electric BP-7252E Dual Opening Window
ELECTRIC BP-7252E DUAL OPENING
Operaon and Maintenance Procedures
Remove access cover panel to service electrical and
mechanical components
Operation Procedures:
Unlock all locking mechanisms and ensure
that the doors are free of obstructions.
Turn the power Switch to the “on” position,
located on the upper left hand corner.
(Some windows the switch may be located
behind the access cover.)
General Maintenance:
Proper operation of the “Up-Eye” unit re-
quires the attendant to be directly in front
of and over all 3 photoelectric sensors
while serving. Proper operation of the
“Thru-Beam” unit requires the attendant to
stand between the Emitter and Receiver
eyes.
<Note> The photo-bar should be lined up
with the middle of the service opening.
General Cleaning Guidelines:
All weather-stripping should be checked
and cleaned weekly.
All glass, aluminum framing, stainless
steel, and plastic eye covers & lens should
be kept clean at all times. All cleaning flu-
ids and applicators should be nonabrasive.
Always disconnect the power supply before
servicing.
Slide rail system should be kept clean and
re-oiled with light weight oil every six (6)
months.
The eye-sets should be checked weekly to
make sure they are fully fastened to unit or
wall. They should also be cleaned of any
dirt or debris daily with non-abrasive cleaner.
Please refer to the trouble shooting section for
additional information on the window adjust-
ments or service procedures.
Contact us at (800) 388-8307 for assistance or
for information on the nearest service center in
your area.
2
• 1-800-388-8307 • Fax (713) 849-5708 Quikserv Corp. quikserv.com

Service Manual
Electric BP-7252E Dual Opening Window
ELECTRIC BP-7252E DUAL OPENING
TROUBLE SHOOTING REFERENCE
PAGE
Trouble Probable Cause Probable Soluon
1. No power to the unit Check the Circuit breaker
Window
Does
Not Operate
2. Power Switch is o or defecve Turn on switch or replace (Fig. 1-A)
3. Fuse in switch or pc board blown Check and Replace (Fig. 1-C or 6-B)
4. Component Rack not plugged in Check and plug in (Fig. 1-B)
5. Open limit switch defecve or discon-
nected
6. Defecve eye set Replace defecve part (Fig. 5-E or G)
7. Obstrucon in door movement Check locks, slide rail, and remove
Connue Page 4
3
Replace or reconnect (Fig. 1-Z & J)
obstrucons.
• 1-800-388-8307 • Fax (713) 849-5708 Quikserv Corp. quikserv.com

Service Manual
Electric BP-7252E Dual Opening Window
Trouble Shoong Electric BP-7252E Dual Opening
Trouble Probable Cause Probable Soluon
8. Defecve motor or capacitor Replace motor (Fig. 1-D & I)
Window
9. Thermal overload tripped in motor Replace or adjust limit switches (Fig. 2)
Does
Not Operate
10. Defecve PC Board Replace (Fig. 1-F)
11. Defecve slide rail Replace (Fig. 1-L)
12. Electric lock defecve or adjusted Adjust or replace (Fig. 1-N)
Trouble Probable Cause Probable Soluon
Doors stay in
the open
posion
1. Closed limit switch is defecve or dis-
connected
2. Eye assembly is unplugged or discon-
nected
3. Photo-eye is obstructed or misaligned Remove obstrucon (Fig. 5-E)
4. Faulty eye wire connecon Check all connecons-repair or replace
5. Defecve PC board Replace (Fig. 1-F)
6. Reverse gear in motor bad Replace (Fig. 1-D)
7. Door misaligned Adjust door (Fig. 1-M & G)
Replace or reconnect (Fig. 1-E )
Check connecon point (Fig. 5)
Trouble Probable Cause Probable Soluon
Motor runs
but the doors
does not
operate
1. Motor sha pulley or pulley block
loose
2. Broken drive belt Replace (Fig. 1-H)
3. Belt bracket loose or missing Tighten or replace (Fig. 1-G)
4. Bad motor Replace (Fig. 1-D)
4
Tighten or replace (Fig. 1-D or K)
• 1-800-388-8307 • Fax (713) 849-5708 Quikserv Corp. quikserv.com

Service Manual
Electric BP-7252E Dual Opening Window
Trouble Shoong Electric BP-7252E Dual Opening
Trouble Probable Cause Probable Soluon
Window will
run for short
period then
1. Thermal overload in the motor has
been tripped
Limit switch or switches may not be set
properly (Fig. 2) & (Fig. 1-E, Z & J)
stop
Trouble Probable Cause Probable Soluon
Doors are
dragging or
binding
1. Slide rail is dirty or defecve Clean and oil or replace if needed. (Fig.1-
L)
2. Loose door bracket Tighten screws and make sure inserts in
door are not loose. (Fig.1-M)
3. Doors misaligned Adjust door (Fig.1-M & G)
3. Drive Belt too ght Loosen Drive Belt. (Fig. 1-H)
• 1-800-388-8307 • Fax (713) 849-5708 Quikserv Corp. quikserv.com
5