For more detailed specifications, visit www.quadtech.com • For more information about special purchase, rent & lease options, call
1-800-253-1230 • Fax 1-978-461-4295 • Intl. 1-978-461-2100
5 Clock Tower Place, 210 East, Maynard, MA 01754
Product Specifications
PN030092/A1
Test Frequency: Range: 20Hz to 1MHz, Continuous
Resolution: 1Hz from 20Hz to 1KHz,
4 digits >1KHz
Accuracy: +/- (0.02% +0.02 Hz)
Measurement Speed: Speed Accuracy Setting
40 meas/sec Low, No Display
25 meas/sec Low
10 meas/sec Medium
1meas/sec High
Ranging: Automatic, Range Hold or user selectable
Trigger: Internal (automatic)
External (via RS-232,IEEE-488.2 or Handler
interfaces)
Manual
Source Impedance: 5Ω, 25Ω, 50Ω, 100Ω
AC Test Signal: Voltage: 20mV to 1.0V (open circuit) in 5 mV
steps
DC Test Signal: Voltage: 20mV to 1.0V (open circuit) in 5 mV
steps, 5 Ω source impedance
DC Bias Voltage: Internal: 0 to 2V in 1mV steps
Display: LCD Display with backlight
Pass/Fail and status indicators
Results Formats: Engineering or scientific format
%Deviation from nominal of primary parameter
Deviation from nominal of primary parameter
Pass/Fail
No Display Mode for maximum throughput
Sequencing:
Displays up to 6 sequential test results, primary
and/or secondary
Standard Interfaces: IEEE-488.2, RS-232, Handler
Measurement Delay: Programmable from 0 to 1000 ms in 1ms steps
Averaging: Programmable from 1 to 1000
Median Value: Averaged over last three measurements
Setup Storage: 30 Single Tests
10 Sequential (6 tests in each)
Other: Constant Voltage Mode (voltage leveling)
Cable Compensation (1M, 2M, no cable)
Open/Short Zeroing
Distortion Check
Calibration: Recommended interval 1 year
NIST traceable calibration
Built-in automatic calibration procedure
Usage & Cal Data: Displays last calibration date, standard values used
in calibration
Self Test: Verifies critical instrument operation at power-up or
when selected from menu
Test Terminals: Front panel, four terminal (BNC)
Optional Test Fixtures Available
Mechanical: Bench mount with tilt bail
Rack mount kit optional
Dimensions: (w x h x d):17 x 5.25 x 16in (432 x 133 x 406 mm)
Weight: 15lbs (8kg) net, 21lbs (9.9kg) shipping
Enviromental: Meets MIL-28800E, Type 3, Class 5, Style E & F
Operating: 0° to +50°C
Humidity: < 75% for 11° to 30°C operating
Storage: -40° to +71°C
Power: 100-240 VAC 50/60 Hz
100 W Max
1920 Precision LCR Meter
Parameter Measurement Range Basic Measurement Accuracy*
Low Medium High
Ls,Lp 0.001nH to 99.999H +/-0.5% +/-0.25% +/-0.1%
Cs,Cp .01pF to 9.9999F +/-0.5% +/-0.25% +/-0.1%
DF 0.00001 to 99.999 +/-0.005 +/-0.0025 +/-0.001
Q 0.00000 to 9999.9 +/-0.005 +/-0.0025 +/-0.001
Y,Gp,Bp 10 nS to 9999.9 S +/-0.5% +/-0.25% +/-0.1%
|Z|,Rs,Rp,Xs,ESR 0.00001 mΩ to 99.999MΩ +/-0.5% +/-0.25% +/-0.1%
Phase Angle -180.00 to +179.99 degrees +/-1.8° +/-0.9° +/-0.18°
DCR 0.1mΩ to 100KΩ +/-0.5% +/-0.25% +/-0.1%
DUT AC Voltage 20mV to 1.0V +/-(2% + 5mV)@1kHz
DUT AC Current 1µA to 150mA +/-(2% + 5µA)@1kHz
DUT DC Voltage 20mV to 1.0V +/-(2% + 5mV)
DUT DC Current 1µA to 150mA +/-(2% + 5µA)
*At optimum test signal levels, frequencies, DUT values and without calibration uncertainty.
Ordering Information
1920 Precision LCR Meter
Includes:
4200-0300 AC Power Cord
150566 Instruction Manual
Calibration Certificate
Traceable to NIST
Optional Accessories
1700-01 Axial/Radial Component
Test Fixture
1700-02 Axial/Radial Remote Test Fixture
1700-03 4 BNC Connectors to 2 Kelvin Clips Lead Set
1700-04 4 BNC Connectors to 4 Banana Plugs
1700-05 4 BNC Connectors to Chip Component Tweezers
2000-16 Rack Mount Flanges
7000-01 BNC to BNC Cable Set (1M)
7000-02 BNC to BNC Cable Set (2M)
7000-07 Low Voltage Chip Component Test Fixture