Q-Logic EVA ISCSI, 6000, 4400, 4100 User Manual

QuickSpecs
HP StorageWorks EVA iSCSI Connectivity Option
HP StorageWorks EVA iSCSI Connectivity Option
HP StorageWorks EVA iSCSI Connectivity OptionHP StorageWorks EVA iSCSI Connectivity Option

Overview

The HP StorageWorks EVA iSCSI Connectivity Option provides modular multi-protocol SAN designs with increased scalability, stability and ROI on storage infrastructure.
Over 70% of servers within a data center are not connected to Fibre Channel SANs for any of the following reasons:
Do not require FC Performance Cost of the Connectivity to SAN is too high Distances are too great
In the typical organization, each distributed server has its own directly attached storage and backup devices. Because these devices are isolated from other servers, excess capacity cannot be redeployed.
This EVA option extends the FC SAN investment with integrated multi-protocol support, allowing customers to incorporate iSCSI servers without requiring additional storage arrays or management costs. Fibre Channel SANs based on EVA technology are now able to leverage IP networks to create larger SAN sizes across longer distances. This enables increased consolidation. Instead of potentially underutilized, direct-attached, server-dedicated storage, a multi-protocol SAN provides access to storage that is allocated as and when it is needed.
The EVA iSCSI Connectivity Option enables organizations to integrate low-cost Ethernet-connected servers into an EVA by bridging the iSCSI protocol to the Fibre Channel protocol. This capability allows iSCSI servers to leverage shared SAN resources, improving asset utilization and enabling new applications. This integration greatly reduces the cost of connecting servers to centrally managed storage and helps provide a cost-effective solution to introduce utility computing into the enterprise.
An EVA with multi-protocol support also provides network storage at reduced infrastructure costs. Small and medium businesses now have a lower entry point to take advantage of SAN benefits. Large enterprises may also deploy multi-protocol SANs in departments and remote offices.
Key Benefits:
Delivering SAN like benefits over the Ethernet IP network, the HP StorageWorks EVA iSCSI Connectivity Option is an integrated hardware unit that enables access to block storage on a EVA FC SAN across an Ethernet network Provides customers a flexible and cost effective way to connect stranded servers to existing Fibre Channel storage increasing return on investment. DAS to SAN via IP Extend access to and the virtues of FC SANs across Ethernet networks including:
Consolidated storage Improved disk utilization Improved IT efficiency
DA - 12413 Worldwide — Version 10 — June 19, 2009
Page 1
QuickSpecs
HP StorageWorks EVA iSCSI Connectivity Option
HP StorageWorks EVA iSCSI Connectivity Option
HP StorageWorks EVA iSCSI Connectivity OptionHP StorageWorks EVA iSCSI Connectivity Option
Overview
Key Features
Key Features
Key FeaturesKey Features
Supports two Ethernet and two Fibre Channel ports Increase the flexibility of EVAs by adding integrated iSCSI support Delivers the benefits of SAN storage at a significant discount to FC SAN storage Concurrent FC and IP traffic is managed with high throughput enabling access 150 iSCSI servers and LUNS Integrated management with Command View EVA iSCSI ready for the following operating systems:
Apple Mac OS X (via iSCSI Initiator from ATTO Technology) HP OpenVMS Microsoft Windows Linux Red Hat Linux SUSE Sun Solaris
VMware Supports High Availability Multi-path Options for HP OpenVMS, Linux, Microsoft Windows, Sun Solaris, and VMware Fabric and Direct Attach support
DA - 12413 Worldwide — Version 10 — June 19, 2009
Page 2
QuickSpecs

Models

HP StorageWorks iSCSI
HP StorageWorks iSCSI
HP StorageWorks iSCSIHP StorageWorks iSCSI Connectivity Option
Connectivity Option
Connectivity OptionConnectivity Option (mpx100)
(mpx100)
(mpx100)(mpx100)
HP StorageWorks EVA
HP StorageWorks EVA
HP StorageWorks EVAHP StorageWorks EVA 4400 iSCSI Connectivity
4400 iSCSI Connectivity
4400 iSCSI Connectivity4400 iSCSI Connectivity Option (mpx100b)
Option (mpx100b)
Option (mpx100b)Option (mpx100b)
HP StorageWorks EVA iSCSI Connectivity Option
Order this part for all new installations for EVA4000/4100/4400/6000/6100/6400/8000/8100/8400, EVA3000/5000. Includes One unit, shelf, brackets, copper FC cables and documentation.
HP StorageWorks EVA iSCSI Connectivity Upgrade Option
Includes one unit to mount in existing shelf and documentation
For multi-path (dual unit high availability) order both part numbers. (The second hardware unit installs into the shelf that ships with AE324A.)
HP StorageWorks EVA 4400 iSCSI Connectivity Option Order this part for all new installations for EVA 4400 only. Includes one unit, shelf, brackets, copper FC cables and documentation. Supports 16 iSCSI initiators.
HP StorageWorks EVA 4400 iSCSI Connectivity Upgrade Option Includes one unit to mount in existing shelf and documentation. For use with EVA 4400 only.
HP StorageWorks EVA4400 iSCSI Connectivity 32 Initiator Upgrade License (LTU) For use with EVA 4400 only.
HP StorageWorks EVA iSCSI Connectivity Option
HP StorageWorks EVA iSCSI Connectivity Option
HP StorageWorks EVA iSCSI Connectivity OptionHP StorageWorks EVA iSCSI Connectivity Option
AE324A
AE325A
AJ713A
AJ714A
T5471A
DA - 12413 Worldwide — Version 10 — June 19, 2009
Page 3
QuickSpecs

Product Highlights

Configuration Support
Configuration Support
Configuration SupportConfiguration Support
Manageability
Manageability
ManageabilityManageability
Scalability
Scalability
ScalabilityScalability
Software Components, Standard
Software Components, Standard
Software Components, StandardSoftware Components, Standard
Command View
Command View
Command ViewCommand View
The iSCSI Connectivity Option is fully compatible with the HP B-Series, C-Series, and M-Series of FC switches. For complete interoperability information please check:
http://www.hp.com/go/SANdesign http://www.hp.com/go/SANdesignguide
Two hardware units may be implemented for high availability and redundant data paths.
Command View EVA mpx Manager
Initial support: Refer to the guidelines described in the HP StorageWorks SAN Design Reference Guide available at:
HP StorageWorks Command View EVA provides the capability to manage the EVA and is installed on an existing Storage Management Appliance, a management server or a NAS server. This powerful tool provides an easy mechanism to manage EVA storage systems in a SAN configuration. Command View EVA is purchased separately from XCS media kit.
http://www.hp.com/go/SANdesignguide
HP StorageWorks EVA iSCSI Connectivity Option
HP StorageWorks EVA iSCSI Connectivity Option
HP StorageWorks EVA iSCSI Connectivity OptionHP StorageWorks EVA iSCSI Connectivity Option
DA - 12413 Worldwide — Version 10 — June 19, 2009
Page 4
QuickSpecs
HP StorageWorks EVA iSCSI Connectivity Option
HP StorageWorks EVA iSCSI Connectivity Option
HP StorageWorks EVA iSCSI Connectivity OptionHP StorageWorks EVA iSCSI Connectivity Option

Service and Support, HP Care Pack and Warranty Information

Warranty
Warranty
WarrantyWarranty
HP Service & Warranty
HP Service & Warranty
HP Service & WarrantyHP Service & Warranty Support
Support
SupportSupport
(1-1-1) Hardware Warranty - One-year on-site warranty, 8x5, next business day response, installation not included.
NOTE:
NOTE:
The hardware warranty covers firmware and embedded non-saleable software.
NOTE:NOTE:
HP Service & Warranty Support Additional Warranty protection and/or HP Installation packages can be purchased.
NOTE:
NOTE:
NOTE: NOTE: provides a one-year, hardware limited warranty, fully supported by a worldwide network of resellers and service providers.
In addition, available service offerings include a full range of HP Care Pack packaged hardware and software services:
For more information on warranty and support options, please visit our Web site at:
http://www.hp.com/hps/tech/storage/supp/
Certain restrictions and exclusions apply. Consult the Customer Support Center for details. HP
Installation Extended coverage hours and enhanced response times System management and performance services
.
Software Product Services
Software Product Services
Software Product ServicesSoftware Product Services
Hardware Product
Hardware Product
Hardware ProductHardware Product Services
Services
ServicesServices
HP Care Pack Services
HP Care Pack Services
HP Care Pack ServicesHP Care Pack Services Warranty Upgrade
Warranty Upgrade
Warranty UpgradeWarranty Upgrade Options
Options
OptionsOptions
Stand-alone telephone support Rights to a new license Media and documentation updates
Installation services On-site Maintenance (includes warranty support) Response time upgrades during the warranty period Post-warranty coverage
Service offerings include a full range of Customer HP Care Pack services for both hardware and software services:
Response - Upgrade on-site response from next business day to same day 4-hours Coverage - Extend hours of coverage from 5 days x 9 hours to 7 days x 24 hours
Duration - Select duration of coverage for a period of 1, 3, or 5 years Additional Warranty protection and/or HP Installation packages can be purchased.
NOTE:
NOTE:
Certain restrictions and exclusions apply. Consult the HP Customer Support Center for details.
NOTE:NOTE:
DA - 12413 Worldwide — Version 10 — June 19, 2009
Page 5
QuickSpecs
HP StorageWorks EVA iSCSI Connectivity Option
HP StorageWorks EVA iSCSI Connectivity Option
HP StorageWorks EVA iSCSI Connectivity OptionHP StorageWorks EVA iSCSI Connectivity Option
Service and Support, HP Care Pack and Warranty Information
HP Care Pack Information
HP Care Pack Information
HP Care Pack InformationHP Care Pack Information
Additional Services
Additional Services
Additional ServicesAdditional Services
HP Care Pack is defined as an upgrade to the product warranty attribute, available for a specific duration and hours of coverage.
HP Care Pack is not available for less than the product's warranty duration. HP Care Pack is available for sale anytime during the warranty period for most products, but the
commencement date will be the same as the Warranty Start Date (delivery date to end user customer). Proof of purchase may be required.
HP Care Pack services are prepaid. For additional HP Care Pack (hardware & software) information, as well as orderable part numbers,
please refer to the URL:
http://h18005.www1.hp.com/services/carepaq/index.html
Implementation service, SAN Architecture service. For more information on service options, please visit our Web site at:
http://www.hp.com/go/san
.
DA - 12413 Worldwide — Version 10 — June 19, 2009
Page 6
QuickSpecs

Configuration Information

Step 1 - Base Configuration and Power Pack
Step 1 - Base Configuration and Power Pack
Step 1 - Base Configuration and Power PackStep 1 - Base Configuration and Power Pack
Select one: Model
Model
ModelModel StorageWorks EVA iSCSI
Connectivity Option (mpx100)
StorageWorks EVA iSCSI Connectivity Upgrade (mpx100)
StorageWorks EVA 4400 iSCSI Connectivity Option (mpx100b)
StorageWorks EVA 4400 iSCSI Connectivity Upgrade (mpx100b)
StorageWorks EVA 4400 iSCSI Connectivity Option 32 Initiator Upgrade LTU (for mpx100b only)
Model Description
Model Description
Model DescriptionModel Description Includes 1 unit, shelf, brackets, 2 copper FC cables (for direct connect to EVA) and
documentation
NOTE:
NOTE:
Fabric iSCSI-Fibre Channel attachment mode requires optical transceivers and
NOTE:NOTE: cables listed below.
Includes 1 unit to mount in existing shelf and documentation
NOTE:
NOTE:
For multi-path (dual unit) support order both part numbers.
NOTE:NOTE: NOTE:
NOTE:
For a highly redundant direct connect environment, recommend customer
NOTE:NOTE: purchase 2 additional FC copper cables listed below (see the HP StorageWorks EVA iSCSI connectivity user guide).
Includes 1 unit, shelf, brackets, copper FC cables (for direct connect to EVA) and documentation. For use with EVA 4400 only.
NOTE:
NOTE:
NOTE: NOTE: cables listed below.
Includes 1 unit to mount in existing shelf and documentation. For use with EVA 4400 only.
NOTE:
NOTE:
NOTE:NOTE: NOTE:
NOTE:
NOTE:NOTE: purchase 2 additional FC copper cables listed below (see the HP StorageWorks EVA iSCSI connectivity user guide).
Includes 1 license upgrade to enable connectivity for an additional 32 iSCSI initiators. If a second license is installed, it provides an upgrade to the maximum supported number of iSCSI initiators. Refer to the guidelines described in the EVA iSCSI Connectivity User Guide available on the Storage Networking product page and the HP StorageWorks SAN Design Reference Guide available at:
http://www.hp.com/go/sandesignguide
Fabric iSCSI-Fibre Channel attachment mode requires optical transceivers and
For multi-path (dual unit) support order both part numbers. For a highly redundant direct connect environment, recommend customer
HP StorageWorks EVA iSCSI Connectivity Option
HP StorageWorks EVA iSCSI Connectivity Option
HP StorageWorks EVA iSCSI Connectivity OptionHP StorageWorks EVA iSCSI Connectivity Option
Part Number
Part Number
Part NumberPart Number
AE324A
AE325A
AJ713A
AJ714A
T5471A
.
Step 2 - Additional Options
Step 2 - Additional Options
Step 2 - Additional OptionsStep 2 - Additional Options
Optical Transceivers
Optical Transceivers
Optical TransceiversOptical Transceivers EVA Loopback Connector
Short Wave - 300m The loopback connector is used when an EVA host port is not cabled to a switch,
mpx100/100b (for iSCSI direct connect), or HBA (for FC direct connect).
NOTE:
NOTE:
All EVA host ports must be filled with either a cable or loopback connector.
NOTE:NOTE:
DA - 12413 Worldwide — Version 10 — June 19, 2009
A7446B
AJ706A
Page 7
QuickSpecs
Configuration Information
2 Gb optical cables
2 Gb optical cables
2 Gb optical cables2 Gb optical cables (Required for Fabric attach)
FC Copper cables
FC Copper cables
FC Copper cablesFC Copper cables (Recommended for a highly redundant direct connect environment (see the HP StorageWorks EVA iSCSI connectivity user guide)
LC-LC for between two 2 Gb devices
LC-LC for between two 2 Gb devices
LC-LC for between two 2 Gb devicesLC-LC for between two 2 Gb devices 2 m LC-LC Multi-Mode Fibre Channel Cable 5 m LC-LC Multi-Mode Fibre Channel Cable 15 m LC-LC Multi-Mode Fibre Channel Cable 30 m LC-LC Multi-Mode Fibre Channel Cable 50 m LC-LC Multi-Mode Fibre Channel Cable LC-SC for between a 1 Gb and a 2 Gb device
LC-SC for between a 1 Gb and a 2 Gb device
LC-SC for between a 1 Gb and a 2 Gb deviceLC-SC for between a 1 Gb and a 2 Gb device 2 m LC-SC Multi-Mode Fibre Channel Cable 5 m LC-SC Multi-Mode Fibre Channel Cable 15 m LC-SC Multi-Mode Fibre Channel Cable 30 m LC-SC Multi-Mode Fibre Channel Cable 50 m LC-SC Multi-Mode Fibre Channel Cable 2m Copper FC Cable
HP StorageWorks EVA iSCSI Connectivity Option
HP StorageWorks EVA iSCSI Connectivity Option
HP StorageWorks EVA iSCSI Connectivity OptionHP StorageWorks EVA iSCSI Connectivity Option
221692-B21 221692-B22 221692-B23 221692-B26 221692-B27
221691-B21 221691-B22 221691-B23 221691-B26 221691-B27 324394-B21
DA - 12413 Worldwide — Version 10 — June 19, 2009
Page 8
QuickSpecs

Technical Specifications

HP StorageWorks EVA iSCSI Connectivity Option
HP StorageWorks EVA iSCSI Connectivity Option
HP StorageWorks EVA iSCSI Connectivity OptionHP StorageWorks EVA iSCSI Connectivity Option
Arrays supported
Array Connectivity Mode
Maximum Number of EVA iSCSI Connectivity Options
Maximum Number of EVA storage systems per mpx
Management Software Support
OS Support
Host Platform Support Cluster Support Fibre Channel Interface FC Transceiver FC Connectivity
Mode IP Interface
iSCSI Initiator Support
iSCSI Network Card Support
TCP/IP Offload Engine Support (TOE)
IP Security
EVA 4000, 4100, 4400, 6000, 6100, 6400, 8000, 8100, 8400 EVA 3000, 5000
EVA 4x00, 6x00, 8x00 EVA 3000 and 5000 2 EVA iSCSI Connectivity Options supported per EVA
1 EVA per mpx100 or mpx100b
Configure FC LUNs and iSCSI initiators through EVA Command View v9.1, v9.0, v8.1, v8.0.2, v8.0.1, v8.0, v7.0, v6.02
Apple Mac OS X (via iSCSI Initiator from ATTO Technology) HP OpenVMS (EVA iSCSI Connectivity Option (mpx100) only) Microsoft Windows Linux Red Hat Linux SUSE Sun Solaris VMware For operating system version support, see the HP StorageWorks SAN Design Reference Guide available at:
Any server running supported OS None Dual Port, 2Gb 4Gb SFP, supported @ 2Gb speed Fabric attach Direct connect Dual port, 1GbE (IPv6, IPv4)
Microsoft iSCSI Initiator (32-bit and 64-bit versions) Linux iSCSI Initiator (32-bit and 64 it versions) ATTO Macintosh iSCSI Initiator HP OpenVMS iSCSI Initiator Sun Solaris iSCSI Initiator VMware iSCSI Initiator Product supporting EVA 4400 is limited to 16 initiators with base unit. License upgrades are available in two steps, a 32 initiator license, followed by an unlimited license up to the HP supported maximum.
Any HP 1GbE NIC Apple, Sun supported 1GbE NICs NIC Teaming is supported for extra redundancy
NOTE:
NOTE:
NOTE: NOTE:
HP NC510x, NC3xx TOE supported Alacritech TOE Card supported Qlogic QLA4052c, 4062c iSCSI HBA
NOTE:
NOTE:
NOTE: NOTE:
Standard 10/100 NIC cards are not supported
Support is operating system dependent
http://www.hp.com/go/sandesignguide
Direct connect and fabric attach Fabric attach
.
Optical connected as an N-Port connected as an NL-Port
iSCSI Boot
CHAP User name and password authentication. Password encryption of saved configuration file
Linux, Windows, VMware
DA - 12413 Worldwide — Version 10 — June 19, 2009
Page 9
QuickSpecs
Technical Specifications
HP StorageWorks EVA iSCSI Connectivity Option
HP StorageWorks EVA iSCSI Connectivity Option
HP StorageWorks EVA iSCSI Connectivity OptionHP StorageWorks EVA iSCSI Connectivity Option
Installation
Installation
InstallationInstallation Environmental
Environmental
EnvironmentalEnvironmental Specifications
Specifications
SpecificationsSpecifications
Multi-Path support
Max. Pending Commands Host Interface Distance Host Platform Support Performance
Maximum Host Connection Design Limits for iSCSI
User installable, but recommended field service install Optional side-by-side 1U rack mount kit
Non-cable-side to cable-side airflow; power from cable-side; 1U, 19-in. EIA rack-compliant Cooling: Two fans with back-to-front airflow
Environment
Environment
EnvironmentEnvironment Temperature
Temperature
TemperatureTemperature
Humidity
Humidity
HumidityHumidity Altitude
Altitude
AltitudeAltitude Shock
Shock
ShockShock
Vibration
Vibration
VibrationVibration
Power AC input Nominal
Power AC input Nominal
Power AC input NominalPower AC input Nominal Frequency Range
Frequency Range
Frequency RangeFrequency Range Nominal Frequency
Nominal Frequency
Nominal FrequencyNominal Frequency Range
Range
RangeRange Power Dissipation
Power Dissipation
Power DissipationPower Dissipation
1
Environmental specification for operating condition should be satisfied before the iSCSI Connectivity Option subsystem is powered on. Maximum temperature of 40°C should be strictly satisfied at air inlet portion.
2
Non-operating condition includes both packing and unpacking conditions unless otherwise specified.
3
No condensation in and around the iSCSI Connectivity Option should be observed under any conditions.
4
The above specifications of vibration are applied to all three axes. On shipping/storage condition, the product should be packed with factory packing.
*
3
4
HP OpenVMS Windows Linux Sun VMware Default value of 64. Uses standard TCP/IP connection, RJ45 connector GbE Copper, CAT-5e or CAT-6, twisted pair Any 32-bit or 64-bit servers running the supported OS half duplex full duplex Architectural Limits
256 connections per iSCSI port mpx100b is limited to 16 iSCSI initiator ports in base unit. License upgrades are available in two steps, a 32 initiator license followed by an unlimited license up to the HP supported maximum.2 FC target ports, with maximum initiators
* Please see the product user guide available on the Storage Networking product page and the SAN Design Guide for latest tested and supported configurations located at:
Operating
Operating
OperatingOperating
5° to 40° C
(41° to 104° F)
5 to 90%, non-condensing 5 to 93%, non-condensing
3 km
IEC 68-2, 4g, 11ms, 20 repetitions
IEC 68-2, 5-500Hz, random, 0.21G
rms, 10 minutes
Power AC input Nominal: 0.5A@100-125 VAC 0.25A@200-240 VAC
http://www.hp.com/go/sandesignguide
Condition
Condition
ConditionCondition
1
50 Hz to 60 Hz
48W maximum (optics included)
Native Microsoft MPIO Device Mapper MPxIO Native software MPxIO
>30,000 > 200 MB / Sec > 360 MB / Sec
Non Operation
Non Operation
Non OperationNon Operation
-25°C to 70° C
(-40° to 158° F)
15 km
IEC 68-3, 30g, 292 ips, 3 repetitions,
3 axis
IEC 68-2, 5-500Hz, random, 2.09G
rms, 10 minutes
47 to 63 Hz
.
2
DA - 12413 Worldwide — Version 10 — June 19, 2009
Page 10
QuickSpecs
HP StorageWorks EVA iSCSI Connectivity Option
HP StorageWorks EVA iSCSI Connectivity Option
HP StorageWorks EVA iSCSI Connectivity OptionHP StorageWorks EVA iSCSI Connectivity Option
Technical Specifications
Physical Size
Physical Size
Physical SizePhysical Size
© Copyright 2009 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
Height Width Depth Weight
1U (1.7 in/4.32 cm)
8.5 in (21.59 cm) 12 in (30.48 cm) 10 lb (4.54 kg)
DA - 12413 Worldwide — Version 10 — June 19, 2009
Page 11