Quick Start Guide Fibre Channel Host Bus Adapter
BR-815, BR-825
Information furnished in this manual is believed to be accurate and reliable. However, QLogic Corporation assumes no
responsibility for its use, nor for any infringements of patents or other rights of third parties which may result from its
use. QLogic Corporation reserves the right to change product specifications at any time without notice. Applications
described in this document for any of these products are for illustrative purposes only. QLogic Corporation makes no
representation nor warranty that such applications are suitable for the specified use without further testing or
modification. QLogic Corporation assumes no responsibility for any errors that may appear in this document.
Document Revision History
Revision A, April 30, 2014
Revision B, October 6, 2014
ChangesSections Affected
Changed model designations to QLogic BR.“Welcome” on page iii
Revised note to tell users to use only QLogic-sup-
ported SFPs in these adapters.
For the Linux SLES OS, replaced “QASI” with
“ASI.”
“Welcome” on page iii
“Software Installation on Windows, Linux, and
Solaris Systems” on page 6
iiBR0054507-00 B
Page 3
Welcome
NOTE
Thank you for purchasing a QLogic BR-800 Series Fibre Channel Host Bus
Adapter. These adapters provide reliable, high-performance host connectivity for
mission-critical Storage Area Network (SAN) environments. Available models are
listed in the following table.
QLogic BR-800 Series Fibre Channel Host Bus Adapters allow a host system to
connect to a Fibre Channel SAN in a switched-fabric or point-to-point topology.
The combined high performance and proven reliability of a single-ASIC design
makes these HBAs ideal for connecting hosts to SAN fabrics based on Brocade
Fabric OS
®
(FOS) or Brocade M-Enterprise OS (M-EOS).
Install only QLogic-supported SFPs in these adapters.
Related Materials
The following documents are available on the QLogic Web Site:
Customers should contact their authorized maintenance provider for technical
support of their QLogic products. QLogic-direct customers may contact QLogic
Technical Support; others will be redirected to their authorized maintenance
provider. Visit the QLogic support Web site listed in Contact Information for the
latest firmware and software updates.
For details about available service plans, or for information about renewing and
extending your service, visit the Service Program Web page at
QLogic Global Training maintains a Web site at www.qlogictraining.com offering
online and instructor-led training for all QLogic products. In addition, sales and
technical professionals may obtain Associate and Specialist-level certifications to
qualify for additional benefits from QLogic.
Contact Information
QLogic Technical Support for products under warranty is available during local
standard working hours, excluding QLogic Observed Holidays. For customers
with extended service, consult your plan for available hours. For Support phone
numbers, see the Contact Support link at support.qlogic.com.
Support Headquarters
QLogic Web Site
Technical Support Web Site
Technical Support E-mail
Technical Training E-mail
Knowledge Database
The QLogic knowledge database is an extensive collection of QLogic product
information that you can search for specific solutions. QLogic is constantly adding
to the collection of information in the database to provide answers to your most
urgent questions. Access the database from the QLogic Support Center:
http://support.qlogic.com.
QLogic Corporation
4601 Dean Lakes Blvd.
Shakopee, MN 55379 USA
Installing a QLogic BR-800 Series Fibre Channel Host Bus Adapter consists of the
following tasks:
“Verifying Installation Requirements” on page 1
“Verifying Items for Installation” on page 1
“Preparing the Host System” on page 2
“ESD Precautions” on page 2
“Installing Hardware” on page 3
“Installing Software” on page 5
Verifying Installation Requirements
Before you begin, make sure that your server (host) system meets hardware and
software compatibility requirements outlined in the BR-Series Adapters Installation Guide and the system is fully operational.
Verifying Items for Installation
Have the following items on hand for installation:
Multimode optical cable with LC duplex connectors to connect the
the
with appropriate mounting bracket attached
The adapter ships with two different bracket sizes. If the bracket that
you require is not already attached to the adapter, instructions are
included in this guide to attach it.
fabric.
HBA to
1BR0054507-00 B
Page 8
BR-815, BR-825 Fibre Channel Host Bus Adapter Quick Start Guide
NOTE
Preparing the Host System
Preparing the Host System
1.Make a backup of the system data.
2.Power down the host system. Unplug all power cords and network cables.
3.Remove all covers necessary to access the PCIe
install the adapter. Refer to your system documentation to locate PCIe slots
and cover removal procedures.
4.
Remove the blank bracket panel that covers the PCIe slot in which you want
to install the adapter. If the panel is sec
and save it for securing the adapter bracket panel into the slot.
Install adapters in PCI-Express slots that use an x8 lane transfer
interface or greater for best performance. You cannot install adapters
into PCI™ or PCI-X™ slots.
ured with a screw, remove the screw
®
slot in which you want to
ESD Precautions
When handling the adapter , use correct electro static d ischarge (ESD) procedures:
Wear a wrist grounding strap connected to chassis ground (if host is plugged
in) or a bench ground.
Store the adapter in anti-static packaging.
2BR0054507-00 B
Page 9
BR-815, BR-825 Fibre Channel Host Bus Adapter Quick Start Guide
PORT
01
Installing Hardware
Installing Hardware
To Install the adapter hardware into your host system:
1.If fiber optic SFP transceivers are installed in
the adapter, remove them if clearances
inside your system case prohibit installation
with them installed.
a.Pull out the protective rubber plug from
the SFP connector.
b.Using your thumb and forefinger,
unlatch the bail from the side of the
fiber optic cable connector and pull the
SFP straight out of the receiver . Arrows
stamped on the bail mark the location
where you unlatch it.
2.The adapter ships with one bracket installed
and another size bracket in the shipping container. If the installed bracket
works as is, go on to Step 3.
If your system chassis requires a different bracket (low-profile or standard)
to secure the adapter in the slot, perform the following steps to replace the
bracket. Note that you must remove SFPs first to remove this bracket (refer
to Step 1).
a.Remove the two screws attaching the
bracket to the adapter, and pull off the
bracket.
b.Carefully guide the new mounting
bracket onto the adapter, making sure
the bracket mounting tabs align with the
holes in the adapter.
c.Replace and tighten the two screws.
d.Store the mounting bracket that you
removed for future use.
The illustration shows the standard bracket.
3BR0054507-00 B
Page 10
BR-815, BR-825 Fibre Channel Host Bus Adapter Quick Start Guide
Edge of
Host Board
Press Here
Screw
Press Here
PCI Express
X8 Slot
SFP Receivers
Installing Hardware
3.Insert the adapter into the desired empty PCIe bus slot. Press firmly until the
adapter is seated.
4.Secure the adapter’s mounting bracket to the case using the method
required for your case. In some systems, the bracket may be secured to the
case with a screw.
5.Replace the system’s case or covers and tighten all screws.
4BR0054507-00 B
Page 11
BR-815, BR-825 Fibre Channel Host Bus Adapter Quick Start Guide
NOTE
Installing Software
6.Install all SFPs if not already installed.
Use the correct cable with LC connectors to connect the adapter to the
switch.
Orient the SFP in front of its slot on the HBA s
a.
HBA receiver slot. The SFP can be oriented only one way into the slot.
b.Using the bail as a handle, slide the SFP into the HBA receiver until it
is seated, and then latch the bail.
7.Replace the system’s case or covers and tighten all screws.
8.Connect the adapter to the switch.
For fiber optic SFPs:
a.Pull out the protective rubber inserts from the fiber optic SFP
connectors, if installed in the switch or adapter.
b.Connect the cable to the adapter and to the appropriate LC connector
on the switch.
For copper cable SFPs, connect the cable to the adapter and to the
appropriate LC connector on the switch.
9.Turn on host power and observe LED operation. Refer to the “LED
operation” section for your adapter in the “Specifications” chapter of the
BR-Series Adapters Installation Guide for details on LED operation.
o that it can slide into the
Installing Software
Use the Adapter Software Installer (ASI) to install the Host Connectivity Manager
(HCM), all driver packages, and utilities based on your host o perating system. The
following procedures assume that the host’s operating system has been installed
and is functioning normally.
“Software Installation on Windows, Linux, and Solaris Systems” on page 6
“Software Installation on VMware Systems” on page 10
ASI can install HCM either on the local host or any remote system. An HCM
desktop shortcut is available after installing HCM on Windows
®
Solaris
in a host system.
systems. Only one driver installation is required for all adapters installed
Software installation could take much longer than normal with a large number of
adapters installed or where a large number of LUNs are e xposed through dif ferent
paths to the multipath sof tware. For more det ails and options on inst alling adapter
software, such as using ASI or native installation system commands, refer to the
“Software Installation” chapter in the BR-Series Adapters Installation Guide.
Software Inst allation on Windows, Linux, and Solaris Systems
Before installing software on a Windows, Linux, or Solaris system, consider the
exceptions in the following table:
OSException
Windows When installing driver packages on Windows 2008 and later systems,
open TCP/IP port 34568 to allow HCM Agent communication with the
HCM. (Necessary because of firewall issues.) Following is an example
for opening port 34568:
Use Windows Firewall and Advanced Service (WFAS) to open port
34568.
Before installing drivers on Windows 2008 systems, install hot fixes
KB968675 and KB2490742 from the Microsof t
Site, and then reboot the system. For more information on these hot
fixes, refer to “Installation Notes” in the BR-Series Adapters Installation Guide.
For Windows systems only, installing management utilities creates a
BCU shortcut on your system desktop. Use this shortcut to launch the
BCU> command prompt and enter BCU commands.
Linux SLES When installing the source-based (noarch) driver packages
(brocade_driver_linux_<version>.tar.gz) or when using the ASI and the
kernel has been upgraded to a version without pre-compiled binaries,
perform the following tasks to make sure the drivers load. After wards, be
sure to reboot the system.
For Linux SLES
unsupported_modules_automatically variable is set to yes in
/etc/sysconfig/hardware/config.
For Linux SLES 11 systems, make sure the
allow_unsupported_modules variable is set to 1 in
/etc/modprobe.d/unsupported-modules.
Run the mkinitrd command to load automatically during system boot.
By default, the initrd file will be backed up automatically during Linux
installations. During installation, a dialog box shows the location of the
file. If a file exists, a dialog box allows you to overwrite the file, not
overwrite the file, or quit.
®
10 systems, make sure the load_
SolarisAfter installing drivers on Solaris system, you must reboot the system to
enable the drivers.
To install adapter software on Windows, Linux, and Solaris systems:
1.Download the Adapter Installer Software for your adapter:
a.Go to the QLogic Web Site at http://driverdownloads.qlogic.com
and
select the Adapters tab and the by Model radio button.
b.In the table, select Fibre Channel Adapters in the first column,
BR-815 or BR-825 in the second column, the operating system in the
third column, and then click Go.
c.In the Software Inst a llers t able, locat e the installer package, click on it,
and then follow the directions.
2.Execute the appropriate Adapter Software Installer (refer to Step 1). When
all files are extracted, an Adapter Software title window appears.
3.When the Adapter Software Installer Introduction window appears, read the
recommendations and instructions, and then click Next.
4.When the License Agreement appears, select I accept the terms of theLicense Agreement, and then click Next to continue.
5.If a backup directory exists for previously installed software, a FoundBacked up data message prompts you to restore old configurations.
Select either to restore or not to restore and continue installation. If this
message does not appear, go on to Step 6.
6.If a message window lists existing software components already installed on
your system, select one of the following options, and then click Continue,
and then skip to Step 10. If this message does not appear, go on to Step 7.
Install with existing configuration. The installer compares each
configured property and keeps the original value if different from the
default value.
Install with default configuration. The installer upgrades the
software and loads with default configurations.
7.If a message prompts you to close HCM, close the application if it is running,
and then click OK on the message box.
8.When the Choose Install Set window appears, select the software you want
to install, and then select Next.
If you are installing the management utilities and mes
sages warn that HCM
agent requires storage and network driver installation or does not match
current driver installation, and then click OK, and then select the
Management Utilities and Storage and Network Drivers options to install.
If a message warns that the installed boot image is not compatible with the
driver installation, perform one of the following steps:
Select Yes to update the image and continue installation.
Select No to not update the image and continue installation.
9.If the Choose Install Folder window prompts you to choose a destination
folder for the software, select one of the following options. If this window
does not appear, go on to Step 10.
Enter a location for installing the software.
Select Choose to browse to a location on your file system.
Select Restore DefaultFolder to enter the default installation folder.
10.When the Package Location Information window lists the installed software
components and their location on your system, select Next to continue.
8BR0054507-00 B
Page 15
BR-815, BR-825 Fibre Channel Host Bus Adapter Quick Start Guide
NOTE
Installing Software
11.Review information on the Pre-Installation Summary window and select
Install to begin installation.
A progress bar shows the installation progress.
For Windows systems, a Force Driver Installation message
box appears if a better driver is already installed for the adapter. If the
message appears, select OK to overwrite the existing driver or Cancel
to quit installation.
12.When the Install Complete window lists installed components, confirm that
all components are installed and select Done. If a message instructs you to
restart or reboot the system, select any options that apply.
13.Verify driver inst allation through tools available on your host system. Refer to
the “Confirming Driver Package Installation” section in the “Software
Installation” chapter of the BR-Series Adapters Installation Guide for details.
14.To make sure that the drivers and adapter boot code are synchronized, be
sure to update your adapter using the latest boot image:
a.Go to the QLogic Web Site at http://driverdownloads.qlogic.com
and
select Adapters, by Model.
b.In the table, select Fibre Channel Adapters in first column, BR-815 or
BR-825 in the second column, the operating system in the third
column, and then click Go.
c.Click the Boot Code link at the top of the page to direct you to the boot
code packages.
d.Locate the boot code package for your adapter in the table, click on it,
and then follow the directions.
For instructions on installing the boot image, refer to the “Boot Code”
chapter in the BR-Series Adapters Installation Guide.
15.When the driver is installed and the host system is connected to the switch
(refer to step 8 on page 5) observe adapter LED operation. Verify proper
LED operation by referring to “LED operation” in the “Specifications” chapter
of the BR-Series Adapters Installation Guide.
9BR0054507-00 B
Page 16
BR-815, BR-825 Fibre Channel Host Bus Adapter Quick Start Guide
NOTE
Installing Software
Software Installation on VMware Systems
The ASI is not supported on the VMware “console” operating system for installing
drivers, HCM, and utilities. However, you can use an applicable software installer
from the list under “Software Installation on Windows, Linux, and Solaris Systems”
on page 6 to install HCM on a “guest” system.
When installing driver packages on VMware systems, open TCP/IP port
34568 to allow HCM Agent communication with the HCM. (Necessary
because of firewall issues.) On VMware systems open port 5989 to allow
communication for CIM Provider.
1.Download the appropriate package using the following steps:
a.Go to the QLogic Web Site at http://driverdownloads.qlogic.com
and
select the Adapters tab, the by Model radio button, and then click Go.
b.In the table, select Fibre Channel Adapters in the first column,
BR-815 or BR-825 in the second column, VMware ESX/ESXi in the
third column, and then click Go.
c.Locate the driver package in the table of drivers for your version of
®
VMware ESX
/ESXi, click on it, and then follow the directions.
2.Copy the file to your system’s /tmp directory.
3.Follow instructions for ESX or ESXi installation under “Driver installation and
removal on VMware systems” in the Software Installation chapter of the
BR-Series Adapters Installation Guide.
Because some versions of ESX and ESXi do not enforce maintenance mode
during driver installation, it is recommended to put the host in maintenance mode,
as a reboot is required after installation.
10BR0054507-00 B
Page 17
Corporate Headquarters QLogic Corporation 26650 Aliso Viejo Parkway Aliso Viejo, CA 92656 949.389.6000 www.qlogic.com