QLogic BR-1860 User Manual

QLogic BR-1860
Fabric Adapter
Data Sheet
• Provides a class of adapters that meets all Fibre Channel and Ethernet connectivity needs in cloud-enabled data centers
• Supports Gen 5 Fibre Channel and 10GbE DCB connectivity for TCP/IP, iSCSI, and FCoE with QLogic AnyIO® technology
• Consolidates I/O devices and optimizes QoS with QLogic vFLink technology
OVERVIEW
To keep pace with dynamic and growing business demands, many organizations are transitioning their data centers to private cloud architectures to leverage the many benets of virtualization. This approach enables them to consolidate, scale, simplify, and automate their IT resources to increase business agility while reducing capital and operational expenditures. The QLogic BR-1860, designed for today’s data centers, simplies the journey to the private cloud.
Server virtualization continues to be a key technology for enabling private cloud architectures. Organizations worldwide are taking virtualization to the next level, increasing virtual machine (VM) densities and virtualizing mission-critical workloads. This trend is increasing demand for shared storage and atter, more scalable networks—as well as higher bandwidth and I/O capacity for client/server and storage networks.
• Enhanced virtualization support, including Windows Server® 2012 Virtual Fibre Channel and network QoS (bandwidth management) functionality
• Centralized management through single pane-of-glass by integration with Brocade® Network Advisor
A SINGLE ADAPTER FOR ALL CONNECTIVITY NEEDS
Available in single-port and dual-port models, the BR-1860 features QLogic AnyIO technology, making it the industry’s rst multiprotocol server connectivity product designed for highly virtualized, cloud-enabled data centers. The BR-1860 is a new class of adapters that combines a Gen 5 Fibre Channel Host Bus Adapter with a 10-gigabit Ethernet (GbE) Converged Network Adapter and a NIC to support native Fibre Channel, TCP/IP, data center bridging (DCB) Ethernet, Fibre Channel over Ethernet (FCoE), and iSCSI running simultaneously in a single product.
To help address that demand, the BR-1860 Fabric Adapter meets all the connectivity needs of cloud-enabled data centers while providing unmatched performance, application-aware services, unied management, and reduced cost and complexity. It is the simplest, most exible, and most powerful server connectivity adapter designed to extend fabric services to VMs and applications in highly demanding virtualized environments (Figure 1).
BR0058006-00 Rev. A 03/14 1
Gen 5 Fibre Channel is the purpose-built, data center-proven network infrastructure for storage, delivering unmatched reliability, simplicity, and 16Gbps performance. The BR-1860 Fabric Adapter with Gen5 Fibre Channel unleashes the full potential of high-density server virtualization, cloud architectures, and next-generation storage.
QLogic BR-1860
QLogic BR-1860 Fabric Adapters
Ethernet Fibre Channel
Data Sheet
I/O Virtualization (IOV) and Virtual Switching
The BR-1860 supports QLogic virtual Fabric Link (vFLink) technology, which partitions a single adapter into as many as eight virtual adapters called vNICs. This is done in hardware by using multiple physical functions (PFs) at the PCIe® bus level, appearing as separate physical devices at the OS level. These virtual links can be assigned minimum and/or maximum bandwidth levels allocated in 100Mbps increments, with a maximum of 10Gbps for Ethernet. This helps organizations overcome the proliferation of adapters in virtual environments while maintaining management isolation and quality of service (QoS) for different types of networks, including production, backup, management, or live migration (Figure 2).
Brocade Network Advisor
Orchestration
Figure 1. BR-1860 Fabric Adapter technology extends Fibre Channel and Ethernet fabric
services to the VMs and applications
Organizations have the exibility to choose, on a port-by-port basis, the adapter type and connectivity protocol that are most appropriate for their applications and their business requirements. This unmatched exibility allows organizations to standardize on a single adapter for all of their connectivity needs. IT departments can realize capital and operational savings by consolidating multiple lower-speed Fibre Channel Host Bus Adapters and 1GbE NICs into a single adapter, acquiring space-efcient 1U rack-mount servers, connecting to existing Fibre Channel and Ethernet networks without requiring additional switch ports, and future-proong their data centers for a seamless transition to multiprotocol networks.
Delivering full-duplex, line-rate 16Gbps Fibre Channel and 10GbE speeds, and over one million IOPS per dual-port adapter for storage applications— including Fibre Channel, FCoE, and iSCSI—the QLogic BR-1860 is the ideal platform to support the most demanding mission-critical workloads in the largest data centers. The BR-1860 supports full FCoE protocol ofoad as well as stateless networking ofoads for 10GbE, including TCP checksum and segmentation ofoads for improved performance and more efcient CPU utilization.
DESIGNED FOR THE PRIVATE CLOUD
Virtualization is transforming the data center, essentially moving the access layer of the network into the server. In addition to virtualizing I/O devices to allow them to be shared by the VMs, hypervisors have become, by necessity, software-based Ethernet switches that provide networking services for VMs—using CPU cycles and hindering virtualization scalability and performance. Even with the most powerful processors, at 16Gbps Fibre Channel and 10GbE speeds, hypervisors simply cannot keep up with I/O, and line-rate performance becomes impossible to achieve.
Figure 2. QLogic vFLink I/O virtualization technology enables I/O consolidation
To further improve performance in virtual environments, VMs can bypass the hypervisor and access I/O devices directly, leveraging server chipset technologies such as Intel® virtualization technology for directed I/O (VT-d) or AMD® I/O virtualization (AMD-Vi).
The BR-1860 will help organizations overcome this limitation through its ability to support the PCI-SIG® single root input/output virtualization (SR-IOV) specication1, which extends QLogic vFLink technology to support up to 255 virtual fabric links. SR-IOV utilizes PCIe virtual functions (VFs), which are lightweight PCI functions that are assigned to the VMs while the hypervisor retains control of the underlying PF. SR-IOV enables an efcient sharing of I/O devices for VMs as well as direct I/O for increased performance (Figure 3).
By implementing virtual machine optimized ports (VMOPs), the BR-1860 leverages hypervisor multiqueue technologies such as VMware® NetQueue and Microsoft® VMQ to ofoad the incoming network packet classication and sorting tasks from the hypervisor onto the adapter, freeing the CPU and enabling line-rate performance.
BR0058006-00 Rev. A 03/14 2
1 SR-IOV is hardware capable.
QLogic BR-1860
VM1
VF
DriverVFDriverVFDriver
VF1 VF2
Figure 3. SR-IOV enables efcient sharing of I/O resources with direct I/O for enhanced
VM2 VM3
.....
PF
Hypervisor
VF3 VFn
Physical Function
QLogic BR-1860 Fabric Adapter
performance
Driver
.....
VMn
VF
Driver
Data Sheet
Integration into Brocade's Brocade Network Advisor (BNA):
Provides customizable health and performance dashboard views to pinpoint problems faster, simplify SAN conguration and management, and reduce operational costs.
Critical diagnostic and monitoring capabilities: Helps ensure early
problem detection and recovery.
Forward error correction (FEC): Enables recovery from bit errors in
ISLs, enhancing transmission reliability and performance.
Credit loss recovery: Helps overcome performance degradation and
congestion due to buffer credit loss.
Diagnostic ports (D_Ports) are a port type that enables administrators to quickly identify and isolate optics and cable problems, reducing fabric deployment and diagnostic times. Organizations can also use Brocade's ClearLink diagnostics to run a variety of tests through QLogic Host Connectivity Manager (HCM), QLogic BCU CLI, or Brocade's BNA to test ports, SFPs, and cables for faults, latency, and distance.
The BR-1860 also incorporates a built-in virtual Layer 2 Ethernet switch, or virtual Ethernet bridge (VEB), to ofoad the hypervisor from all of the inter­VM trafc switching tasks, delivering better network performance for VMs while freeing the CPU for additional application processing.
Extend Fabric Services to the Server and Applications
The BR-1860 supports Brocade's Server Application Optimization (SAO) technology to extend the intelligence and fabric services of industry­leading Brocade Fibre Channel fabrics into servers. N_Port trunking extends the ISL trunking capability from the Brocade switches into the server, combining two 16Gbps links in a dual-port adapter into a single logical 32Gbps connection with frame-level load balancing for unmatched levels of performance and fault tolerance.
Brocade SAO also extends QoS from the fabric to the VM and application level, enabling organizations to virtualize mission-critical applications and scale virtualization environments with condence. Leveraging virtual channel technology in the Brocade switch and QLogic adapter ASICs, QoS ensures that mission-critical workloads will not be impacted by congestion or misbehaving devices, helping organizations more efciently meet application service level agreements (SLAs).
Unprecedented Visibility and Insight Across the Storage Network with Advanced Monitoring and Diagnostics
Offering innovative diagnostic, monitoring, and management capabilities, the BR-1860 helps administrators avoid problems, maximize application performance, and reduce operational costs with the following technologies:
Diagnostic port (D_Port) support: Ensures optical and signal integrity
for Gen 5 Fibre Channel optics and cables, simplifying deployment and support of high-performance fabrics. It leverages the ClearLink diagnostic port (D_Port) capabilities of Brocade's Gen 5 Fibre Channel switch platforms.
D_Port enabled diagnostic ports can be congured either explicitly by the user in static mode or forced by the switch port in dynamic mode. Dynamic mode automatically congures D_Ports on the adapter from the switch, streamlining deployment and reducing operational overhead. To take advantage of Brocade's ClearLink diagnostics functionality, the BR-1860 needs to be in Host Bus Adapter mode and requires 16Gbps optics.
In addition, the BR-1860 extends credit recovery and FEC from the SAN fabric to the server level. Extending these fabric services to the server improves link resiliency and enhances overall application performance and availability.
The BR-1860 is hardware-capable to support the upcoming virtual Ethernet port aggregator (VEPA) standard as dened by the IEEE
Edge Virtual Bridging (EVB)
switched by the access layer switch in the network. Combined with QLogic vFLink technology, VEPA logically extends the physical Ethernet switch all the way to the VMs. This allows networking policies to be dened with VM granularity and enables the delivery of VM-aware services and VM-level trafc monitoring.
Optimal Support for Windows Server 2012 and 2012 R2
By supporting Windows Server® 2012, the BR-1860 enhances its ability to support Windows-based virtual workloads and provides network administrators with policy-based tools to manage trafc on the virtual and physical networks. Furthermore, its support of the Hyper-V® virtual Fibre Channel feature enables direct connectivity to Fibre Channel SANs from within a Hyper-V VM, allowing Fibre Channel SANs to seamlessly support Windows-based virtualized workloads. Support for Fibre Channel in Hyper-V guests also includes support for many high-availability features, such as virtual SANs, clustered VMs, live migration, and multipath I/O (MPIO).
specication. VEPA allows inter-VM trafc to be
802.1Qbg
BR0058006-00 Rev. A 03/14 3
QLogic BR-1860
Through its support of Windows Server 2012 policy-based QoS, the BR-1860 enables administrators to specify network bandwidth controls based on application type, users, and servers for the physical network. In addition, support of Hyper-V QoS enables cloud hosting providers and enterprises to deliver predictable network performance for multiple types of trafc for VMs using BR-1860 adapters running in DCB mode.
SIMPLIFYING SERVER DEPLOYMENT WITH DYNAMIC FABRIC PROVISIONING
Dynamic fabric provisioning (DFP) allows organizations to eliminate fabric reconguration when adding or replacing servers through the virtualization of host world wide names (WWNs). It combines Brocade switch and QLogic adapter technology to reduce or eliminate the need to modify zoning or LUN masking. In addition, DFP enables pre-provisioning of virtual WWNs, helping organizations eliminate time-consuming steps when deploying new equipment or moving devices within a switch.
CENTRALIZED ADAPTER MANAGEMENT
QLogic’s Host Connectivity Manager (HCM) is an easy-to-use adapter management tool for conguring, monitoring, and troubleshooting the QLogic BR-series adapters. HCM enables server administers to quickly congure BR-series adapters locally or remotely.
Data Sheet
HCM scans the SAN environment to discover visible storage resources and display target LUNs. A simple to use graphical tree view provides fast access to the managed Host Bus Adapters, Converged Network Adapters, ports, and target storage resources. HCM also provides notications of various conditions and problems through a user-dened event lter.
In addition to providing a graphical interface, QLogic also provides a powerful command line interface, BCU CLI, for scripting and task automation.
For holistic data center-wide management, QLogic HCM is tightly integrated with Brocade Network Advisor (BNA) to provide end-to­end conguration and management of the entire SAN infrastructure. Administrators can launch QLogic HCM from within BNA to provide single­pane-of-glass management of QLogic BR-series adapters and Brocade switches.
QLogic also provides open APIs and standards-based interfaces for integration with popular third-party applications.
MAXIMIZING INVESTMENTS
To help optimize technology investments, QLogic and its partners offer complete solutions that include professional services, technical support, and education. For more information, contact a QLogic sales partner or visit www.qlogic.com.
BR0058006-00 Rev. A 03/14 4
QLogic BR-1860
Data Sheet
Fibre Channel Specications
Data Rate
14.025Gbps (1600MBps); 8.5Gbps
(800MBps); 4.25Gbps (400MBps); 2.125Gbps (200MBps) auto-sensing (perport); full duplex
Performance
• Over 500,000 IOPS per port
(1,000,000 IOPS per dual-port adapter)
Topology
• Point-to-point (N_Port), switched fabric (N_Port),
FC-AL, FC-AL2
Key Features
• Dynamic fabric provisioning (DFP). Fibre Channel
fabric assigned worldwide name (FA-PWWN)
• D_Port. Port type enabling rapid isolation of optics or
cable problems
• Credit recovery. Buffer credit loss detection and
automatic recovery at 16GFC
• Forward error correction (FEC): error recovery
mechanism when operating at 16Gbps link speed
• N_Port trunking. Aggregation of 2×16Gbps links
into a single logical 32Gbps link
Distance Support
• 15m at 16Gbps on 62.5/125μm (OM1) multimode
ber (MMF)
• 35m at 16Gbps on 50/125μm OM2 MMF
• 100m at 16Gbps on 50/125μm OM3 MMF
• 125m at 16Gbps on 50/125μm OM4 MMF
• 10km at 16Gbps on 9/125μm single-mode ber
(SMF)
Ethernet Specications
Data Rate
10.3125Gbps
Boot Options
• Pre-boot execution environment (PXE and gPXE), BIOS, UEFI
FCoE Specications
Performance
• Over 500,000 IOPS per port (1,000,000 IOPS per dual-port adapter)
Host Specications
Server Platform
• Intel (IA32, IEM64T), AMD (x86, 64), and Sun® (x86, SPARC®)
Bus Interface
• PCI Express Gen 2.0 compatible (x8), with MSI-X and INTx
Software
Management
• QLogic Host Connectivity Manager (HCM)
• QLogic BCU CLI
Operating Systems
• For the latest applicable operating system information, see http://driverdownloads.qlogic.com.
Physical Specications
Form Factor
• PCI Express low-prole form factor;
16.77cm×6.89cm (6.60in.×2.71in.)
Operating Humidity
5% to 93% (relative, non-condensing)
Non-Operating Humidity
5% to 95% (relative, non-condensing)
Operating Voltage
12V
Agency Approvals
United States
• Bi-Nat UL/CSA 60950-1 2nd Ed; ANSI C63.4; cCSAus; FCC Class B
Canada
• Bi-Nat UL/CSA 60950-1 2nd Ed; ICES-003 ClassB; cCSAus
Japan
CISPR22 Class B and JEIDA (Harmonics); VCCI-B
European Union
• EN60950-1; EN55022 Class B and EN55024; TÜV Bauart, CE Mark
Australia, New Zealand
• EN55022 and CISPR22 Class B or AS/NZS CISPR22; C-Tick
Russia
IEC60950-1; 51318.22-99 and .24-99; GOST Mark
Korea
KN22 and KN24; KC Mark Class B
Taiwan
CNS 13438(95) Class A; BSMI Mark
Ordering Information
Distance Support
• 33m at 10Gbps on 62.5/125μm OM1 MMF
• 82m at 10Gbps on 50/125μm OM2 MMF
• 300m at 10Gbps on 50/125μm OM3 MMF
• 10km at 10Gbps on 9/125μm SMF
Frame Sizes
• All standard Ethernet frame sizes supported, including 9,600 byte jumbo frames and mini-jumbo frames
BR0058006-00 Rev. A 03/14 5
Environmental and Power Requirements
Airow
45 linear feet per minute (LFM)
Operating Temperature
0ºC to 55ºC /32ºF to 131ºF (dry bulb)
Non-Operating Temperature
−43ºC to 73ºC/−40ºF to 163ºF (dry bulb)
BR-1860-1
Ships in a single pack with low-prole and standard
BR-1860-2
• Ships in a single pack with low-prole and standard
brackets
brackets
xxx
(single port)
xxx
(dual port)
QLogic BR-1860
Data Sheet
NOTICES
Brocade Network Advisor (BNA) is a management solution from Brocade that enables unied management across SAN and IP networks. Brocade Server Application Optimization (SAO) is an optional feature available on Brocade switches. SAO works with QLogic BR series adapters to enhance application performance and VM scalability. Licenses for Brocade's BNA and SAO products can be purchased separately through Brocade Corporation.
DISCLAIMER
Reasonable efforts have been made to ensure the validity and accuracy of these performance tests. QLogic Corporation is not liable for any error in this published white paper or the results thereof. Variation in results may be a result of change in conguration or in the environment. QLogic specically disclaims any warranty, expressed or implied, relating to the test results and their accuracy, analysis, completeness or quality.
Follow us:
Corporate Headquarters QLogic Corporation 26650 Aliso Viejo Parkway Aliso Viejo, CA 92656 949-389-6000
International Offices UK | Ireland | Germany | France | India | Japan | China | Hong Kong | Singapore | Taiwan
www.qlogic.com
© 2013, 2014 QLogic Corporation. Specications are subject to change without notice. All rights reserved worldwide. QLogic, the QLogic logo, and AnyIO are registered trademarks of QLogic Corporation. AMD is a registered trademark of Advanced Micro Devices, Inc. Brocade and VCS are registered trademarks of Brocade Communications Systems, Inc. EMC is a registered trademark of EMC Corporation. IBM, FICON, and Tivoli are registered trademarks of International Business Machines Corporation. HP is a registered trademark of Hewlett-Packard Development Company, L.P. Intel is a registered trademark of Intel Corporation. Microsoft, Windows Server, and Hyper-V are registered trademarks of Microsoft Corporation. PCI-SIG and PCIe are registered trademarks of PCI-SIG Corporation. Sun is a registered trademark of Oracle Corporation. SPARC is a reg­istered trademark of SPARC International, Inc. in the USA and other countries. VMware, ESX, and vCenter are trademarks or registered trademarks of VMware Inc. in the United States and other countries. All other brand and product names are trademarks or registered trademarks of their respective owners. Information supplied by QLogic Corporation is believed to be accurate and reliable. QLogic Corporation assumes no responsibility for any errors in this brochure. QLogic Corporation reserves the right, without notice, to make changes in product design or specications.
Share:
BR0058006-00 Rev. A 03/14 6
Loading...