KEYLESS ENTRY ALARM UPGRADE MODULE
INSTALLATION INSTRUCTIONS
PRE - INSTALLATION NOTES :
This system provides an output that should be used to drive the siren, but can be programmed to pulse the vehicle's horn. When utilizing the horn, an additional relay is required. Caution: on many vehicles the factory horn is not designed
for continuoususe,anditisrecommended that the siren is used for thesevehicles.Checktoseeif the horn in the vehicle is the same part that is used in a vehicle with the factory installed security system.
STAND ALONE PASSIVE ALARM
When installing the APS-30 as a stand alone passive alarm system, the dip switches must be set as follows;
Dip Switch#1=ON Dip Switch#2=ON Dip Switch#3=OFF Dip Switch#4=OFF Dip Switch#5=OFF Dip Switch#6=OFF
DIP SWITCH SETTINGS
ON OFF
1 2 3 4 5 6
PASSIVE / ACTIVE ARMING SELECTION : DIP SWITCH # 1
As a passive arming system, the alarm will automatically arm 30 seconds after the ignition key is turned off, one door is opened, then all doors are closed. Additionally, if a door has been left opened, or if one of the trigger zones is defective, the system will always arm 10 minutes after the ignition key has been turned off, and ignore the defective trigger zone.
As an active arming system, the alarm will arm only when the vehicle’s doors have been locked using the existing OEM Keyless Entry Transmitter.
The system is shipped from the factory in the active arming mode, and to select the passive arming mode, move dip switch#1tothe" ON " position.
1 OR 2 WIRE DISARM INPUT SELECTION : DIP SWITCH # 2
This alarm can be programmed for either 1 wire or 2 wire disarm operation.
Many OEMkeylessentrysystems use on - board doorunlockrelays,which usually results in the abilitytodisarmtheaftermarket security upgrademodulebyunlocking the doors usingthedoorpanel unlock switch. Wiringthesystem for 2 wiredisarmwilleliminate this problem.
The system is shipped from the factory in the 2 wire disarm mode, and to select the 1 wire disarm mode, move dip switch#2tothe" ON " position.
HORN OR SIREN OUTPUT SELECTION : DIP SWITCH # 3
PASSIVE ARMING
1 WIRE DISARM
HORN MODE
INSTANT TRIGGER
- ARM INPUT
VOLTAGE SENSE
ACTIVE ARMING
2 WIRE DISARM
SIREN MODE
ENTRY DELAY
+ ARM INPUT
HARDWIRE
This alarm can be programmed to drive an electronic siren, or pulse the vehicle's horn.
Inthesirenmode, the audible outputwilldelivera switched + 12VDCoutput when the systemistriggered.This allows for directconnection to an optional electronic siren.
In thehornmode,the audible output ( WHITE w/ BLACKtracerwire) will deliver a pulsed + 12 voltoutputwhen the system is triggered. This allows for connection to the vehicle’s horn, using an external relay, which will beep the horn when the alarm is triggered.
The system is shipped from the factory in the siren mode, and to select the horn mode, move dip switch#3tothe"ON"position.
INSTANT OR DELAYED DOOR TRIGGER SELECTION : DIP SWITCH # 4
This alarm can be programmed for either instant trigger on the door zone, or for an entry delay on the door zone. The primary use of the entry delay would be when the APS-30 is installed as a stand alone passive alarm system, and is not being used with an existing Remote Keyless Entry system.
In the instant mode, opening any door will trigger the alarm immediately.
In the entry delay mode, opening any door will provide a 15 second delay before the alarm is triggered. This provides ample time to put the key into the ignition, and switch it to the " ON " position, which will disarm the system when wired as a stand alone alarm.
IMPORTANT : In the entry delay mode, when the alarm is armed actively, the doors will trigger the alarm instantly. The entry
IMPORTANT : THE ENTRY DELAY WILL NOT OPERATE WHEN THE VOLTAGE SENSING CIRCUIT IS ACTIVE
This alarm can be programmed to accept either a positive or negative arm input signal. This allows for proper installation into vehicles using 3 wire ground, 3 wire + 12 volt, and 5 wire alternating door locking systems.
In the negative mode, the system will operate with keyless entry systems providing a ground output to the power door lock circuit.
In the positive mode, the system will operate with keyless entry systems providinga+12volt output to the power door lock circuit. The positive mode should also be used in vehicles whose Keyless Entry system uses on - board relays that switch a high current + 12 volts directly to the door lock motor legs.
The system is shipped from the factory in the + 12 volt input mode, and to select the ground input mode, move dip switch#5tothe" ON " position.
This alarm can be programmed to operate as either a voltage sensing or hardwire system.
In the voltage sensing mode, any entry point that turns a light on will trigger the alarm.
In the hardwire mode, any entry point that is wired to the system will trigger the alarm.
The system is shipped from the factory in the hardwire mode, and to select the voltage sensing mode, move dip switch#6tothe " ON " position.
This system provides a positive trunk release input, which allows the activation of the remote trunk release from the OEM transmitter without triggering the alarm, even when it is armed.
delay will only take place when the alarm is allowed to arm passively!
(DIP SWITCH # 6 ON).
POSITIVE OR NEGATIVE ARM INPUT SELECTION : DIP SWITCH # 5
VOLTAGE SENSE OR HARDWIRE SELECTION : DIP SWITCH # 6
TRUNK TRIGGER BY - PASS INPUT
INSTALLATION OF MAJOR COMPONENTS :
ALARM CONTROL MODULE
Select a mounting location inside the passenger compartment ( up behind the dash ), and secure using screws, or the control module can be secured in place using cable ties.
Do not mount the control module in the engine compartment, as it is not waterproof.