IMPORTANT INFORMATION
CONDARI PTY LTD makes over 120 different models of QASAIR and CONDOR Rangehoods plus many specials designed by architects and interior designers.
It is important to follow the installation instructions for each model.
The following is general advice for the installation of CONDOR Rangehoods.
Gas regulations require different heights for different brands of hoods. CONDOR hoods can be tted between
1200 mm to 1400 mm above the barbecue. This is due to the fact they do not have plastic motors.
1. The installation of CONDOR Rangehoods must comply with the information in this booklet. CONDOR
Rangehoods are designed and made to work efciently over all domestic barbecues available on the
Australian market.
2. Every CONDOR Rangehood must be ducted to the outside atmosphere by the use of zinc-alume duct or
non-porous and non-ammable materials. We do not recommend the use of any type of exible ducting or plastic PVC piping (barbecue heat output will affect exible ducting and cause it to desintegrate).
Rangehoods must not be vented into a wall cavity or a ceiling space. This prevents a build up of grease,
which can be a re risk. Ensure the external outlet vent does not restrict the airow in any way, as this may
result in reduced performance.
3. CONDOR Rangehoods must be ducted in duct work equivalent to the outlet of the rangehood ie: The cross sectional area of the rangehood outlet and the duct work must be equal. Do not reduce the duct size or have sharp bends. Enlarge the duct size if the duct is to run 6 metres or longer. Advice from
CONDOR is available to ensure optimum performance. Always use nonammable materials to minimise the risk of re in the duct at a later date.
4. Ensure all ducting pieces are correctly tted and sealed with either duct tape or silicone to ensure that fumes do not escape into the ceiling space and seep into living areas through vents or light ttings. The installation and tting of the rangehood should be done in such a way that will allow the unit to be removed if service is
required. Additional costs incurred in the removal of wall tiles, damage to walls or bench tops are not covered by warranty.
5. Always adequately ventilate the room when the rangehood is in use at the same time as appliances burning gas or other fuels.
6. WARNING: Incorrect venting will result in additional noise and a reduction in efciency. Exhaust air must not
be discharged into any chimney or ue, which may carry combustible products from other sources. a) Do not discharge the air-ow from the rangehood into a ue used for exhausting fumes
from burning gas or fuel; b) A reduction in ducting size will result in the motors eventually failing and will need replacement. c) For cleaning purposes please refer to page 27 of installation instructions for stainless steel; d) If cleaning is not carried out in accordance with the instructions as listed on page 27, you may have an increased risk of re; e) Accessible parts of the rangehood may become hot when used with cooking appliances; f) This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
4
Condor Rangehood Installation Instructions
7. If the supply cord is damaged, an authorised service centre or licensed electrician must replace it.
8. NOTE: CONDARI recommend minimum air movement of 2000 cubic metres per hour and recommend up
to 2700 cubic metres per hour over a barbecue, depending on the length of the duct run. Barbecues should be positioned under the centre of the hood where the fans are mounted and not near the outer edges where leakage may occur. Please also note barbecue lid position, as if it does not open to a 90 degree angle the smoke and by-products can be diverted forward and away from the rangehood catchment area.
9. The lights in the rangehoods are LED.
10. To reduce the risk of xing screws coming in contact with live parts, do not drill or screw into the rangehood.
Live wires are encapsulated where possible to prevent user contact. If necessary drill from the inside out and only through single sheet material.
11. CONDARI can manufacture rangehoods to be used over commercial cookers in domestic applications.
NOTE: Installation must comply with local State & Council regulations.
Condor Rangehood Installation Instructions
5
INSTALLATION INSTRUCTIONS CONDOR RANGE
To suit wall mounted models:
Boston
Baltimore
Eyre
1. The installer will ensure that this installation will comply with the relevant local and state regulations.
2. Determine hood position on wall 1200mm to 1400mm above the cooking surface.
3. Mark centre line on wall.
4. Mark base line on wall.
5. Mark the outlet hole in the ceiling or wall for the outlet and cut out, removing any obstructions.
6. Remove the rear sound absorbing panels in hood by removing the lower screws for each panel. slide panel upwards, pull lower part of sound absorbing panel to clear lower bracket then slide downwards. For the Eyre model similar sound absorbing panels can be removed from top to access area above the inner fanbox if
extra xing are required above the inner fanbox.
7. Locate and drill mounting holes in wall as high and wide as possible to avoid Rangehood sagging from wall.
Drill xing holes in rear of hood to suit mounting holes on wall.
8. For the Eyre & Nullarbor extra support is required in the top via the All-thread holes as detailed on Technical
Specication Sheets pg 13 & 14 respectively
9. Remove protective lm from wall mounting bracket and x to wall at base height of hood making sure this is level and exactly central.
10. Locate position and cut hole for power cable. Consult your electrician for his preferred location.
11. If tting optional Condor ue (CFL-XXX refer pg.12) to suit Baltimore & Boston models, t the ue to top of Rangehood and secure by bending the 4 tabs over from inside the Rangehood.
12. Remove fans if needed and lift hood up onto wall mounting bracket carefully locating outlet through hole in ceiling/wall and bringing power cable into hood during this process. Take care when lifting ranghood into position and ensure you have enough people to lift safely.
13. Using appropriate xing method to safely support Rangehood, secure Rangehood to wall making sure
6
Condor Rangehood Installation Instructions
Rangehood is level and sitting properly on the wall mounting bracket. If required, for the Eyre / Nullarbor
model t 8mm all thread (threaded rod) through holes in top of Rangehood and secure to roof structure,
secure Rangehood with washers and nuts. Level Rangehood by tensioning the 8mm nuts, do not over tighten. It is advisable to use props or portable stands when attaching the Rangehood to the wall or ceiling.
14. Ret sound absorbing panels in the rear/top of the Rangehood and ret fans if they have been removed.
15. Electrical connection can now be made by a licensed electrician to the junction box inside bottom right side of Rangehood.
16. Extend ducting through to exterior and t roof cowl or wall vent. Making sure to seal roof/wall penetration with
preferred ashing material, consult your plumber for the best product to suit.
DUCT DIRECTION CHANGE INSTRUCTIONS
The following applies to the Boston, Baltimore and Nullabor models only as the outlet on the Eyre is not changeable. Before installing your Rangehood check whether the Duct Outlet is orientated for back or top ducting. For top ducting, the unit will have the air outlet at the top, and for back ducting, the unit will have the air outlet at the back. To change from top to back or back to top, proceed as follows:
INSTRUCTIONS TO CHANGE THE ORIENTATION OF THE RANGEHOOD OUTLET PLATE (Applies to Boston and Baltimore models)
1. Locate and remove 6x M4 Phillips head screws as shown below.
2. Once all screws are removed, push rangehood outlet plate from the inside of the rangehood outwards. Do
not push the fans as they are xed.
3. Reorient rangehood outlet plate from top to back ducted or vice versa, relocate back into range hood and replace 6x Phillips head screws removed previously.
Condor Rangehood Installation Instructions
7
Motor Box / Flue Width
Condari Pty Ltd. Page 1 of 2
Version: E 24/10/2018F
Body Width
Model
Motor Qty
Light Centres
Light Qty
Nightlight
LED Light
Filter Qty
Model
Filter Size
Conversion Top/Back Back/Top
Electrical Connection
Minimum Height (H =) Maximum Height (H =)
PowderKote
Available All-thread Fixing Centres
Corner Type
BCM 1000L-3 BCM 1500L-3BCM 1200L-3BCM 1000L-3BCM 1500L-3BCM 1200L-3
1000mm
580mm
6
800mm
3
Cool or Warm
NO
2
290mm x 290mm
YES
Junction Box
N/A
N/A
N/A
N/A
Round
1200mm
1000mm
3
Cool or Warm
NO
2
545mm
8
1500mm
1300mm
3
Cool or Warm
NO
3
459mm
6
272mm x 290mm
YES
Junction Box
N/A
N/A
N/A
N/A
Round
459mm x 290mm
YES
Junction Box
N/A
N/A
N/A
N/A
Round
Boston
Technical Specification Sheet
BCM
Wall Mounted
Power entry location
is the same for all
BCM models.
800
125
450
600
15mm Radius
Top Ducted
shown with flue
Back Ducted
shown with flue
Boston comes top ducted and can be converted to back ducted on site by the installer.
Flue options detailed on page 12
8
See page 7
Condor Rangehood Installation Instructions