Protherm 100 e User Instructions

1
Protherm 100 e
Users’ Instructions
Introduction........................................................................................................................... 2
Controls and lighting ............................................................................................................. 2
Draining and filling ................................................................................................................ 3
Heating safety valve ............................................................................................................. 3
Servicing/maintenance ......................................................................................................... 3
Cleaning ............................................................................................................................... 3
Boiler casing ......................................................................................................................... 3
Installation Instructions
Introduction........................................................................................................................... 4
Technical data ...................................................................................................................... 5
Dimensions........................................................................................................................... 6
Pump capacity ...................................................................................................................... 6
Boiler schematic ................................................................................................................... 7
Installation section ................................................................................................................ 8
Heating and hot water system design ................................................................................... 9
Boiler installation ................................................................................................................ 10
Horizontal flue installation ................................................................................................... 12
Vertical flue installation ....................................................................................................... 13
Flue configurations .............................................................................................................14
Electrical connection ...........................................................................................................15
Commissioning ...................................................................................................................16
Servicing Instructions
Routine cleaning and inspection ......................................................................................... 18
Replacement of parts ......................................................................................................... 19
Schematic wiring diagram................................................................................................... 22
Fault finding ........................................................................................................................ 23
Conversion to LPG ............................................................................................................. 24
Mandatory warning for CE countries
WARNING, these appliances were designed, approved and inspected to meet the requirements of the English
market. The identification plate located on the inside of the appliance certifies the origin where the product was
manufactured and the country for which it is intended.
If you see any exception to this rule, please contact your nearest stockist.
Thank you in advance for your assistance.
Note: The boiler serial number is marked on the data label attached to the fascia behind
the front panel. Refer to the ‘Introduction’ section for a description of the basic functions
of the boiler. The ‘User’ section describes how to safely operate the boiler.
2
USERS INSTRUCTIONS
The Protherm 100 e is a wall mounted combination boiler providing central heating and instantaneous domestic hot water.
These instructions should be carefully followed for the safe and economical use of your boiler.
Gas leak or fault
If a gas leak or fault exists or is suspected, turn the boiler and gas supply off and consult the local gas company or your Installer/Service provider.
In case of power supply failure
The boiler no longer operates. As soon as power supply is restored, the boiler will restart automatically.
In case of loss of water in the system
CAUTION: The boiler is installed as part of a sealed system which must only be drained and filled by a competent
person. If the pressure shown on the pressure gauge is less than 1 bar the system must be filled up immediately.
Important notice: A central heating system cannot operate satisfactorily unless it is properly filled with water and
unless the air initially contained in the piping systems has been properly bled off. If these conditions are not satisfied, air noise will occur within the system and the boiler may fail to operate.
Air in the heating system
Persistent air in the heating system may indicate leaks in the system or corrosion taking place. Call your Installer /Service provider.
Overheating safety
In the event of problem, the overheat safety device causes safety shutdown of the boiler. If this happens, call your Installer/Service provider.
CONTROLS AND LIGHTING
The control panel is located behind the drop down front door. The controls on this panel allow the boiler to be started, shut down, controlled and monitored during use, see diagram 1.
Controls
1 - Timeclock 5 - Summer/Winter switch 2 - Pressure gauge 6 - Reset button 3 - Hot water temperature control 7 - Mains On/Off switch 4 - Heating temperature control 8 - Digital display
Diagram 1
3
Make sure that:
• The boiler is connected to the electrical supply.
• The boiler gas service cock is open.
• The pressure gauge reads between 1 and 2 bar. The boiler is now ready to start.
To start the boiler
• Place switch (7) in the On position “I”
• Place switch (5) in the desired Summer or Winter position
To stop the boiler
Place switch (7) to the Off position “O”. If the boiler is to be out of operation for a long period, turn off the gas service cock.
Setting to ‘Summer’ mode (Hot water only)
Place switch (5) in the Summer position
Setting to ‘Winter’ mode (Heating and hot water)
Place switch (5) to the Winter position Adjust the heating temperature control (4) to the desired temperature. Adjust the domestic hot water control (3) to the desired hot water temperature. The heating will operate accord­ing to the requirements of the timeclock and/or room thermostat if fitted or, will operate according to the system requirements. Domestic hot water always has priority over central heating.
Timeclock
The boiler can be switched on and off automatically by the built-in timeclock. To set the timeclock, proceed as follows: (refering to diagram 1) Press in the tappets corresponding to the time you want the boiler to be on. For example if you want the boiler to be on between 7 AM and 9 AM, push in all the tappets between 7 and 9. Set the times you want the boiler to be on for the rest of the day in the same way.
Note: The timeclock setting is in 24 hour format. Therefore, if you want the boiler to come on at 2 PM you must push
in the tappets at 14. To set the correct time rotate the clock by hand until the current time is indicated by the arrow at the top of the clock. To operate the boiler according to your selected times, place the grey lever to the position. To have the boiler permanently ‘ON’, place the grey lever to the ‘I’ position. To have the boiler permanently ‘OFF’, place the grey lever to the ‘0’ position.
Safety lockout
In the event of a safety lockout, the digital display will show ‘F1’. Reset boiler by pressing the RESET button (6).
IMPORTANT: If safety lockout occurs frequently, or if any other fault is indicated, contact your Installer/Service Provider.
Draining and filling
CAUTION: The boiler is installed as part of a sealed system which must only be drained and filled by a competent
person.
Note: If there is persistent loss of system pressure, you must consult your Installer/Service Provider.
If the pressure shown on the pressure gauge is less than 1 bar the system must be filled immediately.
Heating safety valve
CAUTION: A safety valve with a discharge pipe is fitted to this boiler.
The valve MUST NOT BE TOUCHED except by a competent person. If the valve discharges at any time, switch the boiler off and isolate it from the electrical supply. Contact your Installer/Service Provider.
Servicing/Maintenance
To ensure the continued efficient and safe operation of the boiler, it is recommended that it is checked and serviced at regular intervals. The frequency of servicing will depend upon the installation conditions and usage but, in general, once a year should be enough.
Cleaning
The boiler casing can be cleaned with a damp cloth followed by a dry cloth to polish. Do not use abrasive or solvent cleaners.
Boiler casing
CAUTION: Do not remove or adjust the casing in any way, as incorrect fitting may result in faulty operation.
If in doubt, contact your Installer/Service Provider.
4
INSTALLATION INSTRUCTIONS
Introduction
The Protherm 100 e is a wall mounted combination boiler providing central heating and instantaneous domestic hot water.
The boiler is of the II
2H3+
category for use with Natural gas (G20) as distributed in the United Kingdom, or with
Butane or Propane gas (G30/G31) with the appropriate conversion kit.
Conversion kit:
Conversion Part No.
Natural gas (G20) to G30/G31 . . . . . . . 92321165
Modification must only be carried out by a suitably qualified engineer.
Boilers burning LPG or similar gases MUST NOT be fitted in basements or below ground level.
These instructions should be carefully followed for the safe and economical use of your boiler.
The boiler has a fan assisted, balanced, flue which both discharges the product of combustion to, and draws the combustion air from the outside of the building.
Accessories
A range of accessories are available including, vertical flue components. For further information, contact you near­est stockist.
Gas Safety (Installation and Use) Regulations
In the interests and that of gas safety, it is the law that ALL gas appliances are installed and serviced in by a competent person in accordance with the above regulations.
Gas leak or fault
If a gas leak or fault exists or is suspected, turn the boiler and gas supply off and consult the local gas company or your Installer/Service Provider.
Boiler controls
The control panel, located at the lower front of the boiler, allows the boiler to be started, shut down, controlled and monitored during use, refer to ‘Users Instructions’.
5
TECHNICAL DATA
Protherm 100 e
CE Certification . . . . . . . . . . . . . . . . . . . . . . . . n° . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 AU 2915
Class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . II
2H3+
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C12,C
32
Gas type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G20 . . . . . . G30 . . . . . . . . G31
Max. Heat Input . . . . . . . . . . . . . . . . . . . . . . . . kW . . . . . . . . . . . . . . . . . 30.5 . . . . . . 30.5 . . . . . . . . 30.5
Min. Heat Input . . . . . . . . . . . . . . . . . . . . . . . . . kW . . . . . . . . . . . . . . . . . 12.1 . . . . . . 12.1 . . . . . . . . 12.1
Max. Heat Output . . . . . . . . . . . . . . . . . . . . . . . kW . . . . . . . . . . . . . . . . . 27.4 . . . . . . 27.4 . . . . . . . . 27.4
Min. Heat Output . . . . . . . . . . . . . . . . . . . . . . . kW . . . . . . . . . . . . . . . . . 10.0 . . . . . . 10.0 . . . . . . . . 10.0
GAS SUPPLY PRESSURE
Burner pressure . . . . . . . . . . . . . . . . . . . . . . . mbar . . . . . . . . . . . . . 2.1 – 15.0 . . 3.8 – 28.8 . 4.1 – 36.7
Nominal pressure . . . . . . . . . . . . . . . . . . . . . . mbar . . . . . . . . . . . . . . . . 20 . . . . . . . . 29 . . . . . . . . . . 37
Injectors diameter . . . . . . . . . . . . . . . . . . . . . mm . . . . . . . . . . . . . . . . 1.2 . . . . . . . 0.73 . . . . . . . . 0.73
GAS CONSUMPTION
Qmax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . m3/h . . . . . . . . . . . . . . . . . 3.2 . . . . . . . . 1.1 . . . . . . . . . . 1.4
Qmin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . m
3
/h . . . . . . . . . . . . . . . . . 1.3 . . . . . . . . 0.5 . . . . . . . . . . 0.6
Air flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . m
3
/h . . . . . . . . . . . . . . . . . 135 . . . . . . . 135 . . . . . . . . 135
EFFICIENCY
Nominal efficiency . . . . . . . . . . . . . . . . . . . . . . % . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89,8
Efficiency at 30% load . . . . . . . . . . . . . . . . . . . % . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86,7
HEATING
Temperature range . . . . . . . . . . . . . . . . . . . . . . °C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 - 85
Expansion vessel . . . . . . . . . . . . . . . . . . . . . . . . l . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Expansion vessel pressure . . . . . . . . . . . . . . . bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Max. working pressure . . . . . . . . . . . . . . . . . . . bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Max. system temperature . . . . . . . . . . . . . . . . . °C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Max. system capacity . . . . . . . . . . . . . . . . . . . . . l . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
HOT WATER
Flow rate at 30°C temperature rise . . . . . . . . l/min . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.1
Flow rate at 35°C temperature rise . . . . . . . . l/min . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.3
Min. water flow . . . . . . . . . . . . . . . . . . . . . . . . l/min . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Max. supply pressure . . . . . . . . . . . . . . . . . . . . bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Min. supply pressure . . . . . . . . . . . . . . . . . . . . bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5
Temperature range . . . . . . . . . . . . . . . . . . . . . . °C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 – 60
ELECTRICAL DATA
Voltage/frequency . . . . . . . . . . . . . . . . . . . . . V/Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ~230/50
Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.8
Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180
Level of protection . . . . . . . . . . . . . . . . . . . . . . IP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP 44
DIMENSIONS
Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 450
Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 880
Depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 370
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
CONNECTIONS
Heating flow/return . . . . . . . . . . . . . . . . . . . . . . mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Domestic Water inlet/outlet . . . . . . . . . . . . . . . mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Gas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Flue products outlet/air inlet ∅ . . . . . . . . . . . . . . mm . . . . . . . . . . . . . . . . . . . . . . horiz. 60/100 – vert. 80/125
Horizontal flue length min/max . . . . . . . . . . . . m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.3 – 3
Vertical flue length min/max . . . . . . . . . . . . . . . m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 – 11,5
HEAT OUTPUT PRESSURE
G20 G30 G31
kW . . Btu/hr . . . . mbar . . mbar . . . mbar
10 . . . 34 120 . . . . 2.1 . . . . 3.8 . . . . . 4.1
11 . . . 37 532 . . . . 2.5 . . . . 4.6 . . . . . 5.2
12 . . . 40 944 . . . . 3.0 . . . . 5.5 . . . . . 6.4
13 . . . 44 356 . . . . 3.6 . . . . 6.6 . . . . . 7.8
14 . . . 47 768 . . . . 4.2 . . . . 7.7 . . . . . 9.2
15 . . . 51 180 . . . . 4.8 . . . . 9.0 . . . . 10.9
16 . . . 54 592 . . . . 5.4 . . . . 10.3 . . . 12.6
17 . . . 58 004 . . . . 6.2 . . . . 11.7 . . . 14.5
18 . . . 61 416 . . . . 6.8 . . . . 13.2 . . . 16.4
19 . . . 64 828 . . . . 7.5 . . . . 14.7 . . . 18.3
HEAT OUTPUT PRESSURE
G20 G30 G31
kW . . Btu/hr . . . . mbar . . mbar . . . mbar
20 . . . 68 240 . . . . 8.2 . . . . 16.2 . . . 20.3
21 . . . 71 652 . . . . 9.0 . . . . 17.7 . . . 22.3
22 . . . 75 064 . . . . 9.8 . . . . 19.3 . . . 24.4
23 . . . 78 478 . . . 10.7 . . . . 21.0 . . . 26.6
24 . . . 81 888 . . . 11.6 . . . . 22.7 . . . 28.9
25 . . . 85 300 . . . 12.6 . . . . 24.5 . . . 31.2
26 . . . 88 712 . . . 13.6 . . . . 26.2 . . . 33.5
27 . . . 92 124 . . . 14.7 . . . . 28.1 . . . 35.8
27.4 . . 93 489 . . . 15.0 . . . . 28.8 . . . 36.7
6
Diagram 2
Diagram 3
1 – Heating flow (pipe diameter 22 mm) 2 – Hot water outlet (pipe diameter 15 mm) 3 – Gas inlet (pipe diameter 22 mm) 4 – Cold water mains inlet (pipe diameter 15 mm)
5 – Heating return (pipe diameter 22 mm) 6 – Wall 7 – Wall fixings 8 – Outer cover
DIMENSIONS AND PRESSURE AVAILABLE
7
1 – Air pressure switch 2 – Fan 3 – Heat exchanger 4 – Burner 5 – Gas valve 6 – Expansion vessel 7 – Pump 8 – Water flow sensor 9 – Pressure gauge connection 10 – By-pass pipe 11 – Safety valve 12 – Heating return 13 – Domestic cold water inlet 14 – Gas inlet
15 – DHW thermistor 16 – DHW outlet 17 – Automatic by-pass 18 – Heating flow 19 – Drain 20 – Microswitch 21 – Loss of water pressure switch 22 – 3-way valve 23 – Differential valve 24 – Microswitch 25 – Secondary heat exchanger 26 – CH temperature sensor 27 – High limit thermostat
Diagram 4
BOILER SCHEMATIC
8
INSTALLATION SECTION
Clearances
The boiler can be installed with the following clearances:
25 mm either side of the boiler 50 mm to the front of the boiler 300 mm below the boiler 200 mm above the boiler
The above clearances are minimum clearances, consideration must be given to allow adequate space for servicing. The recommended servicing clearances are:
50 mm either side of the boiler 600 mm to the front of the boiler 300 mm below the boiler 200 mm above the boiler
Terminal position
The minimum acceptable spacings from the terminal to obstructions and ventilation openings are shown in dia­gram 5 below:
Diagram 5
Minimum dimensions (in mm) for the positioning of flue terminals
a Under a window . . . . . . . . . . . . . . . . . . . . . . . . 300
b Under an air vent . . . . . . . . . . . . . . . . . . . . . . . 300
c Under a gutter . . . . . . . . . . . . . . . . . . . . . . . . . . 75
d Under a balcony . . . . . . . . . . . . . . . . . . . . . . . . 300
e From an adjacent window . . . . . . . . . . . . . . . . . 300
f From an adjacent air vent . . . . . . . . . . . . . . . . . 300
g From vertical drain pipes or soil pipes . . . . . . . . 75
h From an external corner of the building . . . . . . 300
i From an internal corner of the building . . . . . . . 300
l From the ground or from another floor . . . . . . . 300
m Between two terminals vertically . . . . . . . . . . 1500
n Between two terminals horizontally . . . . . . . . . 300