Prokit's Industries NT-3200 User Manual

NT-3200
MINI POCKET TESTER WITH VARIOUS ADAPTORS
INSTRUCTION MANUAL
Thank you for purchasing the Pro’sKit’ Mini Pocket Tester with various adaptors. The unit is a Mini Pocket Tester for identify­ing cables in a Multi Dwelling Unit. The cable installer uses the unit to place a DC current through one end of the desired
cable and identies the cable at the end with the detachable
Tone Detector. Before using the Mini Pocket Tester and vari­ous adaptors, please read the following manual completely.
Features and Benets
Tones out cables by inserting a DC current into a coaxial cable at one end and detects that cable from others in a remote loca­tion by attaching the audio toning detector to the other end.
Features
• Improved head design with rugged push-on male F connector
• Easily viewable short circuit indicator
• Loud audio level for noisy environments
• Time-saving push-on female connector on audible toner
• Easily stores in shirt pocket or tool pouch
The unit is equipped with a short circuit detector. The LED is located on the head of the transmitter section. If a DC short circuit exists in the cable, the LED will light up. Many high qual­ity splitters used for MDU application are short circuit to DC; therefore, if these splitters are in the cable line, the LED will light up. With the additional wide range of optional adaptors, it can test telephone, LAN, audio, security, or virtually any other type of wire or cable easily.
Contents
• NT-302 Mini Pocket Tester • 2 x RJ45 to F male
• 2 x F-type female to BNC female • 2 x RJ11 to F male
• 2 x F-type male to F-type male • 2 x F-type female to RCA male
• 2 x BNC female to F-type male • 2 x F female to PAL Female
• 2 x RCA female to F-type male • 2 x F female to F Push-on male
• 2 x F-type female to BNC male
• 1 x F-type female to F-type female
2
Warning: This tool should never be used on live electrical circuits. It is not protected against electric shock!
Always use OSHA/ANSI or other industry approved eye protection when using tools. This tool is not to be used for purposes other than intended. Read carefully and un­derstand instructions before using this tool!
Short circuit LED
Male F type
push-on tting
Main section
Battery chamber access cap
Detachable tone detector
3
Tone detector
OPERATING INSTRUCTIONS
F male to RCA female
RCA cable F male
to RCA female
23456
F double connector
1
Common use for cable testing instruction:
NT-302
1. Take the NT-302 mini pocket tester, then unscrew the “tone” detector which is conveniently stored in the base section
2. Put a double female “F” connectors into the top of NT-302
push-on tting port, and put another type of connector
which one end matching the desired test cable plug.
3. Connect the connector with desired test cable properly
4. Add a type of connector which matches both ends of de­sired test cable end plug and the “tone” detector
5. Put the “tone” detector to the matching connector
6. When the desired test cable short circuit was found, the LED lights up and the tone will sound
Cable in an MDU testing instruction:
1. Take the NT-302 Mini Pocket Tester, then unscrew the “tone” detector which is conveniently stored in the base section
2. The main section of NT-302 has a male “F” push-on tting. Attach this push-on tting to a female “F” port on an apart-
ment wall plate.
3. Tough the “tone” detector to each one of the cables at the remote location. When the correct cable from the transmit­ter location is found, the tone will sound.
Note: To replace the battery, unscrew the battery chamber access cap above the tone detector. Battery type: 23A-12V
4
Notice: If you test other cables, please follow
below SOP for reference.
SOP (Steps of procedure)
BNC cable 1 (Parts)
RCA cable 1 (Parts)
BNC cable 2 (Assembly)
RCA cable 2 (Assembly)
5
Loading...
+ 9 hidden pages