TABLE OF CONTENTS
Product Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5
Factory Presets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Parts List and Exploded View . . . . . . . . . . . . . . . . . . . . . .7
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
CHANNEL
FUNCTION
TIME
H:M
M:S
_ _ _ _
_
SCAN
SCAN
Jack in The Box
Logo Button
Channel/Function
Display
Channel Buttons & LED’s
Remove/ Cancel Button
UP/Scan Button
DOWN/Scan
Button
Hour:Minute LED
Minute:Second LED
Numeric
Message Display
Product Identification
LIMITED WARRANTY
This product is warranted to be free from defects in material and/or
workmanship for a period of 1 year from date of original installation, not
to exceed 18 months from the date of manufacture.
Any component which proves to be faulty in material and/or
workmanship will be replaced or repaired (at the option of Prince Castle,
Inc.) without cost to the customer for parts and labor. This equipment is
portable; charges for on-location service (e.g., trip charges, mileage) are
not included in the provisions of this warranty.
This warranty is subject to the following exceptions/conditions:
• Use of any non-genuine Prince Castle parts voids this warranty.
• All labor to be performed during regular work hours. Overtime
premium (the incremental amount) will be charged to the customer.
•
Damage caused by carelessness, neglect and/or abuse (e.g., dropping,
tampering or altering parts, equipment damaged in shipment, by fire,
flood or an act of God) is not covered under this warranty.
• All problems due to operation at voltages other than that specified on
equipment nameplates are not covered by this warranty. Conversion
to correct voltage is the customer’s responsibility.
•
This equipment must be serviced by Prince Castle Authorized Service
Agency or a Prince Castle Service Technician during the warranty
period.
841-500revC
Printed in USA 1/06 © 2006

CHANNEL
FUNCTION
TIME
H:M
M:S
_ _ _ _
_
SCAN
SCAN
1
5
4
3
2
8
7
6
Multi-Function Timer
Model 841-T8JIB
Electrical Specifications
Important
Installation
Safety Information
Remove the unit from the carton and inspect for signs of damage. If
there is damage to the unit:
• notify the carrier within 24 hours of delivery
• save carton and packaging materials for inspection purposes
• contact your local dealer, or if purchased directly, the Prince Castle
Sales Department at 800-722-7853 or 1-630-462-8800 to arrange for a
replacement unit.
Use the bracket holes on back of unit as a template, mark the mounting
holes location. Install unit using hardware provided.
Plug the power cord into the proper electrical receptacle. All electrical
connections must be in accordance with local electrical codes and any
other applicable codes.
When the unit is plugged into the proper electrical receptacle,
the display will look like this and the unit will be in RUN mode.
The 841-T8JIB Series multi-function timers feature multiple channels
that can be programmed to perform the following timing functions on
each channel: Total Cook Time & Duty During Cook Time.
Each channel can be programmed separately and used simultaneously.
The alphanumeric display shows the current channel and function
being monitored. Each channel button features a corresponding LED to
indicate time remaining for the channel closest to completing its cycle.
Description
Prince Castle reserves the right to change specifica-
tions and product design without notice. Such revisions do
not entitle the buyer to corresponding changes, improvements,
additions or replacements for previously purchased equipment.
WARNING
Indicates information important to the proper operation of the unit. Failure to observe may result in damage to the equipment and/or severe bodily injury or
death.
CAUTION
Indicates information important to the operation of
the unit. Failure to observe may result in damage to
the equipment.
Model No. Volts Watts Amps Hz
841 120 10 max 0.1 50/60
Pushing the channel button activates it. “Traffic signal” style LED’s
change color as the timing process counts down, then an audible alarm
coupled with a flashing LED alerts the operator when timing is complete.
The timer comes shipped complete with a mounting bracket and
menu stickers to identify channels.
Printed in USA 1/06 © 2006
2
841-500rev

Multi-Function Timer
Model 841-T8JIB
Operation
CHANNEL
FUNCTION
TIME
H:M
M:S
:25
SCAN
SCAN
1
5
4
3
2
8
7
6
1
Press the desired CHANNEL Button to start the timing cycle.
- Display will show the timer channel number and product name
- The hour:minute (H:M) or minute:second (M:S) LED will light
- Timer will start to count down the pre-programmed time to 0
To cancel the most recently started timing function, press the
Remove/Cancel button then press the desired channel button
within 5 seconds.
2
When cycle is complete, the display flashes :00 and the
alarm will sound.
Press the CHANNEL button with the flashing red LED to
cancel the alarm and end the cycle.
3
CHANNEL
FUNCTION
TIME
H:M
M:S
:25
SCAN
SCAN
1
5
4
3
2
8
7
6
All channels can be activated and operating at the same time.
Press the SCAN/UP or SCAN/DOWN buttons, or any active
CHANNEL button, to check the time values for a channel. The
channel number and time value will appear in the display.
If no other button is pressed within 5 seconds, the display will
show the channel with the least remaining cycle time.
CHANNEL
FUNCTION
TIME
H:M
M:S
_ _ _ _
_
SCAN
SCAN
1
5
4
3
2
8
7
6
The alarm sound level may be adjusted with the unit in RUN
mode. Press and hold the JACK IN THE BOX LOGO Button, then
within 6 seconds, press the SCAN/UP or SCAN/DOWN Arrow
button to adjust the alarm level accordingly.
Alarm levels can be set from S-0 thru S-3, with S-3 being the
loudest.
NOTE: Each
channel can have
up to 3 batches
running at the
same time.
2
If the product is programmed for more than one duty function,
the channel LED will turn yellow and the alarm will sound for 5
seconds.
The Channel/Function display will alternate between the first
duty function and the next duty function to be performed.
Perform the function and press the appropriate CHANNEL button.
CHANNEL
FUNCTION
TIME
H:M
M:S
:00
SCAN
SCAN
1
5
4
3
2
8
7
6
CHANNEL
FUNCTION
TIME
H:M
M:S
:00
SCAN
SCAN
1
5
4
3
2
8
7
6
CHANNEL
FUNCTION
TIME
H:M
M:S
:00
SCAN
SCAN
1
5
4
3
2
8
7
6
:00
SCAN
SCAN
1
5
4
3
2
8
7
6
CHANNEL
FUNCTION
TIME
H:M
M:S
:00
SCAN
SCAN
1
5
4
3
2
8
7
6
CHANNEL
FUNCTION
TIME
H:M
M:S
:00
SCAN
SCAN
1
5
4
3
2
8
7
6
CHANNEL
FUNCTION
TIME
H:M
M:S
:00
SCAN
SCAN
1
5
4
3
2
8
7
6
:00
SCAN
SCAN
1
5
4
3
2
8
7
6
The channel LED
will blink when
multiple batches
are activated.
1 – COOK
1 – COOK1 – COOK1 – COOK
1 – SPICY CHIKN
1 – SPICY CHIKN 1 – SPICY CHIKN 1 – SPICY CHIKN
1 – ROTATE 1 – ROTATE 1 – ROTATE
1 – ROTATE
1 – COOK1 – COOK1 – COOK1 – COOK
841-500revC 3 Printed in USA 1/06 © 2006