The symbol CE conforms with European Directive R&TTE 99/05CE
TECHNICAL INSTALLATION MANUAL
FOR AUTOMATIC
Before installing, thoroughly read this manual that is an integral part of this
Kit. Prastel S.p.A. declines any responsibility in the event current standards
in the country of installation are not complied with
SAFETY WARNINGS FOR INSTALLATION AND USE ................................................... 15
2
UNIK2E230 V2
ENGLISH
ISUNIK2E230v2_GB_10_12.doc
1. INTRODUCTION
UNIK2E230 is a universal self-learning control unit especially designed for the automatic control of 230VAC
powered, 1 or 2 motor driven accesses. It is fitted with an innovative self-learning procedure allowing rapid
installation and four trimmers for fine adjustment of the main parameters; force, pause time, obstacle
detection sensitivity and out of phase closing when two motors are used.
The following are available:
- simplified programming, thanks to which the unit automatically performs a learning operation to acquire
running time and determine slow-down setting at 85% of opening and closing runs;
- A professional programming in which the installer can determine the instant in which the gate starts to
slow-down, the enabling of the pedestrian opening via radio, the safety device trigger mode.
2. MAIN FEATURES
•
Management and control of 230VAC (max 400W) powered, 1 or 2 motor-driven automated accesses
•
Motors closing offset adjustable from 0 to 15 seconds using trimmers
•
Opening motors delay settable at 0 or 3 seconds
•
Double limit switch input open close
•
Motor force (speed) adjustable from 50-100%.using a trimmer.
0.1 to 3.0” obstacle detection triggering time adjustment via trimmer.
•
Initial settings using dip-switches
•
Signalling LEDs (8)
•
Expansion for electric lock 12V 15W max (optional board ELU, with optional relay)
•
Expansion for courtesy light (optional board LCU)
•
Built-in 433MHz rolling-code receiver with 180 memorisable codes
•
Built-in flashing logic management
•
Flash microprocessor re-programmable on-board via serial interface.
•
Programming and control of the control unit using a portable terminal GTSYSTEM (optional)
•
Built to European reference Directive Standards (R&TTE 99/05/CE)
DECLARATION OF CONFORMITY
Prastel S.p.A. declares that UNIK2E230 IS IN ACCORDANCE with the 99/05/EC (R&TTE) direcitve
The complete declaration of conformity is available in Prastel or to the internet address www.prastel.it
3. TECHNICAL SPECIFICATIONS
Transformer power supply: primary230 / secondary 18V 20VA / secondary12V 20VA
Control unit power: 230VAC
Motor output: 2 x 400W
Max current peak of motor: Max 8 Ampere
Accessories power: 24 VDC - 500 mA protected by fuse (see info page 13)
Environmental operating temperature : -20°C / + 55 °C
Programming parameters: memorised in EEPROM
Functions handler: microprocessor with watch-dog
BOX IP rating: IP54
3
UNIK2E230 V2
INITIAL FACTORY SETTINGS
ENGLISH
ISUNIK2E230v2_GB_10_12.doc
4. CONNECTION AND SET UP OF THE CONTROL UNIT
a) Before installing the UNIK2E230 control unit, read the “General safety warnings and
notes” (page 15).
b) Mount a differential thermo-magnetic circuit breaker 6A (IC=30mA) on the mains supply
as specified in the current reference standards (IC = differential current).
c)
*
Fix the box using the special fixing holes.
d) * Place the supplied cable-ways and insert the cables keeping the power and supply
cables separate from each other.
e) Connect the motors to the terminal blocks “MOT1” e “MOT2”; if only one motor is used
connect it to the terminal blocks “MOT1”.
f) Connect the external accessories making sure that the total of the average absorption
of all the connected accessories is less than the maximum current available (see info
page 13).
g) ATTENTION: Connect the limit switches if present, otherwise do not bridge inputs
FC1, FC2, FO1, and FO2 in the terminal board.
h) ATTENTION: To avoid noisy or irregular operating when the control panel is used
with hydraulic operators, the following is recommended:
• set the Force to 100% (“FOR” trimmer completely clockwise).
• do not use the slow-down (carry out the professional learning procedure).
• do not use the obstacle detection (trimmer OBS to MAX),
i) During the learning with no electric limit switches present and with the obstacle
detection disabled (e.g. with hydraulic operators), or else with no mechanical
STOP (strike plate) present, to define the manoeuvre times:
• Press pushbutton 1 of the remote control or pushbutton P1/SET to stop the gate in the
desired position.
• Press pushbutton 2 of the remote control or pushbutton P2/SET to stop the gate in the
desired position.
j) Check the correct connection and operation of all the accessories connected to the
terminal board.
NOTE:
*
When the control panel is mounted directly onto the operator with the special control
panel-holder, these two points are not relevant.
If there is no programming, the control unit will operate as follows:
• Step by step mode with automatic closing disabled
• No slow-down
• Closing safety present
• No opening safety
• Obstacle detection trigger time (OBS) 1 second
• 3 second opening and closing time of the motors
• Pushbutton 1 of transmitters enabled
• Safety test disabled
• Kick-back disabled
4
UNIK2E230 V2
30 31 32 33
34
ENGLISH
4.1 GENERAL DIAGRAM OF SETTINGS AND CONNECTIONS
ISUNIK2E230v2_GB_10_12.doc
5