Technical Manual for the Installer
CONTROL UNITFORONEMOTOR
12VDC
UNIK1E
Attention!!Beforeinstalling, carefully read this manual.
N.B.
- Stateurop declines every responsib
the Country where the installation is made
The CE mark conforms to the European directive R&TTE 99/05CE
ility in case of not observance of the normative in force in

ENGLISH
SUMMARY
Title Description Page
• INTRODUCTION
1
• MAIN FEATURES
2
• TECHNICAL SPECIFICATIONS
3
• CONNECTING AND TURNING ON THE CONTROL UNIT
4
• EASY LEARNING PROCEDURE
5
• PROFESSIONAL LEARNING ROUTINE
6
3
3
3
4
5
7
7
8
9
10
• RADIOTRANSMITTERS PROGRAMMING AND ERASING
• SAFETIES AND OPERATING LOGIC
• CONTROL UNIT OPERATION
• Turning ON
• Automaticoperation
• Step-by-step operation
• Pedestrian opening
• Obstacle detection
• Flashing warning light
• Quick closing after photocell triggering
• Slowdown
• Emergency battery
• PROGRAMMING BY GTSYSTEM
8
9
9
9
9
9
9
10
10
10
10
10
10
11
• TROUBLESHOOTING
• SAFETY WARNINGS
11
12
2

ENGLISH
1. INTRODUCTION
UNIK1E is a universal self-learning control unit especially designed for the automatic control of 12VDC, 1 motor
driven accesses. Its innovative self-learning procedure makes for quick and easy installation and its three
trimmers permit fine adjustment of all main parameters, namely force, pause time and obstacle detection
sensitivity.
Are available :
- a quick self-learning routine thanks to which the unit automatically performs a learning operation to acquire
running times and determine slow down setting at ninety percent of opening and closing runs;
- a professional routine thanks to which the installer performs slow down triggering, remote pedestrian
opening, photocell-triggered instant reverse or reverse upon release.
2. MAIN FEATURES
• Management and control of 12/24VDC powered
• Quick and professional self-learning routines for acquisition of running and slow down times and of the
presence of safeties
• 50-100% force adjustment via trimmer
• Motor speed adjustment
• 0 to 60” stand-by time adjustment via trimmer
• 0.1 to 3.0” obstacle detection triggering time adjustment via trimmer
• Customisable partial opening (for pedestrian transit)
• 12V 15W electric lock expansion (optional ELU)
• Courtesy light expansion (optional LCU)
• Setting up for 12V 1.2Ah battery operation for optional emergency running
• Incorporated 433MHz rolling-code receiver
• 40 remote code storage capacity
• Reprogrammable on-board Flash microprocessor via serial interface
• Control unit programming via GTSYSTEM
• Built to European reference Directive Standards (R&TTE 99/05/CE)
3. TECHNICAL SPECIFICATIONS
Control Unit power: 230 VAC
Motor output: 12VDC 80Watt (24VDC with optional transformer TRT12-24V100VA)
Motor Current: Max 10 Ampere
Accessories power: 12 VDC - 150 mA
Operating temperature: -20°C / + 55 °C
Programmable parameters:in EE-PROM
Functions manager: microprocessor with watchdog
3

ENGLISH
4. CONNECTING AND TURNING ON THE CONTROL UNIT
• Before installing the UNIK1E control unit carefully read “General Safety Precautions”.
• Secure the box in place through the appropriate mounting holes.
• Make sure the power line is fitted with an appropriate disconnector / isolating switch as required by
prevailing reference Provisions and Standards.
• Fit on the fairleads provided and route the cable making sure to keep power lines separate from control
ones.
• Connect power and control lines according to the diagram and instructions given below.
• Make sure that all terminal board inputs are correctly connected and operative.
Obstacle
Force Trimmer
GTSYSTEM
P1/SET learning key
Sensitivity
Trimmer
P2/RADIO learning key
Radio channel
selector
Safeties test
selector
Radio Antenna
Photocell
Controls
ELU Electro-lock
expansion
Motor
10A battery fuse
Transformer
Secondary
Battery