MT15000/2 – V1.0 ENGLISH
CONTENTS
Information and Recommendations ................................................................................................ 3
Specifications .................................................................................................................................... 3
1) MT15000/2 .....................................
2) MT15000/2-M .................................
3) PROTECTION ................................
Wiegand or data clock device connection ..................................................................................... 4
MT15000/EXT4 and MT15000/EXT4-M extension modules connection ...................................... 5
Connecting a fail-safe electric strike and electro magnet ............................................................ 6
Connecting a standard strike .......................................................................................................... 7
MT15000/2 control unit connection to Ethernet network.............................................................. 8
SWAMIGO3 dongle installation ....................................................................................................... 9
Terminal block features .................................................................................................................. 10
"Reset" buttons use ........................................................................................................................ 11
Dear Customer,
You have purchased a MT15000/2 control unit produced by PRASTEL France.
We thank you for your interest in our products and wish you all the best with the installation procedure.
PRASTEL France
p.2/11
ZI Athélia II, 225 Impasse du Serpolet, 13704 LA CIOTAT Cedex, France
PRASTEL France SARL
Tel : +33.442.98.06.06 – Fax : +33.442.04.53.51 – infos@prastelfrance.fr
MT15000/2 – V1.0 ENGLISH
INFORMATION AND RECOMMENDATIONS
In accordance with UTE C00-200 European Directive describing Directives 89/336CEE and 92/31 EEC,
MT15000/2 complies with the following standards:
- NF EN 50081-1 on electromagnetic emissions and
- NF EN 50082-1 on electromagnetic sensitivity.
Wiring recommendations: the cables used to connect readers, network and other devices must be installed in
accordance with the instructions for Level 2, as set forth in standard NF EN 61000-4-4 (protected environment).
This product must be installed by a qualified company. Inappropriate installation and use may entail a risk of
electric shock or fire. Please read these technical instructions before installing the product and follow assembly
instructions thereof.
All internal capacitors in the 220V version will lose charge at a healthy level after 60 seconds once power
has been turned off, under normal conditions. However, in the event of a failure, the charge may be maintained for much longer and adequate precautions are required before using the product.
SPECIFICATIONS
1) MT15000/2
Maximum consumption ............................... 300 Ma
Power voltage ............................................. 9 – 14VDC
Weight ........................................................ 150 g
Dimensions ................................................. 157 x 108 x 30 mm
Operating temperature ................................ - 20°C to + 50°C
Relay outputs .............................................. 1A / 12V – 1A / 24V
2) MT15000/2-M
Weight, with housing ................................... 4 Kg
Housing dimensions ................................... 330 x 330 x 90 mm
Operating temperature ................................ - 20°C to + 50°C
Integrated 220V power supply:
Output voltage............................................. 12V
Maximum output current ............................. 5A
Battery connection ...................................... 13,6V
3) PROTECTION
The control unit is fitted with a fuse on 12V input inside the housing. Check the fuse if the power LED does not light
up when the module is under power.
p.3/11
ZI Athélia II, 225 Impasse du Serpolet, 13704 LA CIOTAT Cedex, France
PRASTEL France SARL
Tel : +33.442.98.06.06 – Fax : +33.442.04.53.51 – infos@prastelfrance.fr
MT15000/2 – V1.0 ENGLISH
WIEGAND OR DATA CLOCK PROTOCOL DEVICE CONNECTION
Information :
5 wires (3 pairs recommended)
Max distance : 100m
Cable type : 0,6mm (SYT advised)
Screen : Optional
Warning
Do not connect the jumper wires near other high voltage or current cables, including 220V and higher.
Note:
Each reader may support a separate technology
Example: Reader 1 in Wiegand, Reader 2 in Data Clock
WIEGAND :
o proximity reader
(PRASTEL, HID, STID, INDALA, …)
o keypad (PRASTEL, XPR, …)
o Biometric readers (PRASTEL, …)
o Radio receivers (PRASTEL, …)
o DALLAS (via interface)
DATA CLOCK :
o Magnetic strip readers
o Bar codes readers
o Proximity reader
o Radio receivers
Warning
If you use an external power supply for your
proximity readers, please be sure to connect
all different masses with the one on the
control unit.
p.4/11
ZI Athélia II, 225 Impasse du Serpolet, 13704 LA CIOTAT Cedex, France
PRASTEL France SARL
Tel : +33.442.98.06.06 – Fax : +33.442.04.53.51 – infos@prastelfrance.fr