FERRUPS must be ordered using a Configure To Order (CTO) Number that reflects the cabinet style, VA
rating, voltages, runtime, and other options pertaining to the FERRUPS configuration. As you select the
options needed, they will become part of the CTO number.
Sample CTO Number: RQ000AA0A0A0A0A. See page 3.1k-5 for a CTO worksheet.
External bypass switches and other external options will need to be ordered as separate line items.
Base Unit
Base Model, Frequency, Cabinet StyleCTO Order CodeBase Price
QFER2.1kVA, 50 Hz Rackmount (Long Cabinet)RS$4,067
QFES2.1kVA, 50 Hz Rackmount (Short Cabinet)RP$4,227
Input / Output Voltage
Input VoltageOutput VoltageCTO Order CodeBase Price
2202204$0
2302305$0
2402406$0
Battery and Battery Charger
FER Rackmount (Long Cabinet)
Battery ConfigurationCabinet / Battery ChargerCTO Order CodeOption Price
14 minute internal (35 m half load)long / standard0$432
Set up for internal (less batteries)long / standard3$216
set up for external battery pack
6 minute internal (17 m half load)short / standard0$432
Set up for internal (less batteries)short / standard3$216
set up for external battery pack
1
Includes External Battery Connector
Order desired external battery pack as a separate line. See page 3.1k-4.
1
1
long / standard4$ 0
short / standard4$ 0
Internal Maintenance Bypass Switch
Internal Maintenance Bypass SwitchCTO Order CodeOption Price
No internal maintenance bypass switch option available
1
External maintenance bypass switch available for hardwired systems.
Order desired maintenance bypass switch as a separate line item on your order. See page 3.1k-4.
1
0$0
All Prices F.O.B. Necedah, Wisconsin U.S.A. in U.S. dollars.
Product and pricing subject to change without notice.
3.1k - 1
QFER(S)3.1kVA CTO Configuration Guide
Input Connection
Input Voltage SelectedInput ConnectionCTO Order CodeOption Price
AnyHardwired
L6-20P
L6-30P
220, 230, or 240 volt
IEC309 16AS$60
Schuko 16AV$60
1
Limits output connections to two slots
2
UPS not TUV/CE listed.
1
2
2
A$0
K$60
L$60
All Prices F.O.B. Necedah, Wisconsin U.S.A. in U.S. dollars.
Product and pricing subject to change without notice.
3.1k - 2
QFER(S)3.1kVA CTO Configuration Guide
Output Connection
Output Connection Configuration is designated by 8 digits within the unit CTO number. These eight
digits allow selection of the type and quantity of the receptacles.
• Three output slots available with line cord input connection.
• Two output slots available with hardwire input connection.
• If multiple quantities of one type of receptacle is desired, enter the type once with the total quantity
(ex: D2 not D1D1).
• Always enter the receptacle types alphabetically (ex: D1E1 not E1D1).
• If hardwire output is desired, select type “A”, quantity “0” for all four receptacle types (ex:
A0A0A0A0).
• If fewer than four types of receptacle are selected, complete the remaining receptacle digits with A0
(ex: D1E1A0A0).
Output Voltage RequiredOutput Connection
AnyHardwired
1
CTO Order Code
TypeQty
A___$0
Option Price
per Panel
6-15R DuplexD___$75
6-20R DuplexE___$75
L6-15R DuplexJ___$75
L6-20RK___$75
L6-30RL___$75
220, 230, or 240 volt
United KingdomO___$70
AustralianP___$70
SchukoR___$70
French SchukoT$70
IEC320 10 AmpU___$50
Receptacle Output Connection CTO Order Code _ _ _ _ _ _ A 0
Hardwire Output Connection CTO Order Code A 0 A 0 A 0 A 0
1
Hardwired output requires hardwired input
Internal Options
OptionCTO Order CodeOption Price
No other optionA$0
DVR1 (recommended when loads contain PFC power supplies)B
Neutral to Ground bond removal (For shipboard use)Q$25
1
Cannot be used with short rackmount cabinet option or internal or less battery options.
1
$150
All Prices F.O.B. Necedah, Wisconsin U.S.A. in U.S. dollars.
Product and pricing subject to change without notice.
3.1k - 3
QFER(S)3.1kVA CTO Configuration Guide
External Options
External battery packs, bypass switches and other external options are not a part of the CTO number and
will need to be ordered as separate line items. Some external options require that the UPS be configured
for use with the option.