Powerware 9120 User Manual

Series 9 Power Protection
True Online Design
True online systems such as the Powerware 9120 are the only type of UPSs that completely isolate con­nected equipment from all 9 of the most common power problems:
Even when presented with the most severe of these power problems, the Powerware 9120 output remains within a remarkable ±2% of nominal voltage, meaning that your critical system always receives clean power. In addition, the Powerware 9120 transfers to battery with no break in power, making it the perfect UPS for equipment in environments plagued by poor power.
Power Failures
UPS On On Battery On Bypass Alarm
Starts Up/Shuts down the UPS
Scroll meters/ Select UPS settings
Scroll UPS settings/ Select UPS setting parameter
LCD
Power Sags
Power Surges
Undervoltage
Electrical Line Noise
Overvoltage
Frequency Variation
Switching Transient
Harmonic Distortion
Powerware 9120 Features
Front Panel Display
Informative user interface with LCD, four LED and audible alarms.
Loads Segments, Network Transient Protector and Remote Emergency Power Off (REPO) Port
Load Segments are groups of receptacles that can be independently controlled and extend battery backup times for critical equipment. To preserve battery power for more critical equipment connected to Load Segment 1, shut down Load Segment 2 supporting less critical equipment.
Shut down and power up Load Segments in user defined sequence.
The Network Transient Protector isolates your modem, fax machine, and other electronic equipment from “back door” power surges
The REPO port enables you to shut down the UPS and connected equipment from a remote location in an emergency.
1 2 3 4
1 2 3 4
Powerware 9120 1000 Shown
SOFTWARE SUITE
LanSafe III &
CheckUPS
Network Shutdown
for UPSs
LanSafe III &
CheckUPS
Network Shutdown
for UPSs
OnliNet
SNMP-Based
Network Shutdown
& Monitoring
OnliNet
SNMP-Based
Network Shutdown
& Monitoring
Foreseer
Facility & Data Center Management
Foreseer
Facility & Data Center Management
Foreseer
Facility & Data Center Management
LanSafe III &
CheckUPS
Network Shutdown
for UPSs
PowerVision
UPS Performance Analysis & Monitoring
PowerVision
UPS Performance Analysis & Monitoring
PowerVision
UPS Performance Analysis & Monitoring
OnliNet
SNMP-Based
Network Shutdown
& Monitoring
Hot-Swappable Batteries
You can hot-swap batteries without powering down the critical load. This makes it possible to extend the life of your UPS without returning the unit for service.
Extended Battery Modules (EBMs)
Increasing battery backup time is as simple as plugging in an extended battery module. Hot-swap capability on all Powerware 9120 models allow you to expand run time or replace battery modules while keeping your critical load up and running.
The lead-acid batteries typically used in a UPS are considered viable as long as they can maintain backup time of at least half that of new batteries. The illustration below shows that batteries that are constantly trickle charged (as are virtually all other UPS batteries on the market today) reach the end of their useful life in less than half the time of batteries charged using ABM. ABM uses a three-stage charging technique that not only doubles battery service life, but also optimizes battery recharge time and provides advanced notification of the end of useful battery life.
Advanced Battery Management (ABM) Technology Doubles Battery Service Life
Data based upon tests performed by an independent battery manufacturer
Battery Features and Run times
VA Standard Internal Battery 1 EBM 2 EBMs 3 EBMs 4 EBMs 5 EBMs
700 7/18 34/70 64/140 — 1000 7/18 36/80 66/155 — 1500 7/18 29/67 56/130 — 2000 12/34 49/107 93/195 140/310 192/403 240/504 3000 6/15 30/70 57/128 87/191 120/264 148/325
*Up to 2 EBMs can be connected to 700/1000/1500VA models and up to 5 EBMs can be connected to 2000/3000VA models. Run time chart provides typical information. Run times are approximate and may vary with equipment, configuration, battery age, temperature, etc.
Battery Run Time Chart (in minutes full load/half load)*
Powerware 9120 - 1000VA shown with front cover removed and battery shown sliding out.
SOFTWARE SUITE
LanSafe III &
CheckUPS
Network Shutdown
for UPSs
LanSafe III &
CheckUPS
Network Shutdown
for UPSs
OnliNet
SNMP-Based
Network Shutdown
& Monitoring
OnliNet
SNMP-Based
Network Shutdown
& Monitoring
Foreseer
Facility & Data Center Management
Foreseer
Facility & Data Center Management
Foreseer
Facility & Data Center Management
LanSafe III &
CheckUPS
Network Shutdown
for UPSs
PowerVision
UPS Performance Analysis & Monitoring
PowerVision
UPS Performance Analysis & Monitoring
PowerVision
UPS Performance Analysis & Monitoring
OnliNet
SNMP-Based
Network Shutdown
& Monitoring
Loading...
+ 3 hidden pages