Powerware’s full line of power
protection products. The Powerware 3115
is the ideal UPS for PCs, workstations,
point-of-sale (POS) systems, cash registers,
network nodes, and similar equipment
requiring basic cost-effective protection.
Because an integral part of power protection
is power management software, the
Powerware 3115 comes fully equipped with
a communications port, serial cable, and a
CD containing both FailSafe III for standalone systems and LanSafe III for networked
systems to ensure data integrity during
extended power failures.
Designed with a small footprint, the
Powerware 3115 is easy to install and
operate. Audible alarms inform you of any
fault conditions, and when the replace
battery alarm sounds, there’s no need to
return the unit to the factory for service.
Instead, you can save money by simply
replacing the batteries without having to
purchase a new UPS.
Backed by Powerware’s exclusive Triple
Power Warranty and bearing full agency
approvals, the Powerware 3115 incorporates the highest level of service, design,
and performance. The Powerware 3115 is
power protection you can count on to keep
you up and running—without interruption!
F e a t u r e s
Uninterruptible power protection
against power failures, power sags,
and power surges
Power management software
provides monitoring and shutdown
capabilities for the vast majority of
operating systems
Easy to install
User-replaceable batteries extend the
service life of the UPS
Comprehensive agency approvals
When the audible alarm indicates that the batteries need
to be replaced, you can safely install supplied batteries
and return the old batteries for proper disposal and
recycling. You also have the option of returning the entire
unit for repair or battery replacement under Powerware's
Triple Power Warranty.
Audible Alarms
In addition to the user-friendly front
panel, the Series 3115 is fully equipped
with a set of audible alarms that alert
you to vital overload, fault, and battery
conditions.
Power Management
Software
The Series 3115 comes complete with
LanSafe III/FailSafe III for power
monitoring and shutdown capabilities.
Power loss and low battery warnings
Automatic orderly shutdown of all
intelligent network devices
Power Event Log saves data on
power disturbances
Notification via e-mail, paging, and
broadcast alerts in the event of a
power failure
Security with user-defined Access
Codes
O P E R A TING SYSTEMS
FailSafe III for standalone PCs is
available for:
OS/2, Windows 3.x, Windows NT,
and Windows 95/98
LanSafe III for networked computing
environments is available for:
Novell NetWare, DOS, Windows NT,
Windows 95/98, OS/2, UNIX
and Macintosh
Rear Panel Display
(Model PW3115 300/PW3115 420)
Communication Port
Provides interface for
LanSafe III/FailSafe III
software
communications
Resettable Circuit
Breaker
Reset circuit breaker
with the push of
a button
Input Cord
(120 Vac models)
Plug the UPS into the
wall socket and it’s
ready to go
DIP Switches
Specify wider input
voltage range that UPS
accepts before transferring to battery power
Site Wiring
Fault Indicator
(120 Vac models)
Illuminates if there is
a wiring problem in the
wall socket
Output Receptacles
Connect your
equipment easily
90˚ Angle Plug
(120 Vac models)
The input plug on
120 Vac models fits
flush against the wall
to save space.
Specifications
In a perfect world, your electrical
equipment would always receive clean
power. However, without UPS protection,
power quality can be erratic, causing serious
damage to your files and hardware.
Acting as a defensive barrier between your
equipment and dirty power, the Powerware
3115 eliminates the threats caused by
power failures, power surges, and power
sags, thus increasing productivity and your
bottom line.
Series 3 Power Protection
The Powerware 3115 is a Series 3 UPS,
meaning it protects your equipment from
three basic power problems: power failures,
power surges, and power sags.
Power Failures
A complete loss of utility power that can be
caused by events such as lightning strikes,
grid over-demands, accidents, and natural
disasters.
These three power problems can cause
hardware damage, keyboard lockups,
data corruption, and data loss.
IN P U T
Power Levels300, 420, and 650 VA; see Model Selection Guide
TopologyStandby
Operating Voltage 120 Vac models: 103 to 142 (default);
Range88 to 142 Vac (user-selectable)
230 Vac models: 196 to 260 (default);
166 to 260 Vac (user-selectable)
Frequency50/60 Hz
Frequency Range57 to 63 Hz @ 60 Hz
47 to 53 Hz @ 50 Hz
Current3.5A @ 120 Vac; 1.8A @ 230 Vac
ConnectionsSee Model Selection Guide
ProtectionResettable circuit breaker
Total HarmonicSame as input
Distortion (THD)
TVSS RatingTotal energy rating more than 240J, 6500A
Surge voltage let-through (percentage of applied ANSI
C62.41 Cat. A +6kV test waveform) ≤ 5%
AC OU T P U T, NO R M A L MO D E
Voltage120 and 230 Vac; see Model Selection Guide
Frequency50/60 Hz auto-selectable; same as input
FrequencySame as load
Regulation
Overload110% + 10% overload for 3 minutes. SMPS load, pure sine
wave input. 120% + 10% for 10 cycles
Efficiency96% straight through mode @ full load and fully charged
battery
AC OU T P U T, BAT T E RY MO D E
Voltage RegulationNominal voltage ±5%; -10% at low battery
WaveformStep wave (synthesized sine)
Frequency50/60 Hz ±1 Hz of auto-selected nominal frequency
Regulation
Transfer Time4 milliseconds, typical
Efficiency>70%, 100% SMPS load
Power Surges
With voltages above 110% of nominal,
surges can be triggered by rapid reduction
in power loads, heavy equipment being
turned off, or by utility switching.
Power Sags
The opposite of surges, sags are caused by a
startup of large loads, utility switching,
utility equipment failure, lightning, and
power service that is too small for the
demand.
BAT T E RY
Backup TimeSee Battery Run Times table
Battery Recharge12 hours to 95% usable capacity @ nominal line after full
Timeload discharge
Start-On-BatteryStartup with UPS batteries in absence of utility power
Battery12 and 6 Vdc batteries; Valve-Regulated Lead Acid (VRLA),
minimum 3 year float service life at 25°C
Battery ProtectionInternal batteries protected by either a fuse or circuit
breaker. Fuse ratings: 30A/32 Vdc and 40A/32 Vdc
Charger Voltage13.5 to 13.8 Vdc
Maximum Charge12V battery = 0.7 ± 0.1A
ImmunityIEC 61000-4-2, -3, -4
Audible Noise< 40 dBA
Operating Altitude3000m (10,000 ft max.)
Operating0°C to 40°C, 0 to 1500 meters above sea level
Temperature0°C to 35°C, 1500 to 3000 meters above sea level
Transit and -15°C to +55°C
Storage Temperature
Relative Humidity0 to 95% noncondensing
ME C H A N I C A L
DimensionsSee Model Selection Guide
and Weight
Powerware 3115Model Selection Guide
MO D E LPO W E R OU TIN P U TOU T P U TDI M E N S I O N SWE I G H T
NU M B E R( VA / WAT T S)CO N N E C T I O NCO N N E C T I O N S(H X W X D; C M/I N C H E S)(K G/L B)
120V1; 50/60 Hz Models for North America, Central America, & parts of South America
1. 120V default; 110V and 127V user-selectable. 2. 6’ line cord. 3. 230V default; 220V and 240V user-selectable. 4. Ships with (2) IEC interconnecting cords.
BAT T E RY RU N TI M E S ( IN M I N U T E S)
AP P L I C AT I O NLO A D ( CO N N E C T E D EQ U I P M E N T)PW3115 300(i)PW3115 420(i) PW3115 650(i)
Electronic cash register75 VA/45 Watts303541
Stackable hub150 VA/90 Watts242532
Router200 VA/120 Watts161727
Intelligent terminal or POS300 VA/180 Watts101118
Pentium PC or Power Mac w/15" monitor350 VA/210 Watts716
Moderately configured Pentium PC or Power Mac w/15" monitor420 VA/252 Watts612
Moderately configured Pentium PC or Power Mac w/17" monitor500 VA/300 Watts9
Heavily configured Pentium PC or Power Mac w/19" monitor600 VA/360 Watts7
Heavily configured Pentium PC or Power Mac w/21" monitor650 VA/390 Watts6.5
Backup times are approximate and may vary considerably due to modified configurations, environmental conditions, ambient temperature, battery age, and other factors.
2
2
2
(2) 5-15R15.5 x 8.6 x 32.3/6.1 x 3.4 x 12.85.2 /11.5
(2) 5-15R15.5 x 8.6 x 32.3/6.1 x 3.4 x 12.85.2/ 11.5
(4) 5-15R16.3 x 11.7 x 35.6/6.4 x 4.6 14.07.5/16.5
4
4
4
15.5 x 8.6 x 32.3/6.1 x 3.4 x 12.85.2 /11.5
15.5 x 8.6 x 32.3/6.1 x 3.4 x 12.85.2 /11.5
16.3 x 11.7 x 35.6/6.4 x 4.6 14.07.5/16.5
120 Vac Rear Panels
PW3115 300 / PW3115 420PW3115 650
230 Vac Rear Panels
PW3115 300i / PW3115 420iPW3115 650i
Powerware Corporation
Corporate Headquarters
8609 Six Forks Road
Raleigh, NC 27615 U.S.A.
Toll Free: 1.877.797.9273
or 919.872.3020
Fax: 1.800.753.9433
or 919.870.3411
E-mail: info@powerware.com
www.powerware.com
Reprint 3115FXA 9/99
Revision 9/99
Latin America/Caribbean
Sunrise, FL: 954.835.1180
Europe/Middle East/Africa
Berkshire, England: 44.1753.606700
Southeast Asia
Singapore: 65.861.9877
China and North Asia
Hong Kong: 852.2745.6682
Australia and South Pacific
Sydney, Australia: 61.2.9878.5000
Canada
Toronto, Ontario: 416.798.0112
Windows is a registered trademark of Microsoft Corporation. OS/2 is a
registered trademark of International Business Machines Corporation.
Novell and NetWare are registered trademarks of Novell, Inc. Other
brand or product names are trademarks or registered trademarks of
their respective holders. Due to continuing product improvement programs, specifications are subject to change without notice.
Loading...