Powersolve PPS120P User Manual

AC-DC Converters
www.powersolve.co.uk
PPS120P Series
90/120 Watts
Single, Dual, Triple & Quad Outputs
Features
IEC EN61000-3-2 (D) compliance
Universal input
Built-in EMI filter
UL/cUL, TUV safety approved
Optional cover
Electrical Specification
INPUT
Input range 90~264 VAC, universal Frequency 47~63Hz Inrush current 38A typical, Cold start @ 25°C, 115 VAC Efficiency 65%~85% typical at full load EMI filter FCC part 15 Class B, CISPR 22/EN55022 Class B Power factor >0.97@115 VAC
>0.95@230 VAC Typ.
OUTPUT
Max. power 90W convection, 120W with 30CFM forced air Line Regulation ±0.5% Load Regulation Cross Regulation Main Output +5%, Aux. Outputs +10% Typ. Hold-up Time 16mS Typ. at full load, 115 VAC Noise & Ripple Over Voltage Protection latch-off Overload Pr Short Circuit Protection auto-recovery Output adjust output 1 ±10%
ENVIRONMENTAL
Operating temperatur Storage temperature -40°C to 85°C Electromagnetic susceptibility meet IEC 801-2,-3,-4,-5 Level 3 Humidity Vibration 10 to 55Hz at 1G, 3 minutes period, 30 minutes along X,Y and Z axis
emperatur
T MTBF demonstration >100,000 hours at 25°C Safety approvals UL1950/cUL, TUV EN60950
otection
e
e coefficient +0.05% per degree C
Main Output +3%, Aux. Outputs +5% T
yp.
1% T
ecovery
auto-r
°C ambient, derate each output at 2.5% per degree from 50°C to 70°C
C to 50
°
0
Operating, non-condensing 5% to 95%
yp.
Powersolve Electronics Ltd. Units 8A, Arnhem Road, Newbury, RG14 5RU. England
Tel:01635 521858 Fax: 01635 523771 Email: sales@powersolve.co.uk
AC-DC Converters
www.powersolve.co.uk
MODEL OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 TOTAL REGULATION
PPS120P-10 5V 24A ±3%
PPS120P-11 12V 10A ±3%
PPS120P-12 15V 8A ±3%
PPS120P-13 24V 5A ±3%
PPS120P-14
PPS120P-16 56V 2.2A ±3%
PPS120P-18 3.3V 24A ±5%
PPS120P-20* +5V 12A +12V 5A ±5% both outputs
PPS120P-21*
PPS120P-22* +5V 12A +48V 1.25A ±5% both outputs
PPS120P-23* +12V 6A +48V 1A ±5% both outputs
PPS120P-24*
PPS120P-25* +3.3V 12A +12V 7A ±5% both outputs
PPS120P-30* +5V 12A +12V 4.5A -5V 0.6A O/P 1&2 ±5%, O/P 3 ±10%
PPS120P-31* +5V 12A +12V 4.5A -12V 0.6A O/P 1&2 ±5%, O/P 3 ±10%
PPS120P-32* +5V 12A +15V 3.5A -15V 0.6A O/P 1&2 ±5%, O/P 3 ±10%
PPS120P-32A* +5V 12A +15V 2A -15V 2A O/P 1&2 ±5%, O/P 3 ±10%
PPS120P-33* +5V 12A +15V 4A -5V 0.5A O/P 1&2 ±5%, O/P 3 ±10%
PPS120P-34* +5V 12A +15V 3.5A -12V 0.7A O/P 1&2 ±5%, O/P 3 ±10%
PPS120P-35* +5V 11A +24V 2.5A -12V 0.6A O/P 1&2 ±5%, O/P 3 ±10%
PPS120P-36* +5V 11A +12V 5A -12V 1A O/P 1&2 ±5%, O/P 3 ±10%
PPS120P-37* +12V 6.5A +1.8V 6A -12V 2A O/P 1&2 ±5%, O/P 3 ±10%
PPS120P-40* +5V 12A +12V 4.5A -12V 0.5A -5V 0.5A O/P 1&2 ±5%, O/P 3&4 ±10%
PPS120P-41*
PPS120P-42* +5V 12A +12V 3A -15V 1A +15V 1A O/P 1&2 ±5%, O/P 3&4 ±10%
PPS120P-42A
PPS120P-43* +5V 8A +12V 3.5A -12V 1A -15V 2A O/P 1&2 ±5%, O/P 3&4 ±10%
PPS120P-44* +5V 8A +12V 2A -12V 1A +48V 1A O/P 1&2 ±5%, O/P 3&4 ±10%
PPS120P-45* +5V 8A +12V 2A -12V 1A +24V 2A O/P 1&2 ±5%, O/P 3&4 ±10%
PPS120P-46* +5V 9.6A +12V 1A -12V 2A +36V 1A O/P 1&2 ±5%, O/P 3&4 ±10%
48V 2.5A ±3%
+5V 12A +24V 2.5A ±5% both outputs
+12V 4A +56V 1.3A ±5% both outputs
+5V 12A +12V 4A -5V 1A -12V 1A O/P 1&2 ±5%, O/P 3&4 ±10%
+5V 10A +15V 3A -15V 1A +12V 1A O/P 1&2 ±5%, O/P 3&4 ±10%
Note:
CONVECTION COOLING: PEAK CURRENT
RIPPLE & NOISE:
LOAD REGULA
: Peak output currents of 125%, lasting <30 seconds with a maximum of 10% duty cycle can be taken,
TION: Load test conditions are from minimum, 50% and 100% load conditions on each output.
Powersolve Electronics Ltd. Units 8A, Arnhem Road, Newbury, RG14 5RU. England
Maximun output power 90 Watts with convection cooling, derate outputs by 25% under these conditions.
subject to maximum 150 W Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth, input at nominal line voltage,
0.1uF and 47uF capacitor on outputs.
*Minimum loading of 10% r
atts peak load.
equired on all outputs, to achieve regulation specified.
Tel:01635 521858 Fax: 01635 523771 Email: sales@powersolve.co.uk
www.powersolve.co.uk
Powersolve Electronics Ltd. Units 8A, Arnhem Road, Newbury, RG14 5RU. England
Tel:01635 521858 Fax: 01635 523771 Email: sales@powersolve.co.uk
Loading...