Powersolve PAK350 User Manual

AC-DC Converter
PAK350 Series
www.powersolve.co.uk
350W Active PFC Single Output
Features
Universal AC Input with active PFC
High Efficiency up to 93%
+5V/0.3A Auxiliary Output
150% Peak Load Capability
1U profile, High Power Density
Built-in Constant Current Limiting Circuit
Power OK signal (Power good, logic low)
Remote ON/OFF, Remote Sense function
OVP, OLP, OTP, SCP, Fan Failure Protections
Electrical Specification
Input Voltage 90-264VAC full range, 47-63Hz / 127-370VDC Power Factor 0.98 at 230VAC / 0.99 at 115VAC at full load AC Input Current (typ.) 4A at 115VAC / 2A at 230VAC Inrush Current 27A at 115VAC / 54A at 230VAC Leakage Current <1mA at 230VAC Output Voltage See Table Output Current See Table Voltage Adjust Range ±10% typical adjustment by potentiometer Voltage Tolerance ±1% Set Up, Rise Time 800ms, 60ms at full load Hold Up Time (typ.) 16ms at 230VAC, full load Overload Protection >105-150% of rated output power for more than 3 seconds, shutdown output with auto recovery
Overvoltage Protection See Table for values. Output latches off, recycle AC input to recover Over Temperature Protection Shuts down output, recovers automatically when temperature goes down Auxiliary Power +5V/0.3A (±3%) Remote ON/OFF Control External switch or NPN transistor to turn on/off Power OK Signal Open drain signal low when PSU turns on. Max. sink current 20mA, max drain voltage 40V Operating Temp. Range -25°C to +70°C. Above 50°C, derate linearly to 50% load at 70°C Operating Humidity 20-90% RH non-condensing Storage Temp. Range -40°C to +85°C Storage Humidity 10-95% RH non-condensing Temperature Coefficient ±0.02%/°C (0-50°C) Vibration Compliance to IEC 68-2-6, IEC 68-2-64 Safety Standards UL60950-1 2nd edition, TUV EN60950-1: 2006+A11 approved Withstand Voltage I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC Isolation Resistance I/P-O/P, I/P-FG, O/P-FG: 100MΩ / 500VDC EMI Conduction & Radiation EN55022: 1998+A1 : 2000+A2 : 2003 Class B Harmonic Current EN61000-3-2: 2000+A2 : 2005 Class A, EN61000-3-3 : 1995+A1 : 2001 EMS Immunity EN61000-4-2, 3, 4, 5, 6, 8, 11 Cooling Internal fan Dimensions 199(L) x 105(W) x 41(H) mm Weight 1.05Kg
>150% of rated output power or short circuit then constant current limiting. If output drops to 40% of rated output voltage then shutdown and auto recover for 5 times attempts. If fault remains for more than 5 attempts then latch off output and re-power on to recover.
Notes:
1. All parameters NOT specifically mentioned are measured at 230VAC input, rated load and 25°C ambient temperature
2. Ripple and noise are measured at 20MHz bandwidth by using a 12” twisted pair wire terminated with a 0.1µF ceramic & 47µF electrolytic capacitors across the output
3. Derating is required at low input voltages. Below 100VAC, derate linearly to 80% load at 90VAC
4. Tolerance: includes set up tolerance, line regulation and load regulation
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC Directives
Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England
Tel: 01635 521858 Fax: 01635 523771 Email: sales@powersolve.co.uk
AC-DC Converter
www.powersolve.co.uk
Output Voltage and Current Ratings
MODEL OUTPUT MAX OUTPUT OVERVOLTAGE RIPPLE & LINE LOAD POWER EFF.
PAK350-05 5V 60A 6.0-6.5V 150mV p-p ±0.5% ±0.5% 300W 83% PAK350-12 12V 30A 14.4-15.6V 150mV p-p ±0.5% ±0.5% 360W 90% PAK350-15 15V 24A 18.0-19.5V 150mV p-p ±0.5% ±0.5% 360W 90% PAK350-24 24V 15A 28.8-31.2V 150mV p-p ±0.5% ±0.5% 360W 91% PAK350-48 48V 7.5A 57.6-62.4V 150mV p-p ±0.5% ±0.5% 360W 93%
Mechanical & Connection Details
VOLTAGE CURRENT PROTECTION NOISE REG. REG. Max.
Connections
Pin Function 1 Live 2 Neutral 3 Earth 4 -V out 5 -V out 6 +V out 7 +V out
Function Description of CN2, Control Connector
Pin No. Function Description Mating Housing Terminal
1 AUX +5V / 0.3A Auxiliary Power 2 GND Ground 3 POK Power OK 4 EN- Remote ON/OFF (-) 5 GND Ground 6 EN+ Remote ON/OFF (+) 7 VS+ Remote Voltage Sense (+) 8 VS- Remote Voltage Sense (-)
Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England
Tel: 01635 521858 Fax: 01635 523771 Email: sales@powersolve.co.uk
JST
PHDR-08VS
JST
SPHD-002T-P05
AC-DC Converter
Derating Curves
Peak Loading
www.powersolve.co.uk
Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England
Tel: 01635 521858 Fax: 01635 523771 Email: sales@powersolve.co.uk
AC-DC Converter
www.powersolve.co.uk
Functions
Remote ON/OFF
(A) (B) (C)
(A) Using internal 5V auxiliary source (B) ON/OFF control by NPN transistor (C) Using external voltage source
OFF Power ON
SW
ON Power OFF
Remote Sense
Power OK Signal & Auxiliary Output
L Power ON
Tr
H Power OFF
OFF Power ON
SW
ON Power OFF
Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England
Tel: 01635 521858 Fax: 01635 523771 Email: sales@powersolve.co.uk