Powers Hydroguard 410 5, Hydroguard 410 8, Hydroguard 410 Series Technical Instructions

DESCRIPTION
The Series 410 Hydroguard is a pressure compensating mixer which delivers a predetermined water temperature, compen­sating for pressure fluctuations in the hot or cold water supply.
The Series 410 Hydroguard features a poppet-type equaliz­ing valve as part of a replaceable cartridge. The poppet-type construction offers a distinct advantage, it will not stick because of lime build-up or foreign particles in the supply. The adjustable maximum temperature stop prevents acci­dental scalding caused by overadjustment of the handle.
Many Series 410 valves and shower systems can be select­ed to meet the Americans with Disabilities Act (ADA) [see back page for details].
SPECIFICATIONS
Operating
Capacity: Shower and Tub
6 gpm at 45 psi differential [22.7 L/min at 310 kPa]
Maximum Static Pressure
...................125 psi [862 kPa]
Maximum Inlet Temperature
.....................180°F [82°C]
Inlet and Outlet Sizes
................................1/2NPT
Roughing-in Template
..............................All Models
Maximum Temperature Adjustment
................All Models
Complies to ASSE 1016 & CSA B125.....................All Models
APPLICATION
The Series 410 Hydroguard is particularly recommended in showers and shower bath installations for motels, hotels, dormitories, and high rise apartment buildings.
OPERATION (SEE FIGURE 1)
Hot and cold water enter their respective ports and the pres­sures are equalized through the action of the balance poppet (1). The entire balancing poppet assembly is contained in a Celcon chamber (2). This chamber is replaceable as a com­plete cartridge. After the hot and cold pressures are equal­ized, they are mixed by the action of a mixing plate (3). As the temperature adjustment stem is rotated from shutoff to maximum hot water temperature, the mixing plate passes the required proportion of hot and cold water to produce the control point. With the adjustment stem in its full clockwise position, shutoff is obtained by closing both supplies.
The maximum temperature stop (4) allows the user to set the maximum discharge temperature. This mixer does not recog­nize supply water temperature changes, so any variation in the water temperature will affect the control point and
the
maximum temperature setting.
NOTE: Following any maintenance of unit, maximum temperature stop must be reset. See page 5 for instruc­tions.
TECHNICAL INSTRUCTIONS
Hydroguard Series 410 Valves
Model 5 and Model 8
Form TI410-5 v3
2
Celcon Chamber
4
Maximum
Temperature
Stop
Bonnet
Hot Water Supply
1
Balancing
Poppet
Assembly
Cold Water Supply
3
Mixing Plate
Stem
FIGURE 1 – OPERATION
411/416
MAINTENANCE
Troubleshooting
What to look for:
1. The flow of water is less than desired.
a. Valves upstream from supply not fully open. b. Low supply pressures. c. Accumulation of lime deposits in hot water pipes,
restricting the flow of hot water. d. Showerhead clogged. e. Checkstops may not be fully open. f. Low supply temperature (Hot Water).
2. Flow of water is completely shut off.
a. Valves upstream from supply completely closed. b. Failure of hot or cold water supply pressure. The
Hydroguard is constructed to restrict the flow of water
on hot or cold water supply failure. c. Checkstops closed.
3. Flow is untempered hot or cold water.
a. The water supplies are connected to the wrong ports. b. Diaphragm is ruptured; replace with new cartridge. c. Check for foreign material that may be clogging the
cartridge.
4. Flow of water continues when Hydroguard is shut off.
a. Worn shut-off discs. Replace worn disc. b. Scratched mixing plate. c. Erosion. Contact a Powers applications engineer to
order replacement parts.
5. Maximum temperature is too low.
a. Accumulation of lime deposits in hot water pipes,
which restricts the flow of hot water. b. The concealed maximum temperature limit stop is not
at its maximum adjustment. See page 5 to set the
maximum temperature limit stop. c. Hot water temperature is too low.
6. Standard inlets are desired.
See Figure 2 for instructions on standard inlets (with cold water entering the COLD port). With mixer in closed posi­tion, the notch
in the top spline on the stem must FACE
the outlet.
7. Reversed inlets are desired.
See Figure 3 for instructions on reversing the mixing plate (with cold water entering HOT port). For reversed inlets, the notch
must face AWAY FROM the outlet port.
Note: When using reversed inlets, the HOT and COLD inlets should be identified to avoid confusion during future maintenance.
TI410-5 v3 Page 2
HOT
COLD
COLD
Outlet
Orientation of Plate and Stem Assembly
for STANDARD Inlets
(Cold Water into Cold port)
Must Point
to COLD Inlet
Notch in Handle
Spline
Must FACE TOP
Water
HOT
Water
C
FIGURE 2 – STANDARD INLETS
HOT
COLD
HOT
Outlet
Orientation of Plate and Stem Assembly
for REVERSED Inlets
(Cold Water into Hot port)
Must Point
to HOT Inlet
Notch in Handle
(Top) Spline
Must Face AWAY
From Outlet
Water
COLD
Water
C
FIGURE 3 – REVERSED INLETS
TI410-5 v3 Page 3
F
RONT
FI
NISH
E
D
W
A
L
L
G
U
I
DE
TRI-HANDLE ASSEMBLY
(All Models: 1-8)
5c
5b
5a
LEVER HANDLE ASSEMBLY
(Model 8)
ACRYLIC HANDLE ASSEMBLY
(Model 8)
2b
2a
HOT
POWERS
5
COLD
U7
Model
Number
Date
Code
5U7
Model
4
0
1
-
0
0
0
P
a
r
t
N
o
.
See Nameplate to determine your valve model:
11
9
10a
10b
27
26
25
28
23
22
25
25A
28
24
21
21A
20
13
19
18
18A
17
15
13
12
14
16
ABOVE: Parts 11-28 in Valve body BELOW: Parts 11-28 Detailed
10
4e
4b
4a
4d
4c
Used on 4-port mixers only. No discharge will occur when used in a 3-port mixer.
R
H
C
6
7
8
PAR TS
KIT KIT NUMBER KIT KIT NUMBER
Lever Handle Assembly Kit (Model 8) 410-448
Items 2a-2b (Qty: 1 each), 6
Acrylic Handle Assembly Kit (Model 8) 410-447
Items 4a-4e (Qty: 1 each), 6
Tri-Handle Assembly Kit 410-565
Items 5a-5d (Qty: 1 each)
Dial Assembly Kit, Standard 410-445
Items 7, 9, 10a, 10, 8
Dial Plates (bulk pack) 410-413BP
Item 10 (Qty: 15)
Dial Plates (jumbo bulk pack) 410-413JP
Item 10 (Qty: 25)
Retainers (bulk pack) 410-367
Item 7 (Qty: 10)
Balancing Cartridge Kit (3-port) 410-183
Items 18, 22, 23, 24†, 25, 26
Balancing Cartridge Kit (4-port) 401-175
Items 18, 22, 23, 24†, 25, 26
Flat Washers (bulk pack) 410-368
Item 20 (Qty: 15)
Wavy Washers (bulk pack) 410-369
Item 19 (Qty: 10)
Gasket and Disk Replacement Kit 410-182
Items 13, 18, 18a, 22, 23, 24†, 25
O-Rings (bulk pack) 410-366
Item 13 (Qty: 25)
Oversize 410 Inlet Seal Kit 410-570
10a, 13, 22, 23, 24, 25, 25A
Screws, for dial plate (bulk pack) 420-216
Item 9 (Qty: 20)
Throttling Stem/Plate Replacement Kit 410-378
Items 13, 18, 18a, 19, 20, 21, 22
† For use on 4-port mixers only. No discharge will occur when used in 3-port mixers.
* Sleeve (401-253) used on 419’s only (not shown).
TI410-5 v3 Page 4
PARTS – SERIES 410 HYDROGUARD
Series 410 Hydroguard Pressure equalizing mixer. Poppet-type construction. Adjustable maximum temperature stop.
Item Part Description Part No. Quantity Material
2a-2b Lever Handle Assembly (410 Model 8) see kit #410-448 2a Lever Handle Screw (8-32 x 1-1/4") * 1 C.P. Brass 2b Lever Handle * 1 C.P. Zinc 4a-4e Acrylic Handle Assembly (410 Model 8) see kit # 410-447 4a Plug Button and Insert 420-314 1 C.P. Brass 4b Acrylic Handle Screw (8-32 x 3/4") 034-515K 1 C.P. Brass 4c Washer 227-197 1 Neoprene 4d Control Knob/Sleeve Assembly 420-310 1 Acrylic and Brass 4e Acrylic Handle Insert 420-125 1 C.P. Zinc 5a-5d Tri-Handle Assembly (All 410 Models: 1-8) see kit # 410-565 5a Tri-Handle Screw 030-070 1 C.P. Zinc 5b Washer 046-008K 1 C.R. Steel 5c Tri-Handle 410-191 1 C.P. Brass 5d Plug Button (not shown) 410-195 1 -­6 Sleeve 401-267 1 C.P. Copper 7 Retainer for Brass Stamped Standard Dial see kit # 410-367 7a Retainer for Brass Stamped Deluxe Dial 410-417 1 Rubber 8 Dial Insert (Model 5) (not shown) 410-374 1 Aluminum
Graphic Insert (not shown) 410-442 1 9 Screws (2) see kit # 420-216 10 Dial Plate see kit # 410-445 10a Gasket see kit # 410-570 10b Rough-in Guide (All Models) 401-178 1 ­11 Bonnet Screws (10-32 x 1") (4) 030-885 4 Stainless Steel 12 Adjustment Stop Screw (10-32 x 5/16") 030-884 1 Stainless Steel 13 O-Rings (3/8" x 1/2" x 1/16") (2) see kit # 410-182/410-570/410-378 1 14 Maximum Temperature Stop 401-218 1 Brass 15 Adjustment Stop 401-278 1 Stainless Steel 16 Support Ring 410-377 1 Stainless Steel 17 Bonnet 401-162 1 Noryl 17a Bonnet for 414 Valve (not shown) 410-393 1 Noryl 18 Bonnet Gasket (Rainbow Style) see kit # 410-182/410-378 18a Bonnet O-Ring (Models 1-3 only) (not shown) see kit # 410-182/410-378 19 Wavy Washer see kit # 410-378/410-369 20 Flat Washers (4) see kit # 410-368/410-378 21 Throttling Stem see kit #410-378 21a Throttling Stem for 419 Valve (not shown) 410-378A 1 Brass Stem Celcon Plate 22 Shut-off Discs (2) see kit # 410-570/378, 182, 183, 401-175 23 Quad Rings (2) see kit # 410-570, 182, 183, 401-175 24† O-Ring (1-3/4" x 1-7/8" x 1/16")† see kit # 410-570, 182, 183, 401-175 25 O-Rings (1-3/4" x 1-3/16" x 3/32") (2) see kit # 410-570, 182, 183, 401-175 25A O-Ring (oversized) see kit # 410-570 26 Balance Chamber (3-port valves) see kit # 410-183
Balance Chamber (4-port valves) see kit # 401-175 27 Body, 4-Port N/A
Body, 3-Port (not shown) N/A
† For use on 4-port mixers only. No discharge will occur when used in 3-port mixers.
TI410-5 v3 Page 5
SERVICING
1. Shut off upstream water supply.
2. Remove the dial assembly and handle. See page 3 for rela­tionship of parts. Unscrew four cap screws and remove cap assembly by gently pulling on stem.
3. TO REMOVE THE BALANCE CHAMBER, using a balance chamber extraction tool (Part No. 401-202) is highly recom­mended. To use the extraction tool, follow instructions below:
a. Insert hooked ends of extraction tool into HOT and
COLD outlet ports of the balance chamber (see Figure
4).
b. Insert screwdriver down through end of extraction tool. c. Place a wood or plastic block (do not use metal)
between screwdriver and valve body. Firmly ease screwdriver away and downward, using wood for added leverage as cartridge is gradually pulled out.
4. Replace necessary items and reassemble. A small amount of silicone gel on the cartridge, O-rings, and related sur­faces will aid in the assembly.
CAUTION: Do not pinch cartridge O-rings during assembly.
5. Replace bonnet with new bonnet gasket. Proceed to step 6 to reset maximum temperature setting.
MAXIMUM TEMPERATURE SETTING
6. MAXIMUM TEMPERATURE SETTING (refer to Figure 5). This must be set on the job and following any maintenance or servicing to the valve. Mixer is factory set to pass full HOT water.
a. Loosen adjustment stop screw (do not remove).
Gradually rotate stem counterclockwise to get desired maximum water temperature. (Maximum Temperature Stop will rotate along with the stem when the stem is rotated.)
b. Once stem has been rotated to desired temperature,
slide adjustment stop clockwise until fin on adjustment stop touches the maximum temperature stop.
c. While holding adjustment stop in place, tighten adjust-
ment stop screw.
d. Replace handle. Confirm maximum temperature has
been set properly by operating the valve using the handle.
CAUTION: Adjustment stop must be present for proper operation.
FIGURE 5 – MAXIMUM TEMPERATURE SETTING
FIGURE 4 – BALANCE CHAMBER REMOVAL
Adj. Stop Screw
Adjustment Stop
Fin
Adjustment Stem
Maximum
Temperature
Stop
Balance
Chamber
Extraction
Tool
TI410-5 v3 Page 6
1. Cartridge slips while seated in body.
2. Flow of water continues after mixer is turned off, and all other seals have been replaced.
410-570 Items 13, 22, 23, 24, 25, 25A (also includes oversize O-ring for use with Models 1-8)**
1. To convert to Model 8 lever or acrylic handle. 410-445 Items 7,9,10a, 10, 8
410-448 Items 2a-2b, 6 410-447 Items 4a-4e, 6
1. Water leaks at stem and/or bonnet.
2. Flow of water continues after mixer is turned off.
410-182 Items 13, 18, 18a 22, 23, 24,* 25 (includes bonnet O-ring for Models 1-3)
1. Variable or untempered discharge temperature.
401-175 Items 18, 22, 23, 24*, 25, 26, 28
410-183 Items 18, 22, 23, 24*, 25, 26, 28
1. Flow continues after mixer is turned off.
2. Handle splines on stem damaged.
410-378 Items 13, 18, 18a 19, 20, 21, 22 (includes bonnet O-ring for Models 1-3)
Oversize 410 Inlet Seal Kit**
Dial Assembly Kit Lever Handle Kit Acrylic Handle Kit
Gasket and Disc Replacement
Balance Chamber (3-port)
Balance Chamber (4-port)
Throttling Stem and Plate Replacement
Recommended Repair KitDescription
Kit Number and Contents
*
Use item 24 only in 4-port model.
No discharge will occur if item 24 is used in 3-port model.
** When using oversize O-ring, discard ONE of the two regular sized O-rings normally used and use oversize O-ring in its place.
4-port valve models are: P416 and P417. 3-port valve models are: P411, P412, P413, P414 and P419.
Notes:
1. Use silicone provided on all O-rings and related surfaces. Never use grease.
2. Some kits contain parts for all models; discard extra parts as appropriate.
TROUBLESHOOTING
HOT
COLD
OFF
38" (typical) [96.5 cm]
48" (typical) [121.9 cm]
ADA-COMPLIANT OPTIONS
When used together, Powers lever handle and handshower meet ADA compliance standards. For complete ADA­required heights and other information on installing an ADA­compliant bathing system, refer to the ADAAG (Americans with Disabilities Act Accessibility Guidelines).
TI410-5 V2 Page 7
NOTES
TI410-5 V2 Page 8
Form TI410-5 v3 0310 6511202 PRINTED IN U.S.A.
USA office: Phone: 800.669.5430 • Fax: 847.824.0627
www.powerscontrols.com
Canadian office: Phone: 888.208.8927 • Fax: 888.882.1979
© 2003 Powers, a Watts Industries Co.
A Watts Industries Co.
NOTES
Loading...