S Series |
100 Watt DC-DC Converters |
Wide input voltage ranges from 8...385 V DC 1or 2 isolated outputs up to 48 V DC
4 kV AC I/O electric strengh test voltage
LGA
• Rugged electrical and mechanical design
• Fully isolated outputs
• Operating ambient temperature range –40...71°C with convection cooling
Selection chart
Output 1 |
Output 2 |
Type |
Type |
Type |
Options |
||
Uo nom |
Io nom |
Uo nom |
Io nom |
Input Voltage |
Input Voltage |
Input Voltage |
|
[V DC] |
[A] |
[V DC] |
[A] |
8...35 V DC |
14...70 V DC |
20...100 V DC |
|
5.1 |
16 |
- |
- |
AS 1001-7R |
BS 1001-7R |
FS 1001-7R |
-9, E, D, V, P, T, B1 |
12 |
8 |
- |
- |
AS 1301-7R |
BS 1301-7R |
FS 1301-7R |
-9, E, D, P, T, B1 |
15 |
6.5 |
- |
- |
AS 1501-7R |
BS 1501-7R |
FS 1501-7R |
-9, E, D, P, T, B1 |
24 |
4.2 |
- |
- |
AS 1601-7R |
BS 1601-7R |
FS 1601-7R |
-9, E, D, P, T, B1 |
24 |
4 |
- |
- |
AS 2320-7R |
BS 2320-7R |
FS 2320-7R |
-9, E, D, P, T, B1 |
30 |
3.2 |
- |
- |
AS 2540-7R |
BS 2540-7R |
FS 2540-7R |
-9, E, D, P, T, B1 |
48 |
2 |
- |
- |
AS 2660-7R |
BS 2660-7R |
FS 2660-7R |
-9, E, D, P, T, B1 |
12 |
4 |
12 |
4 |
AS 2320-7R |
BS 2320-7R |
FS 2320-7R |
-9, E, D, P, T, B1 |
15 |
3.2 |
15 |
3.2 |
AS 2540-7R |
BS 2540-7R |
FS 2540-7R |
-9, E, D, P, T, B1 |
24 |
2 |
24 |
2 |
AS 2660-7R |
BS 2660-7R |
FS 2660-7R |
-9, E, D, P, T, B1 |
|
|
|
|
|
|
|
|
Output 1 |
Output 2 |
Type |
Type |
Type |
Options |
||
Uo nom |
Io nom |
Uo nom |
Io nom |
Input Voltage |
Input Voltage |
Input Voltage |
|
[V DC] |
[A] |
[V DC] |
[A] |
28...140 V DC |
44...220 V DC |
67...385 V DC |
|
5.1 |
16 |
- |
- |
CS 1001-7R |
DS 1001-7R |
ES 1001-7R |
-9, E, D, V, P, T, B1 |
12 |
8 |
- |
- |
CS 1301-7R |
DS 1301-7R |
ES 1301-7R |
-9, E, D, P, T, B1 |
15 |
6.5 |
- |
- |
CS 1501-7R |
DS 1501-7R |
ES 1501-7R |
-9, E, D, P, T, B1 |
24 |
4.2 |
- |
- |
CS 1601-7R |
DS 1601-7R |
ES 1601-7R |
-9, E, D, P, T, B1 |
24 |
4 |
- |
- |
CS 2320-7R |
DS 2320-7R |
ES 2320-7R |
-9, E, D, P, T, B1 |
30 |
3.2 |
- |
- |
CS 2540-7R |
DS 2540-7R |
ES 2540-7R |
-9, E, D, P, T, B1 |
48 |
2 |
- |
- |
CS 2660-7R |
DS 2660-7R |
ES 2660-7R |
-9, E, D, P, T, B1 |
|
|
|
|
|
|
|
|
12 |
4 |
12 |
4 |
CS 2320-7R |
DS 2320-7R |
ES 2320-7R |
-9, E, D, P, T, B1 |
15 |
3.2 |
15 |
3.2 |
CS 2540-7R |
DS 2540-7R |
ES 2540-7R |
-9, E, D, P, T, B1 |
24 |
2 |
24 |
2 |
CS 2660-7R |
DS 2660-7R |
ES 2660-7R |
-9, E, D, P, T, B1 |
|
|
|
|
|
|
|
|
www.power-one.com |
1 |
Cassette Style |
|
|
S Series |
|||||
Input |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Input voltage |
6 wide-input ranges (1:5) |
refer to selection chart |
|
|
|
|
|
|
Inrush current limitation |
FS, CS, DS, ES by thermistor |
|
|
|
|
|
|
|
Output |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Efficiency |
Ui nom, Io nom |
|
up to 86% |
|
|
|
|
|
Output voltage setting accuracy |
Ui nom, Io nom |
|
±0.6% Uo nom |
|
|
|||
Output voltage switching noise |
IEC/EN 61204, total |
|
typ. 100 mVpp |
|
||||
Line regulation |
Ui min…Ui max, Io nom |
|
typ. ±0.3% Uo nom |
|
||||
Load regulation |
Ui nom, 10...100% Io nom, symmetrical output load |
typ. 0.4% Uo nom |
|
|||||
Minimum load |
not required |
|
0 A |
|
|
|
||
Current limitation |
rectangular U/I characteristic |
|
typ. 110% Io nom |
|
|
|
||
Operation in parallel |
by current limitation |
|
|
|
|
|
|
|
Hold-up time |
Ui nom, Io nom, CS/DS/ES/FS with ext. diode in input line 12...40 ms |
|
|
|
||||
|
Ui nom, Io nom, AS/BS with ext. diode in input line |
typ. 1.8 ms |
|
|||||
Control and protection |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Input reverse polarity |
built-in fuse not user accessible |
|
|
|
|
|
|
|
Input undervoltage lockout |
|
|
typ. 80% Ui min |
|
|
|
||
Input overvoltage lockout |
|
|
typ. 108% Ui max |
|
|
|||
Input transient protection |
varistor or suppressor diode |
|
|
|
|
|
|
|
Output |
no-load, overload and short circuit proof |
|
|
|
|
|
|
|
Output overvoltage |
suppressor diode in each output |
|
typ. 130% Uo nom |
|
|
|
||
Overtemperature |
switch-off with auto restart |
|
TC typ. 100°C |
|
|
|||
Output voltage adjustment |
|
|
0...110% Uo nom |
|
|
|||
Inhibit |
TTL input, output(s) disabled if open circuit |
|
|
|
|
|
|
|
Status indication |
LEDs: OK, inhibit, overload |
|
|
|
|
|
|
|
Safety |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Approvals |
EN 60950, UL 1950, CSA 22.2 No. 950 |
|
|
|
|
|
|
|
Class of equipment |
|
|
class I |
|
|
|
||
Protection degree |
|
|
IP 30 |
|
||||
Electric strength test voltage |
I/case |
|
2 kV AC |
|
||||
|
I/O |
|
4 kV AC |
|
||||
|
O/case |
|
1 kV AC |
|
||||
|
O/O |
|
0.1 kV AC |
|
||||
EMC |
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
Electrostatic discharge |
IEC/EN 61000-4-2, level 4 (8/15 kV) |
|
criterion A |
|
|
|||
Electromagnetic field |
IEC/EN 61000-4-3, level x (20 V/m) |
|
criterion A |
|
|
|||
Electr. fast transients/bursts |
IEC/EN 61000-4-4, level 4 (2/4 kV) |
|
criterion A |
|
|
|||
Surge |
IEC/EN 61000-4-5, level 3 (2 kV) |
|
criterion A |
|
|
|||
Conducted disturbances |
IEC/EN 61000-4-6, level 3 (10 V) |
|
criterion A |
|
|
|||
Electromagnetic emissions |
CISPR 22/EN 55022, conducted |
|
class B |
|
|
|
www.power-one.com |
2 |