IMP Series |
1...12 Watt DC-DC Converters |
Input voltage range up to 72 V DC 1, 2 or 3 outputs up to 30 V DC
1500 V DC I/O electric strength test voltage
• Wide input range
• Short circuit protection
• Low cost
Selection chart
Output 1 |
Output 2 |
Output 3 |
Type |
|
Type |
|
Type |
Opt. |
|||
Uo nom Io nom |
Uo nom Io nom |
Uo nom Io nom |
Input voltage |
|
Input voltage |
|
Input voltage |
|
|||
[V DC] [mA] |
[V DC] [mA] |
[V DC] [mA] |
4.5...5.5 V DC |
|
10...36 V DC |
|
18...72 V DC |
|
|||
3.3 |
1500 |
- |
- |
- |
- |
5 IMP 6-03-7 |
24 |
IMP 6-03-7 |
48 |
IMP 6-03-7 |
- |
3.3 |
3000 |
- |
- |
- |
- |
- |
24 |
IMP 12-03-7 |
48 |
IMP 12-03-7 |
- |
5 |
200 |
- |
- |
- |
- |
5 IMP 1-05-7 |
- |
|
- |
|
S |
5 |
500 |
- |
- |
- |
- |
- |
24 |
IMP 3-05-7 |
48 |
IMP 3-05-7 |
S |
5 |
1000 |
- |
- |
- |
- |
5 IMP 6-05-7 |
24 |
IMP 6-05-7 |
48 |
IMP 6-05-7 |
- |
5 |
2400 |
- |
- |
- |
- |
- |
24 |
IMP 12-05-7 |
48 |
IMP 12-05-7 |
- |
|
|
|
|
|
|
|
|
|
|
|
|
12 |
84 |
- |
- |
- |
- |
5 IMP 1-12-7 |
- |
|
- |
|
S |
12 |
250 |
- |
- |
- |
- |
- |
24 |
IMP 3-12-7 |
48 |
IMP 3-12-7 |
S |
12 |
500 |
- |
- |
- |
- |
5 IMP 6-12-7 |
24 |
IMP 6-12-7 |
48 |
IMP 6-12-7 |
- |
12 |
1000 |
- |
- |
- |
- |
- |
24 |
IMP 12-12-7 |
48 |
IMP 12-12-7 |
- |
15 |
66 |
- |
- |
- |
- |
5 IMP 1-15-7 |
- |
|
- |
|
S |
15 |
200 |
- |
- |
- |
- |
- |
24 |
IMP 3-15-7 |
48 |
IMP 3-15-7 |
S |
15 |
400 |
- |
- |
- |
- |
5 IMP 6-15-7 |
24 |
IMP 6-15-7 |
48 |
IMP 6-15-7 |
- |
15 |
800 |
- |
- |
- |
- |
- |
24 |
IMP 12-15-7 |
48 |
IMP 12-15-7 |
- |
|
|
|
|
|
|
|
|
|
|
|
|
+5 |
100 |
–5 |
100 |
- |
- |
5 IMP 1-0505-7 |
- |
|
- |
|
S |
+5 |
250 |
–5 |
250 |
- |
- |
- |
24 |
IMP 3-0505-7 |
48 |
IMP 3-0505-7 |
S |
+5 |
500 |
–5 |
500 |
- |
- |
5 IMP 6-0505-7 |
24 |
IMP 6-0505-7 |
48 |
IMP 6-0505-7 |
- |
+5 |
1200 |
–5 |
1200 |
- |
- |
- |
24 |
IMP 12-0505-7 |
48 |
IMP 12-0505-7 |
- |
+12 |
42 |
–12 |
42 |
- |
- |
5 IMP 1-1212-7 |
- |
|
- |
|
S |
+12 |
125 |
–12 |
125 |
- |
- |
- |
24 |
IMP 3-1212-7 |
48 |
IMP 3-1212-7 |
S |
12 |
125 |
12 |
125 |
- |
- |
- |
24 |
IMP 3-12-12-7 |
48 |
IMP 3-12-12-7 |
- |
+12 |
250 |
–12 |
250 |
- |
- |
5 IMP 6-1212-7 |
24 |
IMP 6-1212-7 |
48 |
IMP 6-1212-7 |
- |
+12 |
500 |
–12 |
500 |
- |
- |
- |
24 |
IMP 12-1212-7 |
48 |
IMP 12-1212-7 |
- |
|
|
|
|
|
|
|
|
|
|
|
|
+15 |
33 |
–15 |
33 |
- |
- |
5 IMP 1-1515-7 |
- |
|
- |
|
S |
15 |
100 |
15 |
100 |
- |
- |
- |
24 |
IMP 3-15-15-7 |
48 |
IMP 3-15-15-7 |
- |
+15 |
100 |
–15 |
100 |
- |
- |
- |
24 |
IMP 3-1515-7 |
48 |
IMP 3-1515-7 |
S |
+15 |
200 |
–15 |
200 |
- |
- |
5 IMP 6-1515-7 |
24 |
IMP 6-1515-7 |
48 |
IMP 6-1515-7 |
- |
+15 |
400 |
–15 |
400 |
- |
- |
- |
24 |
IMP 12-1515-7 |
48 |
IMP 12-1515-7 |
- |
|
|
|
|
|
|
|
|
|
|
|
|
5 |
250 |
5 |
250 |
- |
- |
- |
24 |
IMP 3-05-05-7 |
48 |
IMP 3-05-05-7 |
- |
5 |
1500 |
+12 |
200 |
–12 |
200 |
- |
24 |
IMP 12-051212-7 |
48 |
IMP 12-051212-7 |
- |
5 |
1500 |
+15 |
160 |
–15 |
160 |
- |
24 |
IMP 12-051515-7 |
48 |
IMP 12-051515-7 |
- |
|
|
|
|
|
|
|
|
|
|
|
|
www.power-one.ch |
1 |
|
Edition 6/11.2001 |
||
|
Board Mountable |
|
IMP Series |
|||||||||
Input |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Input voltage |
continuous range, 5 V (IMP 1, IMP 6) |
4.5...5.5 V DC |
|
|
|
|
|
|
|
|
|
|
|
continuous range, 24 V |
10...36 V DC |
|
|
||||||
|
|
continuous range, 48 V |
18...72 V DC |
|
|||||||
|
Reverse voltage protection |
shunt diode |
|
|
|
|
|
|
|
|
|
Output |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
Output voltage setting accuracy |
Ui nom, lo nom |
± 2% Uo nom |
|||||||||
Minimum load |
recommended |
20% lo nom |
|
||||||||
Line regulation |
Ui min...Ui max, lo nom |
± 1% Uo nom |
|
||||||||
Load regulation |
Ui nom, 0...100% lo nom, regulated outputs |
2% Uo nom |
|
||||||||
|
|
tracking outputs |
max. 6% Uo nom |
|
|||||||
|
Output voltage switching noise |
Ui nom, 20...100% lo nom, peak-peak, total |
max. 3% Uo nom |
|
|||||||
Efficiency |
Ui nom, lo nom |
up to 83% |
|
||||||||
Control and protection |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
Overload protection |
Ui min, full load |
125% Pi nom |
|
|
|
|
|||||
No-load protection |
|
|
|
|
|
|
|
|
|
|
|
Remote shut down |
positive logic (floating or high signal = on) |
|
|
|
|
|
|
|
|
|
|
Safety and EMC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
Electric strength test voltage |
I/O |
1500 V DC |
|
|
|
|
|||||
Electromagnetic interference |
conducted with external filter |
class B |
|
|
|||||||
Environmental |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
Operating ambient temperature |
Ui nom, lo nom |
–25...71° C |
|||||||||
Storage temperature |
non operational |
–40...100° C |
|
|
|||||||
Relative humidity |
non condensing |
95% |
|
|
|
|
|
|
|||
MTBF |
MIL-HDBK-217F, N2 |
>3'700'000 |
h |
||||||||
Options |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
Industry standard pinout |
IMP 1 and IMP 3 |
S |
|
||||||||
Accessories |
|
|
|
|
|
|
|
|
|
|
DIN and chassis mounting bracket
www.power-one.ch |
2 |
|
Edition 6/11.2001 |
||
|