IMR Series |
3...15 Watt DC-DC Converter |
Input voltage range up to 72 V DC 1, 2 and 3 outputs up to 30 V DC
500 V DC I/O electric strengh test voltage
• Low cost
• Short circuit proof
• Efficiency up to 82%
Selection chart
Output 1 |
Output 2 |
Output 3 |
|
Type |
|
Type |
|
Type |
|||
Uo nom Io nom |
Uo nom Io nom |
Uo nom Io nom |
|
Input voltage1 |
|
Input voltage |
|
Input voltage |
|||
[V DC] [mA] |
[V DC] [mA] |
[V DC] [mA] |
|
9...18 V DC |
|
18...36 V DC |
|
36...72 V DC |
|||
3.3 |
1500 |
- |
- |
- |
- |
12 |
IMR 6-03-2 |
24 |
IMR 6-03-2 |
48 |
IMR 6-03-2 |
3.3 |
3000 |
- |
- |
- |
- |
12 |
IMR 15-03-2 |
24 |
IMR 15-03-2 |
48 |
IMR 15-03-2 |
|
|
|
|
|
|
|
|
|
|
|
|
5 |
500 |
- |
- |
- |
- |
12 |
IMR 3-05-2 |
24 |
IMR 3-05-2 |
48 |
IMR 3-05-2 |
5 |
1000 |
- |
- |
- |
- |
12 |
IMR 6-05-2 |
24 |
IMR 6-05-2 |
48 |
IMR 6-05-2 |
5 |
3000 |
- |
- |
- |
- |
12 |
IMR 15-05-2 |
24 |
IMR 15-05-2 |
48 |
IMR 15-05-2 |
|
|
|
|
|
|
|
|
|
|
|
|
12 |
250 |
- |
- |
- |
- |
12 |
IMR 3-12-2 |
24 |
IMR 3-12-2 |
48 |
IMR 3-12-2 |
12 |
500 |
- |
- |
- |
- |
12 |
IMR 6-12-2 |
24 |
IMR 6-12-2 |
48 |
IMR 6-12-2 |
12 |
1250 |
- |
- |
- |
- |
12 |
IMR 15-12-2 |
24 |
IMR 15-12-2 |
48 |
IMR 15-12-2 |
|
|
|
|
|
|
|
|
|
|
|
|
15 |
200 |
- |
- |
- |
- |
12 |
IMR 3-15-2 |
24 |
IMR 3-15-2 |
48 |
IMR 3-15-2 |
15 |
400 |
- |
- |
- |
- |
12 |
IMR 6-15-2 |
24 |
IMR 6-15-2 |
48 |
IMR 6-15-2 |
15 |
1000 |
- |
- |
- |
- |
12 |
IMR 15-15-2 |
24 |
IMR 15-15-2 |
48 |
IMR 15-15-2 |
+5 |
250 |
–5 |
250 |
- |
- |
12 |
IMR 3-0505-2 |
24 |
IMR 3-0505-2 |
48 |
IMR 3-0505-2 |
+5 |
50 |
–5 |
50 |
- |
- |
12 |
IMR 6-0505-2 |
24 |
IMR 6-0505-2 |
48 |
IMR 6-0505-2 |
+12 |
125 |
–12 |
125 |
- |
- |
12 |
IMR 3-1212-2 |
24 |
IMR 3-1212-2 |
48 |
IMR 3-1212-2 |
+12 |
250 |
–12 |
250 |
- |
- |
12 |
IMR 6-1212-2 |
24 |
IMR 6-1212-2 |
48 |
IMR 6-1212-2 |
+12 |
625 |
–12 |
625 |
- |
- |
12 |
IMR 15-1212-2 |
24 |
IMR 15-1212-2 |
48 |
IMR 15-1212-2 |
|
|
|
|
|
|
|
|
|
|
|
|
+15 |
100 |
–15 |
100 |
- |
- |
12 |
IMR 3-1515-2 |
24 |
IMR 3-1515-2 |
48 |
IMR 3-1515-2 |
+15 |
200 |
–15 |
200 |
- |
- |
12 |
IMR 6-1515-2 |
24 |
IMR 6-1515-2 |
48 |
IMR 6-1515-2 |
+15 |
500 |
–15 |
500 |
- |
- |
12 |
IMR 15-1515-2 |
24 |
IMR 15-1515-2 |
48 |
IMR 15-1515-2 |
|
|
|
|
|
|
|
|
|
|
|
|
5 |
2000 |
+12 |
200 |
–12 |
200 |
12 |
IMR 15-051212-2 |
24 |
IMR 15-051212-2 |
48 |
IMR 15-051212-2 |
5 |
2000 |
+15 |
200 |
–15 |
200 |
12 |
IMR 15-051515-2 |
24 |
IMR 15-051515-2 |
48 |
IMR 15-051515-2 |
|
|
|
|
|
|
|
|
|
|
|
|
1 12 IMR 3 and 12 IMR 15 types: output current Io nom see: Application Note - Output Data
www.power-one.com |
1 |
|
Edition 5/07.2001 |
||
|
Board Mountable |
|
IMR Series |
||||||||
Input |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Input voltage |
continuous range, 12 V |
9...18 V DC |
|
|
|
|
|
|
|
|
|
|
continuous range, 24 V |
18...36 V DC |
|
|
|||||
|
|
continuous range, 48 V |
36...72 V DC |
|
||||||
|
Protection |
reverse input voltage, current limitation |
|
|
|
|
|
|
|
|
Output |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
Efficiency |
|
up to 82% |
|
|
|
|
|
|||
Minimum load |
recommended |
20% Io nom |
|
|||||||
Line regulation |
Ui min...Ui max, Io nom |
± 1% |
|
|
|
|||||
Load regulation |
Ui nom, 0...100% Io nom, single output models |
2% |
|
|
|
|||||
|
|
dual output models (traching) |
5% |
|
|
|||||
|
|
triple output models (traching) |
6% |
|
||||||
|
Ripple and noise |
Ui nom, (20...100%) Io nom |
2% Uo nom |
|
||||||
Protection |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Overload protection |
Ui nom, full load |
125% Pi nom |
|
|
|
|
||||
No-load protection |
|
|
|
|
|
|
|
|
|
|
Safety |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
I/O electric strength test |
per EN 60950 |
500 V DC |
|
|
|
|
||||
Electromagnetic interference |
conducted per EN 55022 with external filter |
class B |
|
|
||||||
Environmental |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Operating temperature |
Ui nom, Io nom |
–10...50° C |
||||||||
Storage temperature |
non operational |
–40...100° C |
|
|
||||||
Relative humidity |
non condensing |
95% |
|
|
|
|
|
|||
MTBF |
per MIL-HDBK-217F, N2 |
>3'000'000 |
h |
|||||||
Options |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Extended temperature range |
–25...71° C, ambient, operating, IMR 3, IMR 6 |
-7 |
|
|
|
|
|
|
|
www.power-one.com |
2 |
|
Edition 5/07.2001 |
||
|