QUICK SETUP

1 2

Remove box and pallet

 

Position cooler on level surface

5

For setup, Kuul® evaporative media should appear wet before starting the fan. Check the water gauge to

monitor water level in tank. The water adjustment valve on each portable evaporative cooler is set at max flow.

However, ensure the knob is turned completely to the right before use. Turn to the left to increase water flow.

If entrainment occurs - water is spitting from the front of the product - use the valve to decrease the water flow until entrainment ceases.

Fill the tank, then turn on the pump switch and the fan

3 4

Fill tank or attach water hose*

 

Plug into appropriate outlet

*Maximum water pressure 50 psi/345 kPa

6 Your Portacool portable evaporative cooler is meant to be used in an open-air environment, such as a patio. If you plan to use your evaporative cooler in a more closed environment – such as a garage, sunroom or barn – you must provide adequate ambient airflow to ensure your evaporative cooler works at its highest efficiency. When using in a semi-closed environment, be sure to leave a door or window open to allow for the proper amount of airflow.

Ensure proper airflow is available

SAFETY

OPERATION WARNINGS

1)Not for use by children

2)Not for use by persons with reduced physical, sensory or mental capabilities

3)Not for use by persons who have not reviewed the owner’s manual and familiarized themselves with the operation of the product.

SAFE OPERATION

To reduce the risk of electric shock, fire or injury:

Do not operate any evaporative cooler with a damaged cord or plug.

Do not run power cord under carpeting or cover with throwrugs, runners or similar coverings. Arrange power cord away from traffic areas to avoid tripping hazards.

Read the evaporative cooler’s instructions, owner’s manual and labels throughly before use.

Always unplug the power cord to the evaporative cooler before performing inspections or repairs.

Always unplug the evaporative cooler during filling and cleaning.

Do not step on or roll over power cord with heavy or sharp objects.

Do not operate evaporative cooler unless all Kuul® evaporative media is securely in place.

Test the GFCI receptacle or breaker monthly to ensure it is functioning properly if applicable.

Remove the plug from the electrical receptacle by pulling on the plug, not the power cord.

Operation near open flames or sparks is not recommended.

If operating near open flame or sparks, ensure the pump is continuously running in order to saturate and wet Kuul

evaporative media.

When cleaning your evaporative cooler, ensure water does not get into the motor or electrical system to prevent damage.

The use of extension cords with your evaporative cooler is not recommended. However, if the owner determines that his or her circumstance or intended use requires the use of an extension cord, the following requirements must be met:

-- Use properly grounded 14 AWG or greater for

PACJS220-260

-- Use properly grounded 12 AWG or greater for PACJS270

-- Extension cord must not exceed 50 feet (15.24 meters) in length; and

-- Extension cord must be properly grounded

Evaporative coolers should not be modified in any way (other than repairs made by qualified individuals with Portacool replacement parts).

If the evaporative cooler is damaged or malfunctions, do not continue to operate it. Refer to the warranty,

troubleshooting or FAQ sections of this owner’s manual, call Portacool, LLC Customer Service at (936) 598-5651 or

(800) 695-2942, or email support@portacool.com.

OVERVIEW

PACJS220

Water

adjustment valve

*Products not sold in North America or products with 220/50 volt requirements will not have a GFCI/ELCI.

Liquid Level Indicator

Hose connection

Manual water fill

Heavy duty casters

Two inch drain on bottom

Serial plate

Control panel

Oscillating louvers

Cord wrap

Power cord with GFCI*

Kuul® Comfort

MicroTech

evaporative media

OVERVIEW

PACJS230

Serial plate

Water

 

adjustment valve

Oscillating louvers

 

Liquid Level Indicator

Control panel

 

Hose connection

 

 

Cord wrap

Manual water fill

 

 

Power cord

 

with GFCI*

 

Heavy duty casters

*Products not sold in North America or

Two inch drain

products with 220/50 volt requirements will

on bottom

not have a GFCI/ELCI.

Kuul® Comfort MicroTech evaporative media

OVERVIEW

PACJS240

Water adjustment valve

Liquid Level Indicator

Hose connection

Manual water fill

Heavy duty

casters

*Products not sold in North America or

Two inch drain

products with 220/50 volt requirements will

on bottom

not have a GFCI/ELCI.

Serial plate

Control panel

Cord wrap

Power cord with GFCI*

Kuul® Comfort evaporative media

OVERVIEW

PACJS250

Serial plate

Water adjustment valve

Liquid Level Indicator

Control panel

Manual water fill

Cord wrap

Hose connection

Power cord with GFCI*

Kuul® Comfort

evaporative media

Heavy duty casters

Two inch drain

*Products not sold in North America or on bottom products with 220/50 volt requirements will

not have a GFCI/ELCI.

OVERVIEW

PACJS260

 

Serial plate

Water

Control panel

adjustment valve

 

Liquid Level Indicator

 

Hose connection

 

Manual water fill

Cord wrap

 

Power cord

 

with GFCI*

 

Kuul® Comfort

 

evaporative media

Heavy duty casters

Two inch drain

*Products not sold in North America or on bottom products with 220/50 volt requirements will

not have a GFCI/ELCI.