1 2
Remove box and pallet |
|
Position cooler on level surface |
5
For setup, Kuul® evaporative media should appear wet before starting the fan. Check the water gauge to
monitor water level in tank. The water adjustment valve on each portable evaporative cooler is set at max flow.
However, ensure the knob is turned completely to the right before use. Turn to the left to increase water flow.
If entrainment occurs - water is spitting from the front of the product - use the valve to decrease the water flow until entrainment ceases.
Fill the tank, then turn on the pump switch and the fan
3 4
Fill tank or attach water hose* |
|
Plug into appropriate outlet |
*Maximum water pressure 50 psi/345 kPa
6 Your Portacool portable evaporative cooler is meant to be used in an open-air environment, such as a patio. If you plan to use your evaporative cooler in a more closed environment – such as a garage, sunroom or barn – you must provide adequate ambient airflow to ensure your evaporative cooler works at its highest efficiency. When using in a semi-closed environment, be sure to leave a door or window open to allow for the proper amount of airflow.
Ensure proper airflow is available
SAFETY
OPERATION WARNINGS
1)Not for use by children
2)Not for use by persons with reduced physical, sensory or mental capabilities
3)Not for use by persons who have not reviewed the owner’s manual and familiarized themselves with the operation of the product.
SAFE OPERATION
To reduce the risk of electric shock, fire or injury:
•Do not operate any evaporative cooler with a damaged cord or plug.
•Do not run power cord under carpeting or cover with throwrugs, runners or similar coverings. Arrange power cord away from traffic areas to avoid tripping hazards.
•Read the evaporative cooler’s instructions, owner’s manual and labels throughly before use.
•Always unplug the power cord to the evaporative cooler before performing inspections or repairs.
•Always unplug the evaporative cooler during filling and cleaning.
•Do not step on or roll over power cord with heavy or sharp objects.
•Do not operate evaporative cooler unless all Kuul® evaporative media is securely in place.
•Test the GFCI receptacle or breaker monthly to ensure it is functioning properly if applicable.
•Remove the plug from the electrical receptacle by pulling on the plug, not the power cord.
•Operation near open flames or sparks is not recommended.
•If operating near open flame or sparks, ensure the pump is continuously running in order to saturate and wet Kuul
evaporative media.
•When cleaning your evaporative cooler, ensure water does not get into the motor or electrical system to prevent damage.
•The use of extension cords with your evaporative cooler is not recommended. However, if the owner determines that his or her circumstance or intended use requires the use of an extension cord, the following requirements must be met:
-- Use properly grounded 14 AWG or greater for
PACJS220-260
-- Use properly grounded 12 AWG or greater for PACJS270
-- Extension cord must not exceed 50 feet (15.24 meters) in length; and
-- Extension cord must be properly grounded
•Evaporative coolers should not be modified in any way (other than repairs made by qualified individuals with Portacool replacement parts).
•If the evaporative cooler is damaged or malfunctions, do not continue to operate it. Refer to the warranty,
troubleshooting or FAQ sections of this owner’s manual, call Portacool, LLC Customer Service at (936) 598-5651 or
(800) 695-2942, or email support@portacool.com.
OVERVIEW
PACJS220
Water
adjustment valve
*Products not sold in North America or products with 220/50 volt requirements will not have a GFCI/ELCI.
Liquid Level Indicator
Hose connection
Manual water fill
Heavy duty casters
Two inch drain on bottom
Serial plate
Control panel
Oscillating louvers
Cord wrap
Power cord with GFCI*
Kuul® Comfort
MicroTech
evaporative media
OVERVIEW
PACJS230
Serial plate
Water |
|
adjustment valve |
Oscillating louvers |
|
|
Liquid Level Indicator |
Control panel |
|
|
Hose connection |
|
|
Cord wrap |
Manual water fill |
|
|
Power cord |
|
with GFCI* |
|
Heavy duty casters |
|
*Products not sold in North America or |
Two inch drain |
|
products with 220/50 volt requirements will |
||
on bottom |
||
not have a GFCI/ELCI. |
Kuul® Comfort MicroTech evaporative media
OVERVIEW
PACJS240
Water adjustment valve
Liquid Level Indicator
Hose connection
Manual water fill
Heavy duty
casters
*Products not sold in North America or |
Two inch drain |
|
products with 220/50 volt requirements will |
||
on bottom |
||
not have a GFCI/ELCI. |
Serial plate
Control panel
Cord wrap
Power cord with GFCI*
Kuul® Comfort evaporative media
OVERVIEW
PACJS250
Serial plate
Water adjustment valve
Liquid Level Indicator |
Control panel |
Manual water fill
Cord wrap
Hose connection
Power cord with GFCI*
Kuul® Comfort
evaporative media
Heavy duty casters
Two inch drain
*Products not sold in North America or on bottom products with 220/50 volt requirements will
not have a GFCI/ELCI.
OVERVIEW
PACJS260
|
Serial plate |
Water |
Control panel |
adjustment valve |
|
Liquid Level Indicator |
|
Hose connection |
|
Manual water fill |
Cord wrap |
|
Power cord |
|
with GFCI* |
|
Kuul® Comfort |
|
evaporative media |
Heavy duty casters
Two inch drain
*Products not sold in North America or on bottom products with 220/50 volt requirements will
not have a GFCI/ELCI.