Planet ER-700 User Manual

Page 1
ACT
PAR
Partition LED
Quick Installation Guide
ER-700
7-Port Ethernet Repeater
PAR LNK/ACT
BNC1 BNC2 BNC3 BNC4 AUI UTP1 UTP1UTP2 UTP2
Link/ Activity LED
Activity LED
EMER700-1
ISO9002
PLANET Technology Corp.
PWR
100~240 VAC
50/60 HZ
1-Port AUI 4-port BNC 2-Port UTP
ER-700
Page 2
Packing List
100~240 VAC
100~240 VAC
LED
ER-700
7-Port Ethernet Repeater
PAR LINK
BNC1 BNC2 BNC3 BNC4 AUI UTP1 UTP1UTP2 UTP2
ACT
System Description
Front Panel
ER-700
7-Port Ethernet Repeater
BNC1 BNC2 BNC3 BNC4 AUI UTP1 UTP1UTP2 UTP2
LEDs UTP Ports Power
PAR LINK
Quick
Installation
Guide
for
PWR
50/60 HZ
ER-700
ER-700 x1 Power Cord x1 Installation Guide x 1 T-Connector x 4 50ohm Terminator x 4
ACT
PWR
50/60 HZ
100~240VAC
ER-700
ER-700
Rear Panel
AUI port
BNC ports
Page 3
LEDs Indicator
LED Status Description Power Steady Green System Power OK Activity Blinking Green Indicate port/segment is receiving /
transmitting data packet LINK (UTP) Steady Yellow Indicate UTP port Link detected PAR
(BNC/AUI)
Steady Yellow Indicate the port is partitioned off
to isolate this bad port from the rest
of the network. It will turn off as
soon as the problem is corrected.
Cabling Guide
Type 10Base-2 10Base-5 10Base-T Topology Bus Bus Star Maximum nodes per cable segment Cable types RG-58
Maximum length of a cable segment Maximum repeater sets
30 100 2
RG-11 UTP,
A, U, A/U
606 feet ( 185 m)
1640 feet (500m)
4
AWG22~ 26 328 feet (100 m )
UTP Cable Type
2136
213
6
6
3
2
1
Straight Through
Cable
Pin 1 Pin 1 Pin 2 Pin 2 Pin 3 Pin 3 Pin 6 Pin 6
Crossove Cable
Pin 1 Pin 3 Pin 2 Pin 6 Pin 3 ↔ Pin 1 Pin 6 Pin 2
Page 4
Specification
Model ER-700
Transmission Technique Access Method CSMA/CD Standard Compliance IEEE802.3, 10Base-T, 10Base-2,
Ports 4 x BNC / 2 x UTP / 1 x AUI LEDs System
Dimension (WxDxH) 240 mm x 135 mm x 44 mm
Weight 1.8 Kg (3.9lbs) Power Input 90~240VAC, 50~60Hz Power Consumption 5 W maximum Operating Temperature Humidity 10~80%, non-condensing Emission FCC part 15 Class A, CE mark
Baseband
10Base-5
: Power UTP AUI/BNC
(9.4” x 5.3” x 1.7”)
0~70 degree C
: LINK, ACT
: PAR, ACT
Page 5
Application
Segment 2 10Base-5
Segment 3 10Base-2
Segment 4 10Base-2
Segment 5 10Base-2
Note: Maximum 5 Segments (4 Repeaters) allowed.
Each segment should terminated with a 50-ohm terminator in both ends.
Segment 1 10Base-2
Connecting the Hub to AC Power
After making network connections as described in the preceding sections, you are ready to plug the hub in and turn it on.
The input voltage is from 90 to 240 volts AC and any frequency from 50 to 60 hertz. Adjustment to the power source is automatic; there is no switch to set.
Before plugging the hub in, make sure the power cord (1) is long enough to reach an AC wall outlet of an approved
type,
(2) has plugs that match both the hub's power inlet and the
type of wall outlet you will use, and
(3) Conforms to safety regulations in your area.
In most parts of the world you must use a three-conductor power cord with an integral three-prong grounding plug.
Page 6
If the supplied power cord does not meet all three requirements given above, contact your computer equipment dealer and obtain one that does. Do not use an extension cord or multi-socket adapter; do not attempt to use a cord designed for any other kind of power inlet or wall outlet; do not use a cord that fails to meet safety standards in your part of the world.
Power Failure
To prevent costly equipment damage and downtime, please consider installing a surge suppression device or a UPS (un-interrupted power supply).
Troubleshooting
Check LED Indicators
LED indicators will act follow section “LED Indicators”, please check the status all the time to have a quick diagnostic of the network status.
Partitioning
When a problem occurs on a segment connected to the repeater, the segment is automatically partitioned to isolate the problem from the rest of the network. The PAR LED indicator of the port should light up and remain this way until the problem is corrected.
Check the cable connection in this segment carefully.
Make sure all the devices are well-connected.
Segment termination. Make sure the segment are
terminated by a 50-ohm terminator.
After the problem corrected, ER-700 will automatically re­connect the partitioned segments to the networks.