NF series modular pre-wired technopolymer switches
Selection diagram for item combinations of the NF series
0AA 0AB 0AC 0AE 0BB 0BE 0BG 0CB 0CH
Short plungerPlunger Long plungerPlunger with
external gasket
Roller plunger Roller plunger
with external
gasket
Roller plunger
with external
gasket
Roller lever Angled lever
with roller
ACTUATORS
NF
0AB-W5 0BB-H0W5 0BB-W5
Plunger Roller plunger Roller plunger
0HB-W5
Flexible rod
with plastic tip
0HE-W5
Flexible rod
0HH-W5
Flexible rod
with needle
2KA 2KB 2KC 2KD 2KE 2KF 2KG 2KH 2KP
Plastic
swivelling
lever, straight,
with roller
Ø 18 mm
Metal
swivelling
lever, straight,
adjustable,
with roller
Ø 18 mm
Metal
swivelling
lever, profiled,
adjustable,
with roller
Ø 14 mm
Metal
swivelling
lever, profiled,
adjustable,
with roller
Ø 14 mm
Metal
swivelling
lever, profiled,
adjustable,
with roller
Ø 20 mm
Metal
swivelling
lever, straight,
adjustable,
with roller
Ø 20 mm
Metal
swivelling
lever, profiled,
adjustable,
with roller
Ø 20 mm
Metal
swivelling
lever,
profiled,
adjustable,
with roller
Ø 20 mm
adjustment and
roller Ø 20 mm
CONTACT
BLOCKS
B11 G11 H11 L11
CONNECTORS
1NO+1NC
snap action
1NO+1NC
slow action
1NO+1NC
slow action,
make before
break
Metal
swivelling
lever, straight,
with extended
1NO+1NC
slow action,
close
125
DMKSMKDM0.2
M12 connector,
right
M12 connector,
bottom
SAK
AMP connector,
bottom
CABLES
connector with cable
PVC cable IEC 60332‑1 (standard)
DN
PVC cable CEI 20‑22 II
DG
PUR cable, halogen free
DH
product options
Sold separately as accessory
cable and M12
connector
B02 G02
2NC
snap action
2NC
slow action
B12 G12 H12 L12
1NO+2NC
snap action
1NO+2NC
slow action
1NO+2NC
slow action,
make before
break
slow action,
B22 G22 H22 L22
2NO+2NC
snap action
2NO+2NC
slow action
2NO+2NC
slow action,
make before
break
General Catalogue Detection 2017-2018
slow action,
1NO+2NC
close
2NO+2NC
close
4
0CP
Unidirectional
roller lever
0CV 0EB 0EE 0FB 0GB
Adjustable angled
roller lever
Plunger with M12
threaded fitting
Plunger with M12
threaded fitting,
external gasket
Roller plunger
with M12
threaded fitting
Plunger with Ø
6 mm ball
0HB0HE0HH
Flexible rod with
plastic tip
Flexible
rod
Flexible rod
with needle
SEPARATE
ACTUATORS
See page 135
2LB2LE2LH2LL
Metal swivelling
lever with
stainless
steel rod
3 x 3 x 125 mm,
adjustable
Metal swivelling
lever with
stainless
steel rod
Ø 3 x 125 mm,
adjustable
Metal swivelling
lever with
glass fibre rod
Ø 6 x 200 mm,
adjustable
Metal swivelling
lever with
flexible rod,
adjustable
2LP
Metal swivelling
lever with
porcelain roll,
adjustable
200
Metal head
for swivelling
lever actuators
Code structure Attention! The feasibility of a code number does not mean the effective availability of a product. Please contact our sales office.
articleoptions
NF B110AB-DN2 GR7T6W5
Housing
NF
technopolymer, hole spacing 20 mm
Contact block
B11
1NO+1NC, snap action (standard)
B02
2NC, snap action (standard)
B12
1NO+2NC, snap action (standard)
B22
2NO+2NC, snap action (standard)
G11
1NO+1NC, slow action (standard)
G02
2NC, slow action (standard)
G12
1NO+2NC, slow action (standard)
G22
2NO+2NC, slow action
H11
1NO+1NC, slow action, make before break
H12
1NO+2NC, slow action, make before break
H22
2NO+2NC, slow action, make before break
L11
1NO+1NC, slow action, close
L12
1NO+2NC, slow action, close
L22
2NO+2NC, slow action, close
Other contact blocks on request.
Actuator heads
0
without head
2
head for swivelling lever actuators
Actuators
AA
short plunger
AB
plunger
...
........................
Output direction
D
cable or connector, right
S
connector, bottom
Rollers
R30
R29
R18
R23
R7
R22
R24
R19
R25
Contact type
silver contacts (standard)
G
silver contacts, 1 µm gold coating
Connection type
cable, length: 0.2 m with M12 connector
0.2
(available for DM0.2 versions only)
2
cable, length: 2 m (standard)
5
cable, length 5 m (other cable lengths available on request)
K
integrated connector
Cable or connector type
N
PVC cable IEC 60332‑1 (standard)
G
PVC cable CEI 20‑22 II
H
PUR cable, halogen free
M
M12 connector
A
AMP Superseal 1.5 connector
Redirection
without redirection
W5
90° redirection
Ambient temperature
‑25°C … +80°C (standard)
T6
‑40 °C … +80 °C
standard roller
stainless steel Ø 10.6 mm
stainless steel Ø 13 mm
technopolymer, Ø 14 mm
stainless steel Ø 14 mm
technopolymer, Ø 18 mm
technopolymer, Ø 20 mm
stainless steel Ø 20 mm
technopolymer, Ø 22 mm
technopolymer, Ø 35 mm
General Catalogue Detection 2017-2018
126
4
NF series modular pre-wired technopolymer switches
Main features
•Technopolymer housing, right or bottom cable
output
•Protection degrees IP67 and IP69K
•2 types of integrated cable available
•Versions with M12 connector suitable for
safety applications
•Versions with AMP connector
•14 contact blocks available
•37 actuators available
Quality marks:
Technical data
Housing
Housing made of glass fibre reinforced technopolymer, self‑extinguishing, shock‑proof
and with double insulation
Versions with integrated cable, standard length 2 m. Other lengths 0.5 … 10 m or
special cables available on request.
Versions with integrated M12 connector.
Versions with 0.2 m cable length and M12 connector, other lengths 0.1 … 3 m
available on request
Protection degree: IP67 acc. to EN 60529
Corrosion resistance in saline mist: ≥ 300 hours in NSS acc. to ISO 9227
General data
Ambient temperature for switches without cable: ‑25°C … + 80°C (standard)
Ambient temperature for switches with cable:See table on page 128
Max. actuation frequency: 3600 operating cycles/hour
Mechanical endurance: 20 million operating cycles
Mounting position:any
Safety parameter B
10D
Mechanical interlock, not coded:type 1 acc. to EN ISO 14119
Tightening torques for installation:see page 211‑222
Electrical data
Rated impulse withstand voltage (U
Conditional short circuit current: 1000 A acc. to EN 60947‑5‑1
Pollution degree: 3
In compliance with standards:
IEC 60947‑5‑1, EN 60947‑5‑1, IEC 60204‑1, EN 60204‑1, EN ISO 14119,
EN ISO 12100, EN 60529, ISO 20653, UL 508, CSA 22.2 No.14.
.
IP69K acc. to ISO 20653
(Protect the cables from direct high‑pressure and
high‑temperature jets)
Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU.
Positive contact opening in conformity with standards:
IEC 60947‑5‑1, EN 60947‑5‑1.
Installation for safety applications:
Use only switches marked with the symbol next to the product code. Always connect the safety circuit to the NC contacts (normally
closed contacts: see “Internal cable wiring” on page 128) as required by EN ISO 14119, paragraph 5.4 for specific interlock applications and
EN ISO 13849-2 tables D3 (well‑tried components) and D.8 (failure exclusions) for safety applications in general. Actuate the switch at least
up to the positive opening travel shown in the travel diagrams on page 220. Actuate the switch at least with the positive opening force,
reported in brackets below each article, next to the actuating force value. All applicable standards must be respected too.
If not expressly indicated in this chapter, for correct installation and utilization of all articles see the instructions given on pages
211 to 222.
Important: Switch off the circuit voltage before disconnecting the connector from the switch. The connector is not suitable for
separation of electrical loads.
Features approved by IMQ
Rated insulation voltage (Ui):250 Vac
Conventional free air thermal current
):
(I
th
Protection against short circuits
(fuse):
Rated impulse withstand voltage
):
(U
imp
Protection degree of the housing:IP67
MA terminals (crimped terminals)
Pollution degree: 3
Utilization category: AC15 / DC13 (with connector)
Operating voltage (U
Operating current (I
Forms of the contact element: X, Y, X+Y, X+X, Y+Y, Y+Y+X, X+X+Y, X+X+Y+Y, Zb
Positive opening of contacts on contact blocks B01, B11, B02, B12, B21, B22,
G01, G11, G02, G12, G21, G22, L01, L11, L02, L12, L21, L22, H01, H11, H02,
H12, H21, H22
In compliance with standards: EN 60947‑1, EN 60947‑5‑1 + A1:2009,
fundamental requirements of the Low Voltage Directive 2014/35/EU.
Please contact our technical department for the list of approved products.
):250 Vac (50 Hz) / 24 Vdc (with connector)
e
): 3 A / 2 A (with connector)
e
10 A (1‑2 contacts) / 6 A (2‑3 contacts) /
4 A (4 contacts or 4‑pole M12 connector)
10 A (1‑2 contacts) / 6 A (2‑3 contacts) /
4 A (4 contacts or 4‑pole M12 connector) type gG
4 kV
Features approved by UL
Utilization categories R300 pilot duty (28 VA, 125‑250 Vdc)
B300 pilot duty (360 VA, 120‑240 Vac) (1‑2‑3 cont.)
C300 pilot duty (180 VA, 120‑240 Vac) (4 cont.)
Housing features type 1, 4X “indoor use only”, 12.
Housing features for the version with 1‑2 contacts and type N cable
Type 1, 4X “indoor use only”
In compliance with standard: UL 508, CSA 22.2 No.14
Please contact our technical department for the list of approved products.
127
General Catalogue Detection 2017-2018
Ambient temperatures for switches with cable and electrical data
1
2
345
6
7
8
1-2 NC3-4 NC5-6 NO7-8 NO
1
2
345
6
7
8
3-4 NC5-6 NC7-8 NO
4123
4
1
2
3
1-2 NC3-4 NO
4123
4
1
2
3
1-2 NC3-4 NC
1
1
3-4 NO
3-4 NC
Connection type
Contact block2 contacts3 contacts4 contacts
Cable or connector type
Conductors
Application field
In compliance with
standards
Sheath
Self-extinguishing
Oil resistant
NG
4x0.75 mm24x0.75 mm24x0.75 mm2 6x0.5 mm
GeneralGeneral
05VV-F05VV-F05EQ-H03VV-F03VV-F03E7Q-H03VV-H03VV-H
PVCPVCPUR
IEC 60332‑1‑2
IEC 60332‑1‑3
IEC 60332‑1‑2
IEC 60332‑1‑3
IEC 60332‑3
CEI 20‑22 II
//UL 758//UL 758ISO 6722-1ISO 6722-1
Cable features
Max. speed
Max. acceleration
//300m/min//300m/min50m/min50m/min
//30m/s
Output with cable
HNNH
2
8x0.34 mm2 8x0.34 mm2 4x0.25 mm28x0.25mm2
General,
mobile installation
HALOGEN FREE
IEC60332‑1‑2
IEC60332‑1‑3
2
GeneralGeneral
PVCPVCPUR
IEC 60332‑1‑2
IEC 60332‑1‑3
IEC 60332‑1‑2
IEC 60332‑1‑3
//30m/s
General,
mobile installation
HALOGEN FREE
IEC60332‑1‑2
IEC60332‑1‑3
2
Output with M12 connector
2 contacts3 or 4 contacts2 contacts
M12 connector,
5-pole
GeneralGeneralGeneral
PVCPVC
IEC60332‑3
CEI 20‑22 II
2
5m/s
M12 connector,
8-pole
IEC60332‑3
CEI 20‑22 II
2
5m/s
Output with AMP
connector
AMP Superseal
1.5 connector
4
/
/
/
/
/
/
Minimum bending radius
Outer diameter
End stripped
Copper conductors IEC 60228
Cable,
fixed installation
Cable, flexible installation
Cable, mobile installation
Cable, fixed installation
Cable, flexible installation
Cable, mobile installation
extended (T6)standard
Ambient temperature with cable
Thermal current Ith
Rated insulation voltage Ui
Protection against short circuits
(fuse)
24 V
125 V
DC13
category
Electrical data
Utilization
250 V
24 V
120 V
AC15
category
Utilization
250 V
Approvals
70 mm70 mm70 mm108 mm94mm70 mm75 mm90 mm
7 mm7 mm7 mm7 mm7 mm7 mm5 mm5 mm
80 mm80 mm80 mm80 mm80 mm80 mm
Class 5Class 5Class 6 Class 5Class 5Class 6Class 6Class 6
‑25°C +70°C
+5°C +70°C
/
/
/
/
10 A
250 Vac
10 A 500 V
type gG
2 A
0.4 A
0.3 A
4 A
4 A
4 A
CE cULus
IMQ EAC
CCC
‑25°C +70°C
+5°C +70°C
/
/
/
/
10 A
250 Vac
10 A 500 V
type gG
2 A
0.4 A
0.3 A
4 A
4 A
4 A
CE
EAC CCC
‑25°C +80°C
‑25°C +80°C
‑25°C +80°C
‑40°C +80°C
‑40°C +80°C
‑40°C +80°C
10 A
250 Vac
10 A 500 V
type gG
2 A
0.4 A
0.3 A
4 A
4 A
4 A
CE
EAC
‑25°C +80°C
‑5°C +80°C
/
/
/
/
6 A
250 Vac
6 A 500 V
type gG
2 A
0.4 A
0.3 A
3 A
3 A
3 A
CE cULus
IMQ EAC
CCC
‑25°C +80°C
‑5°C +80°C
/
/
/
/
3 A
250 Vac
3 A 500 V
type gG
2 A
0.4 A
0.3 A
3 A
3 A
3 A
CE cULus
IMQ EAC
CCC
‑25°C +80°C
‑25°C +80°C
‑25°C +80°C
‑40°C +80°C
‑40°C +80°C
‑40°C +80°C
3 A
250 Vac
3 A 500 V
type gG
2 A
0.4 A
0.3 A
3 A
3 A
3 A
CE EAC
///
‑25°C +80°C
‑25°C +80°C
‑15°C +80°C
/
/
/
‑25°C +80°C
‑25°C +80°C
‑15°C +80°C
4 A
250 Vac
300 Vdc
4 A 500 V
type gG
2 A 500 V
type gG
2 A
0.4 A
0.3 A
4 A
4 A
4 A
CE cULus
IMQ EAC
CCC
CE cULus
EAC CCC
/
/
/
2 A
30 Vac
36 Vdc
2 A
/
/
2 A
/
/
/
/
/
/
/
/
/
/
/
10 A
250 Vac
300 Vdc
10 A 500 V
type gG
2 A
0.4 A
0.3 A
4 A
4 A
4 A
CE cULus EAC
CCC
Internal cable wiring
2NO+2NC1NO+2NC1NO+1NC2NC
black
black-white
red
red-white
brown
blue
violet
violet-white
General Catalogue Detection 2017-2018
black
black-white
red
red-white
brown
blue
black
grey
brown
blue
black
grey
brown
blue
Connector pin assignment
2NO+2NC1NO+2NC1NO+1NC2NC
2
345
1-2 NC
3-4 NC
5-6 NO
7-8 NO
7
6
8
2
345
3-4 NC
5-6 NC
7-8 NO
7
6
8
4 1 2 3
1
4
2
3
1-2 NC
Female connectors see page 198
4 1 2 3
2
1-2 NC
1
4
3
128
4
NF series modular pre-wired technopolymer switches
Important: Always check that the applied electric load is within the voltage and current limits defined for the connectors. See tables on page 118 and 128.
metal connectors for NA and NB housingstechnopolymer connectors for NF housings