Pizzato FC series position switches Data Sheet

Page 1
2
FC series position switches
Selection diagram
ACTUATORS
01 08 10 11 18 19 02 04 05
External rubber
gasket
Ball Ø 8 mm,
stainless steel
Ball Ø 12.7
mm, stainless
steel
Glass fibre rod
31 51 52 57 35 56
Adjustable
lever
Adjustable
safety lever
CONDUIT ENTRY
CONTACT
BLOCKS
Threaded conduit entry
M2
3 33 34
snap action
M20x1.5 (standard) PG 11
1NO+1NC
slow action
K23
K27
2NC
slow action
With cable gland
for cables Ø 6 … 12 mm for cables Ø 3 … 7 mm
With M12 metal connector
K50
5-pole, bottom
45
product options
Sold separately as accessory
General Catalogue Detection 2017-2018
Page 2
15 16 20 21 25 34 32 33 36 53
Roller, stainless
steel
External rubber
gasket
Roller, stainless
steel
Round rod,
stainless steel
Square rod Glass fibre rod
76 38 58
Rope switch for
signalling
Without actuator
Without actuator
2
Porcelain
roller
SEPARATE
ACTUATORS
See page 51
Code structure Attention! The feasibility of a code number does not mean the effective availability of a product. Please contact our sales office.
article options
options
FC 302-GM2K50R24T6
Housing
FC
metal, one conduit entry
Contact block
3
1NO+1NC, snap action
33
1NO+1NC, slow action
34
2NC, slow action
Actuators
01
short plunger
02
roller lever
05
angled lever with roller
…
........................
R24
R25
R26
R27
Ambient temperature
-25°C … +80°C (standard)
T6
-40°C … +80°C
Rollers
standard roller
stainless steel Ø 20 mm
(for actuators 02, 05, 31, 35, 51, 52, 56, 57)
technopolymer, Ø 35 mm
(for actuators 31, 35, 51, 52, 56, 57)
rubber, Ø 40 mm
R5
(for actuators 31, 35, 51, 52, 56, 57)
rubber, Ø 50 mm
(for actuators 31, 35, 51, 52, 56, 57)
rubber, protruding, Ø 50 mm
(for actuators 35 and 36)
Contact type
silver contacts (standard)
silver contacts, 1 µm gold coating (not
G
for contact block 3)
General Catalogue Detection 2017-2018
Threaded conduit entry
M2
M20x1.5 (standard)
PG11
Pre-installed cable glands
no cable gland (standard)
K23
cable gland for cables Ø 6 … 12 mm
K27
cable gland for cables Ø 3 … 7°mm
K50
M12 metal connector, 5-pole
For the complete list of possible combinations please contact our technical department.
46
Page 3
2
FC series position switches
Technical data
Housing
Metal housing, powder-coated One threaded conduit entry: M20x1.5 (standard)
Protection degree: IP67 acc. to EN 60529
General data
Ambient temperature: -25°C … +80°C Max. actuation frequency: 3600 operating cycles/hour Mechanical endurance: 20 million operating cycles Mounting position: any Safety parameter B Mechanical interlock, not coded: type 1 acc. to EN ISO 14119 Tightening torques for installation: see page 211-222
with cable gland presenting same or higher protection degree
: 40,000,000 for NC contacts
10D
Main features
•Metal housing, one conduit entry
•Protection degree IP67
•3 contact blocks available
•26 actuators available
Cable cross section (flexible copper strands)
Contact blocks 33, 34: min. 1 x 0.34 mm
Contact block 3:
min. 1 x 0.5 mm
max. 2 x 1.5 mm
2
(1 x AWG 22)
2
(2 x AWG 16)
2
(1 x AWG 20)
max. 2 x 1.5 mm2 (2 x AWG 16)
•Versions with M12 connector
•Versions with gold-plated silver contacts
In compliance with standards:
IEC 60947-5-1, EN 60947-5-1, EN 60947-1, IEC 60204-1, EN 60204-1, EN ISO 14119, EN ISO 12100, IEC 60529, EN 60529, UL 508, CSA 22.2 No.14.
Approvals:
IEC 60947-5-1, UL 508, CSA 22.2 No.14, GB14048.5-2001.
Quality marks:
Compliance with the requirements of:
Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU.
Positive contact opening in conformity with standards:
IMQ approval: EG605
IEC 60947-5-1, EN 60947-5-1.
UL approval: E131787 CCC approval: 2007010305230000 EAC approval: RUC-IT.AД35.В.00454
Installation for safety applications:
Use only switches marked with the symbol
next to the product code. Always connect the safety circuit to the NC contacts (normally closed contacts: 11-12, 21-22 or 31-32) as required by EN ISO 14119, paragraph 5.4 for specific interlock applications and EN ISO 13849-2 tables D3 (well-tried components) and D.8 (fault exclusions) for safety applications in general. Actuate the switch at least up to the positive opening travel shown in the travel diagrams on page 214. Actuate the switch at least with the positive opening force, reported in brackets below each article, next to the actuating force value.
If not expressly indicated in this chapter, for correct installation and utilization of all articles see the instructions given on pages
211 to 222.
Electrical data Utilization category
Thermal current (Ith): 10 A Rated insulation voltage (U
Rated impulse withstand voltage (U
without
connector
Conditional short circuit current: 1000 A acc. to EN 60947-5-1
): 500 Vac 600 Vdc
i
): 6 kV
imp
400 Vac 500 Vdc
4 kV
(contact block 33, 34)
Protection against short circuits: type aM fuse 10 A 500 V
(contact blocks 33, 34)
Alternating current: AC15 (50÷60 Hz) Ue (V) 250 400 500 Ie (A) 6 4 1 Direct current: DC13 Ue (V) 24 125 250 Ie (A) 6 1.1 0.4
Pollution degree: 3
Alternating current: AC15 (50÷60 Hz) Ue (V) 24 120 250 Ie (A) 4 4 4 Direct current: DC13 Ue (V) 24 125 250 Ie (A) 4 1.1 0.4
General Catalogue Detection 2017-2018
47
Thermal current (I Rated insulation voltage (U
5-pole
Protection against short circuits: type gG fuse 4 A 500 V Pollution degree: 3
with M12 connector
): 4 A
th
): 250 Vac 300 Vdc
i
Page 4
Features approved by IMQ Features approved by UL
Rated insulation voltage (Ui): 500 Vac
(for contact blocks 33, 34)
Conventional free air thermal current
400 Vac
10 A (Ith): Protection against short circuits: type aM fuse 10 A 500 V Rated impulse withstand voltage (U
imp
): 6 kV
(for contact blocks 33, 34)
4 kV Protection degree of the housing: IP67 MV terminals (screw terminals) Pollution degree: 3 Utilization category: AC15 Operating voltage (Ue): 400 Vac (50 Hz) Operating current (Ie): 3 A Forms of the contact element: Zb, Y+Y
Positive opening of contacts on contact blocks 33, 34 In compliance with standards: EN 60947-1, EN 60947-5-1+ A1:2009, fundamental requirements of the Low Voltage Directive 2014/35/EU.
Please contact our technical department for the list of approved products.
Utilization category Q300 (69 VA, 125-250 Vdc) A600 (720 VA, 120-600 Vac) Housing features type 1, 4X, 12, 13 For all contact blocks except 2 and 3 use 60 or 75°C copper (Cu) conductors, rigid or flexible, wire size 12, 14 AWG. Tightening torque for terminal screws of 7.1 lb in (0.8 Nm). For contact blocks 2 and 3 use 60 or 75 °C copper (Cu) conductors, rigid or flexible, wire size 14 AWG. Tightening torque for terminal screws of 12 lb in (1.4 Nm).
In compliance with standard: UL 508, CSA 22.2 No.14
Please contact our technical department for the list of approved products.
Wiring diagram for M12 connectors
2
Contact block 3
1NC-1NO
1
2
3
M12 connector,
5-pole
Contacts Pin no. Contacts Pin no. Contacts Pin no.
NC 1- 2 NC 1- 2 NC 1- 2
NO 3-4 NO 3-4 NC 3-4
ground 5 ground 5 ground 5
Contact block33
1NC+1NO
1
4
2
5
3
M12 connector,
5-pole
Contact block34
2NC
1
4
2
5
3
M12 connector,
5-pole
4
5
General Catalogue Detection 2017-2018
48
Page 5
2
Contact type:
R
= snap action = slow action
L
FC series position switches
With stainless steel roller on request With stainless steel roller on request
25.7 7
20
10
17.6
45.5 7
Ø
14.5
5.3
44.7
45.5 7
5.8
Ø6 x200
5.3
5.8
14.5
41-53
41-53
46.1
45.5 7
187 max
14.5
5.3
45.5 7
42.1 20
7
14.5
5.3
Contact block
3 33 34
Max. speed
Actuating force
Travel diagrams
Contact block
3 33 34
Max. speed
Actuating force
Travel diagrams
R
L
L
R
L
L
FC 301-M2 FC 3301-M2 FC 3401-M2
page 213 - type 4
6 N (25 N
page 214 - group 1
22.1
45.5 7
FC 308-M2 FC 3308-M2 FC 3408-M2
page 213 - type 4
6 N (25 N
page 214 - group 1
30
40
14.5
1NO-1NC
1NO+1NC
2NC
33.4
FC 302-M2 FC 3302-M2 FC 3402-M2
30
40
page 213 - type 3
)
4 N (25 N
page 214 - group 2
With external rubber gasket
29.6
45.5 7
Ø
30
40
10
Ø
14.5
5.3
30
40
14.5
1NO-1NC
1NO+1NC
2NC
33.4
FC 310-M2 FC 3310-M2 FC 3410-M2
page 213 - type 4
)
7 N (25 N
page 214 - group 1
10
14.5
1NO-1NC
1NO+1NC
2NC
)
14.5
5.3
14.5
1NO-1NC
1NO+1NC
2NC
)
33.4
33.4
FC 304-M2 FC 3304-M2 FC 3404-M2
page 214 - group 1
29.8
45.5 7
FC 311-M2 FC 3311-M2 FC 3411-M2
page 213 - type 4
6 N (25 N
page 214 - group 1
30
40
0.5 m/s
0.17 Nm
10
Ø
30
40
1NO-1NC
1NO+1NC
2NC
5.3
1NO-1NC
1NO+1NC
2NC
)
14.5
14.5
14.5
33.4
33.4
30
40
FC 305-M2 FC 3305-M2 FC 3405-M2
page 213 - type 3
4 N (25 N
page 214 - group 2
With external rubber gasket
13
43.3
45.5 7
5.3
30
40
FC 315-M2 FC 3315-M2 FC 3415-M2
page 213 - type 2
7 N (25 N
page 214 - group 1
14.5
1NO-1NC
1NO+1NC
2NC
)
14.5
14.5
1NO-1NC
1NO+1NC
2NC
)
33.4
4
33.4
13
43.1
30
40
6 N (25 N
5.3
1NO-1NC
1NO+1NC
2NC
45.5 7
Contact block
R
3
L
33
L
34
Max. speed
Actuating force
Travel diagrams
Items with code on green background are stock items
Items with code on green background are stock items
FC 316-M2 FC 3316-M2 FC 3416-M2
page 213 - type 2
page 214 - group 1
4
14.5
14.5
33.4
)
49
Ball, Ø 8 mm, stainless steel
10
Ø
34.1
45.5 7
FC 318-M2 FC 3318-M2 FC 3418-M2
5.3
30
40
1NO-1NC
1NO+1NC
2NC
page 213 - type 4
6 N (25 N
page 214 - group 1
Accessories See page 197
Accessories See page 197
)
14.5
14.5
33.4
Ball, Ø 12.7 mm, stainless steel
41.1
45.5 7
FC 319-M2 FC 3319-M2 FC 3419-M2
5.3
30
40
1NO-1NC
1NO+1NC
2NC
page 213 - type 4
6 N (25 N
page 214 - group 1
The 2D and 3D files are available at www.pizzato.com
With external rubber gasket
55
16
Ø
14.5
14.5
33.4
115.1
12.2
45.5 7
30
40
FC 320-M2 FC 3320-M2 FC 3420-M2
1 m/s
)
0.07 Nm
page 214 - group 3
All values in the drawings are in mm
General Catalogue Detection 2017-2018
5.3
1NO-1NC
1NO+1NC
2NC
14.5
14.5
33.4
Page 6
2
48.1
48.1
34-131
Contact type:
R
= snap action = slow action
L
Contact block
3 33 34
Max. speed
Actuating force
Travel diagrams
With external rubber gasket With external rubber gasket
1.2
Ø
87
R
L
L
131.1
12.2
45.5 7
FC 321-M2 FC 3321-M2 FC 3421-M2
30
40
5.3
1NO-1NC
1NO+1NC
2NC
14.5
14.5
33.4
117
12.2
45.5 7
FC 325-M2 FC 3325-M2 FC 3425-M2
1 m/s
0.06 Nm
page 214 - group 3
Square rod, 3x3 mm Glass fibre rod
3x3x125
4.5
15
45.5 7
24
14.5
5.3
5515
123
45.5 7
7.5
Ø
5.3
30
40
1NO-1NC
1NO+1NC
2NC
1 m/s
0.1 Nm
page 214 - group 3
38.9
Ø7.3
24
14.5
5.3
14.5
14.5
59.9
33.4
Other rollers available. See page 52
5.3
36.7
24
14.5
14.5
33.4
1NO-1NC
1NO+1NC
2NC
20
55
15
45.5 7
30
40
FC 331-M2 FC 3331-M2 FC 3431-M2
page 213 - type 1
0.09 Nm (0.25 Nm page 214 - group 4
Other rollers available. See page 52
20
Ø
49 - 108
15
45.5 7
24
14.5
5.3
55.1
7
)
51.1
40.8
Round rod, Ø 3 mm, stainless steel
Ø3 x125
4.5
34-131
15
45.5 7
30
FC 332-M2 FC 3332-M2 FC 3432-M2
24
5.3
40
1NO-1NC
1NO+1NC
2NC
1.5 m/s
0.09 Nm
page 214 - group 4
34 - 204
7
45.5 7
Ø6x200
10
24
5.3
14.5
14.5
14.5
33.4
47.4
1NO-1NC
1NO+1NC
2NC
24
5.3
1NO-1NC
1NO+1NC
2NC
14.5
15.9
7
14.5
14.5
33.4
55.2
33.4
)
30
Contact block
R
L
L
R
L
L
FC 333-M2 FC 3333-M2 FC 3433-M2
55
FC 351-M2 FC 3351-M2 FC 3451-M2
3 33 34
Max. speed
Actuating force
Travel diagrams
Contact block
3 33 34
Max. speed
Actuating force
Travel diagrams
(1)
Positive opening only with actuator set to max. See page 51.
Items with code on green background are stock items
Items with code on green background are stock items
40
1.5 m/s
0.09 Nm
page 214 - group 4
Other rollers available. See page 52 Other rollers available. See page 52 Other rollers available. See page 52
20
15
45.5 7
30
40
page 213 - type 1
0.05 Nm (0.25 Nm page 214 - group 4
30
40
FC 334-M2 FC 3334-M2 FC 3434-M2
1 m/s
0.09 Nm
page 214 - group 4
20
63.6
15
45.5 7
30
40
FC 352-M2 FC 3352-M2 FC 3452-M2
page 213 - type 1
0.05 Nm (0.25 Nm page 214 - group 4
14.5
33.4
1NO-1NC
1NO+1NC
2NC
40.7
30.4
24
14.5
5.3
14.5
33.4
1NO-1NC
1NO+1NC
2NC
)
Accessories See page 197
Accessories See page 197
30
40
FC 335-M2 FC 3335-M2 FC 3435-M2
page 213 - type 1
0.09 Nm (0.25 Nm page 214 - group 4
Porcelain roller
Ø9
95.3
7
15
45.5 7
FC 353-E11M2 FC 3353-E11M2V9 FC 3453-E11M2V9
0.02 Nm (0.25 Nm page 214 - group 5
30
40
0.5 m/s
(1)
(1)
14.5
33.4
1NO-1NC
1NO+1NC
2NC
30
40
FC 336-M2 FC 3336-M2 FC 3436-M2
14.5
1NO-1NC
1NO+1NC
2NC
1.5 m/s
)
0.09 Nm
page 214 - group 4
20
42.5
28.5
56.5
49 - 108
24
14.5
5.3
14.5
33.4
1NO-1NC
1NO+1NC
2NC
15
45.5 7
30
FC 356-M2 FC 3356-M2 FC 3456-M2
24
14.5
5.3
40
14.5
1NO-1NC
1NO+1NC
2NC
page 213 - type 1
)
0.09 Nm (0.25 Nm page 214 - group 4
All values in the drawings are in mm
The 2D and 3D files are available at www.pizzato.com
33.4
33.4
40.8
51.1
7
)
General Catalogue Detection 2017-2018
50
Page 7
2
FC series position switches
)
Rope switch for signallingOther rollers available. See page 52
7
15.325.1
45.5 7
30
40
FC 376-M2 FC 3376-M2 FC 3476-M2
0.5 m/s
initial 20 N - final 40 N
page 214 - group 6
14.5
14.5
5.3
14.5
1NO-1NC
1NO+1NC
2NC
33.4
Contact type:
R
= snap action = slow action
L
Contact block
R
3
L
33
L
34
Max. speed
Actuating force
Travel diagrams
All values in the drawings are in mm
20
58
15
45.5 7
30
40
FC 357-M2 FC 3357-M2 FC 3457-M2
page 213 - type 1
0.09 Nm (0.25 Nm page 214 - group 4
5.3
32.5
24
14.5
14.5
33.4
1NO-1NC
1NO+1NC
2NC
62.8
Position switches with swivelling lever without actuator
Regular head Compact head
28
M5
15
45.5 7
41.5
24
14.5
5.3
28
15
45.5 7
31.1
M5
24
14.5
5.3
All values in the drawings are in mm
IMPORTANT For safety applications: join only switches and actuators
marked with symbol next to the product code. For more information about safety applications see details on page 211.
14.5
33.4
1NO-1NC
1NO+1NC
2NC
)
30
40
FC 358-M2 FC 3358-M2 FC 3458-M2
0.05 Nm (0.25 Nm page 214 - group 4
1NO-1NC
1NO+1NC
2NC
Contact block
3 33 34
Actuating force
Travel diagrams
R
L
L
30
40
FC 338-M2 FC 3338-M2 FC 3438-M2
0.09 Nm (0.25 Nm page 214 - group 4
Separate actuators
IMPORTANT: These separate actuators can be used only with items of the FD, FP, FL, FC series.
Technopolymer roller
Ø 20 mm
13.54.9
20
40
M 5
VF L31
Technopolymer roller
Ø 20 mm
15
20
40
7
7
24
Adjustable round rod
Ø 3x125 mm
Ø 3x125
4.5
5
M 5
(3)
VF L32
Technopolymer roller
Ø 20 mm
20
10491
19 - 116
7
Adjustable square rod,
3x3x125 mm
3x3x125
4.5
5
M 5
(3)
VF L33
Porcelain roller
11.5
2.5
Ø 9
57
80
19 - 116
14.5
33.4
)
Flexible rod with pointed end
55
106
M 5
2.5
VF L34
Adjustable safety actuator with
technopolymer roller
20
1
34 - 93
M 5
All values in the drawings are in mm
Adjustable actuator with
technopolymer roller
Ø 20 mm
1
M 5
10
(1) (3)
2011
20
34 - 93
11.5
VF L35
Technopolymer roller
10
20
7
43
Adjustable glass fibre rod
Ø6x200
10
7
7
6.5
VF L36
19 - 189
M 5
(3)
M 5
M 5
VF L51 VF L52 VF L53
Items with code on green background are stock items
Items with code on green background are stock items
51
M 5
(2)
Accessories See page 197
Accessories See page 197
VF L56
M 5
(3)
VF L57
The 2D and 3D files are available at www.pizzato.com
General Catalogue Detection 2017-2018
Page 8
2
43.5 - 101
55
58.5 - 108
58
Special separate actuators
IMPORTANT: These separate actuators can be used only with items of the FD, FP, FL, FC series.
Stainless steel rollers, Ø 20 mm
35
1
M 5
0.8 9.5
M 5
3
40
M 5
10
15
24
7
(1) (3)
7
(1) (3)
12
10
20
40
7
M 5
VF L51-R24 VF L52-R24 VF L56-R24
24
35
47.5
VF L51-R25
40
50
M 5
7
M 5
(4)
26
10
20
13.5
5
20
40
M 5
34 - 93
7
VF L31-R24 VF L35-R24
Technopolymer rollers, Ø 35 mm
13.5
35
47.5
VF L31-R25
7
M 5
(4)
VF L35-R25
Rubber rollers, Ø 40 mm
16
10
40
52.5 - 103.5
50
M 5
20
1
35
10491
M 5
0.8 9.5
M 5
7
34 - 93
M 5
0.8
35
7
41.3 - 101.3
20
56.1
VF L52-R25 VF L56-R25
3
12
3
40
59
10
50 - 103.8
M 5
40
All values in the drawings are in mm
10
20
7
9.5
M 5
12
M 5
43
(3)
(3)
VF L57-R24
7
35
50.5
VF L57-R25
10
40
53
M 5
M 5
2011
7
19.510.8 7
M 5
22
10
VF L31-R5
(4)
VF L35-R5
(1) (3)
VF L51-R5
(4)
VF L52-R5 VF L56-R5
(3)
Rubber rollers, Ø 50 mm
16
50
M 5
VF L31-R26
10
(4)
VF L35-R26
12
3
10
50
55
M 5
(1) (3)
VF L51-R26
50
M 5
26
10
64
(4)
VF L52-R26
12
50
10
58.8 - 108
M 5
(4)
VF L56-R26
12
3
50
M 5
(3)
Protruding rubber rollers, Ø 50 mm
50
58.5 - 108
M 5
VF L35-R27
(1)
Actuator VF L35 can only be used in safety applications if adjusted to its max. length, as shown in the figure to the right. If an adjustable
­lever is required for safety applications, use the VF L56 adjustable safety lever.
(2)
-
ThepositionswitchobtainedbyassemblingswitchFC•58‑M2(e.g.FC358‑M2,FC3358‑M2…)withactuatorVFL53willnotpresentthe
sametraveldiagramsandactuatingforcesasswitchFC•53‑E11M2(e.g.FC353‑E11M2,FC3353‑E11M2V9…).
(3)
-
IfinstalledwithswitchFC•58‑M2(e.g.FC358‑M2,FC3358‑M2…) theactuatormayhitthe housingoftheswitchuponactuation.This
possible interference depends on the fixing position of actuator and switch head.
(4)
-
The actuator cannot be rotated to the inside because it will hit the switch head upon actuation.
10
(1) (3)
58.8 - 108
50
VF L56-R27
20 - 35
11.4 - 26.4
Accessories See page 197 The 2D and 3D files are available at www.pizzato.com
General Catalogue Detection 2017-2018
20 - 3511.4 - 26.4
10
M 5
(3)
10
VF L57-R26
VF L57-R5
22
50
M 5
93
(4)
10
(4)
52