Pitco PFC570-HB Service Manual

Counter Model Electric Fryer System
Perfect Fry PFC570-HB
Perfect Fry Company 39 Sheep Davis Road Pembroke, NH 03275-3705 Phone: 603-225-6684 Fax: 603-225-8497
www.perfectfry.com
IMPORTANT FOR FUTURE REFERENCE
Please complete this information and retain this manual for the life of the equipment.
Model # ______________________________________
Serial # ______________________________________
Date Purchased ________________________________
Installation & Operation Manual
PFC570-HB
CONTENTS
WARRANTY 2
INTRODUCTION 3
SAFETY 4
APPROVALS 5
PARTS IDENTIFICATION/FUNCTION AND EXPLODED VIEW 6
EQUIPMENT SET-UP AND CLOSE PROCEDURES 7
OPERATION AND CONTROL 18
TROUBLESHOOTING 29
PERFECT FRY FIRE SUPPRESSION SYSTEM 32
WIRING DIAGRAM 35
L20-435 R0 (5/2016)
WARRANTY
McDonald's ORIGINAL STANDARD EQUIPMENT LIMITED WARRANTY
Perfect Fry warrants to the original purchaser of its commercial cooking appliances and related equipment that said appliances and related equipment will be free from defects in material and workmanship under normal use for a period of two (2) years from the date of installation, with appropriate documentation, to a maximum of twenty-eight (28) months from the date of manufacture, subject to the following additions, exceptions, exclusions and limitations.
This warranty is limited to the repair or replacement at the Company’s option, without charge, of any part found to be defective within the warranty period and reasonable expenses incurred for freight and material for the installation of such part; in addition, the Company’s obligation shall be limited to reimbursement for normal labor on such parts. Perfect Fry, Inc. agrees to pay the Authorized Service and Parts Distributor, for any labor and material required to repair or replace, at the Company’s option, any part which may fail due to defects in material or workmanship during the above general warranty period.
How to Keep Your Warranty in Force
Make sure any shipping damages are reported immediately. Damages of this nature are the responsibility of the carrier and must be reported by the receiver.
Install the appliance properly. This is the responsibility of the installer and the procedures are outlined in the manual.
Do not install the appliance in a home or residence.
Maintain the appliance properly. This is the responsibility of the purchaser of the appliance and the procedures are outlined in the manual.
Replace the air lter at regular intervals to prevent lter saturation. Failure to do so could result in a non-warranty main fan failure due to grease build up.
Adjustments, such as calibration, leveling, tightening of fasteners or plumbing or electrical connections normally associated with initial installation are outlined in the manual and are not covered under warranty.
Damages as a result of re, ood or other acts of God are not covered under this warranty.
Use the appliance for what it is intended. If the appliance is used for a purpose other than for which it was intended or designed, resulting damages are not covered under the warranty.
Make sure that the appliance has the correct voltage. If a failure is due to incorrect or erratic voltage, these damages are not covered under the warranty
Do not materially alter or modify the appliance.
Do not obliterate, remove or alter the serial number rating plate.
Use only Genuine OEM parts from Perfect Fry or its Authorized Parts and Service Distributors. Repairs are not covered by the warranty if
non-OEM parts or non-Authorized Parts and Service Distributors are used.
Failures that are not attributable to a defect in materials or workmanship are not covered.
This warranty specically excludes parts which wear or would be replaced under normal usage, including, but not limited to, electric lamps, fuses, interior or exterior nishes, lters and gaskets.
Charges for mileage over one hundred (100) miles and travel time over two (2) hours from the Authorized Service and Parts Distributor are not covered
under this warranty. Extended mileage charges are the responsibility of the individual or rm requesting these services.
If any oral statements have been made regarding the appliance, these statements do not constitute warranties and are not part of the contract of sale.
This limited warranty constitutes the complete, nal and exclusive statement with regard to warranties. THIS LIMITED WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN, ORAL OR IMPLIED, INCLUDING, BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR WARRANTY AGAINST LATENT DEFECTS.
In the event of a warranty or other claim, the sole obligation of Perfect Fry will be limited to the repair or replacement, at the Company’s discretion, of the appliance or the component part. This repair or replacement will be at the expense of Perfect Fry except as limited by this warranty statement. Any repair or replacement under this warranty does not constitute an extension in time to the original warranty. Parts covered under this warranty will be repaired or replaced, at the Company’s discretion, with new or functionally operative parts. The liability of Perfect Fry on any claim of any kind, including claims based on warranty, express or implied contract, negligence, strict liability or any other legal theories will be limited to the
repair or replacement of the appliance. This liability will not include, and the purchaser specically renounces any right to recover special, incidental, consequential or other damages of any kind, including, but not limited to, injuries to persons, damage to property, loss of prots or anticipated loss of
the use of this appliance.
General Warranty
What is covered
Limits to the Warranty
Limitations of Liability
If any provision of this warranty is unenforceable under the law of any jurisdiction, that provision only will be inapplicable there, and the remainder of the warranty will remain unaffected. The maximum exclusion or limitation allowed by law will be substituted for the unenforceable provision.
How to Obtain Warranty Service
Direct your claim to the Perfect Fry Authorized Service and Parts Distributor, http://www.perfectfry.com closest to you giving complete model and serial numbers, voltage, and description of the problem. Proof of the date of installation and/or the sales slip may also be required. If there are questions
about this procedure, write the National Service Manager, Perfect Fry, P. O. Box 501, Concord, NH. 03302-0501. USA
This warranty gives you certain specic legal rights; you may have other rights which vary from state to state.
2
In order to activate please contact Perfect Fry Company, to register your warranty by:
Registering online anytime at www.perfectfry.com
or
Call 1-603-225-6684 (Mon - Fri 8:00-5:00 EST)
SEE THIS LCD DO THIS GET THIS LCD
FRYER ACTIVATION
THANK YOU FOR
PURCHASING A PERFECT
FRYER SN# XXXXX
GO ONLINE OR CALL
ENTER WARRANTY CODE
AND PRESS START

For temporary access, enter 123456 then press .
INTRODUCTION
Now that you have registered and activated your fryer;
Take comfort in knowing that the management and staff at Perfect Fry Company are ded­icated to ensure that you, the owner and operator of a Perfect Fryer, receive a top quality product that is thoroughly inspected and tested prior to shipment.
Take comfort in knowing that our local Authorized Service network is committed to supply­ing your service and warranty needs. Each Authorized Service and Parts Provider (ASAP) has dedicated service staff that is able to answer any questions you may have regarding the operation of your Perfect Fryer. We also have an online knowledgebase available 24/7/365 at www.perfectfry.com with many great tips and solutions.
1. Enter your warranty activation code
2. Press
3. Your Perfect Fryer is now perma­nently activated.
Temporary access is valid for 90 days.
HEATING PRESET
70
HASHBROWNS
°F
3
SAFETY
It is the owner’s responsibility to:
Insure the Perfect Fry PFC is properly maintained.
Allow only properly trained personnel to operate, clean and maintain a Perfect Fry PFC.
Contact local authorities having jurisdiction to insure that the installation conforms to all local
re, building and health regulations.
Schedule and maintain documentation that the appropriate inspection and maintenance of the PFS Automatic Extinguisher has been completed.
Insure that the model ready for installation matches the supply voltage.
Insure that the main power supply is disconnected before the Perfect Fry PFC is serviced.
Insure that all safety devices are intact.
Insure that a proper surface is provided for the Perfect Fry PFC to sit on.
Insure that proper clearances are kept.
Operate and store the Perfect Fry PFC above 32°F (0°C).
Return the Perfect Fry PFC for recycling when it reaches end of life.
SAFETY FIRST
LIFTING & MOVING:
Your Perfect Fry PFC’s gross shipping weight is 100 lb. (45 kg). Net weight = 80 lb. (36 kg).
DEEP FRYING:
Cooking oil is very hot, 359ºF (182ºC). Hot oil can cause severe burns. DO NOT TOUCH THE COOKING OIL UNLESS YOU ARE SURE IT HAS COOLED.
HEATER MODULE:
DO NOT DROP
DO NOT IMMERSE IN WATER
CLEANING:
Before cleaning fryer or removing oil, let fryer cool to 122ºF (50ºC). DO NOT TOUCH HEATER MODULE, VAT OR OIL UNLESS YOU ARE SURE IT HAS COOLED.
COOKING OIL MAINTENANCE:
For sanitation and safety, we recommend that the cooking oil is replaced when it no longer meets
quality requirements. Use a McDonald’s approved deep-fryer cooking oil. OLD OIL HAS A REDUCED FLASH POINT. OLD OIL AND OVER-WET FOOD ARE PRONE TO SURGE BOILING.
SERVICING:
DISCONNECT THE POWER SOURCE BEFORE SERVICING THE FRYER. There is no need to unplug your PERFECT FRYER for normal cleaning or maintenance.
STORAGE:
Do not store your Perfect Fry PFC below 0°C (32°F)
Intended for indoor use only
4
APPROVALS
REGULATIONS
Installation of your Perfect Fry PFC must conform to all local re and health regulations and building codes. The installation use and maintenance is to be in accordance with the Standard for Ventilation
Control and Fire Protection of Commercial Cooking Operations, NFPA 96 - 2004.
The table below describes the standards that your Perfect Fry PFC has been tested to and the corresponding listing marks.
STANDARD DESCRIPTION LISTING MARK
UL 197
UL710B
CSA 22.2 No. 109-M1981
NSF 4 Commercial Cooking, Rethermalization, and Powered Hot Food Holding
Commercial electric cooking appliances. Commercial electric cooking appliances with recirculating systems.
UL 197 & UL 197 SB supplement also reference the following
standards which your PERFECT FRYER meets applicable parts thereof:
UL 1046: Grease Filters for Exhaust Ducts.
UL 300: Fire Testing of Fire Extinguishing Systems for Protection of Restaurant Cooking Areas.
UL 900: Standard for Air Filter Units
NFPA 17A: Wet Chemical Extinguishing Systems.
NFPA 96: Standard for Ventilation Control and Fire Protection of
Commercial Cooking Operations.
EPA 202: Determination of Condensible Particulate Emissions for Stationary Sources.
Commercial Cooking Appliances forming part of Canadian Electrical Code, Part 2 Safety Standards for Electrical Equipment.
and Transport Equipment.
5
PARTS IDENTIFICATION/FUNCTION AND EXPLODED VIEW
7
4
5 6
3
2
21
1
19
18
22
20
16
9
10
14
15
8
11
13
12
17
Item Description Part No. Item Description Part No.
1 Kit, Assembly Front Panel 3HT716-C 18 Assembly, Basket Lift 3HT740-C
2
19 Assembly, Element 5.7kW 240V 8ET900-C
Kit, Odor and Passive Filter 2FK001
3 20 Assembly, Female Connector 3CT765-C
4 Assembly, Bracket Cage 6ST730-C 21 Plug, Cover Female Connector 6CT100
5 Module, Airow 2HT723-C 22 Gasket, Molded Silicone 6FR021
6 Kit, Main Fan 2DT951-C NS Kit, Door Springs PFC 2DT957-C
7 Fire Damper 6HT588 NS Assembly, Air Filter Switch 3HT724-C
8 Assembly, Grease Filter 3HT727 NS Switch, Grease Filter/Door 6HT566
9 Assembly, Grease Filter Tray 6ST728-C NS Assembly, Filter Drain Hose B6698901-C
10 Assembly, Elec. Box Module 2WS805-C NS Assembly, Remote Buzzer HB B5311801-C
11 Access Control Panel 6ST732-C NS Kit, Control Fan 12VDC 6DT952-C
12 Assembly, Firemaster System 2GT001-C NS Feet, Adhesive (4 per PFC) 6HV026
13 Spring, Extension 40lbs 6GT67401 NS Kit, Fusible Link 250°F 6FP00701-C
14 Assembly, PFC Basket Motor 2HT689-C NS Switch, Front Panel Proximity 6HT567
15 Assembly, Spill Tray 6ST734-C NS Kit, Firemaster Wet Chemical 2DT943-C
16 Kit, Oil Vat PFC w/ Valve 2DT018-C NS Latch, Vice Wing Non-Locking 6DA100
17 Assembly, Drip Tray PFC 6ST105-C NS Hinge, Door Lift and Turn 6HT503
6
EQUIPMENT SET-UP AND CLOSE PROCEDURES
INSTALLATION
Electrical Power Supply
Your Perfect Fry PFC must be connected to a dedicated electrical circuit that meets your fryer’s requirements (see table below).
Improper installation may damage the fryer and void you warranty.
If your Perfect Fry PFC’s plug does not t your wall outlet receptacle, have an electrician install the appropriate NEMA receptacle within 4 feet of the fryer.
See the manufacturer’s label on your Perfect Fry PFC for the electrical Model No. PFC570, then check off your Model Number.
PERFECT
FRY MODEL
VOLTAGE AMPS
Put a check mark  in the box beside the Model Number of your Perfect Fry PFC.
PFC570
PFC570
240 24.0 30 5700
208 20.6 30 4281
All models are single phase, 50/60 hertz.
CIRCUIT
AMPS
WATTAGE
NEMA
NUMBER
L6-30P
6-30P
Pin & Sleeve
30A, 250V, 2 Pole
NEMA
RECEPTACLE
L6-30R
6-30R
IEC 60309
30A, 250V, 2P
7
EQUIPMENT SET-UP AND CLOSE PROCEDURES
INSTALLATION (Continued)
Prepare Counter-top Area
16"
40.62
Required Clearances
1” on sides
2” on rear
0” on top
17"
43.18
23"
58.42
Unpack
1. Cut straps on shipping box.
2. Remove box top and sleeve.
3. Remove outer plastic wrapping and keep box along with foam corners and sides until installation of your Perfect Fry PFC is complete.
8
EQUIPMENT SET-UP AND CLOSE PROCEDURES
INSTALLATION (Continued)
Unpack
Your Perfect Fry PFC weighs 80lb (36kg). Lift it carefully with additional help, as needed and
place it in its nal location.
4. Lift your Perfect Fry PFC onto counter top.
5. Remove all foam stufng and parts.
6. Put check mark in box once the part is removed.
         
1 Air Filter Cage 2 Air Filtration Odor Filter 3 Air Filtration Passive Filter 4 Grease Filter 5 Grease Filter Tray 6 Basket Lift Assembly 7 Heater Module 8 Drip Tray 9 Oil Vat
10 Oil Spill Tray
11 Drain Hose
12 Rear Plug Cover
7
1
2
3
4
5
9
6
10
8
9
EQUIPMENT SET-UP AND CLOSE PROCEDURES
INSTALLATION (Continued)
Unpack
11
7. Ensure that blow-off caps on re extinguisher nozzles are kept in place.
8. When removing item 12, please relocate to upper holding location designated Rear Plug Cover Holder in the diagram below.
REAR PLUG COVER HOLDER
12
BLOW OFF CAPS
12
10
EQUIPMENT SET-UP AND CLOSE PROCEDURES
ASSEMBLY
1. Clean parts and inside of cabinet (all except air ltration cartridges). a. Wash in warm soapy water. b. Rinse with hot water
The heater box must NOT be immersed in water, or any other liquid.
2. Plug in fryer and press Note: LCD will display what is missing and will beep twice when part is installed
3. Install grease lter into grease lter tray.
HEATER BOX GREASE FILTER
AIR FILTER REPLACEMENT
FRONT PANEL
SYSTEM ERROR
PLEASE CHECK/CHANGE
4. Install grease lter/grease lter tray into lter compartment
by sliding along rails and towards the rear of unit.
5. Fit air lter cage over air lter cartridges as shown. Ensure arrows are pointed upwards on both lters and write installation date on odor ltration cartridge in space
provided.
11
Loading...
+ 25 hidden pages