To Turn Control ON: ___________________________________________________________3
To Turn Control OFF: __________________________________________________________3
To Activate timers 1-4: _________________________________________________________3
To Activate timers 5-8: _________________________________________________________3
To Cancel a Cook: _____________________________________________________________3
To Enter Boil Mode:____________________________________________________________3
To Enter Simmer Mode: ________________________________________________________3
To Unlock: ___________________________________________________________________4
To Change Simmer Temperature: ________________________________________________4
To Change Timers 1-4: _________________________________________________________4
To Change Timers 5-8: _________________________________________________________4
To Exit Programming: __________________________________________________________5
Other Displays:___________________________________________________________5
Low Vat Temperature __________________________________________________________5
Drain Valve Open______________________________________________________________5
Equipment Fault Displays_______________________________________________________5
To Change Port Address________________________________________________________5
To View Software Revision______________________________________________________5
L20-269 Rev 2
Pg. 2 of 8
Page 3
Operation:
Pitco Compact Pasta Control
60143701
Warning
Make certain cook tank is filled with water before turning this appliance ON.
To Turn Control ON:
Press the
button. Display will show , , or .
To Turn Control OFF:
Press and hold the
button. Display will show .
To Activate timers 1-4:
Press
, , or .
To Activate timers 5-8:
Press
then , , or .
Note: Multiple timers may run together, but only one timer for a key.
To Cancel a Cook:
Press and hold the timer key until the cook indicator or light above the key is off.
To Enter Boil Mode: Press
until is displayed.
To Enter Simmer Mode: Press
.
until is displayed.
L20-269 Rev 2
Pg. 3 of 8
Page 4
Pitco Compact Pasta Control
60143701
Programming:
To enter the programming menu, press and hold key for 3 seconds.
The display will show
for program entry or for locked entry.
If control is displaying [Pr--] skip the next step.
To Unlock:
With display showing
, press the key once followed by key. Display will show
. Control is now unlocked ready for programming.
To Change Simmer Temperature:
With display showing
. Press the key, display will show . Press the
to display the current simmer temperature setting as , or . To change this
setting, use the
Display will show
key or key to adjust temperature, then press the key to save value.
. Continue to the next step.
To Change Timers 1-4:
With display showing
, press the key once. Display will show .
Press the timer key needing adjustment. The indictor above that key will illuminate, and the display will
show the current timer setting, for example
time. Press the
key to save value. Display returns to
. Use the key or key to adjust
keys in this group.
When all keys in this group are set, press the
key to continue.
To Change Timers 5-8:
Display will shows
. Press the timer key needing adjustment. The indictor above that key
will illuminate, and the display will show the current timer setting, for example
key or key to adjust time. Press the key to save value. Display returns to
above. Repeat for other timer keys in this group. When all keys in this group are set, press
to continue. Display will show .
above. Repeat for other timer
. Use the
L20-269 Rev 2
Pg. 4 of 8
Page 5
To Exit Programming:
Pitco Compact Pasta Control
60143701
Press and hold the
key to exit. Display will show or, or,.
Other Displays:
Low Vat Temperature
When tank temperature is below 70°F (21°C), the display will show as
blanks. This is normal for cold start-ups. Heat Demand indicator is located
between the first and second digits of display.
Drain Valve Open
When drain valve is detected open,
normal operations are suspended. The
display will show Drain-Turn-Off message
until reset. To reset, CLOSE the drain
valve, turn the control OFF. Allow the appliance to cool. When the tank is refilled control may be turned
ON. Note: some applications do not use the drain valve input.
Equipment Fault Displays
Probe Faults
If temperature probe faults are detected, the display will show [Prob] and sound the
alarm. All timer functions are disabled, and heat control shut off. To reset, turn
control Off then On.
High Temperature Alarm
This display shows when the control detects a temeprature above the alarm limit of
230°F (110°C). A continuous alarm will sound. To reset, turn control Off then On.
To Change Port Address
With display showing
press
Use
and simultaneously for 2 seconds. Display show the current address setting.
and to change address. Press to save selection and return to
(from section”To Enter Level 2 Programming”),
display. This address setting has no effect on operations of the controller, and, is only meaningful when
control is networked for data collection with other controls. In this case, controls must have different port
addresses. Press and hold the
to exit.
To View Software Revision
While display is showing one of the normal operator displays ([bOIL], [Sim], or [__°F]), press and hold
and the simultaneously for 2 seconds. Display will show a rotating display, 4 digits each,