This service manual is intended for qualified service technicians ; it is not meant for the casual do-it-yourselfer. Qualified technicians
have the necessary test equipment and tools, and have been trained to properly and safely repair complex products such as those
covered by this manual.
Improperly performed repairs can adversely affect the safety and reliability of the product and may void the warranty. If you a re not
qualified to perform the repair of this product properly and safely, you should not risk trying to do so and refer the repair to a
qualified service technician.
WARNING
This product contains lead in solder and certain electrical parts contain chemicals which are known to the state of California to cause cancer, birth
defects or other reproductive harm.
TEL 13942296513 QQ 376315150 892498299
NOTICE
(FOR CANADIAN MODEL ONLY)
Fuse symbols (fast operating fuse) and/or (slow operating fuse) on PCB indicate that replacement parts must be of identical
designation.
REMARQUE
(POUR MODÈLE CANADIEN SEULEMENT)
Les symboles de fusible (fusible de type rapide) et/ou (fusible de type lent) sur CCI indiquent que les pièces de remplacement
doivent avoir la même désignation.
(FOR USA MODEL ONLY)
3
7
6
3
1
5
1
5
0
4
2
9
8
Health & Safety Code Section 25249.6 – Proposition 65
9
8
2
9
9
TEL 13942296513 QQ 376315150 892498299
1. SAFETY PRECAUTIONS
TEL
The following check should be performed for the
continued protection of the customer and service technician.
LEAKAGE CURRENT CHECK
Measure leakage current to a known earth ground (water pipe,
conduit, etc.) by connecting a leakage current tester such as Simpson
Model 229-2 or equivalent between the earth ground and all exposed
metal parts of the appliance (input/output terminals, screwheads,
metal overlays, control shaft, etc.). Plug the AC line cord of the
appliance directly into a 120V AC 60Hz outlet and turn the AC power
switch on. Any current measured must not exceed 0.5mA.
13942296513
Device
under
test
Test all
exposed metal
surfaces
Also test with
plug reversed
(Using AC adapter
plug as required)
AC Leakage Test
Leakage
current
tester
+
Reading should
not be above
0.5mA
-
Earth
ground
ANY MEASUREMENTS NOT WITHIN THE LIMITS OUTLINED
ABOVE ARE INDICA TIVE OF A POTENTIAL SHOCK HAZARD
Q
Q
AND MUST BE CORRECTED BEFORE RETURNING THE
APPLIANCE TO THE CUSTOMER.
2. PRODUCT SAFETY NOTICE
Many electrical and mechanical parts in the appliance
have special safety related characteristics. These are often
not evident from visual inspection nor the protection afforded
by them necessarily can be obtained by using replacement
components rated for voltage, wattage, etc. Replacement parts
which have these special safety characteristics are identified
in this Service Manual.
Electrical components having such features are identified
by marking with a on the schematics and on the parts list in
this Service Manual. The use of a substitute replacement
component which does not have the same safety characteristics
as the PIONEER recommended replacement one, shown in
the parts list in this Service Manual, may create shock, fire, or
other hazards.
Product Safety is continuously under review and new
instructions are issued from time to time. For the latest
information, always consult the current PIONEER Service
Manual. A subscription to, or additional copies of, PIONEER
Service Manual may be obtained at a nominal charge from
PIONEER.
3
7
6
3
1
5
1
5
0
8
9
2
4
9
8
2
9
9
w
2
w
w
.
xia
o
y
u
1
6
3
.
c
o
m
S-FCRW220
S-FCRW720
Q
TEL 13942296513 QQ 376315150 892498299
2. DISASSEMBLY
Q
2.1 SUBWOOFER
¶ POWER AMP SECTION
¶
¶
3. PACKING EXPLODED VIEWS AND PARTS LIST
NOTES:
¶ Parts marked by "NSP" are generally unavailable because they are not in our Master Spare Parts List.
¶ The
of identical designation.
¶ Parts marked by " " are not always kept in stock. Their delivery time may be longer than they may be unavailable.
7
3
Remove the 8 screws from the power amplifier.
Remove the connector lead, etc.
FRONT PANEL
The front panel is attached to the cabinet by its bosses
applied with adhesive.
To detach it, pry it open by inserting a flat blade
screwdriver into bottom slot between the cabinet and front
panel.
SPEAKER
To detach first remove the front panel, then remove the
4 external screws.
mark found on some component parts indicates the importance of the safety factor of the part. Therefor e, when replacing, be sure to use parts
6
3
1
5
1
5
0
2.2 SATELLITE
4
2
9
8
¶¶
¶
METAL GRILLE
¶¶
The metal grill is attached to the cabinet by butyl rubber.
To detach it, pull it away by a hook.
9
8
2
9
9
TEL 13942296513 QQ 376315150 892498299
TEL
13942296513
3.1 PACKING
Parts List
MarkNo. DescriptionParts No.
1Instruction Manual (220)279083
2instruction Manual (720)279503
3RCA Pin Cable CEA Purple278397
4Speaker Wire for FR CEA Red 5M278406
5Speaker Wire for FL CEA White 5M27841 1
6Speaker Wire for C CEA Green 4M278426
7Speaker Wire for RR CEA Grey 8M278431
8Speaker Wire for RL CEA Blue 8M278446
9Speaker Wire for RL CEA Brown 10M279494
10Rubber Foot (A) Set (220)277963
11Rubber Foot (A) Set (720)278139
12Rubber Foot (B) Set277978
13Styro Pad Top277527
14Styro Pad Mid279058
15Styro Pad Bottom279063
16Packing Case (220-K/KUXC)279241
17Packing Case (220-K/KCXC)279969
18Packing Case (220-S/KUXC)279043
19Packing Case (220-S/KCXC)279474
20Packing Case (720-S/KUXC)279390
21Speaker Wire + Foot Assy (220)279221
22Speaker Wire + Foot Assy (720)279489