Pioneer GR-209 Service manual

209
STANDBY/ON
GRAPHIC EQUALIZER
THIS MANUAL IS APPLICABLE TO THE FOLLOWING MODEL(S) AND TYPE(S).
Type
MYXCN1 AC220– 230V SDXCN1 AC110/120–127/220/240V With the voltage selector
Model
GR-209
Power Requirement Remarks
ORDER NO.
RRV2147
CONTENTS
1. SAFETY INFORMATION
2. EXPLODED VIEWS AND PARTS LIST
3. SCHEMATIC DIAGRAM
4. PCB CONNECTION DIAGRAM
5. PCB PARTS LIST
6. ADJUSTMENT
7. GENERAL INFORMATION
7.1 IC
8. PANEL FACILITIES AND SPECIFICATIONS
PIONEER ELECTRONIC CORPORATION 4-1, Meguro 1-Chome, Meguro-ku, Tokyo 153-8654, Japan
PIONEER ELECTRONICS SERVICE, INC. P.O. Box 1760, Long Beach, CA 90801-1760, U.S.A. PIONEER ELECTRONIC (EUROPE) N.V. Haven 1087, Keetberglaan 1, 9120 Melsele, Belgium PIONEER ELECTRONICS ASIACENTRE PTE. LTD. 253 Alexandra Road, #04-01, Singapore 159936
c
PIONEER ELECTRONIC CORPORATION 1999
..................................................................
...............................................
....................................................
......................................
................
.......................................
............................
................................
....
2 3 6
8 10 10 11 11 13
T – ZZR MAY 1999 Printed in Japan
GR-209
1. SAFETY INFORMATION
This service manual is intended for qualified service technicians ; it is not meant for the casual do-it­yourselfer. Qualified technicians have the necessary test equipment and tools, and have been trained to properly and safely repair complex products such as those covered by this manual. Improperly performed repairs can adversely affect the safety and reliability of the product and may void the warranty. If you are not qualified to perform the repair of this product properly and safely, you should not risk trying to do so and refer the repair to a qualified service technician.
WARNING This product contains lead in solder and certain electrical parts contain chemicals which are known to the state of California to cause cancer, birth defects or other reproductive harm.
Health & Safety Code Section 25249.6 – Proposition 65
NOTICE (FOR CANADIAN MODEL ONLY) Fuse symbols (fast operating fuse) and/or (slow operating fuse) on PCB indicate that replacement parts must be of identical designation.
REMARQUE (POUR MODÈLE CANADIEN SEULEMENT) Les symboles de fusible (fusible de type rapide) et/ou (fusible de type lent) sur CCI indiquent que les pièces de remplacement doivent avoir la même désignation.
(FOR USA MODEL ONLY)
1. SAFETY PRECAUTIONS
The following check should be performed for the continued protection of the customer and service technician.
LEAKAGE CURRENT CHECK
Measure leakage current to a known earth ground (water pipe, conduit, etc.) by connecting a leakage current tester such as Simpson Model 229-2 or equivalent between the earth ground and all exposed metal parts of the appliance (input/output terminals, screwheads, metal overlays, control shaft, etc.). Plug the AC line cord of the appliance directly into a 120V AC 60Hz outlet and turn the AC power switch on. Any current measured must not exceed 0.5mA.
Reading should not be above
0.5mA
Earth ground
Device under test
Also test with plug reversed (Using AC adapter plug as required)
Leakage current tester
Test all exposed metal surfaces
ANY MEASUREMENTS NOT WITHIN THE LIMITS OUTLINED ABOVE ARE INDICATIVE OF A POTENTIAL SHOCK HAZARD AND MUST BE CORRECTED BEFORE RETURNING THE APPLIANCE TO THE CUSTOMER.
2. PRODUCT SAFETY NOTICE
Many electrical and mechanical parts in the appliance have special safety related characteristics. These are often not evident from visual inspection nor the protection afforded by them necessarily can be obtained by using replacement components rated for voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in this Service Manual. Electrical components having such features are identified by marking with a in this Service Manual. The use of a substitute replacement component which does not have the same safety characteristics as the PIONEER recommended replacement one, shown in the parts list in this Service Manual, may create shock, fire, or other hazards. Product Safety is continuously under review and new instructions are issued from time to time. For the latest information, always consult the current PIONEER Service Manual. A subscription to, or additional copies of, PIONEER Service Manual may be obtained at a nominal charge from PIONEER.
on the schematics and on the parts list
AC Leakage Test
2
2. EXPLODED VIEWS AND PARTS LIST
NOTES:• Parts marked by "NSP" are generally unavailable because they are not in our Master Spare Parts List.
2.1 PACKING
The mark found on some component parts indicates the importance of the safety factor of the part.
Therefore, when replacing, be sure to use parts of identical designation.
Screws adjacent to mark on the product are used for disassembly.
GR-209
8
5
6
1
1
2
4
10
3
9
7
(1)PACKING PARTS LIST
Mark No. Description Part No.
1 Pin Plug Cords (L = 1m) PDE1248 2 Polyform L 14904081-000 3 Polyform R 14904082-000 4 Polyethlene Bag Z21-038
(0.03X230X340)
5 Operating Instructions See Contrast table (2) 6 Power Plag Adaptor See Contrast table (2)
NSP 8 Warranty Card • • • • • NSP 9 Packing Sheet • • • • •
7 Carton Box See Contrast table (2)
10 CAUTION 220V LABEL See Contrast table (2)
(2) CONTRAST TEBLE
GR-209/MYXCN1 and SDXCN1 are constructed the same except for the following:
Mark
No.
5 Operating Instructions 15202090-0297 Not used
/Dutch/Swedish/Spanish/Portuguese)
5 Operating Instructions Not used 15202091-0297
6 Power Plag Adaptor Not used VKX1007 7 Carton Box 15302090-0297 15302091-0297
10 CAUTION 220V LABEL Not used ARR7003
Symbol and Description
(English/French/German/Italian
(English/Spanish/Chinese)
MYXCN1 type SDXCN1 type
Part No.
Remarks
3
GR-209
2.2 EXTERIOR SECTION
18
18
18
20
19
19
18
9
18
19
18
20
2
19
23
10 (1/4 : EQ PCB )
2
18
22
18
18
18
10 (3/4 : EQ ON/OFF PCB)
5
1
10 (2/4 : POWER PCB )
SDXCN1 type Only
18
21
18
18
16
13
15
18
18
6
18
18
7
18
4
3
6
6
6
6
6
18
18
18
18
13
18
13
18
3
17
6
6
8
10(4/4 : JACK PCB)
18
13
18
3
3
18
4
(1) EXTERIOR SECTION PARTS LIST
Mark No. Description Part No.
1 Front Cabinet 10104080-002 2 EQ Bracket 12904082-010 3 EQ Knob(Black) 12704082-010 4 Power Button 12804080-010 5 EQ On/Off Button 12804080-110
6 Post 13004082-000 7 Rear Panel See Contrast table (2)
NSP 8 Bottom Cabinet • • • • •
9 Bonnet Cover 18004083-010
10 Main Bord Assy See Contrast table (2) 11 • • • • •
12 • • • • • 13 Foot(Black)W/O H/S 13821007-010 14 • • • • •
15 AC Power Cord 02360020-004
GR-209
NSP 16 Bushing 13000000-001
21 Voltage Selector See Contrast table (2) 22 Fuse (630mA/250V) 05005020-063
17 Name Plate PAM1776 18 Screw BBZ30P080FZK 19 Screw IBZ30P080FMC 20 Screw BPZ26P080FMC
23 Fuse Caution Label 15454081-003
(2) CONTRAST TEBLE
GR-209/MYXCN1 and SDXCN1 are constructed the same except for the following:
Mark
No.
Symbol and Description
MYXCN1 type SDXCN1 type
7 Rear Panel 18004085-102 18004085-201
10 Main Bord Assy GR209/MY GR209/SD
Part No.
Remarks
21 Voltage Selector Not used AKX-507