Introduction __________________________________________________________________________________________ 5 General description __________________________________________________________________________________ 6 Indications for use____________________________________________________________________________________ 7 Important safety information ________________________________________________________________________ 7 Before first use _______________________________________________________________________________________ 11 Cleaning and disinfecting ____________________________________________________________________________ 11 Using the breast pump _______________________________________________________________________________ 14 Using the breast pump when you have symptoms of engorgement _______________________________ 20 After use ______________________________________________________________________________________________ 20 Feeding breast milk with the bottle__________________________________________________________________ 21 Compatibility _________________________________________________________________________________________ 23 Ordering accessories _________________________________________________________________________________ 23 Disposal_______________________________________________________________________________________________ 24 Full Two-Year Warranty ______________________________________________________________________________ 24 Troubleshooting ______________________________________________________________________________________ 24 Undesirable side effects _____________________________________________________________________________ 26 Storage conditions ___________________________________________________________________________________ 27 Electromagnetic fields (EMF) ________________________________________________________________________ 27 Technical information ________________________________________________________________________________ 27 Explanation of symbols ______________________________________________________________________________ 30
5
English
Introduction
Congratulations on your purchase and welcome to Philips Avent! To fully benefit from the support that Philips Avent offers, register your breast pump at www.philips.com/welcome.
The Philips Avent single/double electric breast pump Advanced is inspired by babies and their natural suction movement. The soft silicone cushion stimulates the nipple with gentle massaging movements, helping you to express milk comfortably and effectively. The combination of suction and nipple stimulation triggers fast milk flow. The no-lean-forward design enables you to sit in a relaxed, upright position while expressing.
Healthcare professionals and the World Health Organization recommend to exclusively feed children with breast milk during the first six months of life and to continue giving them breast milk for two years next to offering additional nutritious foods. This is because your breast milk is specially adapted to your baby’s needs and helps to protect your baby against infection and allergies. To breastfeed longer, you can express and store your milk so that your baby can still enjoy the benefits of it, even if you cannot be there to provide it yourself. As the pump is compact, quiet and discrete to use, you can take it with you anywhere, allowing you to express milk at your own convenience and to maintain your milk supply.
If breastfeeding goes well, it is advisable (unless recommended otherwise by your healthcare professional) to wait until your milk supply and breastfeeding schedule are established (normally at least 2 to 4 weeks after giving birth) before you start expressing.
6
English
General description
Note: The numbers mentioned below refer to the numbers on the figure of the front foldout page
of this user manual.
Note: The double breast pump comes with two pieces of the items shown in Figures B and C.
Product description (Fig. A)
A1 Motor unit A2 Breast pump kit A3 Bottle A4 Adapter*
Breast pump kit (Fig. B)
B1 Silicone tube and cap B2 Silicone diaphragm B3 Pump body
Philips Avent Natural bottle (Fig. C)
C1 Bottle cap C2 Screw ring C3 Feeding nipple
A5 Double breast pump * The adapter supplied may vary for different
countries.
B4 Cover B5 Cushion B6 White valve
C4 Sealing disc C5 Bottle
Motor unit part description (Fig. D)
D1 USB power inlet D2 On/off button with pause/play function D3 Mode selection button D4 'Level down' button
D5 'Level up' button D6 LED display D7 Tubing port for single breast pump D8 Tubing ports for double breast pump
Accessories
There are multiple versions of this breast pump package, which all come with a different combination of the following Philips Avent accessories:
-
Breast pads
-
Travel bag
-
Insulation pouch
-
Cleaning brush
* For these accessories, a separate user manual is provided.
-
Storage cups with adapter*
-
Breast milk storage bags*
-
Natural bottles
-
Breast pump belt*
English
Indications for use
The Philips Avent single/double electric breast pump Advanced is intended to express and collect milk from the breast of a lactating woman, and to alleviate engorgement of the breast. Thedevice is intended for a single user.
Important safety information
Read this user manual carefully before you use the breast pump and save it for future reference. This user manual can also be found online on the Philips Avent website: www.philips.com/avent. This product is operated by the lactating woman herself. You can use this breast pump in an everyday environment.
Contraindications
- Never use the breast pump while you are pregnant, as pumping can induce labor.
Warnings
7
English
Warnings to avoid choking, strangulation and injury:
- Do not allow children or pets to play with the motor unit, the adapter, packaging materials or accessories.
- Always unplug the breast pump after use and when fully charged. Store the breast pump when not in use.
-
This breast pump is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge. Such persons can only use this breast pump if they are supervised by or have received proper instruction concerning use of the appliance by a person responsible for their safety.
Warning to prevent transmitting infectious diseases:
-
If you are a mother who is infected with Hepatitis B, Hepatitis C or Human Immunodeficiency Virus (HIV), expressing breast milk will not reduce or remove the risk of transmitting the virus to your baby through your breast milk.
8
English
Warnings to avoid electric shock:
-
Inspect the breast pump, including the adapter, for signs of damage before each use. Do not use the breast pump if the adapter or plug is damaged, if it does not work properly or if it has been dropped or submerged in water.
-
Only use the adapter (S009AHz050yyyy) provided with this breast pump.
-
Always ensure that it is easy to disconnect the device from the mains in case of malfunction. The adapter is considered the disconnection device.
Warnings to avoid contamination and to ensure hygiene:
-
For hygienic reasons, the breast pump is only intended for repeated use by a single user.
-
Clean and disinfect all parts before first use and after each use.
-
Do not use antibacterial or abrasive cleaning agents to clean the breast pump parts as this may cause damage.
-
Wash your hands thoroughly with soap and water before you touch breast pump parts and breasts to prevent contamination. Avoid touching the inside of containers or lids.
Warnings to avoid breast and nipple problems including pain:
-
Do not use the breast pump if the silicone diaphragm appears to be damaged or broken. See chapter ‘Ordering accessories’ for information on how to obtain replacement parts.
-
Only use accessories and parts recommended by Philips Avent.
-
There are no user serviceable parts inside the motor unit of the breast pump.
-
No modification of the breast pump is allowed. If you do so, your warranty becomes invalid.
-
Never use the breast pump while you are sleepy or drowsy to avoid lack of attention during use.
-
Always switch off the breast pump before you remove the pump body from your breast, in order to release the vacuum.
English
-
If the vacuum is uncomfortable or causes pain, switch off and remove the breast pump from your breast.
-
Do not continue pumping for more than five minutes at a time if you do not succeed in expressing any milk. Try to express at another time during the day.
-
If the process becomes very uncomfortable or painful, stop using the pump and consult your healthcare professional.
Warnings to prevent damage and malfunction of the breast pump:
-
Portable radio frequency (RF) communications equipment (including mobile phones and peripherals such as antenna cables and external antennas) should not be used closer than 30cm (12in) to any part of the breast pump, including adapter. This could have a negative effect on the performance of the breast pump.
-
Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation.
9
English
Warning to avoid increased electromagnetic emissions or decreased electromagnetic immunity of this device, resulting in improper operation:
-
Do not use any other adapter or charging cable than supplied with the device.
Battery safety instructions
-
Only use thisproduct for its intended purpose and follow the general and battery safety instructions as described in this user manual. Any misuse can cause electric shock, burns, fire and other hazards or injuries.
-
To charge the battery, only use the detachable adapter (S009AHz050yyyy) provided with the product. Do not use an extension cord.
-
Charge, use and store the product at the temperature ranges indicated in the technical specifications table in this user manual.
-
Always unplug the product when it is fully charged.
10
English
-
Do not burn products and their batteries and do not expose them to direct sunlight or to high temperatures (e.g. in hot cars or near hot stoves). Batteries may explode if overheated.
-
If the product becomes abnormally hot, gives off an abnormal smell, changes color or if charging takes much longer than usual, stop using and charging the product and contact your local Philips dealer.
-
Do not place products and their batteries in microwave ovens or on induction cookers.
-
This product contains a rechargeable battery that is non­replaceable. Do not open the product to replace the rechargeable battery.
Cautions
Cautions to prevent damage to and malfunctioning of the breast pump:
-
Prevent the adapter and motor unit from coming into contact with water.
-
Never put the motor unit or the adapter in water or in a dishwasher, as this causes permanent damage to these parts.
-
Keep the adapter and the silicone tubes away from heated surfaces to avoid overheating and deformation of these parts.
SAVE THESE INSTRUCTIONS.
English
Before first use
Disassemble, clean and disinfect all parts that come into contact with breast milk before you use the breast pump for the first time and after every use.
Fully charge the device before you use it for the first time or after a long period of non-use.
Cleaning and disinfecting
Overview
Clean and disinfect the parts that come into contact with the breast and breast milk as described below:
When How
11
English
Clean and disinfect before first use and after every use.
The following parts do not come into contact with the breast and breast milk; clean them as described below:
When How
Clean when needed. Wipe with a clean, damp cloth with
Disassemble all parts and then clean them as described in chapter 'Cleaning' and disinfect them as described in chapter 'Disinfecting'.
water and mild detergent.
12
English
Step 1: Disassembling
Disassemble the breast pump, bottle and storage cup completely. Also remove the white valve from the breast pump.
Step 2: Cleaning
The parts that come in contact with milk can be cleaned manually or in the dishwasher.
Warning: Do not use antibacterial or abrasive cleaning agents to clean the breast
pump parts as this may cause damage.
Caution: Never put the motor unit or the adapter in water or in a dishwasher, as this
causes permanent damage to these parts.
Caution: Be careful when you remove and clean the white valve. If it gets damaged, your breast pump does not function properly. To remove the white valve, gently pull at the ribbed tab on the side of the valve. To clean the white valve, rub it gently between your fingers in warm water with some dishwashing liquid. Do not insert objects into the white valve, as this may cause damage.
Step 2A: Manual cleaning
5 min.
Supplies needed:
-
Mild dishwashing liquid
-
Drinking-quality water
-
Soft, clean brush
-
Clean tea towel or drying rack
-
Clean sink or bowl
English
13
English
1. Rinse all parts under a running tap with lukewarm water.
5. Leave all parts to air­dry on a clean tea towel or drying rack.
2. Soak all parts for 5minutes in warm water with some mild dishwashing liquid.
Step 2B: Cleaning in the dishwasher
Supplies needed:
-
Mild dishwashing liquid or a dishwashing tablet
-
Drinking-quality water
Note: Food colorings may discolor parts.
3. Clean all parts with a cleaning brush.
4. Thoroughly rinse all parts under a running tap with cold clear water.
1. Place all parts on the top rack of the dishwasher.
2. Put dishwashing liquid or a tablet in the machine and run a standard program.
3. Leave all parts to air­dry on a clean tea towel or drying rack.
5 min.
14
English
Step 3: Disinfecting
Supplies needed:
-
A household pot
-
Drinking-quality water
Caution: During disinfection with boiling water, prevent the bottle or other parts from touching the side of the pot. This can cause irreversible product deformation or damage that Philips cannot be held liable for.
1. Fill a household pot with enough water to cover all parts and place all parts in the pot. Let the water boil for 5minutes. Make sure the parts do not touch the side of the pot.
2. Allow the water to cool down.
3. Gently remove the parts from the water. Place the parts on a clean surface/tea towel or drying rack to air-dry.
4. Store the dry items in a clean, dry and covered container.
Using the breast pump
Cushion size
The Philips Avent single/double electric breast pump Advanced has a soft, active cushion. There is only one cushion size. It gently stimulates your nipple to trigger milk flow. The cushion is made of flexible silicone, fitting nipple sizes up to 30mm/1.18in.
Charging the breast pump
Fully charge the battery before you use the breast pump for the first time and when the battery is low. Fully charging the battery takes up to 4hours.
English
15
English
1. Switch off the device. 2. Insert the adapter into the power outlet and insert the small plug at the other end into the motor unit.
3. The battery is charging.
4. When the battery is fully charged, remove the adapter from the power outlet and pull the small plug out of the motor unit.
Battery indicator light description
All lights are steady on. The battery is fully charged.
Charged battery operates approximately 3pumping sessions.*
* One session is the equivalent of 15minutes (double electric breast pump) or 30 minutes (single electric breast pump).
Two lights are steady on.
The battery is charged sufficiently for maximum two sessions.*
First light flashes slowly.
The battery is charged sufficiently for maximum one session.*
First light flashes quickly.
The battery is very low, the device will soon stop operating, charging is needed.
Battery lights light up one by one and go out all together.
The battery is charging.
Assembling the breast pump
Make sure you have cleaned and disinfected the parts of the breast pump that come into contact with milk.
Warning: Be careful, when you have disinfected the breast pump parts by boiling them, they can be very hot. To prevent burns, only start assembling the breast pump when disinfected parts have cooled down.
Warning: Wash your hands thoroughly with soap and water before you touch breast pump parts and breasts to prevent contamination. Avoid touching the inside of containers or lids.
Check the breast pump kit parts for wear or damage before use and replace them if necessary.
3 sec.
16
English
Note: Correct placement of the cushion, silicone diaphragm and silicone tube is essential for the
breast pump to form a proper vacuum.
1. Wash your hands thoroughly with soap and water.
4A. Push the inner part of the cushion into the funnel against the line (indicated with an arrow).
7. Connect the tube(s) to the motor unit.
2. Push the white valve in the pump body as far as possible.
5. Place the silicone diaphragm in the pump body.
8A. When the breast pump is charged, you can use it cordless. Press and hold the on/off button until the device switches on.
3. Screw the pump body onto the bottle.
5A. Make sure that the silicone diaphragm fits securely around the rim by pressing it down with your thumbs.
8B. You can also use the breast pump connected to the power outlet. If the battery is low, insert the adapter into the power outlet and insert the small plug at the other end into the motor unit.
4. Place the cushion in the pump body and make sure that the rim covers the pump body.
6. Attach the silicone tube and cap onto the silicone diaphragm. Push down the cap until it is securely in place.
9. The breast pump is now ready for use.
Note: You can place
7
1 3 5
4 6
8
2
1
2
3
4
the cover over the cushion to keep the breast pump clean when you take it with you and while you are preparing for expressing.
Motor unit part description
1 USB power inlet 2 On/off button with
pause/play function 3 Mode selection button 4 'Level down' button 5 'Level up' button 6 LED display 7 Tubing port for single
breast pump 8 Tubing ports for double
breast pump
English
17
English
LED display description
1 Battery indicator lights 2 Timer (minutes) and
vacuum level indication 3 Expression icon 4 Stimulation icon
18
English
Explanation of modes
The breast pump has two modes. Below you find an explanation of these modes.
Mode icons Mode Explanation No. of suction levels
Stimulation mode Mode to stimulate the breast to
start up the milk flow.
8 suction levels
Expression mode Mode for efficient milk removal
after milk has started flowing. After 90 sec. of stimulation, the device automatically switches to the expression mode.
The number on the display shows the running time in minutes.
When you change the suction level, the display shows the selected suction level for a few seconds and then shows the running time again.
16 suction levels
Pumping instructions
Warning: Before you remove the pump body from your breast, always switch off the
breast pump to release the vacuum.
Warning: Do not continue pumping for more than 5 minutes at a time if you do not
succeed in expressing any milk. Try to express at another time during the day.
Warning: If the process becomes very uncomfortable or painful, stop using the pump
and consult your healthcare professional.
Note: If you regularly express more than 125ml/4floz per session, you can purchase and use a
260ml/9floz Philips Avent Natural bottle to prevent overfilling and spillage.
Note: The breast pump can be used cordless if it is sufficiently charged, but you can also use it
connected to the power outlet.
3 sec.
3 sec.
English
19
English
1. Wash your hands thoroughly with soap and water and make sure that your breast is clean.
5. The display shows the running time.
2. Place the breast pump kit onto your breast. Make sure that you center your nipple.
6. Use the 'level up' and 'level down' buttons to change the suction level to your preference.
3. Press and hold the on/off button until the device switches on. The indicator lights go on to indicate that the device is in stimulation mode.
7. After 90 seconds the breast pump will switch smoothly to expression mode and slowly increase its vacuum to the last used expression suction level (or level 11 when used for the first time).
4. The breast pump starts in stimulation mode and slowly increases its vacuum to the last used stimulation suction level (or level 5 when used for the first time).
8. If your milk starts flowing earlier or if you want to switch from expression to stimulation mode, you can switch modes with the mode selection button.
9. Briefly press the on/off button if you want to pause. To continue, briefly press the on/off button again.
Tip: For optimal expression, choose the highest setting that still feels comfortable. This setting may
differ across different
10. Press and hold the on/off button to switch off.
sessions.
11. Unplug the adapter from the power outlet and pull the small plug out of the motor unit.