Philips Domestic Appliances and Personal Care
PRODUCT INFORMATION
Fan Heater
HD 3271
HD 3272
HD 3273
Functions, features and operational aspects :
HD 3271 HD 3272 HD 3273
Switch : 4 positions : off x x x
cold air x x x
●
●●
Thermostat with frost protection - x x
Pilot light - x x
Resettable cut-out x x x
Wall bracket / Stand - - x
Voltage / frequency 50 -60 Hz : 220 - 230 V
Power consumption : 2000 Watts
Safety : insulation class
Product meets the requirements regarding interference
suppression on radio and TV.
1000 Watts x x x
2000 Watts x x x
Published by P hilips Domestic Appliances and Personal Care Printed in the Netherlands
4822 729 21695
96/08
PCS 87 777
©
Copyright reserved Subject to modification
DISASSEMBLY ADVICE PARTS LIST HD 3271 / HD 3272 / HD 3273
CAPS OPERATION
KNOBS 1
SWITCH KNOB2
THERMOSTAT KNOB3
SWITCH 4
THERMOSTAT 5
PILOT LIGHT 9
remove SCREW A (4x)
remove FRONT PART 101
remove CAPS OPERATION
KNOBS 2
MOTOR 7
HEATING ELEMENT 6
remove SCREW A 4x
remove FRONT PLATE 101
remove SCREW B 2x
FAN BLADE 8
remove SCREW A 4x
remove FRONT PLATE 101
STAND 102
POS. DESCRIPTION SERVICE CODE
1 CAP OPERATION KNOBS 4822 462 10812
2 SWITCH KNOB 4822 410 10791
3 THERMOSTAT KNOB 4822 410 10792
4 SWITCH 4822 273 10319
5 THERMOSTAT 4822 282 10299
6 HEATING ELEMENT 4822 259 10212
7 MOTOR 4822 361 10521
8 FAN BLADE 4822 515 20148
9 PILOT LAMP 4822 134 10056
NOTE:
For standardisation reasons, only the red-coloured operation
knobs have been incorporated into this manual.
The grey coloured knobs have to be replaced by the
red-coloured ones.
When a cordset has to be replaced, always use a cordset with
core wires with a diameter of 1.0 mm
Parts, with numbers from 100 upwards, cannot be ordered
separatly.
L
S
2
.
4
3
2
1
1000 W
1000 W
P. L.
M
NOTE: AFTER THE PRODUCT HAS BEEN REPAIRED, IT
SHOULD FUNCTION PROPERLY AND HAS TO
MEET THE SAFETY REQUIREMENTS AND
LEGAL REGULATIONS AS LAID DOWN AND
OFFICIALLY ESTABLISHED AT THIS MOMENT.
Possible complaints
The heater doesn’t function :
1) When set to the cool air setting
action: Set the thermostat knob to the highest position.
2) The overheating safety device has been activated
action: To reset the overheating device, remove the
mains plug from the wall socket and let the
heater cool down for 30 minutes.
N
T
L
= LINE
N
= NEUTRE
T = THERMOSTAT (Not included in HD3271)
C. O.
= CUT OUT
C. O.
P. L.
= PILOT LIGHT (Not included in HD3271)
S
= SWITCH
M
= MOTOR
DAP0244